• Title/Summary/Keyword: 내부 유로

Search Result 723, Processing Time 0.024 seconds

Effect of Diffuser Locations on the Room Acoustical Parameters in 1:25 Scale Model Hall (1:25 축소모형 홀에서 확산체의 설치부위에 따른 실내 음향지표의 변화)

  • Kim, Yong-Hee;Seo, Choon-Ki;Lee, Hye-Mi;Jeon, Jin-Yong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.115-128
    • /
    • 2012
  • This paper investigates the effects of diffuser on the acoustical parameters in music hall with consideration of the result of scattering coefficient measurement. A scale model hall of 600 seats with orchestra shell was used for experiments. The materials of 1:50 scale model was chosen through absorption coefficient measurement based on ISO 354. The model was matched to the computer simulation model in terms of reverberation time. In order to evaluate the effect of diffuser location, the measurements were accomplished with and without diffusers according to 7 configurations by diffuser-installed region; sidewall, balcony front, ceiling and so on. The following acoustical parameters were extracted from each measurement case; Reverberation time (RT), Early decay time (EDT), Clarity (C80), Center time (Ts), Sound strength (G) and Temporal diffusion (TD) from the auto-correlation function (ACF) of impulse responses. As a result, the absorption power and diffusion power were increased with number of diffusers. Accordingly RT, EDT and G were decreased by diffuser and the redirection of reflections was occurred briskly. Averaged TD was 6.05 to 6.30 by measurement cases. RT was found to be the most related factor to diffusion power (R = 0.94). The correlation between TD and EDT was high (R = 0.73). In addition, the effects of diffuser-installed location were discussed in terms of acoustical parameter variation.

A Study on Greenhouse Gas Emissions Estimation based on Mileage Through Accumulation of Activity Databases (활동자료 구축을 통한 주행거리 기반의 온실가스 배출량산정방법에 관한 연구)

  • Bae, Bo Ram;Kim, Gyeong Seok
    • Journal of Korean Society of Transportation
    • /
    • v.32 no.1
    • /
    • pp.1-12
    • /
    • 2014
  • The tier 3 methodology used in estimation of greenhouse gas emissions from road sectors is based on mileage data. However, such data can neither accurately represent the mileage of regional unit nor have sufficient integrated data reflecting the characteristics by region, vehicle type, fuel type and road type. Such estimation of greenhouse gas emissions is not reliable. Accordingly, the purpose of this study is, firstly to accumulate activity data based on distance traveled which enables us to accurately estimate the amount of green gas emitted by regional unit(emission point), and secondly, to develop a methodology for estimation of greenhouse gas emissions using these data. To do this, the study utilizes the mileage data of Korea Transportation Safety Authority(TS), statistics of registered motor vehicles, statistical yearbook of traffic volume from the Ministry of Land, Infrastructure and Transport(MLIT), the Korea Transport Database of the Korea Transport Institute(KOTI), and average road speed by local government. Methodology for estimation by local government level(emission point) is meaningful, because it reflects traffic pattern data including flow in and out and internal traffics. Finally, to verify the methodology presented in this study, it is applied to Seoul. Both greenhouse gas estimates, one by multiplying the average mileage and the number of registered vehicles and the other by multiplying traffic volume and road extension, are less than the amount estimated by the methodology presented in this study.

Change Monitoring in Ecological Restoration Area of Open-Pit Mine Using Drone Photogrammetry (드론사진측량을 이용한 노천광산 생태복원지역의 변화 모니터링)

  • Lee, Dong Gook;Yu, Young Geol;Ru, Ji Ho;Lee, Hyun Jik
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.4
    • /
    • pp.97-104
    • /
    • 2016
  • In this study, analyze and monitor the change of the ecological restoration area inside the open-pit mine in Gangwon-do. and to analyze and monitor the change of ecological restoration area. analyzed the distribution of vegetation using high-resolution orthophoto of various periods and analyzed terrain change using DSM/DEM in study area. Therefore, orthophoto and 포인트 클라우드 were collected from 2014 aerial laser surveying and 2015 fixed-wing drone photogrammetry. In addition, orhtophoto and 포인트 클라우드 were produced by using rotary-wing drone photogrammety in 2016, and change of ecological restoration area was analyzed using this. As a result, it's possible to perform change monitoring of the open-pit mine ecological restoration area. using nEGI and VARI, about 10-30% of the area ratio of the result of extracting vegetation distribution area is distributed, and the comparison DSM and DEM cross section and restoration plan line, the cross section made by using the drone were similar, and the earth-volume analysis was possible.

