• Title/Summary/Keyword: 내부 온도 분포

Search Result 474, Processing Time 0.042 seconds

건식저장 용기내 PWR 사용후핵연료 열전달 해석

  • In, Wang-Gi;Sin, Chang-Hwan;Yang, Yong-Sik;Jeon, Tae-Hyeon;Song, Geun-U;Choe, Jong-Won
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2009.11a
    • /
    • pp.475-476
    • /
    • 2009
  • CFD 방법을 이용하여 건식저장 용기내 사용후핵연료 열전달 해석을 수행한 결과 연료봉의 붕괴열에 의한 내부 유체의 자연대류 현상과 상세 핵연료 온도분포를 예측할 수 있음을 확인하였다. 향후에는 다양한 시험조건에서 복사열전달을 포함한 정밀한 CFD 계산을 수행하여 피복관 온도분포의 예측치를 실험결과와 비교할 예정이다.

  • PDF

Numerical Analysis of Natural Convection inside Spray Coating Room on Temperature Distributions (자연대류를 고려한 스프레이 코팅 룸에서의 온도분포 해석)

  • Kim, Nam Woong;Kim, Bo-Seon;Kim, Kug Weon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.425-430
    • /
    • 2019
  • Zinc coatings are widely used because of their environmental friendliness and high performance. In general, the coating temperature is a major factor in determining the coating layer thickness and coating quality. In the case of a zinc coating, a uniform and appropriate coating temperature is required. In this study, a thermal flow simulation of the air flow was performed to analyze the temperature distribution of a zinc spray coating room in a natural convection state. Using SolidWorks, modeling was performed for two spray coating rooms, a preheating room, and a drying room, and a thermal flow coupled analysis was performed using ANSYS-FLUENT. As a result of the analysis, the temperature distribution characteristics in the spray coating rooms were determined. It was found that the present temperature was below the target temperature of $25^{\circ}C$. Simulations were conducted for two different boundary conditions (one with a heater added and another with the open part closed). The simulation results show that the method of closing the open part is better than adding the heater.

Internal Structure and Weibull Modulus of $Al_2$$O_3$Ceramics Sintered with Addition of MgO (마그네시아 첨가 $Al_2$$O_3$세라믹스의 내부구조 및 Weibull Modulus)

  • 조용익;유선균;정상귀;조성용;김승재;오꾸미야마사타로
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.5
    • /
    • pp.479-484
    • /
    • 2001
  • 고순도 알루미나 분말에 소결조제로서 MgO를 0ppm 및 500ppm 첨가하여 열분무건조기를 사용하여 준비한 과립을 80$0^{\circ}C$에서 하소를 함으로써 얻어진 과립으로 제작한 소결체의 MgO 첨가량에 따른 미세구조와 꺾임강도에 미치는 영향을 고찰하였다. 또한 시편두께를 50$mu extrm{m}$의 박편으로 가공하여 투광법으로 내부구조도 관찰하였다. MgO를 500ppm 첨가하여 제작한 과립을 180 MPa의 냉간정수압성형성 후 1$600^{\circ}C$에서 소결한 소결체는 상대밀도가 100%에 도달하였고 균일한 결정립성장의 치밀한 미세구조를 나타내었다. MgO를 500ppm 첨가한 시편의 4점 꺾임강도 또한 각 소결온도에서 MgO를 9ppm 첨가한 시편보다 23%-32%정도 높은 강도를 나타내었으며, 특히 소결온도 1$600^{\circ}C$에서는 꺾임강도가 501MPa 그리고 weibull 계수가 20의 고강도이면서 신뢰성이 높은 알루미나 소결체가 얻어졌다. 본 연구에서는 weibull 계수의 값이 높은 시편일수록 내부구조의 결함크기가 작고 이 작은 결함이 시편내부에 균일하게 분포되어 있음을 확인할 수 있었다.

