Compressor Control of a Multi-type AIr Conditioning System (멀티형 냉방시스템의 압축기 제어)

  • 한도영;권형진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.780-786
    • /
    • 2001
  • For the compressor speed control of a multi-type air conditioning system, a fuzzy control algorithm was developed. The sum of zone temperature errors and its derivative were used as input variables, and the compressor speed was selected as the output variable. To test the effectiveness of the control algorithm, one outdoor environmental chamber and four indoor environmental chambers were used. In the chambers the zone temperature step change test and the indoor unit change over test were performed. Test results showed that, for the control of compressor speed, the fuzzy control algorithm was more effective than the conventional proportional control algorithm for the energy conservation.

  • PDF

Control of Compressors and Electronic Expansion Valve considering the Safe Operation of a Tandem-type Air-conditioning system (텐덤형 냉방시스템의 안전운전을 고려한 압축기와 전자팽창밸브 제어)

  • Han, Do-Young;Kim, Jae-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.675-680
    • /
    • 2006
  • Capacities of a tandem-type air-conditioner may be modulated by turning on and off of multiple compressors, and adjusting the position of a electronic expansion valve. In this study, control algorithms for compressors and a electronic expansion valve were developed by using fuzzy logics. The pressure control algorithm was also developed for the safe operation of compressors. There algorithms were implemented in a test lab and proved to be effective for the control of indoor air temperature and superheat temperature,

  • PDF

Effect of Greenhouse Cooling Method on the Growth and Yield of the Tomato cv. Momotaro in Warm Season (고온기 유리온실의 냉방방법이 토마토 생육 및 수량에 미치는 영향)

  • 최영하;이재한;박동금;권준국;엄영철
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1999.11a
    • /
    • pp.164-168
    • /
    • 1999
  • 온실은 동절기 난방을 주목적으로 설비되어 년중 작물재배 시는 하절기 온실내부 온도가 필요이상으로 상승하여 실내온도가 35-4$0^{\circ}C$ 정도로 올라가는데 이러한 상태에서의 온도는 많은 작물의 생육적온을 벗어난 온도로서 고온장해를 나타낸다. 이 같은 문제점을 해결하기 위해 몇 가지 냉방방법이 알려져 있는데 에어컨 등과 같은 냉방장치를 이용한 기계적 냉각방식과 수분증발을 통한 증발식 냉각방식으로 대별되며 이중 기계적인 냉방방식은 설비나 유지관리 면에서 비용이 많이 들어 비경제적이고, 증발냉각 방식중에서도 Fan and Pad 법이 가장 효과가 좋은 것으로 알려져 있으나 이역시 설치 및 유지비가 많이 들고, vep의 탈부착이 어려워 고정시켜놓을 경우 동계 광투과에 방해가 되는 등의 문제가 많다. (중략)

  • PDF

Control of Compressor and Electronic Expansion Valve for a Tandom-type Air-conditioner (텐덤형 냉방시스템의 압축기와 전자팽창밸브 제어)

  • Jung, Nam-Chul;Han, Do-Young
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.469-473
    • /
    • 2005
  • Capacities of a tandom-type air-conditioner may be modulated by turning on/off multiple compressors and adjusting positions of a electronic expansion valve. In this study. control algorithms for compressors and a electronic expansion valve were developed by using fuzzy’ logics. There algorithms were implemented in a test lab and proved to be effective for the control of indoor air temperature and superheat temperature.

  • PDF

Performance Test for a Horizontal Regenerative Evaporative Cooler (수평형 재생증발식 냉방기의 성능시험)

  • Song, Gwi-Eun;Lee, Dae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.621-626
    • /
    • 2006
  • Regenerative evaporative cooling is known as an environment-friendly and energy efficient cooling method. A regenerative evaporative cooler (REC) consisting of dry and wet channels is able to cool down the air stream below the inlet wet-bulb temperature. In the regenerative evaporative cooler, the cooling effect is achieved by redirecting a portion of the air flown out of the dry channel into the wet channel and spraying water onto the redirected air. In this study, a horizontal regenerative cooler is considered. In the horizontal regenerative cooler, the flow direction of evaporating water has a right angle to the flow direction of supply air. This difference was investigated with visualization technique and simplified 2-module performance test was done in a thermo-environment chamber. Optimum design configuration is changed due to the wet channel which are easily fully covered with evaporating water and block the air flow inside the channel. Applying the optimized fin configuration design with the highly wetting surface treatment, a regenerative evaporative cooler was fabricated and tested to Identify the cooling performance improvement and operation characteristics. From the experimental results at the intake condition of $32^{\circ}C$ and 50% RH, the supply temperature was measured to be around $23.4^{\circ}C$. The cooling effectiveness based on the inlet dewpoint temperature was evaluated 73% which is almost close to the design expectation.