Cold Test and Internal Flow Analysis of Semi-Freejet Type High Altitude Environment Simulation Test Facility for the High-Speed Vehicle (초고속 비행체를 위한 준 자유흐름식 고공환경 모사시험설비의 상온시험 및 내부유동 해석)

  • Lee, Seongmin;Yu, Isang;Choi, Jiseon;Oh, Junghwa;Shin, Minkyu;Ko, Youngsung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.4
    • /
    • pp.290-296
    • /
    • 2018
  • In this study, the cold test and the numerical analysis were carried out according to the shape parameters of the test model in order to confirm the operation range of high altitude environment simulation test facility for the supersonic vehicle. The blockage ratio, angle and length ratio were considered as the design parameters. The blockage rate is expected to be limited in the region of more than 40% due to the normal shock and expansion fan. It was confirmed that the angle of model should be selected at the size of 45 degrees or less due to the influence of the strong shock wave. There was no difference in performance between the lengths of 8 times the model diameter. Finally, we obtained the performance database according to the shape parameters of the conical test model and confirmed the operable range of the semi-freejet type high altitude environment simulation test facility.

Life Prediction for High Pressure Hose of Power Steering System by Impulse Pressure Test (충격 압력을 받는 파워스티어링 시스템의 고압호스 수명 예측)

  • Lee, Gi-Chun;Kim, Hyoung-Eui;Park, Jong-Won;Lee, Jong-Hwang;Jeong, Won-Wook;Im, Young-Han;Hwang, Kwon-Tae;Lee, Young-Shin;Kim, Jae-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.1
    • /
    • pp.91-96
    • /
    • 2010
  • The hydraulic hose can be divided with the low pressure, the medium pressure, and the high pressure hose according to the applied pressure. The power steering system in a passenger car can be divided with the high pressure and the low pressure hose. This study deals with the life prediction for high pressure hose to be given impulse pressure which was generated in turning the car. To adjust with external and internal condition, impulse pressure and oil temperature need to be controlled with impulse test system. The result, which is only controlled with the pressure and oil temperature, adapted Calibrated Accelerated Life Test(CALT) method to predict the life of the high pressure hose and analyzed the swagging part by finite element method during the impulse test.

Computational Fluid Dynamics Model for Solar Thermal Storage Tanks with Helical Jacket Heater and Upper Spiral Coil Heater (상부 코일히터를 갖춘 나선재킷형 태양열 축열조의 성능예측을 위한 CFD 해석모델 개발 및 검증)

  • Baek, Seung Man;Zhong, Yiming;Nam, Jin Hyun;Chung, Jae Dong;Hong, Hiki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.331-341
    • /
    • 2013
  • In a solar domestic hot water (SDHW) system, solar energy is collected using collector panels, transferred to a circulating heat transfer fluid (brine), and eventually stored in a thermal storage tank (TST) as hot water. In this study, a computational fluid dynamics (CFD) model was developed to predict the solar thermal energy storage in a hybrid-type TST equipped with a helical jacket heater (mantle heat exchanger) and an immersed spiral coil heater. The helical jacket heater, which is the brine flow path attached to the side wall of a TST, has advantages including simple system design, low brine flow rate, and enhanced thermal stratification. In addition, the spiral coil heater further enhances the thermal performance and thermal stratification of the TST. The developed model was validated by the good agreement between the CFD results and the experimental results performed with the hybrid-type TST in SDHW settings.

Analysis of Waterborne Automotive Refinish Paint for Investigating Insurance Fraud (차량 보수도장 보험사기 규명을 위한 수용성 페인트 성분분석)

  • Lee, Joon-Bae;Lee, Cheon-Ho;Ryu, Seung-Jin;Gong, Bokyoung;Kwon, O-Seong;Kim, Myung-Duck;Kim, Nam Yee;Paeng, Ki Jung
    • Applied Chemistry for Engineering
    • /
    • v.28 no.4
    • /
    • pp.490-494
    • /
    • 2017
  • With increasing the number of vehicles, the accident rate also goes up and the damaged vehicles should be painted as a final repair process. At the painting stage the solvent-based paint causes environmental problems. To overcome these problems waterborne refinish paint is frequently used recently. However, for waterborne refinish, the costs of insurance coverage are too expensive, and insurance reimbursement costs could be burdensome. Because of the high price of aquatic paint treatment, the service shop might charge the malicious service price. In this study, the surfactant of Surfynol 104, which is the component in the paint, was used as an indicator whether the vehicle was painted with waterborne paint. The specimen was quantitatively analyzed to contain 0.38% of the surfactant through the standard addition method with isotope substituted internal standard (IS) of fluranthene-d10 by curie point pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS).

