• Title/Summary/Keyword: 내전압

Search Result 74, Processing Time 0.033 seconds

Improvement of the Resistivity in High Field for the New Piezoelectric Compositions in the Bi(NiaX1-a)O3-PbTiO3(X=Ti,Nb) System (Bi(NiaX1-a)O3-PbTiO3 계 압전 신조성(X-Ti,Nb)의 내전압 특성 향상)

  • Choi, Soon-Mok;Seo, Won-Seon
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.4
    • /
    • pp.220-225
    • /
    • 2008
  • Lead-free ferroelectric ceramics are widely researched today for industrial applications as sensors, actuators and transducers. Since $Pb(Zr_aTi_{1-a})O_3$-(PZT) has high Curie temperature($T_C$), high piezoelectric properties near its morphotropic phase boundary(MPB) composition and small temperature dependence electrical behavior, it has been used to commercial materials for wide temperature range and different application fields. According to the tolerance factor concept, since the $Bi^{3+}$ cation with 12-fold coordinate has a smaller ionic radius than 12-fold coordinate $Pb^{2+}$, most bismuth based perovskites possess a smaller tolerance factor. Therefore, MPBs with a higher $T_C$ may be expected in $Bi(Me^{3+})O_3PbTiO_3$ solid solutions. As in lead based perovskite systems, it is clear that we need to explore more materials in simple or complex bismuth based MPB systems. The objective of this study is to investigate the $Bi(Ni_{1_a}X_a)O_3-PbTiO_3(X=Ti^{4+},\;Nb^{5+})$ perovskite solid-solution. For improving the electronic conduction problem, the magnesium and manganese modified system was also studied.

Fabrication of Aluminum Powder Disk by a Template Method and Its Etching Condition for an Electrode of Hybrid Supercapacitor (Template 방법을 이용한 Hybrid Supercapacitor 전극용 알루미늄 분말 디스크 제조와 에칭 조건 연구)

  • Jin, Chang-Soo;Lee, Yong-Sung;Shin, Kyung-Hee;Kim, Jong-Huy;Yoon, Soon-Gil
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.2
    • /
    • pp.145-152
    • /
    • 2003
  • Capacitance of a hybrid capacitor that has characteristics of both electrolyte capacitor and supercapacitor is determined by anode surface covered with oxide layer. In this study, optimal condition processes for anode to fabricate a high voltage hybrid capacitor was investigated. We mixed aluminum powder having mean particle size of $40{\mu}m$ with NaCl powders at weight ratio of 4 : 1 and prepared a disk type electrode after annealing at various temperature. After dissolving NaCl in $50^{\circ}C$ distilled water, heat treatment, eletropolishing, chemical treatment, and the first and the second etching of Al disk were conducted. In each process, capacitances and resistances of the disk measured by ac-impedance analyzer were compared to find its optimum treatment condition. Also, the surface morphology of treated disks were observed and compared by SEM. After the second etching, the Al disk was anodized at 365V to make an anode of hybrid supercapacitor that can be operated at 300V, Capacitance and resistance of the anodized Al disk electrode was compared with those of commercialized conventional aluminum electrolytic capacitor at different frequencies.

Study on Condition of Fabrication Processing for R. F. High-power Unit Capacitor and Electrical Characteristics According to Addition of ZrO2 (고주파용 대용량 단위 유전체 제조공정과 ZrO2 첨가에 따른 전기적 특성 연구)

  • Ahn, Young-Soo;Kim, Joon-Soo;Park, Joo-Seok;Kim, Hong-Soo;Han, Moon-Hee;No, Kwang-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.9
    • /
    • pp.822-828
    • /
    • 2002
  • Fabrication and electrical characterization of R. F. High-power unit capacitors were investigated to study on condition of fabrication processing for R. F. High-power unit capacitor and electrical characteristics according to addition of $ZrO_2$. The unit capacitors were fabricated using tape casting. The optimum mixture ratio of dielectrics and mixing binder for the slurry fabrication was 57.5∼60.0: 42.5∼40.0 wt%. The slurry viscosity was 4000∼5000 cps and casting state of green tape fabricated using these slurry was excellent. Optimum stacking was made by 200 kg/$cm^2$ pressure with 80$^{\circ}C$ heating. $ZrO_2$ was added to improve the electrical characteristics of unit capacitor, especially breakdown characteristics. The dielectric constant and loss factor of the unit condenser having different $ZrO_2$ amounts was not changed in the addition range of 1 to 5 wt%. Also, dielectric constant was not changed in the frequency range of 10 to 500 kHz. It was found that characteristics of resistance voltage was improved through the formation of $CaZrO_3$ and the reduction of particle size as about 3wt% $ZrO_2$ was added.

