• Title/Summary/Keyword: 냉동효율

Search Result 217, Processing Time 0.021 seconds

Development of machine learning model for reefer container failure determination and cause analysis with unbalanced data (불균형 데이터를 갖는 냉동 컨테이너 고장 판별 및 원인 분석을 위한 기계학습 모형 개발)

  • Lee, Huiwon;Park, Sungho;Lee, Seunghyun;Lee, Seungjae;Lee, Kangbae
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.1
    • /
    • pp.23-30
    • /
    • 2022
  • The failure of the reefer container causes a great loss of cost, but the current reefer container alarm system is inefficient. Existing studies using simulation data of refrigeration systems exist, but studies using actual operation data of refrigeration containers are lacking. Therefore, this study classified the causes of failure using actual refrigerated container operation data. Data imbalance occurred in the actual data, and the data imbalance problem was solved by comparing the logistic regression analysis with ENN-SMOTE and class weight with the 2-stage algorithm developed in this study. The 2-stage algorithm uses XGboost, LGBoost, and DNN to classify faults and normalities in the first step, and to classify the causes of faults in the second step. The model using LGBoost in the 2-stage algorithm was the best with 99.16% accuracy. This study proposes a final model using a two-stage algorithm to solve data imbalance, which is thought to be applicable to other industries.

UF/MF막의 국내 적용사례

  • 김정학
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.06a
    • /
    • pp.171-221
    • /
    • 1998
  • 막분리기술은 이제 분리, 정제만의 단순한 개념이 아니며 고도분리정제와 자원재활용등이 복합적으로 해결되는 효율적 공정으로서 "Zero discharge" 및 "Closed-loop System" 으로서의 개념을 가지고 있다. 이것은 Clean Technology의 개념으로서 Membrane기술의 향후 Vision이라고 할 수 있다. 국내에 적용되고 있는 UF/MF막의 용도는 다음과 같다. -수처리분야, 가정용정수기, 폐수처리분야, 식품/생물공정 분야, 전착도장, 흡수식 냉동기의 LiBr 용액정제, 흡수식 냉동기의 LiBr 용액정제

  • PDF

Status of Packaging Materials for Frozen Foods and Analysis of Temperature Changes inside Packaging Materials during Frozen Process (냉동식품용 포장재 현황 및 냉동 과정 중 포장재 내부 온도 변화에 관한 연구)

  • Yoo, Seungwoo;Kwon, Sangwoo;Park, Su-il
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.25 no.1
    • /
    • pp.11-16
    • /
    • 2019
  • This study analyzed various packaging materials and types for frozen foods and the effects of packaging materials on temperature changes during frozen process. Pouches with different film thickness were prepared and placed in an IQF freezer, then the temperature inside pouches measured using a deep thermometer. The most common types of primary packaging for frozen foods in the market was plastic pouches with polyethylene or polyamide/polyethylene multilayer materials. The temperature change inside of packaging was delayed with film thickness increased. As the size of packaged food increased, the temperature change inside the food was slowed down. In addition, the pouches with air inside took more time to reach $-30^{\circ}C$ compared to pouches with less air during frozen process. This study provides information on packaging materials and types for frozen foods and preliminary data of temperature change by different types of packaging.

Optimal Design Condition of Refrigeration Cycle with Heat Transfer Processes (열전달을 고려한 냉동 사이클의 최적 설계조건)

  • 김수연;정평석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.225-229
    • /
    • 1990
  • As a basic study of optimal design conditions of refrigeration systems, the reversed carnot cycle, including heat transfer processes through the finite temperature differences between heat sources and the working fluids, is analyzed with the capacity of heat exchanger as a design parameter. When the temperatures of heat sources and the input work are fixed as constants, the optimal design condition is obtained as an optimum ratio of capacities of heat exchangers, which is exactly unity when the exergy output and effectiveness are maximum. In addition, the optimum ratio is slightly increased from unity as the irreversibility of the cycle increases.

An Introduction and Technical Review for Screw Compressor Chiller (스크류 냉동기의 소개와 국내외 기술동향)

  • 권병렬
    • Journal of the KSME
    • /
    • v.33 no.11
    • /
    • pp.973-978
    • /
    • 1993
  • 스크류 냉동기의 특징은 CFC계 냉매를 사용하지 않고도 -60.deg. C까지 무난하게 온도를 내릴 수 있어 대체 물질의 사용기술이 취약한 국내사정에 빛추어 볼 때 상당한 시간을 벌 수가 있다. 또한 다른 방식의 압축기에 비해 고효율 운전을 할 수가 있다. 스크류냉동기에서 핵심 부품인 스크류 압축기는 1878년 독일의 Krigar에 의해 원리가 정립되었고, 1934년 스웨덴의 A. Lysholam에 의해 공기 압축기로써 상품화가 되었다. 가까운 일본에서는 1955년 스웨덴의 SRM 사로부터 기술을 도입하여 상품화를 시작하였다. 국내는 1970년대부터 스크류 압축기를 외국으 로부터 수입하고 기타 부속품은 국내에서 제작하는 정도로 성장하고 있다가, 1968년에 K사에서 스웨덴의 SRM사로부터 기술을 도입하여 1단 압축 스크류 냉매압축기를 제작하기 시작하였고, 1991년부터 국내 기술로 2단 압축 반밀폐형 냉매 압축기의 연구 개발에 들어가 92년 말부터 상 품화를 성공시켰다. 이 글에서는 스크류 냉동기의 특징과 구성을 소개하고 특히 스크류 압축기의 원리 및 기술현황에 관하여 언급하고자 한다.

