• 제목/요약/키워드: 내구 성능

검색결과 1,221건 처리시간 0.041초

A Study on the Shear Fatigue Performance of Elastomeric Bearings of a Doublefold Elastomeric Layer (고무의 겹침제작 여부에 따른 탄성받침의 전단피로특성 연구)

  • Yoon, Hye-Jin;Kwahk, Im-Jong;Kim, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.69-72
    • /
    • 2008
  • Bridge bearings are devices absorbing the displacements of the superstructure. Elastomeric bearings used generally as bridge bearings absorb the displacements of the superstructure using their rubber characteristics. Elastomeric bearings should make sure their shear fatigue performance not to impede the durability of bridge system. In this paper shear fatigue tests were performed and stiffness were measured through the shear fatigue tests. Tests results show the measured stiffness of elastomeric bearings have no specific tendency. This paper found that elastomeric bearings show bad shear performance or fail early if elastomeric bearings are manufactured with a doublefold elastomeric layer.

  • PDF

Effect of Compensation for Thickness Reduction by Chemical Degradation of PEMFC Membrane on Performance and Durability (PEMFC 고분자막의 화학적인 열화에 의한 두께 감소 보정이 성능 및 내구성에 미치는 영향)

  • Sohyeong Oh;Yoojin Kim;Seungtae Lee;Donggeun Yoo;Kwonpil Park
    • Korean Chemical Engineering Research
    • /
    • 제62권1호
    • /
    • pp.1-6
    • /
    • 2024
  • As the demand for hydrogen electric vehicles for commercial vehicles increases, the durability of PEMFCs must increase more than five times that of passenger cars, so research and development to improve durability is urgent. When the PEMFC membrane electrode assembly (MEA) undergoes chemical degradation, the MEA thickness decreases and pinholes occur. In this study, changes in the performance and durability of the MEA were measured while increasing the clamping pressure of the unit cell after open circuit voltage (OCV) holding, an accelerated chemical degradation experiment. As the clamping pressure increased, the resistance of the polymer membrane and the membrane/electrode contact resistance decreased, improving the I-V performance and reducing the hydrogen permeability. As the hydrogen permeability decreased, the OCV increased. When the pinhole area was removed and the MEA clamping pressure was increased, the hydrogen permeability decreased sharply, confirming that the local degradation has a large effect on the performance and durability of the entire cell. When the pinhole was removed and re-clamping and OCV holding was evaluated, it was confirmed that the durability improved according to the decrease in membrane resistance and hydrogen permeability.

An Experimental Study on the Alkali-Recovery Performance of Impregnating Alkalization Agent for Deteriorated Concrete by Carbonation (침투성 알칼리성부여제 도포에 의한 중성화된 콘크리트의 알칼리성 회복성능에 관한 실험적 연구)

  • 김무한;강석표;유재강;권영진
    • Journal of the Korea Concrete Institute
    • /
    • 제13권1호
    • /
    • pp.9-15
    • /
    • 2001
  • The low-durability performance of concrete structure occurs by interactive deterioration factors. In particular, carbonation increased with its time elapse is known as the general manner of deterioration characteristics. Recently, the fundamental researches of the carbonation mechanism, besides method and technique for durability improvement of deteriorated structure are advanced actively. So in this paper, alkali-recovery and maintenance performance when the impregnating alkalization agents are used, are compared and examined quantitively with the basis of past proposed study. As a result, alkali-recovery performance be ensured by impregnating alkalization agent on the carbonated concrete which has low pH by accelerated carbonation test. And alkali maintenance performance was effected by the finishing materials on the alkali recovered concrete.

Enhanced Durability Performance of High Early Strength Concrete for Early Traffic Opening (조기교통개방 콘크리트의 내구성능 향상에 관한 연구)

  • 원종필;김현호;안태송
    • Journal of the Korea Concrete Institute
    • /
    • 제13권4호
    • /
    • pp.362-370
    • /
    • 2001
  • The internal or external restraint of thermal and dry shrinkage movements could thus generate tensile stresses in concrete pavement for early traffic opening. Restrained shrinkage and thermal stresses could produce microcracks in concrete which increase its permeability and accelerate its long-term deterioration under weathering and load effects. Fiber reinforced concrete is an effective approach to the control of microcrack and crack development under tensile stresses. This study aims at evaluation of the durability of high early strength concrete for early traffic opening and increase of service life. Three different types of regulated-set cement which recently has been used much in Korea were adopted. Fibers were added and their mixtures were compared with plain high early strength concrete mixture. The use of fibers increased durability performance of high early strength concrete using regulated-set cement than the corresponding plain mixtures.

