• Title/Summary/Keyword: 냉각 최적화

Search Result 161, Processing Time 0.022 seconds

Analytical, Numerical, and Experimental Comparison of the Performance of Semicircular Cooling Plates (반원형 구조의 냉각판 성능에 관한 해석적/수치해석적/실험적 비교)

  • Cho, Kee-Hyeon;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1325-1333
    • /
    • 2011
  • An analytical, numerical, and experimental comparison of the hydraulic and thermal performance of new vascular channels with semicircular cross sections was conducted. The following conditions were employed in the study: Reynolds number, 30-2000; cooling channels with a volume fraction of the cooling channels, 0.04; and pressure drop, $30-10^5$ Pa. Three flow configurations were considered: first, second, and third constructal structures with diameters optimized for hydraulic operations. To validate the proposed vascular designs by an analytical approach, 3-D numerical analysis was performed. The numerical model was also validated by the experimental data, and the comparison results were in excellent agreement in all cases. The validation study against the experimental data showed that compared to traditional channels, the optimized structure of the cooling plates could significantly enhance heat transfer and decrease pumping power.

A Study of Cooling Schedule Parameters on Adaptive Simulated Annealing in Structural Optimization (구조 최적화에서 적응 시뮬레이티드 애닐링의 냉각변수에 대한 연구)

  • Park, Jung-Sun;Jung, Suk-Hoon;Ji, Sang-Hyun;Im, Jong-Bin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.6
    • /
    • pp.49-55
    • /
    • 2004
  • The increase of computing power makes stochastic optimization algorithms available in structural design. One of the stochastic algorithms, simulated annealing algorithm, has been applied to various structural optimization problems. By applying several cooling schedules such as simulated annealing (SA), Boltzmann annealing (BA), fast annealing (FA) and adaptive simulated annealing (ASA), truss structures are optimized to improve the quality of objective functions and reduce the number of function evaluations. In this paper, many cooling parameters have been applied to the cooling schedule of ASA. The influence of cooling parameters is investigated to find the rules of thumb for using ASA. Tn addition, the cooling schedule combined with BA and ASA is applied to the optimization of ten bar-truss and twenty five bar-truss structure.

Optimizing the Configurations of Cooling Channels with Low Flow Resistance and Thermal Resistance (냉각유로 형상변화에 따른 유동 및 열저항 최적화 연구)

  • Cho, Kee-Hyeon;Ahn, Ho-Seon;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.1
    • /
    • pp.9-15
    • /
    • 2011
  • In this study, we investigated the hydrodynamic and thermal performance of constructal architectures on the basis of the mass flow rates for a given pressure drop, and we determined the thermal resistance and flow uniformity. The five flow configuration used in this study were the first construct with optimized hydraulic diameter, the second construct with optimized hydraulic diameter, the first construct with non-optimized hydraulic diameter, second construct with non-optimized hydraulic diameter, and a serpentine configuration. The results of our study suggest that the best fluid-flow structure is the second constructal structure with optimized constructal configurations. We also found that in the case of the optimized structure of cooling plates, the heat transfer was remarkably higher and the pumping power was significantly lower than those of traditional channels.

Optimization of Drying and Storage System for Paddy Using the Grain Cooler (곡물냉각기를 이용한 벼 건조 및 저장시스템의 최적화)

  • 김동철;김의웅
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.269-275
    • /
    • 2004
  • This study was conducted to develop an optimization model using Box's Complex Algorithm, and to determine optimum operating conditions to minimize costs for the drying and storage system using the grain cooler. To minimize the system operation cost, the optimum moisture contents after the first drying were found to be from 17.2 to 19.8 %. And optimum drying and cooling capacities were obtained. The combination of the dryer and grain cooler was found to be economical, showing enhancement of the drying capacity over 50%, and decrease of drying cost over 10%. When the circulating grain dryers of 6 and 20 ton/batch were used in conjunction with the grain cooler, the cost required for drying and storage system for paddy were 28,464∼33,317won/ton and 20,588∼26,511 won/ton, respectively, which was from 2.6 to 27.3% lower than that of conventional drying and storage system.

Optimization of Fan-Shaped Hole for Gas Turbine Blade on Thin Wall (가스터빈 블레이드의 얇은 벽에서의 팬 형상 홀 최적화)

  • Hyun, Minjoo;Park, Hee Seung;Kim, Taehyun;Song, Ho Seop;Lee, Hee Jae;Cho, Hyung Hee
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.4
    • /
    • pp.71-77
    • /
    • 2021
  • Several cooling techinques have been studied for protecting gas turbine blades from hot gas. In terms of film-cooling techniques, various shapes of film cooling holes have been studied including fan shaped holes, which are used on gas turbine blades. However, owing to increasing demands on smaller gas turbines, a research on film-cooling holes on thin walls is required. This study was conducted at blowing ratios of 1 and 2, using numerical analysis. Through the numerical analysis, the effect of geometrical parameters on the effectiveness of fan-shaped hole film cooling was studied. Moreover, optimization was performed on three geometrical parameters: metering length, lateral expansion angle and forward expansion angle. As a result, we realized that the optimal fan-shaped holes on each blowing ratio were found to have very similar geometry and cooling performance.

