• Title/Summary/Keyword: 내진장치

Search Result 177, Processing Time 0.023 seconds

A Study on Aseismatic Performance of Base Isolation Systems Using Resilient Friction Pot Bearing (탄성마찰포트받침을 적용한 교량의 내진성능에 관한연구)

  • Oh, Ju;Hyeon, Gi Hwan;Park, Yeon Su;Park, Seong-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.1
    • /
    • pp.127-134
    • /
    • 2008
  • For more districted seismic design and attemped multi-bridge continuity, the existing seismic design is difficulted to treat seismic activity. So, many company applied multi-fixed point and damper or isolator, which is effective for decreasing seismic energy, on period shift, decentralization and damping. But, there is hard to design special bridge with adjusted seismic system because of absence seismic device and insufficient design experience. Therefore, the study on behavior characteristics of designed bridge with various seismic device is performed to utilize the result of this for selection of adequate seismic device.

A Consideration of Earthquake Simulation Test for Telecommunication Equipment Rack (통신 장치랙 지진모사 실험에 대한 고찰)

  • Kang, Wang-Kyu;Han, Jin-Woo;Woo, Byung-Soo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.296-301
    • /
    • 2007
  • 2007년 1월 20일 20시 56분경 오대산 부근에서 발생한 지진이 제주도를 제외한 전국에서 감지되어 우리 생활에 직접적인 영향을 끼치는 등 더 이상 우리나라도 지진에 안전한 나라가 아니라는 것이 입증되고 있으며, 정부에서도 자연재해대책법에 통신설비에 대한 내진설계 의무화 규정을 포함시켜 현재 시행을 눈앞에 두고 있는 시점에서 통신시설물에 대한 내진성능 평가와 내진대책 수립이 절실히 요구되고 있다. 따라서, 본 논문에서는 지진 발생시에 가장 민감하게 반웅하며 피해가 클 것으로 예상되는 통신 장치랙에 대하여 전력설비의 내진성능 검증에 사용되는 인공 지진파와 미국에서 측정한 실측 지진파를 진동대에 입력, 지진모사 실험을 실시하여 지진시 발생할 수 있는 통신장비의 기능 이상 유무를 확인하고 동적 거동 특성을 분석함으로써 장치랙이 보유한 내진성능을 도출하여 보았다. 이러한 지진모사 실험은 향후 통신 장치랙의 내진성능을 평가하는 기준을 수립하는데 중요한 기초자료로 활용될 것이라 판단된다.

  • PDF

A Consideration of Seismic Design Technologies for Telecommunication Equipment (Rack) (장치(랙) 내진설계 기술에 대한 고찰)

  • Han Jin-Woo;Woo Byung-Soo;Kang Wang-Kyu
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.122-127
    • /
    • 2006
  • 최근 일본에서 발생한 지진이 우리나라에 직접적인 영향을 끼치는 등 더 이상 우리나라도 지진에 안전한 나라가 아니라는 것이 입증되고 있으며, 과도한 지진 발생시 통신두절에 따른 파급효과를 감안할 때, 이제는 본격적으로 통신시설물에 대한 내진대책을 강구할 필요가 있다. 통신시설물은 크게 통신빌딩(전화국 건물), 옥내시설(통신설비, 전원설비, 기계설비), 옥외시설(통신구, 관로 및 맨홀, 철탑, 위성안테나, 전주 등)로 구분하는데, 통신빌딩을 제외하고는 확실한 내진규정이 없는 실정으로 지진에 가장 민감한 시설로 옥내시설의 통신설비인 장치(랙)으로 알려져 있다. 따라서, 본 논문에서는 치국의 장치(랙)에 대한 내진실험 및 기준을 고찰하였으며, 이를 토대로 우리나라에서 적용할 수 있는 장치(랙)의 내진성 확보 방안을 제시하였다.

  • PDF

Improvement of Seismic Performance of Existing Bridges using Isolation (지진격리장치를 이용한 기존 교량의 내진성능 향상)

  • 한경봉;김민지;박선규
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.2
    • /
    • pp.9-17
    • /
    • 2004
  • The seismic performance evaluation and retrofit process are very important in old existing bridges. If the result is not appropriate. then a retrofit process are required. Among various retrofit methods, the seismic isolation is a very useful method. because it can be applied by replacing old bridge bearings. In this study, the effectiveness of seismic isolation is rationally verified. For this purpose, two seismic isolations used widely are selected and non-linear static and dynamic analyses are performed. The responses of existing bridges are compared with those of retrofited bridges by seismic isolation bridge for earthquake of target level. and seismic performances are evaluated.

Seismic Performance of Composite Beam-to-Column Joints Using Wedges (쐐기의 원리를 이용한 합성 보-기둥 접합부의 내진성능에 관한 연구)

  • Park, Jong-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.6
    • /
    • pp.63-68
    • /
    • 2007
  • The purpose of this study was to develop a new connection method between steel beams and PC columns known as SL connectors. Composite moment frames consisting of PC columns (or composite columns) and steel beams make the best use of advantages of both concrete and steel materials. However, the connection between two members of different materials can be complex and/or increase the fabrication costs significantly. The concept of SL connectors is based on using wedges and the emphasis is on a self-locking (SL) feature. SL connectors are easy to install and provide better seismic performance compared to conventional connections. To evaluate the seismic performance of the steel beam-to-PC column joints with SL connectors, cyclic load tests were conducted. Test result showed that steel beam-to-concrete column joint with SL connectors was able to provide sufficient performance for use in seismic resistant moment frames.