A Study on Performance-based Evaluation Method for Rock Slopes : Deduction of Evaluation Factors (암반비탈면의 성능기반 평가기법 연구 : 평가항목 도출)

  • Lee, Jong-Gun;Suk, Jae-Wook;Kim, Hong-Kyoon;Kim, Yong-Soo;Moon, Joon-Shik
    • Tunnel and Underground Space
    • /
    • 제25권1호
    • /
    • pp.86-96
    • /
    • 2015
  • In this study, the performance-based evaluation factors for rock slopes have been deducted using Delphi-method. Validity of the result was verified through factor analysis. Performance of rock slope is classified as soundness, stability and durability. Through the Delphi survey, 17 factors including discontinuity orientation are deducted for soundness, 4 factors and 3 factors are selected for stability and durability, respectively. Validation is conducted using Exploratory Factor Analysis (EFA) for 24 factors, and all factors are found to be valid. As a result of Exploratory Factor Analysis (EFA), 3-types of performance were subdivided into internal soundness, external soundness, risk, damage and durability of slopes and protection (reinforcement) facilities.

A study on performance evaluation of rod rubber bushing under static and fatigue loadings (토크 로드 부품의 정하중 및 피로하중하에서의 성능평가 연구)

  • 이순복;김완두
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제14권5호
    • /
    • pp.1320-1329
    • /
    • 1990
  • A static performance tester for a torque rod assembly was developed to evaluate the three characteristics of the rod rubber bushing : radial spring characteristic, thrust spring characteristic, and rotational torque characteristic. Among the various schemes considered in the conceptual design stage, the final versatile type was determined to perform three different tests in one machine. The performance testing machine carried out radial spring test, thrust spring test, and torque test of the torque rod assembly. Static performance of the torque rod assembly was evaluated with the tester developed and fatigue strength of the assembly was also tested with the servo-hydraulic structural fatigue testing machine. The life of the component was found to be related with the rubber quality and adhesionability between the rubber and the steel rod. The optimum rubber hardness was experimentally found by changing the chemical compositions of rubber, and the adhesion was improved by optimizing the shape of the outer section of a the rubber, this study ensured the development of a reliable torque rod assembly.

A Study on Pd-based Electrode prepared by using Electroless Plating Method (무전해도금법을 이용한 Pd 기반 전극·제조에 관한 연구)

  • Hwang, In Hyuck;Lee, Dong Yoon;Kim, Sung Su
    • Journal of the Korean Applied Science and Technology
    • /
    • 제35권4호
    • /
    • pp.1338-1347
    • /
    • 2018
  • In this study, Ti-mesh based electrodes were fabricated for the application of anode to the electrolysis process for wastewater treatment using Pd electroless plating method. The removal performance of the prepared Pd / Ti-mesh electrode was evaluated as representative dye RO16, and the durability and performance were maximized by varying the electrode manufacturing conditions. As a result, it was confirmed that the coating condition had no significant effect on the performance, and that the heat treatment process greatly affected the performance and the durability was improved. In addition, we tried to maximize performance and durability by complexing Ir, Ru, and Ta. However, as the thickness of the layer increased due to the limitation of the coating method, the resistance increased and the performance decreased accordingly.

Material Properties of Fast hardening Polymer Mortar by Fine Aggregate Types and Replacement Ratio (잔골재 종류 및 치환율에 의한 속경성 폴리머 모르타르의 재료 특성)

  • Shin, Seung-Bong;Kim, Gyu-Yong;Nam, Jeong-Soo;Shin, Kyoung-Su;Lee, Bo-Kyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제23권4호
    • /
    • pp.145-151
    • /
    • 2019
  • The Physical performance of use materials was evaluated to improve durability of fast-paced repair mortar used at rapid construction sites. The fastening performance and basic performance were evaluated by substituting ferronickel grinding slag residues, rapid settlement, and EVA-based polymer for mortar. As a result, the compressive strength, flexural strength and adhesion strength were increased due to the use of FS Fine Aggregate and RS Fine Aggregate. The chloride ion promotion test of fast-polymer mortar kept the chloride inhibitory performance from 7 days to 28 days when fNS was used less than 50%. Durability degradation due to the use of FS Fine Aggregate and RS Fine Aggregate has not been found, and it is believed that further consideration of economic and long-term durability will be required for use as alternative Aggregate for construction and civil engineering.

Evaluation of Service Life in RC Column under Chloride Attack through Field Investigation: Deterministic and Probabilistic Approaches (염해 실태조사를 통한 철근 콘크리트 교각의 내구수명 평가 - 결정론적 및 확률론적 해석방법)

  • Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제19권5호
    • /
    • pp.67-74
    • /
    • 2015
  • RC (Reinforced Concrete) structures are considered as cost-benefit and durable however performances of structural safety and durability are degraded due to steel corrosion. Service life in RC structure is differently evaluated due to different local environmental conditions even if it is exposed to the same chloride attack. In the paper, 25 concrete cores from field investigation are obtained from 4 RC columns with duration of 3.5~4.5 years exposed to sea water. Through total chloride content measurement, surface chloride contents and apparent diffusion coefficients are evaluated. Service life of the target structure is estimated through deterministic method based on Fick's $2^{nd}$ Law and probabilistic method based on durability failure probability, respectively. Probability method is evaluated to be more conservative and relatively decreased service life is evaluated in tidal zone and splash zone over 40.0 m. Chloride penetration behavior with coring location from sea level and the present limitations of durability design method are investigated in the paper.