냉매 가열식 대용량 VRF 히트펌프 사이클 설계를 통한 극한랭지 난방 성능 평가 (Heating Performance Evaluation of the VRF Heat Pump System with Refrigerant Heating Cycle for the Extreme Cold Region)

  • 이상헌;최송;김병순;이재근;이광호
    • 설비공학논문집
    • /
    • 제23권8호
    • /
    • pp.571-579
    • /
    • 2011
  • Heat pump systems for commercial building with variable refrigerant flow(VRF) are expanding a market due to high energy efficiency, lower maintenance cost and easy installation comparing with the conventional heat pump with the constant refrigerant flow. In general, heat pump systems degrade the energy efficiency in the extremely low temperature regions. In this study, VRF heat pump system with refrigerant heating is experimentally investigated to overcome the low heating performance in the extremely low temperature regions. VRF heat pump system with refrigerant heating is found out the sufficient heating performance in the -25 degree temperature condition comparing with the conventional heat pump system and is obtained more than 2,500 kPa high pressure in the evaporator at low temperature.

냉매가열식 열펌프시스템의 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance of a Heat Pump with a Refrigerant Heating Device)

  • 김상혁;박윤철
    • 설비공학논문집
    • /
    • 제18권9호
    • /
    • pp.707-713
    • /
    • 2006
  • To improve heating performance of the heat pump in winter season, refrigerant heating device was applied to conventional heat pump. The refrigerant heating device operates at the heating capacity does not enough to the heating load requirement of the conditioning space. When the discharge air temperature of the indoor heat exchanger goes down to below $40^{\circ}C$ which is criterion for comfort of the occupants in the conditioning space, the system also starts. The refrigerant heating system has new concept of auxiliary heating device for heat pump in winter. In this study, the system performance was analyzed through experiments and parametric study was conducted to improve the COP and control strategies.

식품가공에서 Impingement 기술의 응용

  • 이부용
    • 식품기술
    • /
    • 제11권2호
    • /
    • pp.70-78
    • /
    • 1998
  • 공기와 같은 유체를 식품의 표면에 직접 고압으로 분사하는 것은 그 식품을 가열하거나, 건조, 냉각, 냉동시키는데 큰 도움을 주고 있다. Impingement-분사(공기, 스팀), 조사(방사선, 레이저), 침투(당액, 냉매) 등의 식품가공기술 기술은 우리가 생활하고 있는 주변에서 일상적으로 나타는 현상이다. 지표면에 태양빛이 전달되는 것이나 상점에서 물건구입시 포장지에 붙은 바코드(barcode)에 레이저빔을 쏘는 것도 모두 Impingement현상이다. 레이더도 전자파를 발사하는것(Impinging)이며, 배나 잠수함도 음파를 발사하여 장애물을 탐지하면서 운항한다. 세차장에서 차를 세차하는 것도 고압의 물을 분사(Impinging)하는 기술이 동원 되는 것이다. Impingement 방식에 의해 식품을 가열하거나 냉각하는 것은 기존의 방법들보다 속도는 느리지만 그만한 값어치가 있는 유용한 식품가공 기법이다.

  • PDF

압력용기에 가용접한 러그(Lug)파단으로 인한 충돌

  • 한국환경기술인연합회
    • 환경기술인
    • /
    • 제23권통권235호
    • /
    • pp.46-47
    • /
    • 2006
  • 냉매저장용 압력용기를 제작하던중 H-Beam을 압력용기 외부에 사각모양으로 용접후 모서리 부분에 클립(Clip)을 중심에 맞춰 용접작업을 하던중 아래 2곳의 중심을 맞추기 위해 H-Beam이 용이하게 휘어질수 있도록 산소용접기로 가열후 H-Beam에 러그(Lug)를 가용접한 다음 체인블럭으로 당기는 순간 가용접한 러그(Lug)가 파단되면서 재해자쪽으로 비래하여 충돌 사망한 재해임.

  • PDF

구동장치 및 열교환기 변경에 따른 냉매가열식 열펌프의 성능특성 (Performance of a Refrigerant Heating Type Heat Pump by Changing of Driving Devices and Heat Exchangers)

  • 박윤철;김상혁;김지영
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.49-56
    • /
    • 2008
  • When the outdoor air temperature decreased less than the freezing temperature, frost forms at the surface of heat exchangers and it makes the performance degradation of a heat pump system. In this study, a heat pump system has been developed which has a refrigerant heating device as an auxiliarly heating equipment. To reduce power consumptions of the system, a liquid pump, rather than a compressor, was used to drive refrigerant in the heat pump cycle. Ratio of refrigerant mass flow between a refrigerant heating heat exchanger(GHX) and a outdoor plate heat exchanger(PHX) was varied and the system performance was measured and analyzed. As results, when the refrigerant flow rate to the GHX was decreased, the system performance is decreased due to heat absorption capability restriction of the GHX and small variation of the power consumption in the compressor. The effect on the evaporating and condensing pressure by the distribution ratio of the refrigerant to the each heat exchanger is small compare to the effect by the frequency change in the compressor. When the compressor was replaced by the liquid pump, the capacity of the system decreased a little, however the power consumption decrease approximately 80% compare with the power used in the compressor.

