• Title/Summary/Keyword: 냉각 운전

Search Result 334, Processing Time 0.021 seconds

An Investigation on Influence of Vibration Noise in Cooling Tower on Precision Equipments (산업용 냉각탑의 진동소음이 정밀장비에 미치는 영향에 대한 연구)

  • Lee, Jin-Kab
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.369-374
    • /
    • 2016
  • Cooling towers have been installed on rooftops or outside of buildings and widely applied to control the indoor temperature in residential areas and buildings. However, the noise and vibration resulting from their operation may cause problems in adjacent buildings. The purpose of this study is to measure the noise and vibration of an industrial cooling tower located adjacent to industrial plants and to investigate its influence on the surroundings according to an authorized evaluation standard. Further, in order to measure the effect of the vibration of the tower on the precision equipment inside the plant, an experiment is conducted to measure the vibration of the ground in the plant and the targeted precision equipment. The measurement results indicate that the noise in the cooling tower is 4 to 9 dB(A) higher than the maximum level defined in the standard of 68dB(A). The effect of the vibration of the tower on the precision equipment is comparatively minimal, because that in the supporting frame of the building is weaker than that on the floor where the precision equipment is located. The vibration of the floor on.

SOPHT 코드를 이용한 열수송계통의 정지냉각 천이해석

  • 김태한;김영보;정종식;한상구
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.371-376
    • /
    • 1995
  • CANDU-6형 원자로의 정지냉각계통(Shutdown Cooling System, SDCS)은 영출력 고온상태의 원자로를 상온상태로 냉각시킬 수 있도록 설계되었다. 본 해석은 증기발생기와 복수기증기방출밸브(CSDV) 및 정지냉각펌프를 이용한 정상냉각과 열수송펌프를 이용한 26$0^{\circ}C$부터 냉각 및 정지냉각펌프를 이용한 26$0^{\circ}C$부터 냉각의 두 가지 비정상냉각에 대해서 중수로 계통설계의 열수력 해석코드인 SOPHT 코드를 사용하여 해석하였다. 해석결과에 따라 주요기기들의 냉각천이에 따른 운전부하(service loadings)조건이 주어졌으며 또한 정지냉각계통은 열수송계통과 관련 보조계통을 정지냉각계통 열교환기 2차측에서 비등이 발생하지 않고 정상냉각 허용한계인 2.8$^{\circ}C$/min를 만족하면서 냉각할 수 있음을 확인하였다.

  • PDF

Characteristics of On-off Control and Hot-Gas Bypass Control in an Industrial Cooler (산업용 냉각기의 온오프 제어와 토출가스 바이패스 제어 특성 비교)

  • Baek, Seung-Moon;Moon, Choon-Geun;Kim, Eun-Pil;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.429-435
    • /
    • 2011
  • In this study the operational characteristics of the temperature control system between an on-offemployed cooler and a bypass type cooler is analyzed. Currently an on-off controller employed coolerwhich is the industry's leading type on the market for industrial coolers is used. The new type cooler isused a bypass controller at discharge gas. The COP of the bypass controlled cooler with discharge gas is at least 8% higher than the on-off controlled cooler. The maximum COP difference is about 20%. Based on the results, the bypass control with discharge gas shows the possible temperature control with high precision.

천연가스 복합발전 플랜트의 성능예측

  • Lee, Jin-Wook;Lee, Chan;Cho, Byeong-Hwa
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.05a
    • /
    • pp.55-63
    • /
    • 1994
  • 국내에서 실제 운전되고 있는 천연가스 복합발전플랜트의 성능 예측에 대한 공정전산 해석을 수행하였다. 가스터빈 사이클은 압축기, 연소기, 터빈 및 터빈 날개의 냉각을 위한 냉각계통으로 구성하였으며, 중기터빈 사이클은 폐열회수보일러, 고압/중압/저압터빈, 펌프 및 부속공정으로 구성하였다. 해석결과는 실제 플랜트의 운전자료와 정성적 및 정량적으로 잘 일치하였으며, 폐열회수보일러의 적절한 설계에 의하여 전체 플랜트의 출력향상을 도모할 수 있음을 제시하였다.

  • PDF

A Design Study of Phase Changing Heat Exchanger for Environmental Control System (환경조절장치용 상변화열교환기의 개념설계연구)

  • Yoo, Young-June;Oh, Chang-Mook;Lee, Hyung-Joo;Min, Seong-Ki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.628-635
    • /
    • 2010
  • Properties of bleed air that is air source of ECS(Environmental Control System) can be rapidly changed with airplane engine operating conditions during flight. Therefore, ECS can be operated at a high performance or not during flight. So, high performance ACM has to be developed in order to flight safely. A adaptability of phase changing heat exchanger was esteemed at ACM type ECS in this study. As a result of this study, it is found that ECS outlet temperature can be controlled in a certain range with the phase changing phenomenon.

