• Title/Summary/Keyword: 내진장치

Search Result 178, Processing Time 0.021 seconds

Study on Seismic Analysis and Test for Seismic Qualification of 245kV GIS (245kV 가스절연개폐장치의 내진성능 실증을 위한 시험 및 해석)

  • Kim, Yu-Gyeong;Kwon, Tae-Hoon;Jeong, Yeong-Jin;Kim, Hong-Tae;Kim, Young-Joong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.5
    • /
    • pp.715-722
    • /
    • 2013
  • Gas insulated switchgear is large-sized electric equipment for providing a reliable supply of electric power. Recently, seismic tests of electric equipment using a shaking table have been mandated because seismic performance has become an increasingly important issue. However, basic analysis methods continue to be used because some electric equipment is too large for shaking table facilities. Thus, a reliable analysis method should be developed for large-scale electric equipment. This study aims to evaluate the seismic qualification of a 245kV GIS in accordance with IEEE-693 and to validate the analysis method by comparing it with test results. Both the test and the analysis showed that the 245kV GIS has proper seismic safety. Furthermore, the differences between the analysis and the test results are less than 10% for an accurately given mass, stiffness, and input acceleration. It is expected that this study can be used for the seismic qualification of large-scale electrical structures.

Study on Seismic Performance of Steel Structure with Precast Concrete Cladding Panel and Connector Considered as Structural Components (외부벽판과 연결부재를 구조요소로 취급한 경우 철골구조물의 내진성능에 관한 연구)

  • Byeon, Ji-Seok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.2
    • /
    • pp.127-133
    • /
    • 2008
  • The purpose of this study is to investigate the seismic performance of both exterior precast concrete cladding panels and their connections on steel frame, when these cladding systems are considered as the structural components. The degrees of their participation of lateral stiffness to the main building are evaluated in terms of different heights of the cladding panels. Considering the cladding system as an integrated building provides additional lateral stiffness, as well as a mechanism for energy dissipation and this system can be used as one of an advanced passive seismic control system. Hysteresis behaviors of connectors are modeled and integrated into a nonlinear finite element analysis program, ABAQUS. The results show that connections play the most important role in structural cladding system and they improve seismic performance of overall building response.

Seismic Analysis of Traveling Sea Water Screen (해수여과장치의 내진해석)

  • Kim, Heung-Tae;Lee, Young-Shin;Park, Young-Moon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.3
    • /
    • pp.289-294
    • /
    • 2011
  • In this study, the seismic analysis of traveling sea water screen for nuclear power plant was performed using finite element model. For qualification of traveling sea water screen, the response spectrum analysis was performed using the given operating basis earthquake(OBE) and safe shutdown earthquake(SSE) floor response spectrum. Dynamic analysis of water sea traveling screen was performed using finite element method. The analytical maximum displacements of traveling sea water screen were 2.5 mm under OBE condition and 4.6 mm under SSE condition. The maximum stresses of traveling sea water screen were 24 MPa under OBE condition and 44 MPa under SSE condition, that this results were 18 %, 27% of yield strength of material. Thus, it can shown that the structural integrity of traveling sea water screen has a stable structure for seismic load conditions.

Dynamic Responses of Base Isolation Devices for Telecommunication Equipment in Building Structures (건축물 내 방송통신설비를 위한 면진장치의 동적거동)

  • Jeong, Saebyeok;Choi, Hyoung-Suk;Seo, Young-Deuk;Jung, Donghyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.39-48
    • /
    • 2022
  • In earthquake situations, broadcasting and communication services are directly linked to rapid on-site rescue and effective restoration works. Recently, a variety of base isolation devices are widely introduced on building floors to avoid critical seismic damages of telecommunication facilities. However, in buildings with long fundamental periods, those devices may have undesirable amplification of seismic responses due to resonance effect between the building floors and base isolation devices. This study performs the seismic safety evaluation of two types of base isolation devices deployed for telecommunication facilities in mid- and high-rise buildings through numerical and experimental approaches. It is found that mid- and high-rise buildings can have low-frequency dynamic responses at the top floor when being subjected to design basis earthquake loading. Furthermore, bi-directional shake table testing demonstrated that the selected base isolation devices can exhibit unstable dynamic behaviors under such low-frequency excitations of the floor.

