• Title/Summary/Keyword: 내부부하

Search Result 389, Processing Time 0.034 seconds

Design of SPIM(Single Phase Induction Motor) for Compressor Using Load Matching (Compressor용 단상유도전동기의 부하 Matching 설계)

  • Shim, Jang-Ho;Ju, Jung-Hoon;Eum, Sang-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.807-809
    • /
    • 2003
  • 본 논문에서는 회전형 압축기용 단상유도 전동기의 부하 matching 설계에 관하여 다루었다. 압축기 내부에서의 전동기 운전 온도를 알기 위해 압축기 실험을 행하였고 부하 토크를 추정하기 위해 전동기의 상온 및 실기조건 실험을 행하였다. 추정된 부하 토크를 적용하여 재설계 및 기존 전동기와 비교 검토하였다.

  • PDF

Actuator and load test system development for continuous variable thruster (연속가변 추력기용 구동장치 및 부하시험장비 개발)

  • Kim, Namjin;Kim, Hyoungkwon;Park, Hyunho;Lim, Jinwan;Suh, Suhkhoon;Park, Iksoo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.401-405
    • /
    • 2017
  • Continuous variable thrusters require precise thrust control to change the position or attitude of the aircraft and to control the pressure inside the combustion chamber. For this purpose, the thrust is adjusted by moving the pintle structure near the nozzle neck inside the combustion chamber by moving the pintle structure forward and backward, and the actuator is used to move the pintle structure. In this paper, we developed a actuator system for continuous variable thruster and load test system to simulate the load under operating conditions. Also, the performance test of the actuator was performed using the developed load test system

  • PDF

Energy Plus 부하 해석 프로그램

  • 공성훈
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.29 no.7
    • /
    • pp.56-59
    • /
    • 2000
  • Energy Plus의 첫 작업버전인 알파 버전은, 작업 팀에 의한 내부 테스트가 1998년 12월에 이루어 졌으며, 외부 사용자들이 1999년 말에 테스트를 하여 2001년 초에는 Energy Plus 버전 1.0을 개발할 예정이며 향후에도 지속적인 개발을 계획 하고 있다. Energy Plus는 BLAST와 DOE-2의 장점과 많은 새로운 시뮬레이션 성능을 지닌 에너지 시뮬레이션 프로그램이 될 것으로 기대한다 Energy Plus 프로그램의 주요기능은 다음과 같다. · 열평형 부하 계산 · 동일 시간대에서 통합된 부하, 시스템, 플랜트 계산 · 사용자 위주의 HVAC 시스템 해석 · 다른 개발자가 새로운 시뮬레이션 모듈을 첨가하기 용이 한 모듈구조 · 그래픽 작업이 용이한 간단한 입력과 출력데이터 양식

  • PDF

DC Characteristics Analysis of Various AC loads for Hybrid Distribution (하이브리드 급전을 위한 다양한 가정용 교류부하의 직류특성연구)

  • Lee, Young-Jin;Han, Dong-Ha;Choi, Jung-Muk;Jeong, Byong-Hwan;Kim, Dong-Jin;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.207-217
    • /
    • 2010
  • Recently, the use of DC power increased due to the increased use of digital load. Power factor of input current decrease and input current harmonics increase, and conversion loss which is occurred in the AC / DC converter is a problem to provide the proper DC voltage to the device equipped with an internal AC / DC converter. Hybrid system supplies the AC power and DC power to AC load (motor load and the transformer load) and DC loads (computers, TV, LED fluorescent light) at the same time it supplies the renewable energy and utility energy taken power from Utility to user for improving the efficiency and renewable energy improvements in ease of use. This paper studies DC characteristics of traditional AC load for Hybrid distributions.