Modified Simulated Annealing Algorithms for Optimal Seismic Design of Braced Frame Struvtures (2차원 가새골조의 최적내진설계를 위한 MSA 알고리즘)

  • Lee, Sang Kwan;Seong, Chang Won;Park, Hyo Seon
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.6
    • /
    • pp.629-638
    • /
    • 2000
  • With the positive features of simulated annealing algorithms such as simplicity of the algorithm and the possibility of finding global optimum solution, SA algorithm has been widely applied to structural optimization problems. However, the algorithms are far from practical applications in structural design or optimization of building structures due to requirement of a large number of iterations and dependency on cooling schedule and stopping criteria. In this paper, with the modification of annealing process and stopping criteria, a MSA algorithm is presented in the form of two phase annealing process for optimal seismic design of braced structures. The performance of the proposed algorithm has been illustrated in detail.

  • PDF

가압경수로 안전주입계통 최적화를 위한 SBLOCA 영향 고찰

  • 이남호;허재영;배규환;이상종;황순택
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.519-524
    • /
    • 1996
  • 울진 3,4호기 안전주입계통의 용량 변화가 가상적인 소형냉각재상실사고 거동에 미치는 민감도 해석을 수행하여 이를 System 80 설계발전소의 CESSAR-F 와 비교함으로써 후속호기 계통설계 및 사고해석을 위한 안전주입계통의 최적화에 활용코자 하였다. 본 논문에서 해석은 USNRC가 승인한 ABB-CE 평가 모델을 적용하여 수행하였으며, 이의 결과 소형 파단 사고시 안전주입탱크의 용량 및 고압 안전주입유량을 울진 3,4호기의 60% 까지 줄였을 때에도 경수로용 비상노심냉각계통 허용 기준$^{(1)}$ 을 만족함을 확인하였다.

  • PDF

CFD Analysis on the Effect of the Nozzle Arrays and Spray Types in the Hydrogen Peroxide Mixing Quencher to Improve the Mixing Efficiency (과산화수소 혼합냉각기 내의 노즐배치 및 가스분사 방식 변화에 따른 혼합율 개선에 대한 전산해석적 연구)

  • Koo, Seongmo;Chang, Hyuksang
    • Clean Technology
    • /
    • v.23 no.1
    • /
    • pp.42-53
    • /
    • 2017
  • Numerical analysis was done to evaluate the fluid distribution inside of the mixing quencher to increase the reaction efficiency of the aqueous hydrogen peroxide solution in the scrubbing column which is used for simultaneous desulfurization and denitrification. Effective injection of the aqueous hydrogen peroxide ($H_2O_2$) solution in the mixing quencher has major effects for improving the reaction efficiency in the scrubbing column by enhancing the mixing of the aqueous $H_2O_2$ solution with the exhaust gas. The current study is to optimize the array of nozzles and the spray angles of the aqueous $H_2O_2$ solution in the mixing quencher by using the computational method. Main concerns of the analysis are how to enhance the uniformity of the $H_2O_2$ concentration distribution in the internal flow. Numerical analysis was done to check the distribution of the internal flow in the mixing quencher in terms of RMS values of the $H_2O_2$ concentration at the end of quencher. The concentration distribution of $H_2O_2$ at the end of is evaluated with respect to the different array of the nozzle pipes and the nozzle tip angles, and we also analyzed the turbulence formation and fluid mixing in the zone. The effect of the spray angle was evaluated with respect to the mixing efficiency in different flow directions. The optimized mixing quencher had the nozzle array at location of 0.3 m from the inlet duct surface and the spray angle is $15^{\circ}$ with the co-current flow. The RMS value of the $H_2O_2$ concentration at the end of the mixing quencher was 12.4%.

가압경수로 안전주입계통 최적화를 위한 LBLOCA 영향 고찰

  • 정재훈;이상종;권태순;반창환;황순택
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.321-327
    • /
    • 1996
  • 울진 3,4호기 안전주입계통의 용량 변화가 가상적인 대형파단 냉각재상실사고 거동에 미치는 현상을 파악하여 이를 후속호기 계통설계 및 사고해석을 위한 안전주입계통의 최적화에 활용하고자 하였다. 본 논문에서 해석은 USNRC 가 승인한 ABB-CE 평가 모델을 적용하여 수행하였으며, 이의 결과 대형파단 사고시 안전주입탱크 용량을 울진 3,4호기의 60% 까지 줄였을 때에도 경수로용 비상노심냉각계통 허용기준$^{(1)}$ 을 만족하였다. 또한 저압 안전주입계통을 고려하지 않았을 경우, 안전주입탱크 용량을 울진 3,4호기의 60%, 고압 안전주입유량을 울진 3,4호기의 175%로 가정했을 때 경수로용 비상노심냉각계통 허용기준을 만족함을 확인하였다.

  • PDF

Reduction of Design Variables for Automated Optimization of Injection Mold Cooling Circuit (사출금형 냉각회로 자동최적화를 위한 설계변수 감소 방안)

  • Rhee, B.O.;Choi, J.H.;Tae, J.S.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.4
    • /
    • pp.417-422
    • /
    • 2009
  • The injection mold cooling circuit optimization was studied with a response surface method in the previous research. It took so much time to find an optimum solution for a large product due to an extensive amount of calculation time for the CAE analysis. In order to use the optimization technique in the actual design process, the calculation time should be much reduced. In this study, we tried to reduce the number of design variables with the concept of the close relationship between the depth and the distance of cooling channel. The optimum ratio of the distance to the depth of cooling channels for a 2-dimensional problem was 2.0 so that the optimum ratio was again sought out for 4 large automotive parts. Therefore, the number of design variables for the cooling circuit optimization can be reduced in half, resulting in much faster running time for the optimization as a design tool.

  • PDF