• Title/Summary/Keyword: 냉각재 온도

Search Result 200, Processing Time 0.023 seconds

Preparation of Folic Acid-loaded WPI (Whey Protein Isolate) Nanoparticles by Cold-induced Gelation (냉각유도젤화에 의한 엽산 함유 분리유청단백 나노담체의 제조)

  • Kim, Bum-Keun;Lee, Won-Jae;Oh, Se-Jong;Kim, Jin-Man;Park, Dong-June
    • Food Science of Animal Resources
    • /
    • v.30 no.1
    • /
    • pp.95-101
    • /
    • 2010
  • Folate loaded WPI (whey protein isolate) nanoparticles were prepared using the cold-induced gelation process. The aim of this work was to investigate the effects of process parameters, such as the concentration of the WPI solution, pH, temperature, etc, on the properties of nanoparticles. The results show that the smallest nanoparticles were obtained when a WPI concentration of 1% was used at a pH of 8.0 (<330 nm). In the case of the concentration of $CaCO_3$, the smallest particles were obtained at a concentration of 5 mM. Alginate produced the smallest mean size with the narrowest particle size distribution, while the largest particles were prepared with k-carrageenan. As the w:o ratio increased, the mean particle size also increased. When the release profile was analyzed, the particles were shown to be stable for more than 6 h at a pH of 1.2, where almost all of the folic acid was released within 2 h in the dissolution media of PBS at a pH of 7.4. Thus, the process parameters appear to be important factors that affect the properties of nanoparticles.

Separation of Ferrous Materials from Municipal Solid waste Incineration Bottom Ash (생활폐기물(生活廢棄物) 소각(燒却) 바닥재의 자력선별(磁力選別)에 따른 ferrous material의 분리(分離) 특성(特性))

  • Um, Nam-Il;Han, Gi-Chun;You, Kwang-Suk;Cho, Hee-Chan;Ahn, Ji-Whan
    • Resources Recycling
    • /
    • v.16 no.3 s.77
    • /
    • pp.19-26
    • /
    • 2007
  • The bottom ash of municipal solid waste incineration generated during incineration of municipal solid waste in metropolitan area consists of ceramics, glasses, ferrous materials, combustible materials and food waste and so on. Although the ferrous material was separated by the magnetic separation before the incineration process, of which content accounts for about $3{\sim}11%$ in bottom ash. The formation of a $Fe_3O_4-Fe_2O_3$ double layer(similar to pure Fe) on the iron surface was found during air-annealing in the incinerator at $1000^{\circ}C$. A strong thermal shock, such as that takes place during water-cooling of bottom ash, leads to the breakdown of this oxidation layer, facilitating the degradation of ferrous metals and the formation of corrosion products and it existed as $Fe_2O_3,\;Fe_3O_4\;and\;FeS_2$. So, many problems could occur in the use of bottom ash as an aggregate substitutes in construction field. Therefore, in this study, the separation of ferrous materials from municipal solid waste incineration bottom ash was investigated. In the result, the ferrous product(such as $Fe_2O_3,\;Fe_3O_4,\;FeS_2$ and iron) by magnetic separator at 3800 gauss per total bottom ash(w/w.%) accounted for about 18.7%, and 87.7% of the ferrous product was in the size over 1.18 mm. Also the iron per total bottom ash accounted for about 3.8% and the majority of it was in the size over 1.18 mm.

Research on Heat-Sink of 40Watt LED Lighting using Peltier Module (펠티어 소자를 이용한 40[W]급 LED 조명기구의 방열에 관한 연구)

  • Eo, Ik-Soo;Yang, Hae-Sool;Choi, Se-Ill;HwangBo, Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.4
    • /
    • pp.733-737
    • /
    • 2007
  • The object of this paper is to propose a method to solve resulting heat in using numerous modulized watt-class LEDs in MCPCB as lighting device. To use LED for lighting, the chip needs to have a large capacity, resulting in extra heat in P-N connection area. To solve this problem, a Pottier Module, heat-sink panel and a fan was installed to measure variations in the temperature. Additionally, temperature variation characteristics were observed according to the heat conductor panel connecting cooling module and heat-sink panel, insulator and thermal grease. As a result, the type and amount of heat-sink panel was the most important facto. The fan would effect the temperature by max. $18[^{\circ}C]$ while other materials affected the temperature by $2{\sim}3[^{\circ}C]$, showing significant difference.

