발전소 복수기 배열회수 해양온도차 발전설비 적용타당성 검토 (Feasibility Study on Modified OTEC (Ocean Thermal Energy Conversion) by Plant Condenser Heat Recovery)

  • 정훈;김경열;허균영
    • 신재생에너지
    • /
    • 제6권3호
    • /
    • pp.22-29
    • /
    • 2010
  • The concept of Ocean Thermal Energy Conversion (OTEC) is simple and various types of OTEC have been proposed and tried. However the location of OTEC is limited because OTEC requires $20^{\circ}C$ of temperature difference as a minimum, so most of OTEC plants were constructed and experimented in tropical oceans. To solve this we proposed the modified OTEC which uses condenser discharged thermal energy of existing fossil or nuclear power plants. We call this system CTEC (Condenser Thermal Energy Conversion) as this system directly uses $32^{\circ}C$ partially saturated steam in condenser instead of $20{\sim}25^{\circ}C$ surface sea water as heat source. Increased temperature difference can improve thermal efficiency of Rankine cycle, but CTEC should be located near existing plant condenser and the length of cold water pipe between CTEC and deep cold sea water also increase. So friction loss also increases. Calculated result shows the change of efficiency, pumping power, net power and other parameters of modeled 7.9 MW CTEC at given condition. The calculated efficiency of CTEC is little larger than that of typical OTEC as expected. By proper location and optimization, CTEC could be considered another competitive renewable energy system.

열사이펀의 열성능 산정을 위한 수치해석 연구 (Evaluation on Thermal Performance of Thermosyphon by Numerical Analysis)

  • 장창규;최창호;이장근;이철호
    • 한국지반공학회논문집
    • /
    • 제30권9호
    • /
    • pp.57-66
    • /
    • 2014
  • 동토지역에서는 계절변화에 상관없이 항시 영하상태로 동결되어 있는 영구동토층과, 그 위로 동결융해가 반복되는 활동층으로 구성되어있다. 일반적으로 대기온도 변화에 따라 동결융해가 반복되는 활동층은 얼음과 물의 상변화 작용이 반복되기 때문에 지반의 융기현상과 침하현상, 그리고 영구동토층의 온도상승을 초래할 수 있다. 열사이펀이란 구조체 내부에 충전된 냉매의 자가적인 열순환을 이용하여 지반의 온도를 영하상태로 제어하는 지반 안정화 공법 중 하나이다. 열사이펀은 대기중에 냉매의 열을 방출하는 응축부와 지중에 열을 흡수하는 증발부로 구성되어 있으며 대기의 온도가 영하의 상태일 때 지반의 온도를 영하상태로 제어한다. 본 연구에서는 열사이펀의 지반 열전달성능을 분석하기 위해 모형지반에 단열재를 배치하여 열사이펀을 통한 지반동결실험을 수행하였다. 단열재의 열차단성 및 열사이펀 길이를 고려하여 단열재 및 열사이펀의 성능실험을 수행하였으며, 실험에서 얻어진 물성치를 상용수치해석 프로그램인 TEMP/W에 반영하였다. 본 연구에서 제시된 실내실험과 수치해석 방법을 통해 열사이펀의 열성능을 산정할 수 있었다.

대체냉매 R-410A를 적용한 냉난방기 운전성능 실험연구 (Experimental Study on Operation Performance of Cooling and Heating A/C using R-410A)

  • 엄유식;박경만;권영철;이상재
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2009년도 추계학술발표논문집
    • /
    • pp.889-892
    • /
    • 2009
  • 본 연구에서는 R-22와 R-410A를 사용하는 냉난방기의 성능 및 사이클 특성을 조사하기 위하여, R-22와 R-410A를 적용한 냉난방기의 성능을 비교 실험하였다. 이를 위하여 R-22와 R-410A 냉난방기 사이클을 구성하였으며, 냉난방기 시스템의의 성능을 측정하기 위하여 공기엔탈피식 칼로리미터를 사용하였다. 실험을 통해 냉난방 온도조건에서 능력, 소비전력, 온도, 압력 등을 측정하였다. 본 연구결과는 R-410A의 냉난방기 사이클 적용 가능성을 보여주었다. 한편, 실험으로부터 획득된 데이터는 R-410A 냉난방기 개발시 기초 설계자료 및 시스템의 효율향상을 위한 방안으로 활용될 것이다.

  • PDF

Gas 냉매를 활용한 신기술 냉각방식 주변압기 현장 실증적용 (The real application of main transformer adopted by new cooling system equipped with gas refrigerant)

  • 김진환;박한우;강구호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.322-324
    • /
    • 2008
  • 현재 배전용변전소 대용량변압기 냉각방식은 주로 유입자냉식, 유입풍냉식, 송유풍냉식 및 수냉각 방식이 채용되고 있다. 유입풍냉식의 경우는 대기 공기의 자연대류 또는 냉각팬에 의한 강제대류에 의해 방열기 내부로 유입된 절연유의 온도를 낮추는 방식이고 송유풍냉식은 변압기 내부 절연유를 강제순환 시키면서 냉각팬을 가동하는 방식이다. 도심지 복합건물내 주변압기 냉각은 수냉식을 채용하여 절연유를 강제로 순환시키면서 열교환기 2차측에 냉각수를 순환시켜 열교환기 내로 유입된 절연유의 온도를 낮추는 방식이다. 그러나 도심지 변전소의 냉각방식 채택에 있어 냉각성능, 소음, 설비의 건전성등 여러 가지 문제점이 드러나 새롭고 획기적인 냉각방식이 요구되고 있다.