Automatic Change Detection Based on Areal Feature Matching in Different Network Data-sets (이종의 도로망 데이터 셋에서 면 객체 매칭 기반 변화탐지)

  • Kim, Jiyoung;Huh, Yong;Yu, Kiyun;Kim, Jung Ok
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.6_1
    • /
    • pp.483-491
    • /
    • 2013
  • By a development of car navigation systems and mobile or positioning technology, it increases interest in location based services, especially pedestrian navigation systems. Updating of digital maps is important because digital maps are mass data and required to short updating cycle. In this paper, we proposed change detection for different network data-sets based on areal feature matching. Prior to change detection, we defined type of updating between different network data-sets. Next, we transformed road lines into areal features(block) that are surrounded by them and calculated a shape similarity between blocks in different data-sets. Blocks that a shape similarity is more than 0.6 are selected candidate block pairs. Secondly, we detected changed-block pairs by bipartite graph clustering or properties of a concave polygon according to types of updating, and calculated Fr$\acute{e}$chet distance between segments within the block or forming it. At this time, road segments of KAIS map that Fr$\acute{e}$chet distance is more than 50 are extracted as updating road features. As a result of accuracy evaluation, a value of detection rate appears high at 0.965. We could thus identify that a proposed method is able to apply to change detection between different network data-sets.

High Heat-load Slits for the PLS Multi-pole Wiggler (포항방사광가속기의 다극 위글러용 고 열량부하 슬릿)

  • Gil, K.H.;Kim, C.K.;Chung, C.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.1
    • /
    • pp.46-51
    • /
    • 2007
  • The HFMX((High Flux Macromolecular X-ray crystallography) beamline at Pohang Accelerator Laboratory uses beams from a multi-pole wiggler. Two horizontal and vertical slits relevant to high heat-load are installed at its front-end. In order to treat high heat-load with reducing beam scattering, the horizontal slit has two Glidcop blocks with a grazing incidence angle of $10^{\circ}$ of a grazing-incidence knife-edge configuration. The blocks adjust the slit gap by being translated along guides by two actuating bars, respectively. Water flowing through holes, drilled along the actuating bars, cools the heat-load of both blocks. The vortical slit has the same structure as the horizontal slit except its installation direction with respect to the vacuum chamber and its grazing incidence angle. By virtue of a pair of blocks translating on guides, no alignment between both blocks is required and the installed slits show stable operating performance. The cooling performance of the two slits has been also shown to be acceptable. In this paper, the detailed explanation for the design of the two slits is presented and their operating performance is discussed.

A Study on the Thermo-Flow Analysis of Air Conditioning Electric Compressor Motor System for Hybrid Electric Vehicles (하이브리드 자동차 에어컨용 전동식 압축기 모터 시스템의 열유동 해석 연구)

  • Kim, Sung Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.592-597
    • /
    • 2013
  • The heat generated at the motor and inverter inside the electric compressor of inverter built-in type is mainly cooled by refrigerant and generally, there is not a thermal problem. However, the close relation of heat transfer from the motor and inverter parts to the compression part affects on compressor efficiency. Also, according to the surrounding environment and system operation condition, the increased temperature of the motor and inverter can affect the power density of the motor system, and especially, the inverter may be prevented to operate by the temperature limits. In this study, we performed thermo-flow analysis of electric compressor motor system, and investigated the heat dissipation enhancement of the motor and inverter. The motor part in the operation region of the electric compressor was generally maintained at low temperature and the inverter part at high compressor speed was lower temperature than the temperature limit of $85^{\circ}C$. However, the case of the inverter at low speed harsh condition was in excess of $10^{\circ}C$. Therefore, in order to solve the thermal problem, the heat reduction technology of the motor and inverter is essential as well as the improvement of flow path in the compressor.