• Title/Summary/Keyword: 내진구조

Search Result 1,421, Processing Time 0.024 seconds

Seismic Performance Evaluation of Masonry Walls Retrofitted with Semi-buried Lattice Reinforcement (조적식 구조물의 부분 매입식 격자철근 보강기법의 내진 성능 평가)

  • Kim, Sang Hyo;Choi, Moon Seock;Park, Se Jun;Ahn, Jin Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.3
    • /
    • pp.88-98
    • /
    • 2011
  • Masonry structure is a style of building which has been widely applied as residential facilities of low and middle stories, commercial and public facilities etc. But it is possible to destroy by loss of adhesive strength or sliding when lateral forces, such as earthquake, occurs. This study proposes a seismic retrofit method for masonry structure and its seismic performance is demonstrated by shaking table test. Two specimens per each shaking direction were made, having out-of-plane(weak axis) and in-plane(strong axis) direction. External load of 1 ton was also applied for each specimen during the test, to model the behavior of reinforced masonry wall. As a result of shaking table tests, it is shown that the specimen applying the proposed seismic retrofit method showed acceptable behaviors in both of Korea building design criteria(0.14g) and USA seismic criteria suggested by IBC(0.4g). However, it was observed that stiffness of the specimen toward out-of-plane was rapidly decreasing when seismic excitations over 0.14g were loaded. In comparison of relative displacements, maximum relative displacement of specimens which were accelerated toward out-of-plane with 0.4g at once was 29~31% of maximum relative displacement when specimens were gradually accelerated from 0.08g to 0.4g, while the maximum relative displacement of specimens accelerated toward in-plane has similar value in both cases. Therefore, it is concluded that the wall accelerated toward out-of-plane is more affected by hair crack or possible fatigues caused by seismic excitation.

우리나라에서의 PC 구조물의 내진 성능 실험

  • Jung, Ran;Kim, Woo;Jung, Ha-Sun;Lee, Han-Sun
    • Computational Structural Engineering
    • /
    • v.3 no.3
    • /
    • pp.30-38
    • /
    • 1990
  • 본 실험은 지금까지 우리나라에서 수행 되어온 기존, 건축 토목관계 실험의 수준을 한차원 높히는데 크게 기여하리라 생각된다. Hydraulic Jack을ㄹ 이용한 1 방향 실험과는 비교할 수 없을 정도로 자동화, 기계화를 이루었으며, 실험에 사용된 Actuator는 미국의 MTS사 제품으로 빠른 속도 (2Hz에서 최대 +/-7.5cm Stroke)로 움직이는 반복 주기 하중을 컴퓨터가 제어하고 Data를 자동적으로 컴퓨터에 기록하므로 구조물의 동적특성까지를 규명하는데 필수적인 장비이다. 또한 Shaking table은 실제로 발생하는 지진파를 그대로 입력시켜 구조물에 대한 내진 성능을 완벽하게 측정할 수 있다. 특히 구조설계자들 사이에도 논란이 되고 있는 우리나라 내진규준의 R factor(반응수정계수)를 정하는데 매우 유효한 역할을 하리라 기대된다.

  • PDF

Improved Distribution of Seismic Forces for Evaluation of Nonlinear Seismic Response of Building Structures (건축구조물의 비선형 지진응답 평가를 위한 개선된 지진하중 분배방법)

  • 이동근;최원호;안지희
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.33-47
    • /
    • 2001
  • 성능에 기초한 내진설계에서는 구조물이 보유하고 있는 능력을 효과적으로 파악하기 위해서 비선형 정적 해석이 적용되고 있다. 그러나 비선형 정적해석은 고차모드에 대한 효과를 고려하지 못함으로써 고층구조물이나 비정형 구조물과 같은 경우에는 정확한 비선형 지진응답의 산정과 내진성능을 평가하는데 문제점을 가지고 있다. 본 연구에서는 건축구조물의 선형 및 비선형 지진응답 평가를 위하여 응답 스펙트럼해석을 통하여 얻어지는 층전단력으로부터 층하중을 산정하는 유사동적해석법이 적용되었다. 제안된 방법을 비선형 정적 해석에 적용하여 구조물의 비선형 자동응답을 비선형 시간이력해석의 결과와 비교하였다. 기존의 층분포하중에 의한 비선형 지진응답과 비교하였으며, 제안된 방법에 의한 지진 응답이 구조물의 비선형 거동특성을 가장 정확하게 표현하였다. 그러므로 본 연구에서 제안된 방법을 사용하여 비선형 정적 해석을 수행한다면 비교적 명확한 건축물의 비선형 거동특성과 내진성능을 평가할 수 있을 것으로 판단된다.