A Study on Methodology for Protection of Malicious Traffic in Groupware Network System (그룹웨어시스템상의 악성트래픽 차단 네트워크구조 설계방법)

  • Noh, Si-Choon;Bang, Kee-Chun
    • Journal of Digital Contents Society
    • /
    • v.8 no.1
    • /
    • pp.69-76
    • /
    • 2007
  • The blocking of malicious traffic in groupware network system is used to prevent the spread and distribution of malicious traffic. The method protecting from malicious traffic in groupware system is designed to handle the malicious traffic of various routes with the internal course of groupware, which leads to lighten the load of security and traffic. It was impossible to block this kind of traffic at the traditional structure. When the protection of the proposed groupware system is performed, there appears to be a great change for the rate of a load factor at the CPU of Backbone Switch which is connected to the internal gateway. The load factor of CPU, which was increased with the traffic, is now remarkably reduced after the internal gateway is set up. This is to show that a lot of malicious traffic pass through the internal network and that network environment is faced to the menace of many malicious traffics. This paper is to show the efficiency of protection of internal gateway proposed in this study, for the rate of CPU of Backbone Switch was about 17% a day, but was dropped up to the 4% after the malicious traffic was removed.

  • PDF

Utilizing Channel Bonding-based M-n and Interval Cache on a Distributed VOD Server (효율적인 분산 VOD 서버를 위한 Channel Bonding 기반 M-VIA 및 인터벌 캐쉬의 활용)

  • Chung, Sang-Hwa;Oh, Soo-Cheol;Yoon, Won-Ju;kim, Hyun-Pil;Choi, Young-In
    • The KIPS Transactions:PartA
    • /
    • v.12A no.7 s.97
    • /
    • pp.627-636
    • /
    • 2005
  • This paper presents a PC cluster-based distributed video on demand (VOD) server that minimizes the load of the interconnection network by adopting channel bonding-based MVIA and the interval cache algorithm Video data is distributed to the disks of each server node of the distributed VOD server and each server node receives the data through the interconnection network and sends it to clients. The load of the interconnection network increases because of the large volume of video data transferred. We adopt two techniques to reduce the load of the interconnection network. First, an Msupporting channel bonding technique is adopted for the interconnection network. n which is a user-level communication protocol that reduces the overhead of the TCP/IP protocol in cluster systems, minimizes the time spent in communicating. We increase the bandwidth of the interconnection network using the channel bonding technique with MThe channel bonding technique expands the bandwidth by sending data concurrently through multiple network cards. Second, the interval cache reduces traffic on the interconnection network by caching the video data transferred from the remote disks in main memory Experiments using the distributed VOD server of this paper showed a maximum performance improvement of $30\%$ compared with a distributed VOD server without channel bonding-based MVIA and the interval cache, when used with a four-node PC cluster.

Analysis of the electromagnetic fields in microwave cavities and the temperature fields in loads using Finite-Difference Time Domain method (FDTD방법을 이용한 마이크로웨이브오븐의 전자파 해석 및 부하의 열해석)

  • Cho, S.H.;Lee, Y.M.;Kim, H.J.;Kang, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2459-2461
    • /
    • 1999
  • FDTD(Finite-Difference Time-Domain) 방법을 이용하여 마이크로웨이브 오븐 내부 전자파를 해석하였고, 열전달방정식을 이용하여 부하의 열 분포를 해석하였다. 다양한 형태의 오프닝구조를 갖는 캐비티에 관하여 수치계산을 수행하였고, 서로 다른 종류의 부하가 존재할 때 부하의 온도 분포가 어떻게 변화하는지 알아보았다. 또한 마그네트론의 안테나와 캡이 존재하는 실제 웨이브가이드를 모델링하여 수치 계산한 후, 적외선사진에 의한 부하의 온도분포와 비교하였다.

