Effects of Refrigerant Subcooling on the Performance of indirectly Ice Thermal Storage Cooling System (축열조 간접이용 냉매 과냉각형 시스템에서 과냉도가 시스템 성능에 미치는 영향)

  • Lee, Soo-Yang;Park, Shung-Sang;Peck, Jong-Hyeon;Chung, Dong-Yeol;Park, Il-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.979-983
    • /
    • 2009
  • This study has been conducted the possibility of the subcooling type ice storage cooling system that the stored ice used to subcool the condensed refrigerant. The experimental study was done to fine the characteristics of the cooling capacity according to the variation of the subcooling degree and the analysis for the peak shift effect of the full storage, partial storage and subcooling type ice storage system compared to the normal air conditioning system was also done. The result of the analysis was shown that the peak shift effect of this subcooling type ice storage system could be 61%.

  • PDF

Exergy Analysis of R744-R404A Cascade Refrigeration System (R744-R404A용 캐스케이드 냉동시스템의 엑서지 분석)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1001-1008
    • /
    • 2011
  • This paper describes an analysis on performance and exergy of R744-R404A cascade refrigeration system with internal heat exchanger to optimize the design for the operating parameters of this system. The operating parameters considered in this study include subcooling and superheating degree, internal heat exchanger and compression efficiency, evaporation and condensation temperature in the R744 low- and R404A high- temperature cycle, respectively. The main results are summarized as follows : As the evaporation temperature of cascade heat exchanger increases, the COP of R404A high-temperature cycle increases. But the COP of R744 low-temperature cycle decreases, and the COP of total cascade cycle is almost constant. As cascade evaporation temperature increase, the exergy loss in the R404A condenser and the R744 internal heat exchanger is the largest and the lowest among all components, respectively. Therefore, the exergy loss in the condenser and compressor of R404A must be decreased to enhance the COP of R744-R404A cascade refrigeration system.

Development of a New Commercial Grain Cooler (곡물냉각기의 개발)

  • 김동철;김의웅;금동혁;한종규
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.250-256
    • /
    • 2004
  • The objectives of this study were to develop a new commercial grain cooler suited to domestic weather and post-harvesting conditions for paddy, and to evaluate the performance. A prototype grain cooler capable of cooling paddy of 200 tons within 24 hours was developed. The grain cooler was designed to control the refrigeration capacity from 0 to 100% by controlling the capacity of compressor with unloading solenoid valve and by changing the flow rates of hot refrigerant gas flowing into reheater and evaporator from compressor. And a controller with one chip microprocessor was developed to control temperature and relative humidity of cooling air. The maximum cooling capacity of the grain cooler was 35,284㎉/hr at condensing/evaporating pressure of 16.5/3.6 kgf/$\textrm{cm}^2$. Maximum flow rate of cooling air was 120 ㎥/min at static pressure of 279 mmAq. The total maximum required power was 22.8㎾, and total required energy was saved from 26.7 to 33.3% of maximum power depending on operating conditions. The coefficient of performance of refrigeration devices and total coefficient of performance of the grain cooler were 4.71 and 1.8, respectively.