• Title/Summary/Keyword: 냉각효과

Search Result 718, Processing Time 0.045 seconds

Analysis of the Cooling Effects in Urban Green Areas using the Landsat 8 Satellite Data (Landsat 8 위성자료를 이용한 도심녹지 냉각효과 분석)

  • Kim, Geun-Hoi;Lee, Young-Gon;Kim, Jae Hwan;Choi, Hee-Wook;Kim, Baek-Jo
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.2_1
    • /
    • pp.167-178
    • /
    • 2018
  • Urban green areas or forest regions play an important role in lowering the air temperature of the surrounding areas. This cooling effect does not only affect inside of the green areas, but also extends into neighboring streets and buildings. In this study, the Land Surface Temperature (LST) are retrieved from the Landsat 8 satellite data for 8 clear days in Seoul, Korea from 2013 to 2015, and used for analyzing the cooling effect at an urban green region, Seonjeongneung, located in the southern part of Seoul. The LST distribution from the boundary of the Seonjeongneung presents that the cooling effect of the green areas was found to extend in many directions into the urban areas. The LST estimations of residential and commercial areas around the Seonjeongneung are also analyzed to assess how the green areas affect the type of land cover and the surroundings in the urban areas. Relatively lower LST for the residential areas from the Seonjeongneung boundary ranges from 100 to 250 m, resulting in an average cooling effect of $2.3^{\circ}C$. On the other hand, the LST distribution in the commercial areas shows that the effective distance of green areas are relatively low in the range of 0 to 200 m, which means the average cooling effect is approximately $0.3^{\circ}C$. This result shows that the cooling effect of the Seonjeongneung is clearly noticeable, particularly, the residential areas show greater cooling effect than commercial areas.

Cooling Performance of PC cooling Fan For Various Cooling Fan Blade numbers and Design Shapes (PC용 냉각팬의 형상 및 블레이드의 수 변화에 따른 냉각성능)

  • Park, Won-Keol;Lee, Dong-Ryul
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.685-689
    • /
    • 2012
  • 본 연구는 PC용 냉각팬의 효율적인 설계를 위하여 냉각팬의 형상 변경 및 블레이드의 수 변화를 통해서 PC 부품 발열체의 온도변화를 수치해석적으로 수행하였다. 기존의 냉각팬 형상을 기준으로 블레이드의 수를 변화시키고 실제 형상을 변경한 냉각팬을 동일한 설계 입력조건를 적용하여 비교 분석하여 냉각성능을 파악하였다. 두 Case를 비교한 결과 기존 형상은 블레이드의 수가 증가 할수록 냉각효과가 커졌고, 형상을 변경한 냉각팬의 경우 Blade 6에서 가장 큰 냉각 효과를 보였다. 그리고 Blade 6과 8을 비교해 봤을 때 두 블레이드 사이에서 온도차이는 미소한차이로 냉각효과를 비교하기 어려웠다. 두 Case에서 제작과정과 비용을 비교해 보았을 때 Case 2의 Blade 6 경우가 더 우수한 것으로 보아 형상을 변경한 블레이드에서 최적설계를 얻을 수가 있었다.

  • PDF

연소실 냉각을 위한 충돌제트/유출냉각기법에서의 열전달특성

  • 이동호;조형희
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1999.04a
    • /
    • pp.7-7
    • /
    • 1999
  • 충돌/유출냉각은 연소실 벽면 등과 같이 열부하가 많이 걸리는 영역에서 고온의 연소가스로부터 표면을 보호하는 막냉각과 더불어 내부에 다공성 판을 설치하여 충돌제트에 의해 내부표면을 냉각시켜 가스터빈엔진의 고온요소의 냉각성능을 극대화시키는 방법 중의 하나이다. 이와 같은 냉각방법을 적용하면 벽면을 충돌제트에 의한 냉각과 함께 냉각유채를 막냉각에 활용함으로써 냉각효율을 극대화할 수 있다. 본 연구에서는 국소적인 값들을 획득하기 용이한 물질전달실험방법의 하나인 나프탈렌 승화법을 이용하여 수직으로 분사되는 충돌제트에 의한 유출판 내면에서의 열/물질전달특성을 분사판(injection plate)과 유출판(effusion plate) 사이의 높이, 분사제트의 속도, 분사홀간의 배열을 변화시켜가며 유출판만이 있는 경우와 비교, 분석하였다. 분사홀과 유출홀의 관 사이의 간격은 0.33d에서 10d까지 변화시켜가며 그 효과를 관찰하였으며, 홀배열 효과를 보기 위하여 2가지 홀배열(staggered array, shifted array)에 대하여 실험하였다. 또한 분사제트의 속도효과를 고찰하기 위하여 분사제트의 Rc$_{d}$=5,000-12,000까지 변화시켜가며 실험을 수행하였다.