  • PDF

A Simulation for Analysis of Stability of Gas Turbine Governor using PSS/E (가스터빈 조속기의 안정도 해석을 위한 PSS/E 모의 실험)

  • 최인규
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1999.10a
    • /
    • pp.267-271
    • /
    • 1999
  • 연료를 작동 유체의 내부 또는 외부에서 연소시켜서 발생된 고온 고압의 가스를 터빈에 공급하여 회전력을 발생시키는 원동기를 가스터빈이라 하며, 가스터빈을 이용한 발전기와 달리 기동 및 정지 시간이 대단히 짧고, 부하 변화에 대한 속응성이 뛰어나기 때문에 전력계통 운영상 양수 발전기나 수력 발전기와 더불어 첨두 부하용으로 주로 사용된다. 본 고에서는 전력 계통에 병렬 운전 중인 가스터빈 발전기의 부하가 탈락되어 입력 에너지가 과잉으로 되었을 때, 제어 시스템의 중요한 파라미터인 연료량과 가스터빈 속도 및 배기가스의 온도가 비상 정지 수준에 도달하지 않고 안전하게 운전될 수 있는지의 여부, 즉 안정성을 판별하기 위하여 수행한 모의 시험에 대하여 기술하였다. 또, 부하가 탈락되지 않고 입력되는 연료량이 크게 변동하는 경우, 즉 큰 부하 변동을 모의 시험한 내용에 대하여 기술하였다.

  • PDF

A study on flux characteristics from the submerged soils of Yeongju dam (영주댐 수몰지 토양의 용출 특성 분석)

  • Lee, Seungyoon;Shin, Cholong;Choi, Kwangsoon;Kim, Hojoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.462-462
    • /
    • 2018
  • 국내 신규댐 건설에 있어, 침수토양의 용출에 의한 호내 수질영향에 대해서는 현재까지 정량화된 사례는 찾기 어려우며, 댐 담수 초기에 증가되는 오염원에 대한 정확한 조사자료의 부족으로 담수이후의 수질변화에 대한 정확한 예측이 어려운 실정이다. 따라서 외부 오염부하의 강우시 유입과 퇴적물로부터의 영양염용출 등의 내부 오염부하가 함께 고려된 수질예측기법의 적용이 필요하다. 수몰지 토양 및 호내로부터의 내부부하에 있어서는 퇴적물 내의 다량 존재하는 오염물이 재용출 되거나 퇴적물 내의 화학적 생물학적 반응이 하천 수질에 악영향을 미치게 된다. 대부분 수몰지토양에서 수층으로 용출되는 유기물의 양은 수층에서 퇴적물로 흡수 또는 침강 되는 것보다 많은 경우도 있으며, 오염된 수계에서는 내부 부하량이 과다할 경우 수질 개선을 어렵게 하는 요인이 되고 있다. 따라서 본 연구에서는 2016년 시험담수 예정지인 신규댐 수몰지를 대상으로 토양에 포함된 유기물이 자연상태에서 수체로 용출되는 특성을 분석하여 수질에 미치는 영향을 검토하고자 한다. 댐 수몰지의 토양 시료는 시험담수전 2016년 7월, 토지이용 유형별로 5개지점(논, 밭, 대지, 임야, 하천)에서 시료를 채집하여 총 36일간 용출실험을 실시하였으며, 수층내 용존산소 조건을 호기성 조건과 혐기성 조건으로 나누어 실험하였다. 수질분석은 COD, T-N, T-P, $PO_4-P$등 9개 항목에 대해 실험기간 중 13회 실시하였다. 토양별 점유면적 대비 일 용출량은(kg/day) COD 63 kg/day, T-N 93.6 kg/day, T-P 5.8 kg/day, $PO_4-P$ 4.6 kg/day 였으며, 수몰지 내 토지이용현황별 오염원 기여율은 임야, 밭, 하천, 논, 대지 순 이었다. 본 실험은 수몰지토양의 순수용출량만을 담수개시~36일간 측정한 결과로서 실제 저수지환경에서는 실험값보다 낮을 것으로 판단되며, 수중 수질환경 변화 및 퇴적물의 퇴적 등으로 인하여 원토양으로부터의 용출로 인한 수질에의 영향은 시간의 경과와 함께 변화 또는 감소될 것으로 예상된다. 따라서 본 실험결과는 담수초기의 영향으로 국한하여 해석하는 것이 바람직하며, 보다 장기적인 영향파악을 위해서는 담수 후의 퇴적물의 거동(퇴적현황) 파악 및 담수 후 퇴적물의 장기용출실험을 통한 용출량 검토가 필요하다.

