• Title/Summary/Keyword: 냉각 소자

Search Result 173, Processing Time 0.033 seconds

Control of Heat Temperature in Light Emitting Diodes with Thermoelectric Device (열전소자를 이용한 발광다이오드의 발열 온도 제어)

  • Han, S.H.;Kim, Y.J.;Kim, J.H.;Kim, D.J.;Jung, J.Y.;Kim, S.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.4
    • /
    • pp.280-287
    • /
    • 2011
  • The heat temperature of a light emitting diode (LED) is investigated with the thermoelectric device (TED). The Peltier effect of the thermoelectric device is used to control the heat radiation and the junction temperature of high-power LEDs. For the typical specific current (350 mA) of high-power (1 W) LEDs, the LED temperature and the p-n junction temperature become $64.5^{\circ}C$ and $79.1^{\circ}C$, respectively. For 0.1~0.2 W driving power of TED, the LED temperature and the junction temperature are reduced to be $54.2^{\circ}C$ and $68.9^{\circ}C$, respectively. As the driving power of the TED increases over 0.2 W, the temperature of LED itself and the junction temperature are increased due to the heat reversed from the heat-sink to LED. As the difference of temperature between LED and the heat-sink is increased, the quantity of reversed heat becomes larger and it results to degrade the cooling capability of TED.

U-type Cross-Counter Indirect Evaporative Cooler made of Plastic/Paper (U형 직교 대향류 플라스틱/종이 재질 간접증발소자)

  • Kim, Nea-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.732-739
    • /
    • 2016
  • In Korea, the summer is hot and humid, and much electricity is consumed for air conditioning. Thus, the simultaneous usage of an indirect evaporative cooler and a common air conditioner could reduce the sensible heat and save electricity. This study developed a U-type cross-counter flow indirect evaporative cooler (IEC) made of plastic and paper. The efficiencies were compared with those of a cross-flow IEC. The specimen was $500mm{\times}500mm{\times}1000mm$. the results show that the indirect evaporation efficiencies of the cross-counter flow sample were 6-21% higher than those of the cross-flow sample. The pressure drops of the cross-counter sample were 51-66% higher. Thermal analysis based on the -NTU method predicted the experimental data within 10%. The electrical energy saved by the use of the cross-counter flow IEC was larger than that of the counter flow IEC, and the difference increases with the velocity. However, the the cross-counter IEC is two times larger than the cross-flow IEC, which may increase the material cost and water usage.

나노 기술을 이용한 열전재료 연구 동향

  • No, Jong-Uk;Gang, Chan-Yeong;Kim, U-Cheol;Lee, U-Yeong
    • Journal of the KSME
    • /
    • v.49 no.9
    • /
    • pp.35-39
    • /
    • 2009
  • 열전현상을 열을 전기로 변환하거나, 전기를 열전현상(냉각현상)으로 변환하는 것이다. 열전소자는 안정적이고, 다양한 사이즈(나노$\sim$매크로)가 가능하나, 효율이 낮다. 최근 들어 나노기술이 도입되어 효율이 획기적으로 높아졌다. 이 글에서는 나노기술을 이용한 열전 재료의 연구 동향에 관하여 살펴보고자 한다.

  • PDF

Study on the Cooling Performance of Single and Cascade Refrigeration Systems Using Thermoelectric Modules (열전소자를 이용한 싱글 및 캐스케이드 냉동시스템의 냉각 성능에 관한 연구)

  • Lim, Changhak;Kim, Dongwoo;Kim, Yongchan;Seo, Kookjeong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.12
    • /
    • pp.641-646
    • /
    • 2013
  • The purpose of this study is to improve the cooling performance of single and cascade refrigeration systems using thermoelectric modules. The system consists of a heat sink, fan, and thermoelectric module. The operating parameters considered in this study include power distribution between the first- and second-stage thermoelectric modules, air flow, and variable condensing unit. The cooling capacity increased with decreases in the temperature difference between hot and cold surfaces, but decreased with increases in the condensing temperature. The COP decreased with increasing electric power of the thermoelectric module because of the increased Joule heat. The cooling performance improvement using the thermoelectric module is represented by the freezer temperature.

A study of thermoelectric Heat Pump device (열전소자를 이용한 히트펌푸에 관한 연구)

  • 박창엽
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.5 no.1
    • /
    • pp.6-12
    • /
    • 1968
  • Experiments have been made on alloys to determine the practicability of using the Peltier effect in a thermoelectric devices. The cooling and heating results of thermoelectrie material coposed of n and p type BiTe are used, whose properties are; , , , , and K: thermal conductivity. The temperature of the cold part has been measured in veccum with respect to the temperature of the hot part. The experiment result agreed fairly with expectation such as was 42 degree C.