  • PDF

Development of Automatic System to Measure Transmitted Ultrasonic Speed of Raw Ginseng (수삼의 초음파 전달속도 계측 자동화 시스템 개발)

  • 서동현;김기대;강호양;김찬수;이현동
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.592-599
    • /
    • 2002
  • 본 연구에서는 수삼의 가공전 선별을 위해 현장에서 편리하게 사용할 수 있는 초음파 전달 속도 계측 자동화 시스템을 개발하여 그 성능을 평가하고자 하였으며 결과를 요약하면 다음과 같다. 1. 개발된 시스템은 제어용 컴퓨터, 시스템 구동 및 탐촉자 이동 장치, 하중 변환장치, 초음파 발생 및 송수신 장치 등으로 구성되었다. 2. 제어 및 계측용 프로그램은 압축력, 측정 대상물의 크기, 초음파 전달 시간을 순차적으로 계측하여 초음파 전달 속도를 계산하는 알고리즘을 개발하였으며, Visual Basic 6.0으로 작성되었다. 모터의 작동, A/D 변환, RS232C 통신 등과 관련된 부분은 각각의 모듈화된 함수로서 구동하고자 하였다. 3. 개발된 시스템의 속도와 거리별 이동 거리별 오차를 측정한 결과 0∼0.04mm 범위를 나타내었다. 이 값은 시스템의 허용오차인 0.17mm 오차보다는 현저히 작은 값이었고 15mm/s와 30mm/s의 이동 속도에서 모두 비슷한 크기의 오차값을 나타내었다. 4. 개발된 시스템의 속도별 반복정밀도 실험 결과 측정위치에서의 반복에 의한 정지 위치 오차는 전 구간에서 0.02mm 이내로 나타났고, 이동 평판의 이동속도가 15mm/s였을 경우에는 이동 회수 30회, 이동 거리 60mm일 때 최대 편차 0.019mm를 나타냈으며 이동속도가 30mm/s일 경우에는 이동 회수 40회, 이동거리 20mm에서 0.02mm의 최대 편차를 나타내었다. 5. 5개의 알루미늄 조각의 크기를 시스템으로 측정한 결과 측정값의 최대 편차는 0.08mm였다. 이 값은 시스템의 허용오차인 0.17mm의 50% 수준으로 시스템은 대상물의 크기 측정에 적당하다고 사료되었다. 6. 절단된 수삼의 초음파 전달속도는 평균 396.4m/s였다.를 축열재로 사용할 경우 재생기를 반으로 나누어서 가열부 쪽에 철선을, 냉각부 쪽에 철망을 삽입한 것이 반대로 삽입한 것보다 재생기 양단의 온도차는 높게 나타났고, 재생기 양단의 압력 차는 낮게 나타났다. 재생기 축열재로서 철망-철선을 사용할 경우 철선-철망 ø1.2-150이 전열 표면적은 작으나 재생기 양단의 온도차가 가장 큰 것으로 나타났으며 재생기 양단의 압력 차는 가장 낮게 나타나 공시 철망- 철선 혼합 축열재중 가장 우수함을 알 수 있다. 4. 철망사이에 철선을 삽입한 축열재의 경우, 철망사이에 삽입한 철선의 직경이 큰 것이 철선의 직경이 작은 것보다 재생기의 양단의 온도차가 높게 나타났고 재생기 양단의 압력차는 작게 나타났다. 그러므로 철망사이에 철선을 삽입한 것 중 성능이 우수한 것은 150-ø2. 0-150으로 나타났다. 5. 실험한 재생기 축열재들 중에서 성능이 우수한 것들을 비교한 결과, 복합 철선 ø1.2-1 50이 가장 성능이 좋은 것으로 나타났다.적외선.열풍 복합건조방법이 높게 나타나 이것은 곡물 표면에 원적외선 방사에의한 복사열이 전달되어 열장해를 받았기 때문으로 판단되며, 금후 더 연구하여 적정 열풍온도 및 방사체 크기를 구명해야 할 것이다.으로 보여진다 따라서 옻나무 유래 F는 포유동물의 생식기능에 중요하게 작용하는 것으로 사료된다.된다.정량 분석한 결과이다. 시편의 조성은 33.6 at% U, 66.4 at% O의 결과를 얻었다. 산화물 핵연료의 표면 관찰 및 정량 분석 시험시 시편 표면을 전도성 물질로 증착시키지 않고, Silver Paint 에 시편을 접착하는 방법으로도 만족한 시험 결과를 얻을 수 있었다.째, 회복기 중에 일어나는 입자들의 유입은 자기폭풍의 지속시간을 연장시키는 경향을 보이며 큰 자기폭풍일수

  • PDF

Forced Flow Dryout Heat Flux in a Stratified Debris Bed (성층 데브리층에서의 강제대류 드라이아웃 열유속)