가열기가 내장된 냉매오일 분리기의 성능 고찰 (Performance Analysis of the Refrigerant oil separator with a build-in heater)

  • 김종열
    • 동력기계공학회지
    • /
    • 제15권6호
    • /
    • pp.41-46
    • /
    • 2011
  • Refrigerant oil reduces friction between piston and cylinder of compressor and is normally hard to mix or dissolve in refrigerant. Oil separator deprives refrigerating oil from mixed solution of refrigerant and refrigerant oil. Sometimes much machine oil is carried into an evaporator and is applied to surface of the evaporator, and then disturbs heat transfer through it. Well-made oil separator helps refrigerating system stable and evaporator sustain full capacity. In this paper, new oil separate with different way to structure is suggested and tested. As result the new separates is 13% higher at 0C with 10% mixture and 6% higher at 0C with 20% mixture.

열 펌프의 식품 농축에의 이용 연구 (The Heat Pump Application to the Food Concentration)

  • 박노현;김병삼;강통삼;신동화
    • 한국식품과학회지
    • /
    • 제19권6호
    • /
    • pp.486-491
    • /
    • 1987
  • 고효율의 열발생장치인 열펌프중, 국내에서 이용중인 압축식 열펌프에 대해 성능시험 및 식품농축분야에 이용코자 실증시험을 하였다. 국내에서 $43^{\circ}C$의 온천수를 $51^{\circ}C$까지 가열하기 위해 설치, 운전중인 냉매압축식열펌프(프레온12, 150HP)의 성적계수는 가열측이 4.03, 냉각측이 3.5로 나타났으며, 압축기 효율(${\alpha}$)은 0.477이었다. 또, 압축식열펌프를 국산화하기 위해 개발된 10HP의 열펌프(프레온22)에서 시수를 $39^{\circ}C$까지 가열하는 경우의 성적계수는 가열측이 3.0, 냉각측이 1.87이었다. 원심식농축기(${\alpha}$-LAVAL, CT1B)에 열펌프를 부착한후 설탕물의 농축실험을 한 결과, 수증기 응축에 소비된 열량이 농축에 필요한 증발잠열보다 15%정도 많이 소비되었고, 총괄열전달계수는 $1196\;Kcal/m^{2}{\cdot}h{\cdot}^{\circ}C$이었다. 또, 열펌프에서 제조되는 $60^{\circ}C$$15^{\circ}C$의 물을 열원으로 하여 마늘추출액을 저온농축(증발온도 : $30{\sim}35^{\circ}C$, 진공도 : $28{\sim}40$Torr)한 결과 농축에 소비된 열량과 수증기 응축열량과의 비는 0.961로 나타나 열펌프의 냉매 응축열과 증발열이 열수지 조절이 용이한 조건이었다. 따라서, 열펌프의 식품농축 분야에의 적용성은 매우 좋은 것으로 나타났다.

  • PDF

해수 온도차를 이용한 선박의 ORC 발전 시스템 최적화 (A Optimization of the ORC for Ship's Power Generation System)

  • 오철;송영욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.595-602
    • /
    • 2012
  • 본 논문에서는 선박에서 배출되는 $CO_2$ 배출을 최소화하기 위한 노력의 일환으로 선박으로부터 배출되는 열에너지를 회수하고 재활용하는 방안으로 유기랭킨사이클 발전장치를 구동함으로써 선박의 에너지 효율을 높이고 온실가스 배출을 최소화할 수 있는 방안을 연구하였다. 선박에서 배출되는 배기가스와 냉각 시스템에서 배출되는 열에너지를 회수하여 터빈 발전기를 구동하는 ORC 발전시스템을 설계하고 시뮬레이션 하였다. 다양한 친환경 유기냉매를 이용하여 냉매를 적용하여 온도와 유량변화에 따른 열 해석을 실시하였고 냉각수 열원 예열기, 배기가스 가열기로 시스템을 구성하여 2,400kW급의 발전 출력을 얻을 수 있었다.

HFC134a를 사용한 열펌프 건조기의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Heat Pump Assisted Batch Dryer Using HFC134a)

  • 김영중;임장순
    • 태양에너지
    • /
    • 제17권2호
    • /
    • pp.3-11
    • /
    • 1997
  • 열펌프건조기는 증발기에 의한 냉각및 감습기능과 응축기에 의한 가열기능을 대류형건조기와 연계시킴으로써 필연적 손실로 분류되던 배기가 갖고 있는 현열과 잠열을 회수하여 재활용할 수 있는 이점이 있다. 본 연구에서는 HFC134a를 냉매로 사용한 배치형(batch type) 열펌프건조기를 설계제작하여 건조실의 유지온도, 공기의 바이패스비(bypass ratio), 냉매의 과열도를 일정하게 유지하고 정면풍속(face velocity)과 압축기속도를 변화시켜 건조기의 성능을 분석하였으며 정면풍속의 증가에 따라 열펌프의 성적계수는 증가하나 SMER(Specific Moisture Extraction Rate)은 감소하였다.