• 제목/요약/키워드: 내부 팬

Search Result 114, Processing Time 0.024 seconds

An experimental study on the smoke-spread region before reaching the critical velocity for the case of fires in tunnels employing longitudinal ventilation system (종류식 환기 시스템에서 임계속도 도달 전 스모크 확산 영역에 관한 실험적 연구)

  • Ki, Young-Min;Yoon, Sung-Wook;Yoon, Chan-Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.16 no.6 s.65
    • /
    • pp.526-535
    • /
    • 2006
  • An experimental study was carried out on a reduced scale tunnel model to grasp the behavioral feature of fire-induced smoke in the long tunnels. Based on Froude modeling, the 1/50 scaled tunnel model (20 m long) was constructed by acrylic tubes and paraffin gas was released inside the tunnel to simulate the 20 MW fire-induced smoke. me test results show, that after approximately 2 minutes of fire generation, was descended from the tunnel ceiling through the decrease of buoyancy, then it was symmetrically propagated about 90 meters for 4 minutes before jet fans were operated. The smoke was effectively controlled when the jet fans were operated and an air stream velocity was getting closed to reach a critical velocity (the minimum air velocity that requires to suppress the smoke spreading against the longitudinal ventilation flow during the tunnel fire situations). It was also found out that a range of smoke was spreaded about 3 meters from the origin of fire but the range was not propagated to the escape direction anymore. The early stage of the In operation, however, showed that the smoke was hardly controlled. It means that the operation of emergency ventilation system has many dangerous factors such as an intercepting breathing zone.

Uniformity of Temperature in Cold Storage Using CFD Simulation (CFD 시뮬레이션을 이용한 농산물 저온저장고내의 온도분포 균일화 연구)

  • Jeong, Hoon;Kwon, Jin-Kyung;Yun, Hong-Sun;Lee, Won-Ok;Kim, Young-Keun;Lee, Hyun-Dong
    • Food Science and Preservation
    • /
    • v.17 no.1
    • /
    • pp.16-22
    • /
    • 2010
  • To maintain the storage quality of agricultural products, temperature uniformity during cold storage, which is affected by fan flow rate and product arrangement, is important. We simulated and validated a CFD (Computational Fluid Dynamics) model that can predict both airflow and temperature distribution in a cold storage environment. Computations were based on a commercial code (FLUENT 6.2) and two turbulence models. The standard k-$\varepsilon$ model and the Reynolds stress model (RSM) were chosen to improve the accuracy of CFD prediction. To obtain comparative data, the temperature distribution and velocity vector profiles were measured in a full-scale cold storage facility and in a 1/5 scale model. The agricultural products domain in cold storage was modeled as porous for economical computation. The RSM prediction showed good agreement with experimental data. In addition, temperature distribution was simulated in the cold storage rooms to estimate the uniformity of temperature distribution using the validated model.

Computer Simulation for Developing the Plate and Corner Type In-Situ Thermal Resistance Measuring Device (평판 및 모서리형 현장열저항 측정기기 개발을 위한 Computer Simulation)

  • Kang, Byeong-Woong;Park, Seung-Ik;Yu, Seung-Sun;Park, Hyo-Soon
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.71-80
    • /
    • 1999
  • For developing a new measuring device which enables the thermal resistance at comers of the building envelope in addition to the plate wall measuring device, computer simulations were performed to clarify the problems produced during previous tests. For the optimum design to reduce the temperature deviation in measuring device, the specifications of the measuring devices are to be as follows : Dimension of the device is $500{\times}500{\times}100mm$ in size, heating plate is seperated to some degree from the inner surface of the measuring device, lower temperature of heating plate is as effective as possible, fans should be located at the upper part in the measuring device and face to downward.

