• Title/Summary/Keyword: 내화구조

Search Result 482, Processing Time 0.029 seconds

Study of the Standard Testing Specifications for a Non-loading Performance Evaluation of Coating Material-sprayed Circular Steel Structures (뿜칠 피복 원형 철골구조의 비재하 내화성능 평가용 시험체 제안을 위한 연구)

  • Ok, Chi-Yeol;Kim, Jae-Jun
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.7-15
    • /
    • 2016
  • The cross-sectional shape factor is used worldwide to evaluate the scientific performance of fire-resistant structures. In South Korea, however, a system for applying a cross-sectional shape factor has not been arranged and circular or rectangular steel pipes are commonly used for large-scale steel frame buildings. On the other hand, coating material-spray steel beams and pillars that have received the certification of a fire-resistant structure from recognized organizations are mostly limited to a H-beam. A H-beam is granted a wide range of certifications without size limitations from a non-loading performance test with test standards based on the relevant provisions. Other types of steel pipe are to be certified for fireresistance according to shape. In this study, a cross-sectional shape factor was used to propose standard testing specifications for the application of coating material-sprayed circular and rectangular steel pipes, eventually to set the scope of certification for reasonable fire-resistant structures.

Fire Resistance Properties of High Strength Concrete Column using ECC Permanent Form (ECC 영구 거푸집을 활용한 고강도콘크리트 기둥부재의 내화특성)

  • Kim, Yong-Ro;Song, Young-Chan;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.957-960
    • /
    • 2008
  • In this study, it was investigated fire resistance properties of high strength concrete column using Engineered Cementitious Composites(ECC) permanent form as a countermeasure for explosive spalling of concrete on fire. As a test result, it was appeared that ECC permanent form is available as fire resistance method of high strength concrete if it is developed manufacturing technique and scheme for application controlling heat penetration through interface of permanent form and high strength concrete, and setting up mix proportion and thickness of ECC.

  • PDF

Experimental Study on the Fire Proofing Characteristic of Fire Resistance Panel that it attaches to PSC Airpit-Slab (PSC 풍도슬래브에 부착된 내화패널의 내화특성에 관한 실험연구)

  • Lee, Doo Sung;Bae, Jeong;Choi, Heon;Min, In Gi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.465-473
    • /
    • 2013
  • In this Study, the performance of precast PSC slabs with fire resistance panel for fire resistance of the tunnel system was evaluated by experimentally. The fire test was performed in fire resistance (electric) furnace according to RABT(Richtlinien fur die Ausstatung und den Betrieb von stra${\beta}$entunneln) time heating temperature curve. The test results showed that the measured temperatures at the t=0 mm depth of PSC slab with precast fire resistance panel during a fire was maximum temperature $367^{\circ}C$, lower than $380^{\circ}C$ (ITA 2004), when damage occurs. Also, at the t=25 mm, the maximum temperature was $239^{\circ}C$, which was lower than the damage temperature of rebar, $250^{\circ}C$. From the results, the use of precast fire resistance panel (t=25 mm) improves fire resistance of PSC structures.

Improvement of Fire Resistance for Timber Framed Walls by Reinforcement of Heavy Timber Frame

  • Park, Joo-Saeng;Hwang, Kweon-Hwan;Kim, Kwang-Mo
    • Journal of the Korea Furniture Society
    • /
    • v.21 no.6
    • /
    • pp.469-478
    • /
    • 2010
  • Fire resistance of new hybrid timber framed wall systems was evaluated in this study. These wall systems are composed of two major structural parts. One part is a heavy timber frame part designed to take charge of whole vertical load using heavy timber post and beam, and the other is an infill wall structure, designed to take charge of whole horizontal load and to provide an established level of fire resistance. A basic concept of this hybrid wall is adopted from a typical furniture structure with frame. A timber post and beam frame is constructed with Japanese Larch solid timber post(180mm by 180mm) and beam(180mm by 240mm). As infill wall systems, two types of walls are applied. One is a typical light timber framed wall with solid blocking and another is a structural insulated panel wall, in which polystyrene insulation is filled between two structural panels to make single structure. For all tested walls, two layers of 12.5mm thick type-X gypsum boards are used on fire exposed side. Prior to tests for hybrid walls, only infill walls are tested without heavy timber frame. All fire resistance tests are carried out in accordance with KS F 2257, and temperatures on several points within wall structure and unexposed wall surface are measured during fire tests. It is considered that the reinforcement of heavy timber frame is significantly efficient for improving the fire resistance of timber framed walls.

