• Title/Summary/Keyword: 냉각 비용

Search Result 114, Processing Time 0.024 seconds

Characteristics of the Water Pressure Drop Considering Heat Transfer in the Evaporator and Condenser of a Water Chiller (냉수공장에서 열전달을 고려한 응축기와 증발기의 물 압력강하 특성)

  • Nguyen, Minh Phu;Lee, Geun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1293-1300
    • /
    • 2011
  • The configurations of the evaporator and condenser of a water chiller can be determined from the trade-off between the heat transfer area, which is related to the capital cost and the pressure drop, which is associated with the operational cost. In this study, the design of the water chiller focused on minimizing the water pressure drop of both condenser and evaporator for given cooling capacity and requirements. Commercial enhanced tubes were employed to simulate real-life conditions. The results of the present analysis were compared with those obtained by HTRI software for verifying them. The results indicated that a reduction in the water pressure drop, which is associated with the short length of a tube, can be effected by decreasing the number of tube passes and increasing the number of tubes and the tube diameter. However, using a large number of tubes with smaller diameters can reduce the capital cost because the tubes are short. The reduction of the capital cost is due to the fact that a small-diameter tube has low internal thermal resistance and hence contributes to a decrease in the overall thermal resistance per unit length.

Cooling Architecture Research of Rack Units for the IDC Power Efficiency (전산실 전력효율화를 위한 랙 단위 냉각 아키텍처 연구)

  • Tae, Hyo-Sik;Park, Koo-Rack;Kim, Dong-Hyun
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2015.07a
    • /
    • pp.183-184
    • /
    • 2015
  • 본 논문에서는 데이터 센터 내 전력 효율화에 기여할 수 있는 랙 단위 공조방식에 대하여 제안한다. 스마트 폰과 태블릿 등 모바일 디바이스의 확산으로 디지털 콘텐츠와 데이터가 폭발적으로 증가하면서 데이터 센터의 수는 연평균 30%이상 증가하고 있다. 따라서 데이터 센터 내 냉방장비 영역의 효율성을 증가시킬 필요성이 대두되고 있다. 본 연구는 데이터 센터의 냉각비용을 증가시키는 전력 사용량을 줄이고자 진행되었으며 3종류의 냉각 아키텍처 방식 중 랙 단위 아키텍처가 불필요한 냉각 전력 소비를 줄인다는 것을 확인하였다.

  • PDF

신뢰도 분석 방법을 이용한 사용후핵연료 중간저장시설 냉각계통의 최적설계에 관한 연구

  • 고원일;최종원;박성원;박현수
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.596-601
    • /
    • 1995
  • 신뢰도 분석 방법을 이용하여 습식 사용후핵연료 중간저장시설의 냉각계통에 대한 최적 설계조건을 도출하기 위한 연구를 수행하였다. 먼저 고장수목 분석을 통한 설계 취약점을 평가하여 21개의 설계대안을 도출하였고, 최종적으로 설계대안에 대한 건설비 용, 계통신뢰도 분석 및 확률론적 안전기준을 고려한 비용효과 분석을 실시하였다. 설계 대안들 중에서 100% 루프 다중설계, 루프당 한 개의 펌프 사용, 안전등급 부여 및 주 루프에서 정화계통이 분리된 경우가 최적설계안으로 나타났다. 여기서 적용된 방법론은 유사시설의 최적설계에 유용하게 응용될 수 있을 것으로 사료된다.

  • PDF

Field Investigation and Analysis of Greenhouse with Evaporative Cooling Systems (증발냉각시스템 설치온실의 실태 조사 및 분석)

  • 김기성;김문기;유인호;원종선
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1999.11a
    • /
    • pp.213-216
    • /
    • 1999
  • 우리나라의 기후 특성상 여름철에는 온실내 기온과 지온이 과다하게 상승하여 정상적인 작물 생육을 기대하기 어렵다. 이러한 고온현상을 극복하기 위해 우리나라 시설원예 농가에서는 소극적이면서 비용이 적게 드는 흑색 차광망이나 자연환기를 주로 이용하고 있으며 냉방 효과가 적어 문제가 되고 있다. 근래 온실 냉방에 대한 중요성을 인식하고 증발냉각시스템을 도입하는 시설원예농가가 증가하고 있으나 기술적인 측면에서 아직 많은 문제점들이 남아있는 실정이다. (중략)

  • PDF

Analysis on the Cooling Efficiency of High-Performance Multicore Processors according to Cooling Methods (기계식 쿨링 기법에 따른 고성능 멀티코어 프로세서의 냉각 효율성 분석)

  • Kang, Seung-Gu;Choi, Hong-Jun;Ahn, Jin-Woo;Park, Jae-Hyung;Kim, Jong-Myon;Kim, Cheol-Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.7
    • /
    • pp.1-11
    • /
    • 2011
  • Many researchers have studied on the methods to improve the processor performance. However, high integrated semiconductor technology for improving the processor performance causes many problems such as battery life, high power density, hotspot, etc. Especially, as hotspot has critical impact on the reliability of chip, thermal problems should be considered together with performance and power consumption when designing high-performance processors. To alleviate the thermal problems of processors, there have been various researches. In the past, mechanical cooling methods have been used to control the temperature of processors. However, up-to-date microprocessors causes severe thermal problems, resulting in increased cooling cost. Therefore, recent studies have focused on architecture-level thermal-aware design techniques than mechanical cooling methods. Even though architecture-level thermal-aware design techniques are efficient for reducing the temperature of processors, they cause performance degradation inevitably. Therefore, if the mechanical cooling methods can manage the thermal problems of processors efficiently, the performance can be improved by reducing the performance degradation due to architecture-level thermal-aware design techniques such as dynamic thermal management. In this paper, we analyze the cooling efficiency of high-performance multicore processors according to mechanical cooling methods. According to our experiments using air cooler and liquid cooler, the liquid cooler consumes more power than the air cooler whereas it reduces the temperature more efficiently. Especially, the cost for reducing $1^{\circ}C$ is varied by the environments. Therefore, if the mechanical cooling methods can be used appropriately, the temperature of high-performance processors can be managed more efficiently.

