• Title/Summary/Keyword: 냉각 회로

Search Result 279, Processing Time 0.024 seconds

Thermal Analysis of 3D Multi-core Processors with Dynamic Frequency Scaling (동적 주파수 조절 기법을 적용한 3D 구조 멀티코어 프로세서의 온도 분석)

  • Zeng, Min;Park, Young-Jin;Lee, Byeong-Seok;Lee, Jeong-A;Kim, Cheol-Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.11
    • /
    • pp.1-9
    • /
    • 2010
  • As the process technology scales down, an interconnection has became a major performance constraint for multi-core processors. Recently, in order to mitigate the performance bottleneck of the interconnection for multi-core processors, a 3D integration technique has drawn quite attention. The 3D integrated multi-core processor has advantage for reducing global wire length, resulting in a performance improvement. However, it causes serious thermal problems due to increased power density. For this reason, to design efficient 3D multi-core processors, thermal-aware design techniques should be considered. In this paper, we analyze the temperature on the 3D multi-core processors in function unit level through various experiments. We also present temperature characteristics by varying application features, cooling characteristics, and frequency levels on 3D multi-core processors. According to our experimental results, following two rules should be obeyed for thermal-aware 3D processor design. First, to optimize the thermal profile of cores, the core with higher cooling efficiency should be clocked at a higher frequency. Second, to lower the temperature of cores, a workload with higher thermal impact should be assigned to the core with higher cooling efficiency.

A Study of the Fiber Fuse in Single-mode 2-kW-class High-power Fiber Amplifiers (단일 모드 2 kW급 고출력 광섬유 증폭기 내의 광섬유 용융 현상에 관한 연구)

  • Lee, Junsu;Lee, Kwang Hyun;Jeong, Hwanseong;Kim, Dong Jun;Lee, Jung Hwan;Jo, Minsik
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.1
    • /
    • pp.7-12
    • /
    • 2020
  • In this paper, we experimentally investigate the fiber fuse in single-mode 2-kW-class high-power fiber amplifiers, depending on the cooling method at the splicing point. We measured the temperature of the splicing point between the pump-signal combiner and gain fiber as a function of laser output power. The temperature of the splicing point increased from 20 to 32℃ with a slope of 0.01℃/W, up to 1.2 kW of laser output power. At higher powers the temperature of the splicing point increased dramatically, with a slope of 0.08℃/W. After that, the fiber amplifier was destroyed during operation at 1.96 kW of output power by fiber fuse. The bullet shape, a common feature of fiber fuse, was observed in the damaged passive fiber core of the pump-signal combiner. Later, we adopted an improved water-cooled cold plate to increase the cooling efficiency at the splicing point, and investigated the laser output power. The temperature at the splicing point was 35.8℃ with a temperature-rise slope of 0.007℃/W at the maximum output power of 2.05 kW. The beam quality M2 was measured to be less than 1.3, and the output beam's profile was a stable Gaussian shape. Finally, neither fiber fuse nor mode instability was observed in the fiber amplifier at the maximum output power of 2.05 kW.

A study of thermoelectric Heat Pump device (열전소자를 이용한 히트펌푸에 관한 연구)

  • 박창엽
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.5 no.1
    • /
    • pp.6-12
    • /
    • 1968
  • Experiments have been made on alloys to determine the practicability of using the Peltier effect in a thermoelectric devices. The cooling and heating results of thermoelectrie material coposed of n and p type BiTe are used, whose properties are; , , , , and K: thermal conductivity. The temperature of the cold part has been measured in veccum with respect to the temperature of the hot part. The experiment result agreed fairly with expectation such as was 42 degree C.

  • PDF

Thermal stability of superconducting systems conduction-cooled by cryocooler (극저온냉동기로 전도냉각되는 초전도시스템의 열적 안정성)

  • 권기범;장호명
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.56-63
    • /
    • 2001
  • The thermal stability conditions are investigated for superconducting magnet systems cooled conductively by cryocooler without liquid cryogens. The worst scenario in the systems is that the heat generation in the resistive state exceeds the refrigeration. causing a rise in the temperature of the magnet winding and leading to the burnout. It is shown by an analytical solution that in the continuous resistive state, the temperature may increase indefinitely or a stable steady-state may be reached, depending upon the relative size of the magnet with respect to the refrigeration capacity of the cryocooler. The stability criteria include the temperature-dependent Properties of the magnet materials and the refrigeration characteristics of the cryocooler. A useful graphical scheme is Presented and discussed to demonstrate the physical importance of the results.

  • PDF

Small Camera Module for TEC-less Uncooled Thermal Image (TEC-less 비냉각 열영상 검출기용 소형카메라 모듈 개발)

  • Kim, Jong-Ho
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.12 no.2
    • /
    • pp.97-103
    • /
    • 2017
  • Thermal imaging is mainly used in military equipment required for night observation. In particular, technologies of uncooled thermal imaging detectors are being developed as applied to low-cost night observation system. Many system integrators require different specifications of the uncooled thermal imaging camera but their development time is short. In this approach, EOSYSTEM has developed a small size, TEC-less uncooled thermal imaging camera module with $32{\times}32mm$ size and low power consumption. Both domestic detector and import detector are applied to the EOSYSTEM's thermal imaging camera module. The camera module contains efficient infrared image processing algorithms including : Temperature compensation non-uniformity correction, Bad/Dead pixel replacement, Column noise removal, Contrast/Edge enhancement algorithms providing stable and low residual non-uniformity infrared image.