Evaluation of Seismic Performance for Various Types of Pile Head of Landing Pier (잔교식 안벽에서 말뚝 두부형식에 따른 내진성능 평가)

  • Jang In-Sung;Kwon O-Soon;Park Woo-Sun;Jeong Weon-Mu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.17 no.2
    • /
    • pp.70-79
    • /
    • 2005
  • Most of landing piers in Korea employ the combination of vertical piles and batter piles, which shows good efficiency in static lateral resistance but poor seismic performance. Many attempts have continuously been made to increase the seismic performance of batter piles with various aseismatic systems. In this study, new types of aseismatic system were developed by use of rubber and ball bearing, and shaking table tests and 3 dim. numerical analyses were performed in order to compare the seismic performance for various types of pile head. The test and numerical analysis results show the high seismic performance of newly proposed systems and the applicability off dim. numerical analysis considering the non-linear behaviour of rubber and ball bearing systems.

A Study on the Seismic Performance of Energy-Dissipating Sacrificial Devices for Steel Plate Ginder Bridges (강합성 거더교에 적용된 희생부재형 에너지소산장치의 내진성능에 관한 연구)

  • Cho, Kwang-Il;Gwak, Pil-Bong;Mha, Ho-Seong;Kim, Sang-Hyo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.3 s.55
    • /
    • pp.87-96
    • /
    • 2007
  • A new Energy-Dissipating Sacrificial Device (EDSD) is developed for steel plate girders, which can effectively dissipate the energy stored in the structures during seismic actions. To verify the performance of the EDSD, various seismic responses of a sample bridge with the EDSD are analyzed in terms of energy, member forces and deformation. The full scale model tests are conducted to certify the performance of the EDSD when it is applied on existing bridges. Using the improved hysteretic model of the sacrificial member, the seismic analysis for an example bridge is performed. The results show that the proposed EDSD under seismic excitations can significantly decrease the energy stored in the bridge structures and reduce the relative displacements of each superstructure to the ground. The EDSD is also found to function as a structural fuse under strong ground motions, sacrificing itself to absorb the excessive energy. Consequently, economical enhancement of the seismic performance of bridges can be achieved by employing the newly developed energy-dissipating sacrificial device.

Design Methods of the Longitudinal Motion-Limiting Devices in Multi-Span Continuous Bridges (다경간연속교의 교축방향 이동제한장치의 설계방법)

  • 전귀현;이지훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.145-154
    • /
    • 1998
  • The motion-limiting devices can be used for reducing the maximum and residual displacements of the multi-span continuous bridges with inelastic elements such as isolation bearings and plastic hinges formed in piers. For the design of motion-limiting device, the nonlinear time history analysis is required. But the time history analysis is time consuming and very complex. This study suggests the simple design procedure of the motion-limiting devices using the equivalent elastic analysis method and the acceleration-displacement spectrum concept. The suggested design procedure can be used very effectively for determining the location and gap size of the motion-limiting devices.

  • PDF

Experimental Study on the Characteristics of Steel Hysteretic Dampers with E-Shape Elements (E-Shape 강재이력댐퍼의 거동 분석)

  • 김인배;강형택;이민구;서주원
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.457-464
    • /
    • 2003
  • 최근 교량의 건설에 있어서 내진설계가 주요문제로 부각되면서, 구조물의 진동응답을 제어 하는 갖가지 형태의 진동제어 기법이 적용되고 있다. LRB(Lead Rebbe. Bearing), LUD(Lock Up Device)등 다양한 지진격리장치가 설계에 적용되고 있으며 특히, 설계변경 .내진보수보강과 같이 제약 조건이 있는 상황에서 유용한 면진방법으로 사용되고 있다. 이러한 지진격리장치는 기본적인 설계특성인 수평강성, 감쇠성능에 대한 검증을 필요로 한다. 특히, 지진과 같은 동적하중에 대하여 하중속도, 수직력, 변형률 등에 대한 의존성과 내구성의 검토가 필요하며 유사장치에 대하여 검증실험기준의 정립이 진행 중에 있다. 강재이력댐퍼인 E-Shape 댐퍼는 지진격리장치로서 교각의 고정단에 교좌장치로 설치되어 상시에는 탄성영역 내에서 거동하는 고정단의 역할을 하다가, 지진발생시에는 E-Shape형태의 강재댐퍼가 소성변형을 통한 이력거동으로 에너지 소산기능을 가진 교좌장치이다. 최근 LRB에 대하여는 다양한 특성실험이 수행되고 있으나 상대적으로 강재이력댐퍼에 대하여는 이러한 검증실험이 수반되지 않고 사용되고 있다. 본 실험연구에서는 E-Shape 강재이력댐퍼에 대하여 연직하중, 수평변형률, 수평속도에 패한 동적특성을 평가함으로서 강재이력댐퍼를 이용한 지진격리설계의 타당성과 면진성능을 평가해 보았다.