  • PDF

A Study on the External Wall Heating Temperature Distribution According to Opening Upper Shading Installation and Length (개구부 상부 차양설치 및 길이에 따른 외벽 수열온도분포에 관한 연구)

  • Jung, Ui-In;Hong, Sang-Hun;Kim, Bong-Joo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.4
    • /
    • pp.339-345
    • /
    • 2020
  • This study used a real-scale model experiment to reproduce internal fires in residential buildings such as a multi-dwelling unit, in order to prevent damage caused by tens of thousands of fires witnessed each year and to take measures to cope with them. For experimental conditions, different opening sizes were applied to measure and analyze the heating temperature of the exterior wall. Results drawn are as follow : On top of this, the experimental conditions had whether to install shading and put a shading length differently, before measuring and analyzing the heating temperature of the exterior wall. Subsequent results were drawn as shown below. Based on the maximum temperature, the temperature was lowered as much as around 90℃ at 150mm, around 150℃ or over at 300mm and over 175℃ at 450mm. It also turned out that the difference in maximum temperature dropped by around 180℃ or over. This indicated that the shading installation works well in lowering flame temperature generated by fire spread of the exterior wall.

Experimental Study on Internal Temperature Change Induced by Heating Element Attached to Tunnel Lining Surface (터널 라이닝 표면에 부착된 발열체로 인한 내부 온도 변화의 실험적 연구)

  • Jin, Hyunwoo;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.11
    • /
    • pp.35-40
    • /
    • 2017
  • The rearside of concrete lining of tunnels constructed in cold region might experience on freezing due to the low temperature. This causes damage of concrete lining resulting in adverse affect on the durability as well as integrity of tunnel structure by causing damage to the concrete lining. In order to prevent the rearside of tunnel lining from freeing, the temperature change inside the concrete lining was measured by attaching a heating element to the tunnel lining surface and generating heat for a certain period of time. A special freezing chamber was developed to conduct the experiments considering in-situ environment. The carbone nanotube (CNT) was used as a heating element in this study. The temperature distribution of the concrete lining was measured by applying the heat to the heating element. The effect of the outside temperature and heating duration were analyzed.

Structural Fire Analysis of a Composite Beam Protected by Fire-Resistant Materials (내화피복을 적용한 강합성보의 구조화재해석)

  • Jun Won Kang;Moon Soo Kang;Hyejin Yoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.2
    • /
    • pp.137-145
    • /
    • 2023
  • This paper presents the effects of fire-resistant materials on the temperature and vertical deflection of a composite beam exposed to fire through nonlinear thermo-mechanical analysis. The fire was modeled using the standard fire curve proposed in American Society for Testing and Materials (ASTM) E119. Fire-resistant materials were modeled by reducing the heat transfer coefficient from the air layer to the beam. The temperature and vertical deflection of the uncoated composite beam were measured using a laboratory fire test, and the results of the structural fire analysis were verified through comparison with experimental results. By introducing the fire-resistance effect, the reduction in the temperature and deflection of the beam for the ASTM E119 standard fire can be reasonably estimated. Based on a case study of the heat transfer coefficient, the fire-resistant effect on the thermo-mechanical response of a composite beam in the event of a fire is presented.

Spalling and Internal Temperature Distribution of High Strength Column Member with Polypropylene Fiber Volume Fractions (폴리프로필렌섬유 혼입률에 따른 고강도콘크리트 기둥부재의 폭렬 및 내부온도 분포특성)

  • Won, Jong-Pil;Jang, Chang-Il;Lee, Sang-Woo;Kim, Heung-Youl;Kim, Wan-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.821-826
    • /
    • 2008
  • This study evaluated spalling and internal temperature distribution after elevated temperatures test for high strength concrete ($f_{ck}=60\;MPa$) column member with various polypropylene fiber volume fractions. The ISO-834 time-temperature curve was used for measurement of fire resistance properties. As the result of test, average internal temperature results indicated to low temperature in increased polypropylene fiber volume fraction. But, the highest internal temperature results show that does not difference in proportion of polypropylene fiber volume fractions.