Fan Noise Prediction Method of Air Conditioning and Cooling System (공기조화 및 냉각시스템의 팬 소음예측 기법)

  • Lee, Jin-Young;Lee, Chan;Kil, Hyun-Gwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1318-1320
    • /
    • 2007
  • Fan noise prediction method is presented for air conditioning and/or cooling system applications where fan acts as an internal equipment having very complicated flow interaction with other various system components. The internal flow paths and distribution in the fan-applied systems such as computer or air conditioner are analyzed by using the FNM(Flow Network Modeling) with the flow resistances for flow elements of the system. Based on the fan operation point predicted from the FNM analysis results, the present fan noise model predicts overall sound power, pressure levels and spectrum. The predictions of the flow distribution, the fan operation and the noise level in electronic system by the present method are well agreed with 3-D CFD and actual noise test results.

  • PDF

Fan Noise Prediction Method of Air Cooling System (공기 냉각 시스템의 홴 소음 예측 기법)

  • Lee, Chan;Kil, Hyun-Gwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.9
    • /
    • pp.952-960
    • /
    • 2008
  • Fan noise prediction method is presented for air conditioning, automobile and electronic cooling system applications where fan acts as an internal equipment having very complicated flow interaction with other various system components. The internal flow paths and distribution in the fan-applied systems such as computer or air conditioner are analyzed by using the FNM(flow network modeling). Fan noise prediction method comprises two models for the discrete frequency noise due to rotating steady aerodynamic lift and blade interaction and for the broadband noise due to turbulent boundary layer and wake vortex shedding. Based on the fan operation point predicted from the FNM analysis results and fan design parameters, the present far noise model predicts overall sound pressure level and spectrum. The predictions for the flow distribution, the fan operation and the noise level in air cooling system by the present method are well agreed with 3-D CFD and actual noise test results.

The Neutron Dose Estimation of Hot Cell Shield Wall (핫셀 차폐벽의 중성자 선량평가)

  • 조일제;주준식;국동학;구정회;정원명;유길성;이은표
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.228-228
    • /
    • 2003
  • 차세대관리 종합공정에서 취급되는 기준 방사선원은 경수로에서 배출된 우라늄-235 농축도 3.5 wt%, 연소도는 43 Gwd/tU 이며 냉각기간은 10년인 사용후핵연료이다. 사용후핵연료의 기준 사양과 차세대관리 종합공정의 특성에 따라 최대 1,385 TBq의 방사선원이 핫셀내에 존재하게 되며, 핫셀 차폐벽은 총 방사능량에 대한 차폐능을 가져야 한다. 최대 방사선원에 대한 핫셀 차폐벽의 중성자에 대한 차폐능을 평가하기 위하여, 본 연구에서는 ORIGEN-2 코드를 이용하여 사용후핵연료에서 발생하는 핵종 및 핵종량을 평가하였으며, 이 자료를 기초로 하여 중성자 선원항을 SOURCES코드를 이용하여 계산하였다.

  • PDF

Evaluation of High Temperature Structural Integrity of Intermediate Heat Exchanger in a Steady State Condition for PGSFR (PGSFR중간열교환기의 정상상태 고온 구조 건전성 평가)

  • Lee, Seong-Hyeon;Koo, Gyeong-Hoi;Kim, Sung-Kyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.107-114
    • /
    • 2016
  • Four cylindrically shaped IHXs(Intermediate Heat Exchangers) are installed in the PHTS(Primary Heat Transfer System) of the PGSFR(Prototype Gen IV Sodium cooled Fast Reactor). As for the IHX, the temperature difference of structure is inevitable result caused by heat transfer between primary coolant sodium and IHTS(Intermediate Heat Transport System) sodium. It is necessary to evaluate the high temperature structural integrity of IHXs which operate at the elevated temperature condition over the creep temperature. In this paper, the high temperature structural integrity of IHX under assumed loading conditions has been reviewed according to ASME code.

Preparation of potassium hexathiocyanatochromate (Potassium hexathiocyanatochromate (III)의 제조에 관한 실험)

  • 최종인
    • YAKHAK HOEJI
    • /
    • v.13 no.1
    • /
    • pp.38-42
    • /
    • 1969
  • Chloropentammine chromium(III) chloride를 출발물질로 하여 여러가지의 thiocyanatoammine계 착화합물을 합성하는 실험에 있어서 그 수득량이 예상보다 매우 적고 그 염의 모액이 농적자색이라는 점으로 보아 그 모액중에 어떠한 다른 착화합물이 다량 형성되어 있으리라고 추측하여 그 분리를 시도하였다든바 미려한 적자색의 결정을 얻었다. 그리고 분석에 의하여 이 물질이 potassium hexathiocyanatochromate(III) 임을 증명하였다. Cr$^{+++}$ 의 thiocyanate 착화합물형성에 관하여는 Niel Bjerrm$^{(8)}$에 의한 보고문이 있고 또 이들의 제법으로서는 Roesler$^{(9)}$들에 의하여 Potassium chromium alum에서부터 이 물질을 만드는 방법만이 보고되어 있을뿐이다. 따라서 Chloropentammine chromium(III) chloride에서 부터 이 물질을 만드는 이 새로운 방법이 이러한 화합물들의 제법으로서 앞으로 이용될 수 있는것으로 사료한다. 제조 방법: Chloropentammine chromium(III) chloride 3g을 KSCN 24g, 빙초산 24ml및 물 48ml의 혼합수용액에 현탁시킨 혼합물을 처음에는 잘 교반하면서 가온하고 다음 완전히 용해될때까지 끊인다. 냉각시킨 다음 생성된 증황색의 침반 Thiocyanatopentammine chromium(III) thiocyanate를 여과하고 여액 65ml에 KSCN 50g을 추가하여 완전용해시킨다. 이 용액을 방냉시키면 적자색의 미려한 결정이 석출되므로 이 결정을 여과하여 ethanol로 세척하고 진공 desiccator중에서 건조시켰다. 수득량 1.2~1.3g.