  • PDF

자동차 $CO_2$ 냉방시스템의 고압과 실내온도의 효과적인 제어를 위한 지능알고리즘 (Intelligent Algorithms for the Effective Control of High-side Pressure and Indoor Air Temperature of a $CO_2$ Automotive Air Conditioner System)

  • 장경창;한도영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.480-485
    • /
    • 2005
  • In the respect of the environmental protection viewpoint, the $CO_2$ may be regarded as one of the most attractive alternative refrigerants for an automotive air-conditioning system. Control methods for a $CO_2$ system should be newly developed, because properties of $CO_2$ are different compared with those of classical refrigerants. Especially, high-side pressure of a $CO_2$ system should be controlled for the effective operation of the system. In this study, intelligent control algorithms for a $CO_2$ system were developed ‘ These are a high-side pressure control algorithm and an indoor air temperature control algorithm. These algorithms were analysised by using dynamic models of a $CO_2$ system.

  • PDF

Subcooling Bypass Technology를 적용한 압축기 토출 냉매 온도 감소에 관한 연구 (A Study on the Decrease of Compressor Discharge Temperature Using Subcooling Bypass Technology)

  • 곽경민;배철호
    • 설비공학논문집
    • /
    • 제21권6호
    • /
    • pp.326-332
    • /
    • 2009
  • The purpose of the study is to decrease the refrigerant temperature at the outlet of the compressor under high thermal load conditions for air cooled vapor compression refrigeration system. The subcooling bypass line called subcooling bypass technology(SBT) is installed to the window type A/C system to investigate the performance test. The standard air calorimeter test method is applied to measure the refrigerant temperature at the outlet of the compressor, cooling capacity, power consumption, and system EER. The refrigerant temperature at the outlet of the compressor decreases as the bypass rate increases. When the bypass rate is 8.2%, the refrigerant temperature at the outlet of the compressor decreases $2.8^{\circ}C$ while the cooling capacity and EER are the same as the conventional A/C unit.

제습기를 이용한 온실 포그냉방시스템의 효율향상 (Improvement of Cooling Efficiency in Greenhouse Fog System Using the Dehumidifier)

  • 남상운;김기성
    • 생물환경조절학회지
    • /
    • 제14권1호
    • /
    • pp.29-37
    • /
    • 2005
  • 본 연구는 온실에서의 제습장치 이용에 관한 기초자료를 제공할 목적으로 지하수를 냉매로 하는 열교환기 방식의 제습장치를 제작하여 제습성능을 시험하고, 포그냉방시스템을 설치한 온실에 적용하여 제습이 증발냉각효율의 향상에 미치는 영향을 분석하였으며, 그 결과를 요약하면 다음과 같다. 제습기 성능실험 결과 지하수를 냉매로 이용할 경우 포그냉방시스템을 적용한 온실의 제습은 충분히 가능한 것으로 확인되었다. 냉방 온실의 기온을 $32^{\circ}C$로 설정할 때 냉매인 지하수의 온도가 $15^{\circ}C$에서 18, 21, $24^{\circ}C$로 높아지면 제습량은 각각 $17.7\%,\;35.4\%,\;52.8\%$ 감소하는 것으로 나타났다. 또한 지하수 유량을 $75\%,\;50\%$로 줄이면 제습량은 각각 $12.1\%,\; 30.5\%$ 감소하는 것으로 나타났다. 이러한 결과로 미루어 볼 때 지하수를 이용한 제습기의 설계에 있어서 이용 가능한 유량과 온도가 중요한 인자임을 알 수 있다. 포그냉방 온실에 제습기를 설치함으로서 뚜렷한 냉방효율 개선을 확인할 수 있었다. 환기율 0.7 회${\cdot}min^{-1}$정도의 자연환기 상태에서 포.1냉방 온실의 환기에 의한 제습율은 53.9%~74.4%였으며, 제습기를 가동할 경우 75.4~95.9까지 높아졌다. 제습기 설계유량과 $18^{\circ}C$의 지하수를 사용할 경우 0.36회 ${\cdot}min^{-1}$ 정도의 환기율에서도 포그시스템 작동으로 인하여 발생하는 분무량을 완전히 제거할 수 있는 것으로 분석되었다. 따라서 제습기를 이용하여 자연환기 온실에서의 포그 냉방 효율을 충분히 높힐 수 있을 것으로 판단되었다.