  • Cha, Jong-Hee;Chung, Moon-Ki;Jin, Yong-Suk
    • Nuclear Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.112-119
    • /
    • 1988
  • The purpose of this work is to obtain the experimental data for the forced How dryout heat flux in a heat generating stratified debris bed which simulates the degraded nuclear reactor core after severe accident. The present observations were mainly focused on the effect of coolant mass flux on the dryout heat flux in the stratified debris bed which consists of several layers with selected particle sizes under constant bed depth and temperature of inlet coolant flow conditions. The following results were obtained from this experimental work: (1) The dryout heat flux in the stratified debris bed increases with increase of upward forcing mass flux of coolant. The similar trend of increase rate of dryout heat flux in the stratified bed was observed in the uniform particle size bed. (2) For the comparison of theoretical values and experimental data, the use of surface area mean diameter as a particle diameter was suitable for the calculation of dryout heat flux.

  • PDF

Investigation of Hydraulic Flow Properties around the Mouths of Deep Intake and Discharge Structures at Nuclear Power Plant by Numerical Model (수치모의를 통한 원자력 발전소 심층 취·배수 구조물 유·출입구 주변에서의 수리학적 흐름특성 고찰)

  • Lee, Sang Hwa;Yi, Sung Myeon;Park, Byong Jun;Lee, Han Seung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2A
    • /
    • pp.123-130
    • /
    • 2012
  • A cooling system is indispensable for the fossil and nuclear power plants which produce electricity by rotating the turbines with hot steam. A cycle of the typical cooling system includes pumping of seawater at the intake pump house, exchange of heat at the condenser, and discharge of hot water to the sea. The cooling type of the nuclear power plants in Korea recently evolves from the conventional surface intake/discharge systems to the submerged intake/discharge systems that minimize effectively an intake temperature rise of the existing plants and that are beneficial to the marine environment by reducing the high temperature region with an intensive dilution due to a high velocity jet and density differential at the mixing zone. It is highly anticipated that the future nuclear power plants in Korea will accommodate the submerged cooling system in credit of supplying the lower temperature water in the summer season. This study investigates the approach flow patterns at the velocity caps and discharge flow patterns from diffusers using the 3-D computational fluid dynamics code of $FLOW-3D^{(R)}$. The approach flow test has been conducted at the velocity caps with and without a cap. The discharge flow from the diffuser was simulated for the single-port diffuser and multi-ports diffuser. The flow characteristics to the velocity cap with a cap demonstrate that fish entrainment can significantly be minimized on account of the low vertical flow component around the cap. The flow pattern around the diffuser is well agreed with the schematic diagram by Jirka and Harleman.

Improvement of Insulation System for LNG Storage Tank Base Slab (LNG 저장탱크 바닥판 단열 시스템 개선)

  • Lee, Yong-Jin;Lho, Byeong-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.141-147
    • /
    • 2010
  • Liquefied natural gas(LNG) is natural gas that has been converted temporarily to liquid form for ease of storage and transport it. Natural gas is the worlds cleanest burning fossil fuel and it has emerged as the environmentally preferred fuel of choice. In Korea, the demand of this has been increased since the first import from the Indonesia in 1986. LNG takes up about 1/600th the volume of natural gas in the gaseous state by cooling it to approximately $-162^{\circ}C(-260^{\circ}F)$. The reduction in volume therefore makes it much more cost efficient to transport and store it. Modern LNG storage tanks are typically the full containment type, which is a double-wall construction with reinforced concrete outer wall and a high-nickel steel inner tank, with extremely efficient insulation between the walls. The insulation will be installed to LNG outer tank for the isolation of cryogenic temperature. The insulation will be installed in the base slab, wall and at the roof. According to the insulation's arrangement, the different aspects of temperature transmission is shown around the outer tank. As the result of the thermal & stress analysis, by the installing cellular glass underneath the perlite concrete, the temperature difference is greatly reduced between the ambient temperature and inside of concrete wall, also reducing section force according to temperature load.

Structural determination of Fe-Zr-B-Ag Soft Magnetic Thin Films (Fe-Zr-B-Ag 연자성 박막의 제조 및 구조분석)