  • PDF

An Investigation of Transient Responses of CANDU-6 PHTS Using DSNP (DSNP Language를 이용한 CANDU-6 PHTS 과도상태)

  • 전용준;박지원;오세기;정근모
    • Journal of Energy Engineering
    • /
    • v.4 no.1
    • /
    • pp.103-114
    • /
    • 1995
  • 본 연구는 원자력발전소용 시뮬레이션 언어인 DSNP(Dynamic Simulator for Nuclear Power-plants)언어를 이용하여 CANDU-6 발전소 운전 모사 프로그램을 구성함으로써 핵심계통인 1차 냉각재 계통(PHTS)과 2차 계통 일부가 정상 및 과도조건에서 보일 수 있는 운전 상태를 연구하였다. DSNP 프로그램은 원자로심과 증기발생기에서의 열전달 모델, 열수송계통 펌프 모델 및 가압기 열수력 모델을 포함하고 있으며, 파이프(pipe)라는 단위 구성체를 이용하여 1차 냉각재계통을 노드화하여 계통 모사가 실현된다. 정상상태 100% 전출력 운전시 대표적인 운전변수를 기준으로 DSNP 결과와 CANDU-6 발전소 설계치를 비교해 본 결과 서로 매우 근사한 값을 나타내었으며, 이는 과도상태 모사의 초기조건으로 합당한 것으로 판단된다. 본 연구에서 선택된 과도상태 모사시 DSNP 프로그램은 매우 안정된 최종정상상태를 얻음에 따라 원자로의 기계 물리학적 변화를 합리적으로 모사하고 있음을 알 수 있었다. 최종 정상상태 회귀 이전의 동적 거동을 원자로 설계자료인 예비 안전성 평가 보고서(PSAR)와 비교한 결과 단기적 거동은 PSAR 결과와 다소 다른 점이 있었으나 전체적으로 합리적인 운전변수 값을 얻을 수 있었다. 단기적 거동에 대한 입증은 원자로 운전 자료를 통하여 가능할 것으로 사료된다. 이상과 같이 본 연구를 통해 구성한 DSNP 프로그램은 보완 및 개선의 여지가 있으나 현재의 수준으로도 CANDU-6 발전소의 일부 과도상태 모사가 가능한 것으로 판단된다.

  • PDF

The Cooling Water Bypass Ratio of Packing in Plume Abatement Cooling Tower of a Combined Cycle Power Plant During Winter Operation (복합화력발전소 동계운전시 백연방지 냉각탑 냉각수의 충전재 바이패스 비율 확인)

  • Chung, Hee-Bong;Yoo, Hoseon
    • Plant Journal
    • /
    • v.14 no.4
    • /
    • pp.33-38
    • /
    • 2018
  • In this study, it was confirmed whether the cooling water bypass ratio of packing for plume abatement matched designed value during winter operation of combined cycle power plant. Designed operating wet bulb temperature of the plume abatement cooling tower with 29 Gcal/h capacity had a range from $13^{\circ}C$ to $-20^{\circ}C$, while its designed bypass ratio was from 0 % to 78%, so that increasing rate of the designed bypass ratio was $2.36%/^{\circ}C$ when the external temperature decreased. When the wet bulb temperature at cooling tower inlet had a range from $7.8^{\circ}C$ to $-11.8^{\circ}C$ in a normal operation, it was measured that actual bypass ratio of packing for plume abatement had a range from 23.8 % to 74.3%. While increasing rate of the actual bypass ratio was $2.71%/^{\circ}C$ in a range from $7.8^{\circ}C$ to $-9.55^{\circ}C$, it was $1.61%/^{\circ}C$ under $-10^{\circ}C$ in cold weather condition according to atmospheric temperature drop, therefore it was confirmed that the increasing rate of the bypass ratio for packing was lowered than its design.

  • PDF

원자로 냉각재배관의 열취화 평가

  • 장윤석;조성빈;진태은;장창희;정일석;홍승열
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.489-494
    • /
    • 1997
  • 주조 스테인레스강으로 제작된 원자로 냉각재배관은 고온에서 장기간 운전됨에 따라 열취화의 영향을 받을 수 있다. 장기간의 열취화는 재료의 연성 및 파괴인성을 저하시킬 수 있으며, 배관에 균열이 존재하는 경우 건전성을 위협할 수 있다. 따라서 본 논문에서는 원전수명연장을 위한 타당성 검토 측면에서 Chopra의 방법 등을 이용한 원자로 냉각재배관의 열취화 평가 및 민감도 분석을 수행하였다. 이를 통해 원자로 냉각재배관의 열취화 수준을 정량화하였고, 건전성 평가에 활용될 수 있는 J$_{IC}$ 값을 예측하였으며, 열취화에 영향을 미치는 주요 인자를 도출하였다.

  • PDF

중수로 수화학 운전평가

  • 백승우;안도희;이한수;정홍석;손순환;정양근
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.545-549
    • /
    • 1996
  • 원자력발전소에서는 수질관리를 위하여 여러가지 화학적 매개변수들의 운전범위를 지정하여 관리하고 있다. 특히, 중수를 냉각재와 감속재로 사용하는 중수로의 경우에 일차계통에서는 pH$_{A}$, 전도도, 리튬농도를 중요한 매개변수로 활용하여 관리하고 있다. 본고에서는 중수로의 화학조절지침을 작성하는데 고려되는 매개변수들 사이의 이론적인 상관관계를 검토하고 이러한 이론적인 배경에 기초하여 월성 1호기의 운전자료를 분석한 결과, 운전변수들이 대체적으로 운전범위내에서 잘 유지되고 있음을 알 수 있었다.

  • PDF