  • PDF

전동기의 열화진단과 고장 대책②

  • 류홍우
    • Electric Engineers Magazine
    • /
    • v.193 no.9
    • /
    • pp.22-31
    • /
    • 1998
  • 전동기의 온도는 시동시 일시적으로 높게 되지만 시동이 끝나고 정격 토오크에 도달하면 냉각효과도 나타나기 때문에 온도가 떨어져 운전온도로 된다. 운전을 끝내고 정지할 때 온도는 내려가지만 정지시의 냉각효과는 적기 때문에 온도는 느리게 떨어진다.

  • PDF

Variation of Green Space Cooling Effect Influenced by Its Composition and Surroundings in Suwon City (수원시 녹지 조성 및 주변 환경에 따른 녹지 냉각 효과의 변화)

  • Seung Yeon Lee;Seong Woo Jeon
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.3
    • /
    • pp.176-186
    • /
    • 2023
  • Urban Heat Island (UHI) is caused by an energy imbalance in urban areas, where building design and land cover contribute to its amplification. To mitigate UHI, increasing green space is one of the well known and the most effective approach. This study aims aimed to identify specific components of green spaces that lower temperatures and demonstrate the cooling effects based on their size and composition. Forests within green spaces have had a greater impact on temperature reduction due to shading and blocking solar radiation. Although lakes also contributed to temperature reduction, the effect to cooling intensity was not significant. The cooling distance does not depended on green space size or composition. The study emphasizes that initial temperature has a strongerinfluence on cooling intensity than green space size, highlighting the importance of vegetation type within green spaces to achieve a cooling effect. These findings provide valuable insights for urban planning and the design of green spaces to mitigate the effects of the urban heat island.

An Examination on Cooling Effects According to Water Spray, Top and Side Windows, and Operation of Pan of Single Span Plastic Greenhouses (Part 2) (단동 플라스틱 하우스의 관수, 천.측창 개폐 및 환기팬 조작에 따른 냉각효과 검토 (제2편))

  • 최동호;허종철;임종환;서효덕
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1999.11a
    • /
    • pp.55-58
    • /
    • 1999
  • 1. 스프링클러에 의해 하우스내를 관수한 경우, 하우스내 온도는 스프링클러 작동과 동시에 급격히 하강한 후 시간이 흐름에 따라 완만한 하향구배를 나타내었다. 2. 천 측창을 개방한 상태에서 스프링클러에 의한 냉각효과를 측정한 결과, 실내기준온도는 외기온 보다 약 2.8$^{\circ}C$ 낮은 온도를 나타내었다. 3. 본 실험결과 스프링클러 관수에 의한 냉각효과는 탁월한 것으로 조사되었으며, 관수시간대를 비교적 실온이 상승하는 주간시간대로 설정한다면, 그 효과를 극대화 할 수 있을 것으로 사료된다. 이 경우, 관수시의 수량 및 관수 지속시간 등에 대해서는 재배작물의 습해 등을 고려하여 이에 대한 면밀한 검토가 이루어져야 할 것으로 판단된다.

