• 제목/요약/키워드: 냉각수 해석

검색결과 164건 처리시간 0.024초

Numerical Study on the CO and NO of Rocket Plume as the Type of Water Injection in the Flame Guiding Duct (화염유도로 냉각수 분사방식에 따른 로켓 플룸의 CO와 NO 반응의 수치해석)

  • Kim, Seong-Lyong;Kim, Seung-Han;Han, Yeoungmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • 제19권3호
    • /
    • pp.39-46
    • /
    • 2015
  • A numerical study has been conducted on CO after burning and NO generation of the rocket plume as the cooling water injected to the rocket plume. The present study shows that the cooling water has a role of increasing the degree of CO after burning and reducing NO generation. However the effect varies as the injection configuration of the cooling water. When the cooling water is injected at the side of the plume, NO generation is dramatically reduced while the degree of CO after burning is relatively low. When the cooling water is injected at the side and the center of the plume, CO after burning is highly increased and NO generation is also dramatically reduced.

Computer Simulation of Solidification Process in the Gravity Die Casting of Cast Iron (주철의 중력금형주조에서 응고과정의 컴퓨터해석)

  • Choi, Jeong-Kil;Hong, Chun-Pyo
    • Journal of Korea Foundry Society
    • /
    • 제10권3호
    • /
    • pp.247-253
    • /
    • 1990
  • 주철의 중력금형주조에서 반복작업에 따른 응고과정의 변화를 3차원의 수치해석적 방법에 의하여 컴퓨터해석을 하였다. 수치해석적 방법으로는 차분법을 채택하였다. 반복작업과정에 따라 변화되어지는 주물의 응고시간과 미세조직, 기계적성질과의 관계가 조사 되어졌다. 컴퓨터에 의해 계산된 각싸이클의 냉각속도로 부터 주물의 공정셀의 수, 경도, 인장강도등의 변화를 예측하였으며 또한 반복싸이클에 따른 금형 및 주물의 온도분포와 최종응고부위등을 예측하였고 이들은 실제주조시험에서 얻어진 결과와 비교적 잘일치하였다. 중력금형주조에서 회주철의 응고시간, 공정셀, 기계적성질 및 응고속도에 미치는 냉각수의 영향이 또한 컴퓨터해석에 의하여 잘예측되었으며 컴퓨터해석에 의한 냉각수 라인의 적절한 설계에 의하여 주물의 미세조직 및 기계적성질과 결함발생 가능위치를 효과적으로 제어할수 있음을 확인하였다.

  • PDF

Cooling Performance Analysis of a Sub-scale Calorimeter (축소형 칼로리미터의 냉각성능 해석)

  • 조원국;문윤완
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • 제7권3호
    • /
    • pp.8-14
    • /
    • 2003
  • A cooling performance analysis has been made in the 8-channel calorimeter based on sub-scale KSR-III engine. Three-dimensional heat transfer analysis in cooling channels has been performed using the heat flux distribution through the chamber wall predicted from axi-symmetric compressible flow inside the combustion chamber. The heat flux distribution is verified against the published literature. Presented for the development and operation of the calorimeter are the coolant pressure drop, coolant temperature rise and the maximum chamber wall temperature. Required coolant flow rate is determined for given chamber pressure. Cooling performance is also predicted for temperature dependant coolant properties.

증기주입기 계통 해석 코드 개발

  • 이경진
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.126-131
    • /
    • 1996
  • 증기주입기간 고온, 고압의 증기 열에너지를 운동에너지로 전환하여, 저압의 피주입수를 고압의 계통으로 펌핑하는 장치를 말한다. 원자로에서 과도상태나 사고 발생시, 저온 저압의 냉각수를 고온 고압의 계통으로 주입시켜야 되는 상황이 종종 발생한다. 기존 원자로의 경우 먼저 여러 가지 능동적인 수단을 사용하여 계통의 압력을 떨어뜨린 후, 능동기기를 사용하여 냉각수를 주입시킨다. 냉각수를 주입시키기 위해서는 먼저 계통의 압력을 떨어뜨려야 한다. 기존 방식의 단점으로는 감압이 어렵고, 능동기기에 대한 전원 유지가 필수적이며, 능동기기(펌프)의 고장 가능성을 들 수가 있다. 증기주입기는 감압 및 구동력이 필요하지 않고, 움직이는 부분이 없이 노즐과 밸브로만 구성되어 있이, 냉각수 주입계통의 신뢰도를 크게 향상시킬 수 있다. 따라서 광범위한 운전 조건하에서 안정되게 작동할 수 있는 증기주입계통을 개발하기 위한 분석 기법연구 및 분석 코드를 개발하였다.