  • PDF

Test of RC Structures with Friction Damper (마찰형 댐퍼가 있는 RC 구조물에 관한 실험적 연구)

  • Kim, Young Ju;Ahn, Tae Sang;Lee, Chang Hwan;Kim, Sang Dae
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.30-30
    • /
    • 2011
  • 국내의 내진설계 기준은 1988년에 처음 도입되었으며, 최근 점차 강화되고 있는 실정이다. 공동주택에 주로 적용되는 전단벽식 구조시스템에서 증가된 지진력에 저항하기 위해서는 벽량과 철근이 증가하게 되어 공사비가 상승하게 된다. 이러한 단점을 보완하기 위한 제진설계의 필요성이 대두되고 있는 실정인데, 기존의 제진장치는 주로 가새형 또는 벽체형을 대부분이라 평면계획에 제약이 있다. 따라서 전단벽식 구조의 공동주택의 제진설계 시에는 우리나라와 같은 중 약진 지역에 적합하고 저렴한 비용으로 충분한 내진성능과 평면의 가변성을 확보할 수 있는 댐퍼의 선택이 필요하다. 본 연구의 목적은 기존의 가새형 및 벽체형 제진장치의 국내 공동주택 적용시의 문제점인 평면의 가변성 확보에 유리하고, 수동형 제진장치의 장점을 추구할 수 있는 마찰댐퍼를 삽입한 커플링보 제진시스템의 내진성능을 조사하는 것이다. 내진성능을 평가하기 위해서 실대형 커플링보 실험체를 계획하고 제작하였다. 실험체는 2개로 구성되어 있으며, 하나는 기존의 철근배근 상세를 갖는 철근콘크리트 커플링보 실험체와 커플링보에 마찰댐퍼가 삽입된 실험체이다. 횡하중에 대한 성능을 평가하기 위해서 유사정적 반복가력실험을 실시하였다. 엑츄에이터로부터 실험체 상보의 가력지그를 통해 하중이 전달되도록 하였으며, 가력은 최초 0.25%의 층간변형각부터 변위제어를 통해 목표 층간변형각인 1.5% 이상까지 진행되도록 하였다. 실험결과, 두 실험체의 이력곡선과 에너지 흡수능력을 평가하였다. RC 실험체는 핀칭현상이 관찰되었고, 가력이 진행됨에 따라 커플링보와 벽체에서의 균열이 확산되어 종국적으로 취성적인 커플링보의 전단파괴가 발생하였다. 마찰댐퍼를 삽입한 실험체는 계획된 마찰거동이 잘 발휘되어 목표 층간변형각인 1.5%까지 이선형거동이 잘 나타났다. 최대 내력은 RC 실험체가 3배 이상 크지만, 누적층간변형각에 따른 에너지 흡수능력은 마찰댐퍼 실험체가 2배 이상 우수한 결과를 보였으며, 커플링보 및 벽체에서의 균열이 매우 저감되었다.

  • PDF

Seismic Performance Evaluation of R/C Frame Apartment Strengthened with Kagome Truss Damper External Connection Method by Pseudo Dynamic Test (유사동적실험에 의한 외부접합형 카고메 트러스 제진장치가 설치된 RC 라멘조 공동주택의 내진성능 평가)

  • Heur, Moo-Won;Chun, Young-Soo;Hwang, Jae-Seung;Lee, Kang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.23-34
    • /
    • 2015
  • Recently a new damper system with Kogome truss structure was developed and its mechanical properties were verified based on the laboratory test. This paper presents a Kagome truss damper external connection method for seismic strengthening of RC frame structural system. The Kagome external connection method, proposed in this study, consisted of building structure, Kagome damper and support system. The method is capable of reducing earthquake energy on the basis of the dynamic interaction between external support and building structures using Kagome damper. The pseudo-dynamic test, designed using a existing RC frame apartment for pilot application of LH corporation, was carried out in order to verify the seismic strengthening effects of the proposed method in terms of the maximum load carrying capacity and response ductility. Test results revealed that the proposed Kagome damper method installed in RC frame enhanced conspicuously the strength and displacement capacities, and the method can resist markedly under the large scaled earthquake intensity level.