  • PDF

Water Cooling Pipe Optimal design for Heat-Dissipation of wind power converter system (풍력발전용 전력변환기의 방열을 위한 수냉식 배관 최적 설계)

  • Choi, Jin-Ho;Oh, Seung-Yeol;Choi, Jung-Sik;Yang, Seung-Hak;Kim, Dae-Kyong
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.485-486
    • /
    • 2011
  • 대용량 전력변환기에서 대부분의 열은 IGBT 소자에서 발생한다. 따라서 소자의 방열을 위한 방열시스템은 전력변환기의 구동 뿐 아니라 각 장치들에 대한 소형, 경량화의 추세에 있어서도 중요한 부분을 차지한다. 본 논문에서는 소자의 냉각을 위해 수냉식 방법을 선정하였으며, 배관 구조에 따른 방열판의 방열특성을 비교하여 최적의 배관 구조를 가진 수냉식 방열판을 제안하였다.

  • PDF

Iodine 도핑에 따른 $Bi_2Te_3$ 열전 성능 변화 연구

  • Kim, Gwang-Cheon;Kim, Seong-Geun;Lee, Deuk-Hui;Kim, Hyeon-Jae;Kim, Jin-Sang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.695-695
    • /
    • 2013
  • 양단간의 온도차를 이용한 열전 발전 및 펠티어 효과를 이용한 열전냉각 소자는 전기와 열의 직접적인 변환으로 활용도가 높아 차세대 에너지 연구 분야로 각광 받고 있다. 열전 소자의 성능 척도는 성능지수 Z (Figure of Merit)로 나타내며, Seebeck 계수 및 전기전도도, 열전도도의 관계로 주어지게 되고 재료의 물성치가 소자의 성능에 큰 영향을 주게 된다. 따라서, 열전재료의 성능을 높이는 연구가 활발히 진행되어 왔으며, 최근 에너지 밴드 구조를 조절하여 Seebeck계수의 향상을 시도하는 연구가 많이 진행되고 있다. 이는 페르미 레벨근처에 도핑 된 원자들이 Density of states에 추가로 준위를 형성하여 Seebeck 계수 향상을 가능하게 한다. 본 연구에서는 상온용 열전 물질인 $Bi_2Te_3$에 Iodine 도핑을 통한 열전 성능 변화를 고찰하고자 한다. $Bi_2Te_3$는 유기금속 화합물 증착 방법으로 성장하였고 기판으로 $4^{\circ}$기울어진 GaAs를 사용 하였다. 전기적 특성은 Seebeck 측정 및 Van der Pauw법에 의한 Hall measurement 방법으로 분석하였다.

  • PDF

Thermal Impedance measurement of Semiconductor Device with Thermal Pulse (Thermal pulse를 이용한 반도체 소자의 thermal impedance 측정법)

  • Seo, Kil-Soo;Kim, Ki-Hyun;Bahng, Wook;Kim, Sang-Cheul;Kim, Nam-Kyun;Kim, Eun-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1977-1979
    • /
    • 2005
  • 열저항 측정법에는 정상상태보다는 과도응답 특성을 이용하는 것이 우수한 것으로 20년부터 알려져 왔다. 온도를 시간의 함수로 나타내는 열적 계단응답함수를 이용하면 칩에서 주위 분위기, 냉각장치 또는 마운트를 포함한 열 임피던스를 측정할 수 있다. 소자 접합부의 열적 동특성을 측정함으로써 칩 주변의 기하학적 물질에 대한 특성을 파악할 수 있으며 나아가 측정으로부터 소자의 열적 구조를 유추할 수 있다. 본 논문에서는 열적 계단응답 특성을 이용한 열 임피던스 측정이론 및 원리에 대해서 개관하였다.

  • PDF

Development of SiC based 3kW high frequency·high power density LDC for electric vehicles (SiC 기반의 전기자동차용 3kW급 고주파·고밀도 LDC 개발)

  • Suk, Chaeyoung;Kim, Sangjin;Ramadhan, Ramadhan;Choi, Sewan;Yu, Byeongu;Park, Sanghun
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.257-258
    • /
    • 2020
  • 본 논문에서는 고효율·고전력밀도를 위하여 WBG소자를 적용한 3kW 전기자동차용 LDC를 제안한다. SiC소자에 250kHz의 스위칭 주파수를 적용하였으며, 65℃의 냉각수 온도를 기준으로 모든 소자가 110℃ 이하로 온도관리가 될 수 있도록 냉각기를 설계하였다. 또한 센터탭 구조와 전류 더블러 구조 플라나 변압기의 단면적 비교를 통해 전류 더블러 정류기가 토폴로지로 선정되었다. Low Profile을 위하여 통합형 커스터마이징 플라나 코어 및 PCB 레이어를 설계·제작하였고 3kW 1차시 작품으로부터 96.36%의 효율과 3.68kW/L의 전력밀도를 달성하였다.

  • PDF