Prediction of Cooling Performance for Indirect Evaporative Cooling System Using Danpla Sheet (단프라시트를 적용한 간접식 증발냉각 장치의 냉각 성능 예측)

  • Kim, Myung-Ho;Kim, Byoung Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.892-897
    • /
    • 2020
  • Previous plastic heat exchangers are expensive because the mold must be newly manufactured depending on the air conditioning space. On the other hand, danpla is so thin that the heat exchange performance is excellent. Moreover, danpla can be used easily in ventilation systems in view of fabrication. This study proposes correlations for the cooling performance of an indirect evaporative cooling system. The experimental apparatus consisted of a heat exchanger, spray nozzle, fan, thermostat, pump, and measuring sensors for temperature, humidity, and airflow rate. The results showed that the effectiveness decreased gradually as the airflow rate increased. In addition, there was an optimal condition in terms of effectiveness. The performance prediction correlations were determined using the experimental data from various conditions. The proposed correlations showed performance accuracies within 4 % error.

Effect of Greenhouse Cooling Method on the Growth and Yield of the Tomato cv. Momotaro in Warm Season (고온기 유리온실의 냉방방법이 토마토 생육 및 수량에 미치는 영향)

  • 최영하;이재한;박동금;권준국;엄영철
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1999.11a
    • /
    • pp.164-168
    • /
    • 1999
  • 온실은 동절기 난방을 주목적으로 설비되어 년중 작물재배 시는 하절기 온실내부 온도가 필요이상으로 상승하여 실내온도가 35-4$0^{\circ}C$ 정도로 올라가는데 이러한 상태에서의 온도는 많은 작물의 생육적온을 벗어난 온도로서 고온장해를 나타낸다. 이 같은 문제점을 해결하기 위해 몇 가지 냉방방법이 알려져 있는데 에어컨 등과 같은 냉방장치를 이용한 기계적 냉각방식과 수분증발을 통한 증발식 냉각방식으로 대별되며 이중 기계적인 냉방방식은 설비나 유지관리 면에서 비용이 많이 들어 비경제적이고, 증발냉각 방식중에서도 Fan and Pad 법이 가장 효과가 좋은 것으로 알려져 있으나 이역시 설치 및 유지비가 많이 들고, vep의 탈부착이 어려워 고정시켜놓을 경우 동계 광투과에 방해가 되는 등의 문제가 많다. (중략)

  • PDF

Study on the Rapid Manufacturing for Investment Casting (쾌속조형기를 이용한 정밀주조물의 쾌속제작에 관한 연구)

  • 주영철;김태완
    • Proceedings of the KAIS Fall Conference
    • /
    • 2002.05a
    • /
    • pp.49-51
    • /
    • 2002
  • 산업 현장에서 많이 사용되는 정밀주조법은 왁스형 제작 공정이 수작업으로 이루어지기 때문에 시간과 비용이 많이 소요된다. 이를 쾌속조형기를 이용하여 신속하고 정밀하게 왁스형을 제작하는 공정을 개발하였다. 먼저 3D CAD 데이터를 SLS형 쾌속조형기에서 캐스트폼 분말을 사용하여 캐스트폼형을 만든다. 오븐에서 왁스를 용융시키고 여기에 캐스트폼형을 넣어서 왁스가 캐스트폼형의 공극에 함침되도록 한다. 천천히 냉각시킨 후 꺼내면 왁스형이 완성되며 이를 일반적인 정밀주조공점을 거치면 최종 금속 주물이 완성된다. 이 신공정을 이용함으로서 제작시간과 비용이 크게 단축되었으며 제품의 정밀도가 향상되었다.

Development of a computer program for refrigeration load calculation in a cold storage house (저온저장고 냉각부하분석 프로그램 개발)

  • Jeong, H.;Yun, H.S.;Lee, W.O.;Lee, H.D.;Cho, K.H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.07a
    • /
    • pp.238-246
    • /
    • 2003
  • 우리나라 농산물 저온저장고 설치비 중 70% 이상이 저장고내 열관리를 위한 자재와 설비에 소요되며, 저온저장고의 가동에는 많은 에너지가 소요되므로 열관리 설비 및 에너지 비용의 최소화로 저온저장 비용을 절감화 시킬 필요가 있다. 더욱이, 우리나라는 에너지의 대부분을 수입에 크게 의존하는 나라로 에너지를 효율적으로 관리하는 것이 매우 중요하다. (중략)

  • PDF

A Study on Measurement and Elimination Methods of Dissolved Nitrogen in Kerosene (케로신 내 용존질소 측정 및 제거 방법 연구)

  • Lee, Wongu;Kim, Seong Lyong;Ahn, Kyubok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.142-148
    • /
    • 2018
  • To improve the performance of a launch vehicle, kerosene, a launch vehicle fuel, undergoes a densification process. Liquid nitrogen injection cooling is an effective densification method which has a simple system and is inexpensive. During the cooling process, however, nitrogen may dissolve in the kerosene, possibly resulting in changes to fuel properties. Therefore, it is essential to measure and eliminate the amount of dissolved nitrogen in the kerosene. In this study, the vacuum extraction principle is introduced to measure the content of dissolved nitrogen in the kerosene. In addition, the experimental results, which used a designed/manufactured nitrogen sampling device, are described. From the results, the validity of the nitrogen sampling device and the dissolved nitrogen measurement/elimination methods was demonstrated.