  • Min, B.K.;Lee, W.J.;Song, J.S.;Heo, J.S.;Kim, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1806-1808
    • /
    • 2000
  • MHz영역에서 사용 가능한 Fe계 연자성 재료를 초미세 결정립으로 제조하기 위해 $Fe_{93}Zr_{3}B_4$ 박막을 기본조성으로 하여 Fe와 비고용이며 약반자성인 Ag 원소를 0, 3, 4, 5, 6, 10 at.% 첨가시킨 $Fe_{93-x}Zr_{3}B_{4}Ag_{x}$ 박막을 DC 마그네트론 스퍼터링법으로 제조하였다. 그리고, 300-600$^{\circ}C$ 온도 범위에서 1시간동안 열처리한 후 강제공냉법으로 냉각한 후 XRD를 이용하여 열처리 온도 및 Ag 첨가량에 따른 결정상 동정을 조사하였다. Ag가 첨가되지 않은 $Fe_{93}Zr_{3}B_4$ 박막의 경우 $\alpha$-Fe의 (110) 피크만 관찰되었다. Ag가 첨가된 경우에는, Ag의 양이 증가함에 따라 $\alpha$-Fe 결정상의 형성이 억제되고, 비정질형태의 broad한 ${\alpha}-Fe_{(110)}$ 피크와 Ag피크가 관찰되었다. Ag가 첨가된 As-deposited 시편을 열처리 할 경우 박막의 비정질화로 주 peak인 $\alpha$-Fe 피크의 강도가 현저히 낮아지고 상대적으로 Ag peak가 두드러졌다. Ag의 양이 3a/o인 경우는 열처리온도 400$^{\circ}C$이상에서 박막의 결정화로 $\alpha$-Fe Peak가 나타나고 상대적으로 Ag 구성원소의 피크의 강도는 현저하게 낮아졌다 또한. Ag의 양 증가할수록 As-deposited 박막 내에 Ag 구성원소외 피크의 강도는 증가하여 $\alpha$-Fe와 Ag가 서로 비고용 상태로 서로 혼재되어 있었다.

  • PDF

Noise Control for Diesel Engine Generator Sets (디젤 엔진 발전기 세트의 소음제어)

  • 남경훈;주현돈;최부군;박실룡
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.165-170
    • /
    • 1995
  • 소음저감 설계기술은 제품의 경쟁력 향상을 위해 일반인이 쉽게 접근할 수 잇는 가전제품, 자동차, 항공기 분야 등에서 많은 연구가 수행되어 왔으며, 최근 소음환경 규제가 강화되고 대형기계의 설치 위치가 주거지역과 가까워지므로 산업용 기계설비의 소음제어에 대한 관심이 점차 증대되고 있다. 특히 디젤 엔진 발전기 세트를 이용해서 전원을 공급하는 산업용 기계에 있어서는 디젤 엔진과 발전기가 주소음원이며, 크게 기계적 소음, 공기 역학적 소음, 그리고 전자기 소음 등으로 분류된다. 본 연구는 이러한 소음을 발생시키는 엔진(Engine), 발전기(Generator), 방열팬(Radiator Fan) 등의 성능을 개선시켜 소음을 감소시키는 것이 아니라, 외부 덮개(Canopy)에 흡음재를 부착하여 소음저감 방법을 채택했다. 연구대상으로서는 항만에서 컨테이너(Container)를 운송하는 이동용 크레인(Transfer Crane)의 엔진 발전기 세트(set)로서, 각 구성품(엔진, 발전기, 방열 팬)의 음향 덮개의 내부구조를 설계하였다. 그리고 덮개 내부 온도를 일정하게 유지시키기 위하여 엔진에서 방사하는 방열공기와 내부로 흡입되는 냉각공기의 열유동장 해석도 병행하였다.

  • PDF

OUTGASSING OF GFRP, CFRP AND GRAPHITES

  • 최상철;정광화;홍승수;서인용;신용현;이상균;임종연;임인태
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.38-38
    • /
    • 2000
  • 저온유지장치에서 요구되는 도달압력은 초전도 코일의 냉각시스템과 저온유지장치의 벽 사이의 진공단열조건으로부터 결정될 수 있으며, 기체에 의한 열전도의 영향을 방지하기 위해서는 5$\times$105Torr 이하의 진공도가 요구된다. 저온유지장치 내에서 진공 단열재로 사용되는 Glass Fiber Reinforced Plastic(GFRP)과 Carbon Fiber Reinforced Plastic(CFRP)의 기체 방출률을 측정하였다. 고출력 토카막 방전동안 graphite limiter 표면의 온도는 200$0^{\circ}C$ 이상이며, 플라즈마로 유입되는 불순물의 양을 줄이기 위해 많은 시도를 하고 있다. 상온에서부터 약 100$0^{\circ}C$까지 승온에 따른 방출기체의 양 및 성분 분석, annealing 후 공기 중에 약 2주간 노출 후 기체 방출률과 성분을 분석하였다. 총 기체 방출량은 10$0^{\circ}C$ 근방에서 급격히 증가하여 $600^{\circ}C$부터는 graphite의 종류에 관계없이 거의 일정한 분포를 보이며, 최대 방출률은 약 20$0^{\circ}C$~30$0^{\circ}C$ 부근에서 나타났다.

  • PDF