  • PDF

Observation of the Cirrus Cloud Optical Porperties using a Multi-wavelength Lidar System (K-JIST 다파장라이다 시스템을 이용한 상층운의 광학적 특성 관측)

  • 노영민;최성철;김영준
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.283-284
    • /
    • 2003
  • Cirrus cloud는 항상 지구대기의 20%정도를 덮고 있으며, 지구 복사수지와 기후변화에 영향을 미치며 그들의 미세물리학적이고 광학적인 특성에 따라 대기온도의 상승이나 냉각효과를 나타낸다. 일반적으로 적도지방에서는 가열효과를 지니고 중위도지방에서는 냉각효과를 지닌다(F.Nicolas et al, 1997). 이러한 중요성으로 외국에서는 Cirrus cloud에 대한 많은 연구(K. Sassen et al, 2001, C. M. R. Platt et al, 1998)가 이루어졌으나 국내에서는 관측 대상의 시간적ㆍ공간적 제약으로 연구가 거의 이루어지지 않고 있다. (중략)

  • PDF

PSA 기법을 이용한 가압경수로 부분충수운전 안전성 향상방안

  • 박진희;이윤환
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.604-609
    • /
    • 1996
  • 원자력 발전소 부분 충수운전 중에 발생할 수 있는 정지냉각기능 상실사고인 과배수 사건에 대한 확률론적 안전성 평가를 수행하였다. 본 분석의 주된 목적은 과배수로 인한 정지냉각기능 상실사건에 대하여 노심손상 빈도를 계산하고 안전성 향상방안을 도출하는데 있다. 과배수 사건은 초기 부분 충수운전중 발생하는 것으로 가정하였으며 이 때의 발전소 배열(Plant Configuration)은 영광 3,4호기의 운전절차서 및 발전소 운전경험을 근거로 결정하여. 현재 운전상태에 대한 확률론적 안전성평가를 수행하였다. 분석결과 인간오류가 노심손상빈도에 가장크게 기여하는 인자로 나타났으며 인간오류를 줄 일수 있는 대체냉각 절차를 선정하여 재분석을 수행하였다. 고려된 대체냉각 수단은 피동적인 잔열제거 방법인 열규응축냉각(Reflux Cooling)과 정지냉각펌프의 대체계통으로 격납용기 살수펌프를 사용하는 경우의 두가지이다. 본 분석에서는 두가지 대체냉각수단을 모두 채택하는 것으로 가정하여 대체냉각 사용에 따른 효과를 비교하였는데 노심손상 빈도가 1/1000로 감소 하였다. 따라서 절차서 개정에 의한 대체 냉각수단확보는 부분 충수운전중 발전소 안전성 향상에 매우 효과가 큰 것으로 나타났다.

  • PDF

Cooling Characteristics and Shielding Effectiveness of hybrid IC (하이브리드 IC의 냉각특성 및 전자차 차폐효과 연구)

  • 김성철
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.2 no.2
    • /
    • pp.49-56
    • /
    • 1995
  • ATM 교환기에 사용되는 하이브리드 IC에 대해 냉각성능과 전자파 차폐성능을 실 험과 수치해석에 의해 분석하였다. 하이브리드 IC 상부에 전자파 차폐를 위해 부착하는 덮 게의 형상에 따라 냉각공기 유속 0.5~0.4m/sec 조건에서 냉각실험을 하였고 냉각 해석 코 드인 Flotherm으로 컴퓨터 시뮬레이션하여 비교하였다. 그리고 각 덮게의 형상에 따라 30MHz ~1GHz 대혁에 걸쳐 전자파 차폐 실험을 하엿다. 실험결과 냉각 특성의 실험과 수 치해석 결과 잘 일치하였으며 공기 유속을 1.0m/sec 이상으로 유지시키면 덮개 형상에 무관 하게 열적으로 안저하였다. 30~700MHz 영역에서는 덮게로 인한 전자파 차폐효과가 뚜렷하 였으나 700MHz 이후의 대역에서는 접지와 접속되는 리이드의 임피던스 증가로 인하여 차 폐효과가 감소하였다.

Numerical Study for Configuration Design in the Exhaust Gas Cooling System (배출가스 냉각장치 형상설계를 위한 수치해석)

  • Lee, Suk Young
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.7-12
    • /
    • 2016
  • This paper deals with a parametric study on cooling channel configurations to enhance the cooling effect. As a cooling effect has been increased, the exhaust gas by the plant from a manufacture is becoming deceased. To solve this problem, the design of a efficient cooling system is needed. In this paper, the cooling channel was analyzed to improve the cooling performance. The heat transfer rates depending on the number of baffle and the heiht of fin were obtained by using numerical simulation method. Three-dimensional Reynolds-averaged Naiver-Stokes equations were used to estimate flow and heat transfer in cooling channel, and the $k-{\varepsilon}$ model for turbulence closure was employed.