  • PDF

Stabilization of Water Balance of Closed Cooling Water System with Orifice (오리피스를 통한 기기냉각수 계통 Water Balance 정상화)

  • Lee, Sung Gun;Park, Jong Hwan;Lee, Eun Su
    • Plant Journal
    • /
    • 제13권4호
    • /
    • pp.38-40
    • /
    • 2017
  • This study is for stabilization of the water balance of the closed cooling water system. The pipe network analysis program is used for the water balance review, and the resistance factor correction is performed through the field measurement with the ultrasonic flowmeter to improve the reliability of the pipe network software. Based on this, it is aimed to derive optimal driving method through various case simulations.

  • PDF

Cooling Performance Analysis of Sub-scale Calorimeter (축소형 칼로리미터의 냉각성능 해석)

  • 조원국;문윤완
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 한국추진공학회 2003년도 제20회 춘계학술대회 논문집
    • /
    • pp.9-12
    • /
    • 2003
  • A cooling performance analysis has been made in the 8-channel calorimeter based on sub-scale KSR-III engine. Three-dimensional heat transfer analysis in cooling channels has been performed using the heat flux distribution through the chamber wall predicted from axi-symmetric compressible flow inside the combustion chamber. The heat flux distribution was verified against the published literature. Presented for the development and operation of the calorimeter are the coolant pressure drop, coolant temperature rise and the maximum chamber wall temperature.

  • PDF

An Analysis on the Temperature Safety of a Boiler Desuperheater (보일러 과열증기 냉각기의 온도 안전성에 관한 연구)

  • Ha, Ji-Soo;Kim, Tae-Kwon;Chang, Hyuk-Sang
    • Journal of the Korean Institute of Gas
    • /
    • 제16권2호
    • /
    • pp.9-13
    • /
    • 2012
  • The present study has been carried out to diagnose the temperature safety of a boiler desuperheater which decreases abnormally higher temperature of superheated steam in a reheater of a power plant. The liquid water in the desuperheater stays in a closed space. It becomes heated by the high temperature superheated steam and boiling could occur. Boiling might increase internal pressure and it could destroy the desuperheater if the internal pressure exceeds the allowable pressure of the desuperheater. The present study modeled reasonably the desuperheater and four cases of heat transfer analysis are executed with the consideration of insulator and natural convective fluid flow of the inside cooling water. For the case excluded the natural convective fluid flow, the temperature exceeds the allowable temperature and pressure. On the other hand, for the real case included natural convective fluid flow and insulator, the active heat transfer from higher temperature region to lower temperature region occurs and it makes the temperature in the cooling water below the allowable temperature and pressure. From this fact, it could be thought that the desuperheater in the reheater is safe from destroy or back flow.

Numerical Study on Thermal Performances of Multi Heat Source Heating System Using Butane for Electric Vehicle (전기자동차용 부탄 연료 복합열원 히팅시스템의 열적 성능에 관한 수치적 연구)

  • Bang, You-Ma;Seo, Jae-Hyeong;Patil, Mahesh Suresh;Cho, Chong-Pyo;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제17권10호
    • /
    • pp.725-731
    • /
    • 2016
  • This study numerically investigates the thermal performance of a 2.0-kW butane-based combustion heating system for an electric vehicle under cold conditions. The system is used for cabin space heating and coolant-based battery thermal management. ANSYS CFX 17 software was used for parametric analysis. The mass flow rates of cold air and coolant were varied, and their effects were compared. The numerical results were validated with theoretical studies, which showed an error of 0.15%. As the outside air mass flow rates were increased to 0.005, 0.01, and 0.015 kg/s, the cabin supply air temperature decreased continuously while the coolant outlet temperature increased. When the coolant mass flow rates were increased to 0.005, 0.01 and 0.015 kg/s, the air temperature increased while the coolant outlet temperatures decreased. The optimal mass flow rates are discussed in a consideration of the requirements for high cabin heating capacity and efficient battery thermal management.