Overview of MV Cable Diagnostic System for KEPCO (KEPCO의 지중배전케이블 열화진단기술 적용 방향)

  • Kwon, Tae-Joon;Kim, Sung-Min;Kim, Byung-Suk;Lee, Jae-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2093-2094
    • /
    • 2011
  • 가교폴리에틸렌(XLPE) 절연체를 적용한 MV급 지중케이블은 1972년부터 KEPCO에서 본격적으로 사용되기 시작하였다. 이후 도심지 지중화사업에 힘입어 매년 6.5%정도의 케이블 설비가 증가하였으며 오늘날 29,000C-km이상의 MV급 케이블이 설치되어 있다. 과거 비약적인 경제성장과 더불어 전력망 확충을 위한 투자가 KEPCO의 주된 역할이었다면 오늘날에 있어서는 확충된 설비를 최적의 상태로 유지 관리하는 것으로 패러다임이 변하고 있다. 특히 지중설비의 동맥(動脈)으로 볼 수 있는 케이블에 대한 관리방법이 화두가 되고 있으며 최적관리의 전제조건인 열화진단 분야가 KEPCO가 이끌고 나가야 할 새로운 개척분야로써 많은 역량이 집중되고 있다. 2010년에는 VLF TD/PD를 새로운 진단기법으로 적용하였으며 케이블 설치공사 준공 검수시험으로 0.1Hz 저주파 교류내전압시험 도입 및 활선 PD진단장치를 자체 개발하여 현장 적용성 검토를 추진하는 등 MV급 지중설비의 관리기법에 있어 큰 전환점을 만들고 있다. 본 고에서는 KEPCO의 MV급 케이블 변천사와 추진하고 있는 진단기법 및 관리 지향점을 논하고자 한다.

  • PDF

Flashover Voltage of 800kV Class Composite Hollow Insulator for $SF_6$ Gas Insulated Switchgear (GIS) (800kV $SF_6$ 가스절연 개폐장치용 (GIS) 복합절연애자 (Composite Hollow Insulator)의 표면오손시 내전압특성)

  • Lee, C.R.;Yoon, J.H.;Choi, B.H.;Yoon, C.Y.;Ko, K.S.;Ban, S.G.;Huh, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1449-1451
    • /
    • 2002
  • A developed 800kV class composite hollow insulator for $SF_6$ Gas Insulated Switchgear (GIS) was tested as to insulation with their surfaces contaminated. The wet power frequency withstand voltage of the silicone rubber housing was about 135kV at an equivalent salt deposite density of $5kg/m^2$, to sufficiently satisfy the required performance. According to IEC 60507, the salt fog withstand voltage was measured at 565kV, and the highest measured leakage current was below 0.2mA. Therefore, it was clarified that the composite hollow insulator has sufficient insulation performance even when it is contaminated on the surface.

  • PDF

Impulse Tests for a Composite Solid Insulator for High Voltage Superconducting Power Applications (복합고체절연물의 극저온 절연성능 평가를 위한 임펄스 내전압시험)

  • Kim, W.S.;Ryu, S.D.;Hyun, O.B.;Kim, H.R.;Yim, S.W.;Yang, S.E.;Kim, H.S.
    • Progress in Superconductivity
    • /
    • v.13 no.1
    • /
    • pp.24-27
    • /
    • 2011
  • High voltage insulation in cryogenic environment is one of big issues for development of superconducting power application, such as superconducting fault current limiter, transformer, transmission cable, and so on. We had proposed a composite solid insulator composed of plastics and polymer insulation sheets for a use of high voltage superconducting power applications. It is well known that the G10 FRP keeps its mechanical strength at very low temperature and the PPLP is very good insulator adopted as insulations for superconducting transmission cables. The composition of these two materials will show very good electrical and mechanical properties adequate for the insulation components of superconducting power applications, such as bushing, insulation barrier, and even for a cryostat. Dielectric strengths of prepared samples were measured at the temperature of boiling point of liquid nitrogen at atmospheric pressure, which will be presented in this paper to show a usefulness of this technique.

Status of the Factory Acceptance Test for ITER AC/DC Converter Transformers (ITER 초전도자석 전원장치용 변압기의 제작 및 시험 현황)

  • Choi, J.;Suh, J.H.;Oh, J.S.;Shin, H.K.
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.190-191
    • /
    • 2016
  • 국제 핵융합실험로인 ITER 장치의 초전도자석 전원장치용 CCU/L(Correction Coil Upper/Lower), CCS(Correction Coil Side) 그리고 VS1($1^{st}$ Vertical Stabilization) 형식 등 각 변압기 초도품의 제작을 완료하고 공장시험(FAT, Factory Acceptance Test)을 실시하였다. 이 변압기들은 각 형식별로 2대에서 6대를 제작하지만 각 형식별 초도품 1대에 대해서는 Type Test를 실시하고 나머지 후속물량에 대해서는 Routine Test로 공장시험을 실시하도록 계획되어 있다. 따라서 이 초도품 변압기들에 대해서는 Type Test로 공장시험으로 실시하였고, 그 대표적인 시험항목으로는 단락시험, %임피던스 시험, 뇌임펄스 시험, 정격전류 온도상승시험, 상용주파수 내전압시험 등이 있다. 이들 중 CCU/L, CCS 각 형식의 초도품에 대해서는 2015년도 공장시험을 실시하여 요건에 부합됨을 확인하였고, 본 논문에서는 VS1 컨버터 변압기 초도품에 대하여 Type Test로 실시한 공장시험 내용과 그 결과를 보여준다.