신자재: 방진 및 내진용 배관 고정장치 개발 - 주헌건설(주)

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.247
    • /
    • pp.58-59
    • /
    • 2011
  • 주헌건설(주)은 지난해 6월 자체 개발한 내진 스프링가대가 특허(제10-0962993호)를 획득함에 따라 본격생산에 들어갔다. 내진 스프링가대는 펌프 등 실비기기의 자체진동을 방지하고 지진 발생시 충격을 흡수해 산재사고 예방 및 내진 안전성을 확보하는 장치이다. 이 제품은 지난 2010년 10월 "제4차 UN 재해위험 경감을 위한 아시아 각료회의"의 부대행사로 열린 재해경감 방재산업전에 출품해 호평을 받았다. 또한 배관의 신축 팽창을 자체 흡수하고 각종 슈 대신 절연 유볼트로 시공하므로 원가절감 효과가 있으며 타 공정과의 간섭 없이 시공할 수 있는 장점이 있다.

  • PDF

A Study on Seismic Protection Equipment for Fire Pipes Installed on Buildings (건축물에 설치되는 소방용 배관의 내진장치에 관한 연구)

  • Lim, Geon-Tae;Lim, Sang-Ho
    • Industry Promotion Research
    • /
    • v.4 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • This study is a technology related to a seismic protection device for a fire pipe for installation in a building such as an apartment or a building. The fire pipe is fixed to the base panel by fastening bolts so as to flow left and right. The present invention relates to an earthquake-resistant apparatus for a fire-extinguishing piping, which is capable of minimizing damages caused by an earthquake in order to prevent damages and breakage of a fire-extinguishing pipe by mitigating earthquakes, vibrations, It is connected to an insert plate embedded in concrete or ceiling hanger bolts formed at regular intervals on the ceiling to keep the piping constant from the ceiling and to keep the horizontal condition of the piping always constant so that the piping relaxes or sags And to effectively prevent damage to the piping. The can get.

Collapse Capacity Evaluation of Steel Intermediate Moment Frames Using Incremental Dynamic Analysis (비선형 증분동적해석을 통한 철골 중간모멘트 골조의 붕괴성능 평가)

  • Shin, Dong-Hyeon;Kim, Hyung-Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.9-20
    • /
    • 2014
  • Steel intermediate moment frames (IMFs) have been generally used as seismic load resisting systems (SLRSs) of a building to provide resistances against strong ground shaking. However, most of low and mid-rise steel buildings in Korea were constructed during pre-seismic code era or before the introduction of well-organized current seismic codes. It has been recognized that the seismic performance of these steel IMFs is still questionable. In order to respond to such a question, this study quantitatively investigates the seismic capacities of steel IMFs. Prototype models are built according to the number of stories, the levels of elastic seismic design base shear and the ductilities of structural components. Also, the other prototype models employing hysteretic energy dissipating devices (HEDDs) are considered. The collapse mechanism and the seismic performance of the prototype models are then described based on the results obtained from nonlinear-static and incremental-dynamic analyses. The seismic performance of the prototype models is assessed from collapse margin ratio (CMR) and collapse probability. From the assessment, the prototype model representing new steel IMFs has enough seismic capacities while, the prototype models representing existing steel IMFs provide higher collapse probabilities. From the analytic results of the prototype models retrofitted with HEDDs, the HEDDs enhance the seismic performance and collapse capacity of the existing steel IMFs. This is due to the energy dissipating capacity of the HEDDs and the redistribution of plastic hinges.

Evaluation of Seismic Performance of Steel Frame before and after Application of Seismic Isolator (면진 장치 적용 전, 후의 철골조의 내진 성능 평가)

  • 김대곤;이상훈;안재현;박칠림
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.1
    • /
    • pp.47-62
    • /
    • 1998
  • The laminated elastomeric bearing and the lead-rubber bearing were designed to isolate one bay-two story steel frame which is designed for only gravity load. The seismic performance is evaluated for the designed steel frame before and after application of these seismic isolators between the super structure and the foundation. These isolators can improve the seismic capacity of the steel frame. Especially, by inserting the lead plug into the center of the laminated elastomeric bearing, the initial stiffness of th bearing can be increased, thus rather large lateral displacement can be prevented under the frequent service lateral load. During the strong earthquake, yielding of the lead can increase the capacity of the energy dissipation.

  • PDF

Experimental Study of Friction Pendulum System to Improve the Seismic Capacity of Transformer (변압기의 내진성능 향상을 위한 마찰진자 면진장치의 시험 연구)

  • Jang, Jung-Bum;Kim, Jeong-Ki;Hwang, Kyeong-Min;Ham, Kyung-Won;Park, Jin-Wan;Lee, Chan-Wook
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.1-8
    • /
    • 2008
  • Friction pendulum system is developed to prevent the damage of transformer, which is the most important among the electric power facilities, due to the earthquake and its seismic capacity is verified through the shaking table test. The applicability of friction pendulum system is confirmed as test results of compressive capacity test and friction test. Especially, as a result of shaking table test with a large scale transformer model, friction pendulum system gives to the reduction of maximum response acceleration by 30% at anchorage of transformer and 59% at the top of porcelain bushing comparing with the existing anchorage type. In addition to the reduction of maximum response acceleration, natural frequency of transformer is shifted to long period due to the friction pendulum system. In case that friction pendulum system is applied to the transformer, the damage of transformer can be prevented effectively under the earthquake.