  • PDF

Effect of turbidity current on organic carbon cycle in Daecheong reservoir (탁수가 대청호 유기탄소 순환에 미치는 영향)

  • Dong Min Kim;Se Woong Chung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.148-148
    • /
    • 2023
  • 산업 고도화로 인하여 복잡하고 다양한 유기물의 사용량이 증가하였으며, 공공수역 내 새로운 오염물질이 유입됨에 따라 생화학적 산소요구량(BOD) 중심의 수질평가에 한계를 나타내었다. 이후 난분해성 물질을 고려한 유기물관리 정책과 총량관리의 필요성이 제기되었고 국내 하천과 호소에서는 총 유기탄소(TOC)를 유기물 관리지표로 설정하였다. 그러나 부영양 하천과 호소에서 TOC는 외부 부하뿐만아니라 식물플랑크톤의 과잉성장에 의해 증가할 수 있는 항목이므로 TOC 관리정책 추진을 위해서는 유기물의 기원에 대한 파악이 필요하다. 한편, 우리나라와 같이 몬순 기후대에 속한 댐 저수지의 경우 강우시 유입하는 탁수에 의해 다량의 유기물과 인이 유입되기도 하지만 식물플랑크톤의 제한요인 중 광량에 많은 영향을 미친다. 식물플랑크톤의 광합성은 수체 내 유기탄소 내부생성에 매우 중요한 요소이나 점 단위의 실험적 방법을 활용한 유기탄소 순환 해석은 저수지의 시·공간적인 변동성을 고려하기에 한계가 있다. 본 연구의 목적은 금강 수계 최대 상수원인 대청호를 대상으로 3차원 수리-수질 모델을 적용하여 유기탄소 성분 별 유입과 유출, 내부생성 및 소멸량을 평가하고 탁수가 저수지에서의 유기탄소 순환에 미치는 영향을 분석하는데 있다. 유기탄소 물질수지 해석을 위해 AEM3D 모델을 사용하였으며 2018년을 대상으로 입력자료를 구축한 후 보정 및 검정을 수행하였다. 모델은 유기탄소를 입자성, 용존성, 그리고 난분해성과 생분해성으로 구분하여 모의하며 유기물질 성상별 실험결과를 이용하여 입력자료를 구축하였으며 유기탄소순환 해석을 위해 4가지의 탄소성분과 조류 세포 내 탄소의 질량 변화율을 계산하였다. 이를 위해 외부 유입·유출부하율, 수체 내 생성(일차생산, 재부상, 퇴적물과 수체 간 확산) 및 소멸률(POC 및 조류 침강, DOC 무기화, 탈질)을 고려하였으며 탁수의 영향을 분석하기 위해 탁수 포함여부 시나리오를 구성하고 유기탄소 생성 및 소멸기작별 변동성을 비교 분석하였다. 모델은 2018년의 물수지를 적절히 재현하였으며 저수지의 수온 및 탁도 성층구조를 잘 재현해내면서 전반적인 수질을 적절하게 모의하였다. 탁수를 고려하였을 시 연간 TOC 부하량 중 내부기원 부하량은 56% 수준이였으나 탁수를 배제한 경우 내부기원 부하량은 82%로 나타났다. 특히, 연평균 Chl-a 농도가 44~48% 차이가 발생하면서 1차생산량이 약 4배가량 증가하였다. 몬순지역에서의 탁수는 체류시간이 긴 성층 저수지에서 식물플랑크톤 성장제어에 큰 영향을 미쳤으며 전반적인 유기탄소 순환을 해석하는데 있어 매우 중요한 인자로 작용하였다.

  • PDF