• Title/Summary/Keyword: 냉동필터법

Search Result 2, Processing Time 0.015 seconds

Application of Freezing Filtration Method to the Analysis of Alkylphenols, Chlorophenols and Bisphenol a in Korean Aquatic Biological Samples Using GC/MS-SIM (GC/MS-SIM을 이용한 우리나라 수중 생물시료 중 알킬페놀, 클로로페놀과 비스페놀 A의 분석을 위한 냉동필터법의 응용)

  • Kim, Hyub;Jang, Cheol-Hyeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.6
    • /
    • pp.689-698
    • /
    • 2007
  • A new technique was proposed for the determination of alkylphenols, chlorophenols and bisphenol A in korean aquatic biological samples. The alkylphenols, chlorophenols and bisphenol A in korean aquatic biological samples were extracted with acetonitrile and then acetonitrile layer was refrigerated at $-60^{\circ}C$ for 2 hours(freezing filtration method). Also, solid-phase extraction(SPE) was used to XAD-4 and subsequent conversion to isobutoxycarbonyl(isoBOC) or tert-butyldimethylsilyl(TBDMS) derivatives for sensitive analysis with gas chromatography/mass spectrometry-selected ion monitoring(GC/MS-SIM) mode. For isoBOC derivatization and TBDMS derivatization the recoveries were $70.1\sim150.6%$ and $93.8\sim108.3%$, the method detection limit(MDLs) of bisphenol A for SIM were $0.062{\mu}g/kg$ and $0.010{\mu}g/kg$, and the SIM respectively. When these methods were applied to korean aquatic biological samples, the concentrations of the 11 phenolic EDCs were $0.675\sim1.970{\mu}g/kg$.

Study on simultaneous determination of aromatic material causing allergic in children's products by GC-MSD (GC-MSD를 이용한 어린이 제품 중 알러지 유발 방향성 물질의 동시분석법 연구)

  • Ko, Kyeong Mok;Rhu, Chan Joo;Ko, Byeong Rae;Lee, Seok Ki
    • Analytical Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.134-142
    • /
    • 2020
  • Twenty-one allergy-induced aromatic material in children's products were analyzed using gas chromatography mass spectrometer(GC-MSD). The analytes were extracted using an automatic Soxhlet extractor, centrifuged for 10 minutes in a fast freezing centrifuge, and the supernatant was filtered with a syringe filter and then transferred into a 2 mL vial and injected in a split mode. In the established condition, the calibration curve showed linearity with a determination coefficient of 0.9981 or more. Sensitivity was 0.3145 ~ 1.6757, which showed a fairly wide range of sensitivity for each substance. The detection limit of the device was 0.0016 ~ 0.0423 ㎍/mL and the maximum detection limit was less than 0.05 ㎍/mL. The method detection limit ranged from 0.0030 ~ 0.0589 ㎍/mL. In addition, the limit of quantification ranged from 0.0096 to 0.1876 ㎍/mL, with precision ranging from 0.41 to 10.49 % and accuracy ranging from 83 to 116 %. The analytical method developed in this study was applied to commercial products.