  • PDF

Numerical Analysis on development of the Cooling System for E-Scooter Battery Pack (전동스쿠터용 배터리팩 냉각시스템 개발을 위한 수치해석)

  • Lee, Suk Young
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.30-36
    • /
    • 2016
  • The battery pack which is a main component of E-scooter needs the cooling system because it is the matter of battery safety in spite of the incresing of charge efficiency due to decress the internal resistence in the condition of high temperature. The purpose of this study is to analyse the effects of cooling methods which is the control of air's inlet and outlet operating timing. When each battery had large temperature deviation in the battery pack, the difference of battery's performance and efficiency were appeared. In this study, the cooling performance of battery pack has been improved by changing the operation timing of inlet and outlet fan, it improved the performance and efficiency of battery. The numerical analysis using a commercial code ANSYS CFX version 17.0 were used for the study.

Technology for Improving the Uniformity of the Environment in the Oyster Mushroom Cultivation House by using Multi-layered Shelves (느타리버섯 균상재배사의 환경균일성 향상을 위한 기술 개발)

  • Lee, Sunghyoun;Yu, Byeongkee;Kim, Hyuckjoo;Yun, Namkyu;Jung, Jongcheon
    • Journal of Bio-Environment Control
    • /
    • v.24 no.2
    • /
    • pp.128-133
    • /
    • 2015
  • Mushrooms can grow in nature when adequate temperature and humidity are maintained, but such condition can be satisfied for only a short period of time on an annual continuum. Therefore, it can be deemed that a majority of the distributed mushrooms in the current market are produced in an artificially manipulated environment. This study was conducted to resolve the problem of the Oyster mushroom cultivation house's internal temperature and humidity imbalance, where the Oyster mushrooms are cultivated in a multi-layered shelves. The air circulation fans were installed to improve the air uniformity of the Oyster mushroom cultivation house by using multi-layered shelves. During the experiment, the ambient temperature and the ambient relative humidity ranged from $5.2^{\circ}C$ to $20.4^{\circ}C$ and 40% to 100% respectively. Due to the change of the outdoor temperature, the internal temperature of the Oyster mushroom cultivation house also changed, ranging from $13.3^{\circ}C$ to $18.4^{\circ}C$, but the temperature gap between the different internal location of the facility during the conforming recorded time only ranged from $0.2^{\circ}C$ to $1.3^{\circ}C$, being significantly stable. The internal relative humidity, ranging from 82% to 96%, also changed due to the change of the outdoor temperature. Nevertheless, the relative humidity gap between the different internal location during the conforming recorded time only ranged from 2% to 7%. Furthermore, the research staff were able to maintain the concentration of $CO_2$ from 575ppm to 731ppm(below 1,000ppm was the goal) indicating the possibility of an even management of the internal environment by installing the air circulation fan.

STRUCTURAL SAFTY EVALUATION OF COMPRESSOR DRIVING MOTOR SHAFT SYSTEM (컴프레서 구동용 전동기 축계의 구조 안전성 평가)

  • Jung, Kun-Hwa;Kwak, Ju-Ho;Kim, Byung-Joo;Lee, Jong-Moon
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1031-1036
    • /
    • 2007
  • Torsional vibration analysis is necessary at design stage to ensure the reliability of a system particularly when the driven machine is a reciprocating compressor. This paper contains the results of torsional vibration analysis and fatigue strength evaluation for 540 kW compressor driving motor. Torsional vibration analysis showed that the $2^{nd}$ torsional mode of the entire shaft system has the possibility of resonance with the $14^{th}$ order excitation of compressor and twin line frequency of motor at operating speed. Therefore, the analyses were required to ensure the structural reliability of the motor. The fatigue strength was evaluated for the shaft and inner fans using the results of forced vibration analysis. It is concluded that the motor has sufficient fatigue strength under normal operating condition.