An Experimental Study on the Characteristics of Temperature Distribution in Internal Space of a Tube for the Formal Change of Counterflow Type Vortex Tube (대향류형 보텍스 튜브의 노즐형상 변화011 따른 튜브 내부의 온도분포에 관한 실험적 연구)

  • 황승식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.69-76
    • /
    • 2002
  • The aim of this study is to provide fundamental informations that make it possible to use a cool stream and a hot stream simultaneously. We changed the pressure of compressed air that flows into a tube, the inner diameter of orifice that a cold stream exits, and the mass flow rate ratio. And in each case, we measured the temperature of a cold stream and a hot stream in each exit of a tube. Also we measured the axial and the radial temperature distribution in internal spare of a tube. From the study, fellowing conclusive remarks 7an be made. First, As the number of nozzles increase, separation point move into the hot exit. Second, When we use guide vane type nozzle, the axial temperature distribution constant over the 0.75 of air mass flow rate radio. Third, When we use Spiral type nozzle, axial and radial temperature distribution in the inner space is higher than another nozzle. Fourth, Axial and radial temperature distribution in the inner space vortex-tube is determined by separation point. And separation point is moved by changing of air mass flow rate ratio. At last, A heating apparatus is possible far vortex-tube to use.

An Analysis of Geophysical and Temperature Monitoring Data for Leakage Detection of Earth Dam (흙댐의 누수구역 판별을 위한 물리탐사와 온도 모니터링 자료의 해석)

  • Oh, Seok-Hoon;Suh, Baek-Soo;Kim, Joong-Ryul
    • Journal of the Korean earth science society
    • /
    • v.31 no.6
    • /
    • pp.563-572
    • /
    • 2010
  • Both multi-channel temperature monitoring and geophysical electric survey were performed together for an embankment to assess the leakage zone. Temperature variation according to space and time on the inner parts of engineering constructions (e.g.: dam and slope) can be basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation (e.g.: cracks and defects) could be generated by various factors. Seepage or leakage of water through the cracks or defects in old dams will directly cause temperature anomaly. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For that matter, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old earth fill dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body. Geophysical data by electrical method are also added to help interpret data.

High temperature oxidation of MCrAlY thermal barrier coating (MCrAlY 열차폐 코팅의 고온산화)

  • 고재황;이동복
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.219-219
    • /
    • 2003
  • HVOF(High Velocity Oxygen Fuel)법을 사용한 MCrAlY(M=Ni, Co, Fe)계 열차폐 코팅(thermal barrier coating)은 열기관 내부의 극심한 환경 부하에 대해 구조물 표면에 열적, 화학적 장벽을 형성함으로써 구조물의 내구성을 향상시킨다 이와 동시에 열차폐 효과는 구조물의 온도상승 없이 내부 가동 온도를 높일 수 있게 함으로써 열효율을 상승시키고 연료 효율을 높여 가동비용 절감을 이룰 수 있는 동시에 고 연소를 통한 오염원의 배출을 감소시킬 수 있다. 본 연구에서는 $H_2O$$_2$=5:1 분위기 하에서 HVOF법을 사용하여 Hastelloy-X 기판위에 125$\mu\textrm{m}$의 두께로 다음 5종류의 (Ni, Co, Cr)계 MCrAlY 코팅을 용사시켰다. 준비된 (Ni, Co)-Cr-Al-(Y, Ta, Re), (Ni, Co)-Cr-Al-(Y, Re), (Ni, Co)-Cr-Al-(Y, Ta), (Ni, Co)-Cr-Al-Y, (Ni,Co)-Cr-Al-Ir 코팅시편에 대한 산화성질을 조사하기 위해 대기 중 1000, 1100, 120$0^{\circ}C$에서 50, 100, 150, 200시간 등온실험(Isothermal oxidation)을 실시하였고, XRD, SEM/EDS, EPMA를 이용하여 생성된 산화막과 코팅 시편의 조직 변화를 조사하였다. 산화온도와 산화시간이 증가할수록 산화막의 박리가 많이 발생하였으며, 분석 결과 미세하게 분포된 a-Al$_2$O$_3$ 입자, NiCr$_2$O$_4$스피넬 상, 미세한 Cr$_2$O$_3$가 관찰되었고, 코팅 조성 변화에 따라 형성되는 이들 산화물의 존재비가 달라졌으며, 산화온도가 높아질수록 산화속도가 가속화되었다.

  • PDF