  • PDF

A Study of refrigerator cargo hold insulation design for Juice carrier ship (JUICE CARRIER 냉동 CARGO HOLD INSULATION 설계에 대한 연구)

  • Hong, Chang Hee;Lee, Jong Tae;Park, Tae ha
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2015.09a
    • /
    • pp.20-27
    • /
    • 2015
  • The juice carrier is the first ship built in korea. Special refrigerator system and cargo hold insulation with stainless steel tank were equipped on cargo hold. We studied optimum design of cargo hold insulation for reducing of ship building schedule and cost including good quality with refrigerating efficiency. From this study, general and newly specified juice carrier, technical method of cargo hold insulation system, air flow with division air wall, K-value calculation have been investigated.

  • PDF

Design and Implementation of a Mobile Framework for Efficient Inventory Management of Refrigerated Warehouses (효율적인 냉동창고 재고관리를 위한 모바일 프레임워크의 설계 및 구현)

  • Ban, ChaeHoon;Kim, DongHyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.2
    • /
    • pp.341-346
    • /
    • 2013
  • Refrigerated warehouse inventory management program which manages the logistics of shipping&receiving and inventory quickly and accurately is a costly and labor-intensive maintenance because it is operated in the legacy system on a closed client-server environment. There are no services available for consignees who are the consumers of refrigerated warehouses except fax or phone for orders which makes the business process inefficient and creates many problems such as error and inaccuracy. In this paper, we design and implement a mobile framework with a legacy system supporting various services to the consignees for solving problems of outdated legacy systems and no services to use. The system supports promptness and accuracy which give the users improved satisfaction by providing orders and queries of inventory for the consignees on mobile devices.

An Approach for Managing Storage Locations in RFID-Based Cold-Storage Warehouse System (RFID 기반 냉동창고 시스템의 적재위치 관리 방안)

  • Moon, Mi-Kyeong;Choi, Bong-Jun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.9
    • /
    • pp.1971-1978
    • /
    • 2011
  • In RFID-based cold-storage systems, product locations are recognized as the logical locations of RFID readers which are attached to the entrance of the cold rooms. However, through these methods, product locations can be incorrect in many different situations of a storage. Cold storage rooms have a huge rage in temperature, and the product in the cold-storage spoils easily. Therefore, highly precise product locations is very important for the product quality In this paper, a new approach is suggested to manage the storage location inaccuracy by adding two readers to existing forklift and attaching RFID tags to the ceiling. One reader recognizes ceiling tags to acquire location data, and the other recognizes product tags to acquire product detail data loaded on the forklift. The product can be seamlessly tracked and traced in realtime by monitoring and analyzing data gathered from these readers. Through the proposed location management method, the effectiveness of the product management in cold-storage can be improved consequently.

Development of cascade refrigeration system using R744 and R404A - Prediction and comparison on maximum COP(Coefficient of Performance) - (R744-R404A용 캐스케이드 냉동시스템 개발에 관한 연구(2) - 최대 성능계수에 관한 예측과 비교 -)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.189-195
    • /
    • 2011
  • In this paper, prediction and comparison on COP(coefficient of performance) of R744-R404A cascade refrigeration system are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, compressor efficiency, and condensing and evaporating temperature in the R404A high- and R744 low-temperature cycle, respectively. The main results were summarized as follows : The prediction for performance of R744-R404A cascade refrigeration system have been proposed through multiple regression analysis and compared with other researcher's correlations. As a result, prediction proposed in the study shows disagreement with existing equations. Therefore, it is necessary to propose the more accurate correlation predicting the COP of R744-R404A cascade refrigeration system through an addition experiments.

Performance analysis for load control of R744(carbon dioxide) transcritical refrigeration system using hot gas by-pass valve (핫가스 바이패스 밸브를 이용한 R744용 초임계 냉동사이클의 부하제어에 대한 성능 분석)

  • Roh, Geun-Sang;Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2189-2194
    • /
    • 2009
  • The automatic hot gas by-pass technique is applied to control the capacity of refrigeration and air-conditioning system when operating at part load. In the scheme, the hot gas from the compressor is extracted and injected into the outlet of an evaporator through a hot gas by-pass valve. Thus, In this paper, the hot gas by-pass scheme for CO2 is discussed and analyzed on the basis of mass and energy conservation law. A comparative study of the schemes is performed in terms of the coefficiency of performance (COP) and cooling capacity. The operating parameters considered in this study include compressor efficiency, superheating degree, outlet temperature of gas cooler and evaporating temperature in the R744 vapor compression cycle. The main results were summarized as follows : the superheating degree, outlet temperature and evaporating temperature of R744 vapor compression refrigeration system have an effect on the cooling capacity and COP of this system. With a thorough grasp of these effect, it is necessary to design the compression refrigeration cycle using R744.