새로운 CO2 오토 캐스케이드 열펌프 시스템의 성능특성 연구 (Study on the performance characteristics of a new CO2 auto-cascade heat pump system)

  • 윤상국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제41권3호
    • /
    • pp.191-196
    • /
    • 2017
  • 20세기에 대두된 HCFC나 CFC계의 냉매들의 환경에의 악영향을 극복하기 위하여 보다 환경 친화적인 이산화탄소와 같은 자연냉매에 대한 관심이 커지고 있다. 겨울철 대기의 열원을 이용하여 증발을 유도하는 이산화탄소 열펌프는 증발기의 온도가 높아 효율이 상대적으로 낮아지고, 130bar가 넘는 고압으로 인하여 열펌프 설비 부품들의 제작의 어려움이 따르게 된다. 본 연구는 보다 낮은 압력의 새로운 2단 팽창식 $CO_2$ 오토 캐스케이드 열펌프를 고안하여 이러한 단점들을 해소하고 보다 효율을 증가시키고자 하였다. 새로운 오토 캐스케이드 열펌프에 2단 팽창방식과 효과적인 냉각방식의 시스템 구성을 하여 혼합냉매인 $CO_2$ 와 R32를 적용하였다. 공정에 고압 70bar, 중간 팽창압은 25bar, 최종 저압은 10bar를 적용하여 해석한 결과, 현재의 오토 캐스케이드 열펌프 공정의 COP는 1.629이었으나, 개선된 중간 압력 25bar의 2단 팽창 오토 캐스케이드 공정은 2.332로 현재의 공정보다 43.15% 향상되었다. 또한 저압측 증발기의 온도도 $-10^{\circ}C$ 이하가 되어 찬 외기에도 증발이 용이하게 발생되는 공정이 되었다. 본 공정이 향후 $CO_2$ 열펌프의 성능계수를 보다 향상시키고 고압에 따른 부품 문제들의 해소에 기여할 수 있는 공정으로 분석되었다.

CFD를 활용한 선박고온도차발전용 WHRU의 열유동 해석에 관한 연구 (A Study on the Thermal Flow of Waste Heat Recovery Unit (WHRU) for Ship's Organic Rankine Cycle Power Generation System using CFD Method)

  • 황대중;박상균;지재훈;방은신;오철
    • 해양환경안전학회지
    • /
    • 제27권5호
    • /
    • pp.647-655
    • /
    • 2021
  • IMO에서는 선박으로부터 온실가스 감축을 위해 선박의 에너지효율 증진에 관한 논의를 진행하고 있다. 현재, 선박으로부터 발생되는 폐열을 이용한 ORC 발전 시스템을 적용함으로써 선박으로부터 높은 에너지 변환 효율을 기대할 수 있다. 이 기술은 물보다 더 낮은 온도 범위에서 증발하는 프레온 또는 탄화수소 계통의 유기 매체를 작동 유체로 사용한다. 이를 통해 상대적으로 낮은 저온에서 증기(기체)를 생성 및 동력을 발생시킬 수 있다. 본 연구에서는 유기 랭킨 사이클인 ORC 발전 시스템에서 냉매와 폐열 사이 열·유동해석(Analysis of Heat flow)을 3D 시뮬레이션 기법을 이용하여 구조물의 내·외부에 흐르는 유체가 온도 변화, 속도 변화, 압력 변화 및 질량 변화를 통해서 구조물에 어떤 영향을 미치는지를 분석하고자 하며, 동 연구는 이 기법을 이용하여 ORC 발전 시스템에서 냉매와 선박 주기관의 배기가스로부터 일어나는 열교환기의 열전달을 해석하였다.

LNG 선박 하이브리드 엔진 및 해수 담수화 복합 시스템 (LNG-Vessels Hybrid Engine Seawater Desalination Complex System)

  • 임재준;이동헌;변기식;김관형
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.663-664
    • /
    • 2016
  • 해수를 이용한 온도차 발전은 심층수와 표층수의 온도 차이를 이용한 암모니아(냉매)를 사용하여 폐쇄적인 액화와 기화를 반복하여 터빈을 돌리는 방식이다. 온도차 발전의 특성상 온도 차이가 클수록 에너지 발전 특성은 좋아진다. 이는 심층수 표층수의 온도차이가 커야 됨을 이야기 한다. 하지만 겨울이 되면 표층수와 심층수의 온도차이가 크지 않아 에너지 효율이 떨어지는 문제점이 있다. 그리고 해수 담수화기술은 지구의 97%를 차지하지만 우리가 먹을 수 없는 바닷물을 담수로 바꾸는 기술로, 해수 담수화기술로 생산된 담수는 선박내의 공업, 식수 등 각종 용수로 사용할 수 있다. 본 논문에서는 현재 문제가 되고 있는 계절에 따른 표층수의 온도 변화를 개선하기 위해 기존에 사용하고 있는 선박용 디젤엔진의 열에너지와 LNG의 냉열 에너지를 사용한 온도차 발전을 위해 LNG 운송 선박을 기준으로 LNG 운송 선박 하이브리드 엔진에 관한 연구와 냉열 에너지를 활용한 해수 냉동법으로 담수화하는 발전 및 담수화를 복합시킨 연구를 제시하고자 한다.