  • PDF

Fabrication and Electrical Insulation Property of Thick Film Glass Ceramic Layers on Aluminum Plate for Insulated Metal Substrate (알루미늄 판상에 글라스 세라믹 후막이 코팅된 절연금속기판의 제조 및 절연특성)

  • Lee, Seong Hwan;Kim, Hyo Tae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.4
    • /
    • pp.39-46
    • /
    • 2017
  • This paper presents the fabrication of ceramic insulation layer on metallic heat spreading substrate, i.e. an insulated metal substrate, for planar type heater. Aluminum alloy substrate is preferred as a heat spreading panel due to its high thermal conductivity, machinability and the light weight for the planar type heater which is used at the thermal treatment process of semiconductor device and display component manufacturing. An insulating layer made of ceramic dielectric film that is stable at high temperature has to be coated on the metallic substrate to form a heating element circuit. Two technical issues are raised at the forming of ceramic insulation layer on the metallic substrate; one is delamination and crack between metal and ceramic interface due to their large differences in thermal expansion coefficient, and the other is electrical breakdown due to intrinsic weakness in dielectric or structural defects. In this work, to overcome those problem, selected metal oxide buffer layers were introduced between metal and ceramic layer for mechanical matching, enhancing the adhesion strength, and multi-coating method was applied to improve the film quality and the dielectric breakdown property.

Comparison of Standards for a 1ϕ 2 W MCCB and Study on the Evaluation of Heat Resistance Characteristics (1ϕ 2 W MCCB의 기준 비교 및 내열 특성 평가에 관한 연구)

  • Choi, Chung-Seog;Lee, Jae-Hyuk
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.21-28
    • /
    • 2014
  • This study obtained the following results by analyzing the standards related to a $1{\phi}$ 2W MCCB and evaluating its heat resistance characteristics. Since KS C 8321 corresponds to IEC 60947-2 standards, most of the related regulations are similar. The NFPA, which presents the user oriented safety regulations, contains no details about tests or inspections, etc., but it does specify in detail the regulations directly related to safety. It can be seen that KS C 8321 classifies in detail the items about tests and inspections. However, IEC 60947-2 and IEEE C37.51 simplified the test and inspection items or omitted some of them. When applying thermal stress to an MCCB for 6 hours at $180^{\circ}C$ using a heat resistant experimental device, it was found that the actuator lever was transformed and moved in the tripped state. In addition, most of the fixing hanger was melted down, losing their function. When applying thermal stress to the MCCB at $90^{\circ}C$, it showed nothing peculiar, but the fixing hanger was partly deformed at $105^{\circ}C$ and $120^{\circ}C$. It was found that the fixing hanger was deformed and the name plate was discolored at $150^{\circ}C$. It can be seen from the analysis of the internals of the MCCB that the trip bar has been melted away and that the up and down operator has moved up. The experiment performed by applying a withstanding voltage of 6 kV for 60 s showed that all items remained intact. In addition, the evaluation of the insulation performance performed by applying DC 500 V using an insulation-resistance tester showed good insulation performance.

A Study on the Properties Analysis of an Iron Fittings Type CSST Damaged by the PCITS (PCITS에 의해 소손된 강이음쇠형 CSST의 특성 해석에 관한 연구)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.121-127
    • /
    • 2016
  • This study analyzed the structural and electrical characteristics of an iron fittings type Corrugated Stainless Steel Tubing (CSST) damaged by the Primary Current Injection Test System (PCITS). CSST consists of cladding, tube, nuts, clamp ring, flare cap, socket, and ball valve. For an evaluation of the dielectric withstand voltage, the area between the live part and non-live part of the CCST shall withstand a voltage of 220 V AC for one minute. For an evaluation of the insulation performance by 500 V DC, it is required that the insulation exceed more than $1M{\Omega}$ before the temperature rise test, $0.3M{\Omega}$ after the test. Although the average resistance of the product was $11.5m{\Omega}$, that of the product damaged at a current of 130 A by the PCITS was $11.50m{\Omega}$. Furthermore, parts of the cladding were melted and black smoke appeared when a current of 130 A applied for 10 s. After 60 s, most parts were heated and turned red. At 120 s, the parts that turned red had widened. Although it did not form a normal distribution because the P value was 0.019 with a confidential interval of 95%, it revealed outstanding characteristics with an AD (Anderson-Darling) value of 0.896 and a standard deviation of 0.5573.