  • PDF

Use of Shakedown Analysis Technique in Optimum Seismic Design of Moment-Resisting Steel Structures (모멘트 - 저항 철골구조물의 최적내진설계에 있어서의 Shakedown 해석기법의 응용)

  • 이한선
    • Computational Structural Engineering
    • /
    • v.2 no.4
    • /
    • pp.99-109
    • /
    • 1989
  • Through a series of analyses of specific structures it is shown that incremental collapse may be the critical design criterion and that shakedown analysis can be used as a design tool. Using shakedown analysis technique, a nonlinear structural optimization program has been developed. This incorporates: (i) design constraints on elastic stresses and deflections: (ii) constraints for the prevention of incremental collapse and soft story failure: and (iii) the constraint on the fundamental period of structure. A five-step design procedure is proposed by using the program to obtain the optimum design that satisfies all the requirements of comprehensive earthquake-resistant design.

  • PDF

Accuracy Improvement of Simplified Liquid Storage Tanks Seismic Design (유체저장탱크 단순화 모델의 정확도 향상을 위한 내진설계변수 산출)

  • Song, Soo-Young;Lee, Kang-Won;Kim, Jun-Hwi;Lim, Yun-Mook
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.285-288
    • /
    • 2010
  • 유체저장탱크가 외부로부터 지진과 같은 동적하중을 받게 될 경우 유체와 구조물의 상호작용(Fluid-Structure Interaction)으로 인하여 일반적인 구조물과는 상이한 거동을 보이게 된다. 이러한 복잡한 상호작용을 고려하여 현재 내진 설계에서는 Housner와 Haroun의 이론을 적용한 단순화 모델들이 사용되고 있다. 이들 모델은 유체의 거동을 대류(convective) 성분과 충격(impulsive) 성분으로 구분하여 집중질량으로 단순화 한다. 하지만 점차 대형화되고 있는 유체저장탱크의 정확한 동적 거동 특성을 파악하고, 지진하중과 같은 방향성을 가진 하중에 대한 구조물의 정확한 응답을 해석하려면 단순화 모델의 적용성 검토가 필요하다. 본 연구에서는 지진하중을 받는 유체저장탱크의 동적거동을 집중질량 모델과 3차원 모델을 이용하여 해석하였다. 나아가 해석결과의 차이를 분석하여 단순화 모델의 정확도 향상을 위한 내진설계변수 산출에 관하여 향후 연구방향을 제시하였다.

  • PDF

A Study of Site-Specific Design ground Motions in Earthquake-Resistant Design for Geotechnical Structures (지반구조물 내진설계시 부지특성을 고려한 설계 지반운동연구)

  • 권수영;박인준
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.2
    • /
    • pp.37-46
    • /
    • 2000
  • 본 논문에서는 부지특성을 고려한 설계지반운동의 산정방법을 연구하였으며 그 해석결과를 지반 구조물의 내진설계에 적용하는 방법을 제안하였다 지진응답 해석시 사용되는 설계응답스펙트럼과 설계시간 이력등의 입력운동의 통제점 위치가 지반구조물 내진설동 지층내 암반운동 그리고 노두운동을 사용하는 방법으로 나눌 수 있고 이에 따라 작용 설계지진운동이 변화하므로 지반구조물의 경계조건에 적합한 방법을 사용하여야 한다.

  • PDF

Centrifuge-Shaking Table Test for Seismic Performance Evaluation of Subway Station (지하역사의 내진성능평가를 위한 원심모형 진동대 시험)

  • Kim, Jin Ho;Shin, Min Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.3
    • /
    • pp.99-105
    • /
    • 2011
  • When a certain magnitude earthquake occurs, serious damage for human and properties is a major concern for most of the subway stations which were not applied for earthquake resistant design. Consideration and experimental verification for ground and structural behavior based on soil-structure interaction relation are required to evaluate seismic performance of the subway station as embedded structures. For 1/60 scaled subway station model, centrifuge modeling shaking table test is performed using Kobe and Northridge earthquakes. Compare to displacements and moments of the underground and structure obtained by soil response analysis and response displacement method based on experimental results, this paper shows how to evaluate seismic performance of subway station.