  • PDF

Charactericstics of Heat Flow in a Machine Room of Refrigerator(II) (냉장고 기계실 내부 열 유동 특성 해석(II))

  • 한병윤;김재열;김태훈;김영국;이연원
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.173-179
    • /
    • 2002
  • There is a growing concert about energy efficiency at the present time. Even refrigerators can not be omitted from this issue. So the factors have been searched to decrease the consumption of electric power in refrigerators. It is possible to analyze the numerical data of the cover back machine and the change of condenser shape to find that they affect the consumption of electric powers by improving the fluid flow of within the interior of the refrigerator. As a result, the problems, fluid of the eddy and stationary of the existing refrigerator can be solved partly by the improved model.

  • PDF

Technological Advances for Particulate Matter Collection in Subway System (지하철 미세먼지 포집을 위한 기술적 진보)

  • Son, Youn-Suk;Ryu, Jae-Yong
    • Prospectives of Industrial Chemistry
    • /
    • v.21 no.2
    • /
    • pp.24-34
    • /
    • 2018
  • 본 연구에서는 지하역사 및 터널에서 발생되는 미세먼지의 현황 및 이를 저감하기 위한 기술의 동향을 조사하였다. 지하역사 및 터널의 미세먼지 농도는 주변 대기 중의 농도보다 높은 것으로 나타났다. 그 구성 성분에 있어서 다양한 중금속 및 발암물질들을 함유하고 있고, Fe의 농도가 가장 높게 나는 것을 알 수 있었다. 지하역사 및 터널의 미세먼지 농도는 주변 대기 농도와 같은 외부 요인뿐만 아니라 열차의 운행 수, 이용 승객수, 환기량과 같은 내부 요인도 큰 영향을 미치는 것을 확인할 수 있었다. 현재 지하역사 및 터널의 미세먼지를 저감하기 위해서 다양한 기술(환기팬, 스크린도어, 자성필터, 소형제트팬, 인공지능 환기시스템 등)들이 연구되고 있으며, 그 기술들은 현장 조건에 맞추어 사용되어야 그 실효성을 극대화시킬 수 있을 것이다.

Actual State of Practical Use and Cooling Effect of Evaporative Cooling Systems (증발냉각시스템의 활용실태 및 냉방효과)

  • 김문기;유인호;김기성
    • Journal of Bio-Environment Control
    • /
    • v.8 no.4
    • /
    • pp.281-287
    • /
    • 1999
  • In order to take a good look at effectiveness of cooling of Fog system and Pad-Fan system, we chose 49 farm households which were installed evaporative cooling system and 2 farm households which were installed Pad-Fan system and Fog system for a test. We execute the test on 29 households out of 49.6 households, which were installed Pad-Fan system, were able to use; however, 6 household out of 9 which were installed Fog system couldn't use it. The main reason was the clogged on nozzle. The cooling efficiency on Pad-Fan system was 77.4%, but it was very poor on Fog system. Since there are many problems on Fog system, we need more research on size of fog, the location of nozzle, control of Fog systems.

  • PDF

An Investigation on Influence of Vibration Noise in Cooling Tower on Precision Equipments (산업용 냉각탑의 진동소음이 정밀장비에 미치는 영향에 대한 연구)

  • Lee, Jin-Kab
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.369-374
    • /
    • 2016
  • Cooling towers have been installed on rooftops or outside of buildings and widely applied to control the indoor temperature in residential areas and buildings. However, the noise and vibration resulting from their operation may cause problems in adjacent buildings. The purpose of this study is to measure the noise and vibration of an industrial cooling tower located adjacent to industrial plants and to investigate its influence on the surroundings according to an authorized evaluation standard. Further, in order to measure the effect of the vibration of the tower on the precision equipment inside the plant, an experiment is conducted to measure the vibration of the ground in the plant and the targeted precision equipment. The measurement results indicate that the noise in the cooling tower is 4 to 9 dB(A) higher than the maximum level defined in the standard of 68dB(A). The effect of the vibration of the tower on the precision equipment is comparatively minimal, because that in the supporting frame of the building is weaker than that on the floor where the precision equipment is located. The vibration of the floor on.