  • PDF

Assessment of structural fire resistance of a fire-proofed immersed tunnel under tunnel fire scenarios (화재시나리오별 침매터널 구조물의 화재저항성 평가)

  • Choi, Soon-Wook;Chang, Soo-Ho;Kim, Heung-Yon;Jo, Bong-Hyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.6
    • /
    • pp.429-441
    • /
    • 2010
  • In this study, fire resistance of a fireproof material sprayed upon an immersed tunnel was experimentally evaluated under $HC_{inc}$ and IS0834(duration of 4 hours) fire scenarios. Under $HC_{inc}$ fire scenario, the maximum inner temperatures of a concrete specimen at the depth of 0, 25 and 50 mm from the interface between the structure and the fire-proofing layer were $311^{\circ}C$, $194^{\circ}C$ and $142^{\circ}C$ respectively. Similarly, the corresponding maximum temperatures under IS0834 fire scenario were $332^{\circ}C$, $222^{\circ}C$ and $179^{\circ}C$ respectively. From the results, it was revealed that the two different fire scenarios assumed in this study have almost the same fire capacity as each other in the maximum temperature concept. In addition, a structural analysis of the immersed tunnel under $HC_{inc}$ fire scenario was carried out to verify the effects of the fireproof material on its structural stability. Material loss and deterioration of a concrete specimen without any fire-proofing measure was also experimentally evaluated to obtain input parameters for the structural analysis under such a severe fire scenario. From the results, it was confirmed that the application of fireproof measures to the immersed tunnel is essential for its structural stability even under a severe fire scenario.

Fire Resistance Performance of Precast Segmental Concrete Lining for Shield Tunnel (쉴드 터널용 프리캐스트 세그먼트 콘크리트 라이닝의 내화성능)

  • Han, Byung-Chan;Harada, kazunori;Kwon, Young-Jin;Kim, Yun Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.95-105
    • /
    • 2014
  • Reinforced concrete (RC) shield tunnel lining must be designed for fireproof performance because the lining is sometimes exposed to very high temperature due to traffic accidents. Both experimental and numerical studies are carried out to evaluate fire resistance performance of precast RC tunnel lining systems. In the experimental studies, six full-scale precast RC tunnel segments are exposed to fire in order to examine the influence of various parameters on the fire resistance performance of precast RC tunnel lining. We used the temperature curve of the RABT criteria, which are severe conditions of fire temperatures. The fire test showed that the explosive spalling was not observed by substituting concrete to PP fiber reinforced concrete. A transient heat flow analysis was carried out in consideration of the material properties that change with temperature, and the results showed good agreement with the test results.

State-of-the-Art Research and Experimental Assessment on Fire-Resistance Properties of High Strength Concrete (고강도 콘크리트의 내화 특성에 관한 기존연구 고찰 및 실험적 연구)

  • Kim, Woo-Suk;Kang, Thomas H.K.;Kim, Wha-Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.28-39
    • /
    • 2014
  • This paper reviews past literatures relevant to fire-resistance properties of high strength concrete and investigates spalling mechanism of high strength concrete in fire. First, literatures were reviewed on spalling occurrence and fire-resistance methods. Second, a chemical change of concrete components in an elevated temperature was presented. Finally, the mechanism of the spalling occurrence and spalling resistance were examined in terms of hybrid fiber content. The focus of the experimental study as part of this research is to investigate the effects of fire on the variation of thermal properties of high strength concrete, which tends to be used in super tall buildings. This experimental study was devised to investigate the fire-resistance performance of high strength concrete containing hybrid fibers. A total of 48 test specimens were exposed to high temperature ranging from $100^{\circ}C$ to $700^{\circ}C$, including room temperature (${\sim}20^{\circ}C$). Test results provide valuable information regarding fire-resistance properties of strength concrete with 100 MPa or greater.

Development of Vermiculite Board to Secure the Fire Resistance Performance of Light-Frame Wood Structural Wall (경골목구조 벽체의 내화성능확보를 위한 질석보드 개발)

  • Yoo, Seok Hyung;Cheong, Chang Heon
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.40-45
    • /
    • 2018
  • It is considered that vermiculite as an inorganic material is highly effective when it is used as a building finishing material because it is eco-friendly. Vermiculite has excellent properties such as fire resistance, heat insulation, sound absorption as well as prevention of condensation, deodorization and aesthetics. In this study, we developed a finishing board with vermiculite as its main material and mixed with mineral loose wool (VB-L) or mineral powder (VB-P), and conducted fireproof test and insulation test. In addition, fire resistance tests were carried out by applying the two developed vermiculite boards as finishing materials for the standard wall details of light frame wood structures (KS F 1611-1). As a result of the fire resistance test, the VB-L specimen showed better fire resistance than the VB-P specimen. Both vermiculite boards showed sufficient fire resistance performance of 2 hours for a thickness of 30 mm.

A Study on the Analytical Method for Fire Resistance Calculation of Asymmetric Slimfloor Beam (비대칭 슬림플로어 합성보의 내화성능 산정에 관한 해석적 방법 연구)

  • Park, Soo-Young;Park, Won-Sup;Kim, Heung-Youl;Hong, Gap-Pyo
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.31-37
    • /
    • 2010
  • Asymmetric Slimfloor Beam (ASB) is a composite beam developed in Europe whose asymmetric H beam is partially inserted in concrete slab. Recently in Korea, Asymmetric Slimfloor Beam has been studied in order to save the story height of a building, reduce the amount of construction materials and increase the fire resistance of a building. On this study, the fire resistance of Asymmetric Slimfloor Beam was checked by a fire test and moment capacity was calculated at fire resistance time by a heat-transfer analysis. Using the analysis result, 3-hour fire resistance constructions consisted of fireproof gypsum boards and ASB were selected and fire resistances of selected constructions were checked.