  • PDF

Cooling Efficiency and Growth of Tomato as effected by Root-zone Cooling Methods in Summer Season (고온기 근권 냉방방식에 따른 냉방효율과 토마토 생육에 미치는 영향)

  • 이재한;권오근;최영하;박동금;권준국
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1999.11a
    • /
    • pp.130-133
    • /
    • 1999
  • 우리나라의 시설재배는 비가림 형태에서 많은 자본과 기술이 투자된 현대화 고정시설로 발전해가고 있으며 면적도 증가하고 있다. 시설의 활용면에서는 주로 동절기에 집중되어 있고, 하절기에는 최고기온이 3$0^{\circ}C$ 이상되는 날이 2-3개월 정도로 시설내 작물재배는 거의 불가능한 실정이다. 따라서 하절기에는 대부분 휴작함으로서 시설의 주년이용에 문제점으로 대두되고 있다. (중략)

  • PDF

Cooling Efficiency and Growth of Tomato as Affected by Root Zone Cooling Methods in Summer Season (고온기 근권냉방방식에 따른 냉방효과와 토마토 생육)

  • 이재한;권준국;권오근;최영하;박동금
    • Journal of Bio-Environment Control
    • /
    • v.11 no.2
    • /
    • pp.81-87
    • /
    • 2002
  • This study was conducted to investigate the cooling efficiency and growth of tomatoes by root zone cooling device using a pad-box and cultivated system. The structure of the root zone cooling system using a pad-box was four piece of pads bonded an the side and a fan set at the bottom. Cool wind was generated by the outside air which was punched at intervals of 10 cm along three rows. Cold wind flowed to the root zone in the culture medium. The root zone cooling efficiency of cold wind generation by using a pad-box flowing through a wet-pad was determined. Major characteristic of this cuttural system consist of bed filled with a perlite medium and a ventilation pipe using PVC. The cold wind generation by a pad box (CWP) was compared to that of cold wind generation by a radiator (CWR), cold water circulation using a XL-pipe (CWX) and the control (non-cooling). When the temperature of water supplied was 16.2-18.4$^{\circ}C$, temperatures in the medium were 20.5~23.2$^{\circ}C$ for CWP 22.7~24.2$^{\circ}C$ for CWR, 22.8~24.27$^{\circ}C$ for CWX and 23.1~-29.6$^{\circ}C$ for the control. The results show that the cold wind temperature using the pad-box was lower by 1~2$^{\circ}C$ than that of cold water circulation in the XL-pipe and lower by 5~6$^{\circ}C$ than that of the control. Growth such as leaf length, leaf width, fresh weight and dry weight, was greater in three root zone cooling methods than in the control. Root activity was higher in the rat zone cooling methods than in the control. However, there was no significant difference among root zone cooling methods.

Dynamic simulation of a solar absorption cooling system (태양열을 이용한 흡수식 냉방기의 동특성 시뮬레이션)

  • 정시영;조광운
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.784-794
    • /
    • 1998
  • The present study has been directed at developing thermal models to investigate the dynamic behavior of a solar cooling system including an absorption chiller, solar collectors, a hot water storage tank, a fan coil unit, and the air-conditioned space. The operation of the system was simulated for 8 hours in two different operation modes. In the mode 1, the system operated without any capacity control.0 the mode 2, an auxiliary boiler supplied heat to the generator if hot water temperature became lower than a certain value. Moreover, the mass flow rate of hot water to the generator was controlled by comparing the instantaneous room air temperature with the design value. The variation of temperature and concentration in the system components and that of heat transfer rates in the system were obtained for both modes of operation. It was found that the room temperature was maintained near the desired value in the mode 2 by supplying auxiliary heat or controlling the mass flow rate of hot water, while the deviation of room temperature was quite great in the mode 2.

  • PDF

Analysis on Cooling Effects of the Vertical Type Geothermal Heat Pump System Installed in a Greenhouse for Raising Seedling (수직형 지열히트펌프 시스템의 육묘 온실 냉방 효과 분석)

  • Kang, Youn Ku;Ryou, Young Sun;Kim, Jong Goo;Kim, Young Hwa;Jang, Jae Kyoung
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.19-25
    • /
    • 2013
  • In this study, the cooling experiment was carried out in $1,650m^2$ area of the seedling greenhouse from June 6, 2011 to september 18, 2011 with the vertical type geothermal heat pump system of 350 kW scale (175 kW ${\times}$ 2 units) installed in the greenhouse, cooling effects were analyzed and we tried to find more effective operation methods of the geothermal heat pump system. In case of one unit heat pump (175 kW) operation, when evaporator inlet water temperature changed from $13.0^{\circ}C$ to $15.5^{\circ}C$, cooling COP of the system was in 1.1~1.8 range and in case of two unit heat pump (350 kW) operation, when evaporator inlet water temperature changed from 13.0 to 15.5, cooling COP of the system was in 2.0~2.7 range. The accumulated cooling heat quantity of June, July, August and September was 14,718.6, 26,765.1, 28,437.2 and 10,065.0 kWh, respectively.