• Title/Summary/Keyword: 내구성설계기준

Search Result 138, Processing Time 0.028 seconds

A Study on the Improvement of Durability Design of Underground RC Structures (RC 지하구조물의 내구성설계 개선에 관한 연구)

  • Im, Jung-Soon;Bahng, Yun-Suk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.4
    • /
    • pp.13-18
    • /
    • 2007
  • The research was performed to review the design factors which affect the durability of structures. For the study, domestic and foreign literature review were performed on various design criteria. Based on Korean standard specifications, the results showed that the durability of structure as the diameter of reinforcing steel bar becomes smaller and the distance between reinforcing bar is closer than the normal gap. The results were also presented that the minimum required bar cover is 6.6cm to obtain the durability index value. In addition, the maximum limited bar cover was 12cm considering the durability index and the change of increasing value of durability index. In case that there is no specified regulation for the bar cover thickness change, the durability life by neutralization is proportional to the thickness of bar cover.

Examining and Refining the Code for Durability Design Criteria of Concrete Carbonation (개정 콘크리트 탄산화 내구성 설계기준의 적용상 문제점 분석)

  • Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.3
    • /
    • pp.285-293
    • /
    • 2023
  • In this research, we embarked on a meticulous analysis of the challenges inherent in real-world scenarios relating to the durability design standards of engineered concrete structures and the assessment of carbonation durability in concrete guidelines. Our investigation brought to light substantial issues concerning constructability and quality assurance. The genesis of these problems is the exclusive application of prescribed strength to exterior walls, neglecting other elements to facilitate smoother licensing procedures. While this methodology aims to mitigate financial constraints in alignment with enhanced standards, it invariably invites complications. Furthermore, it is imperative to resolve the uncertainty surrounding durability evaluations by establishing a clear and definitive objective. Alongside this, actionable steps must be formulated to forestall the emergence of fissures between the floors of residential buildings, particularly apartment complexes. It is equally essential to tackle issues connected to application by devising a comprehensive management strategy for potential cracking during the phase of maintenance.

The Chloride Ion Diffusivity of Ready-Mixed Concrete Depending on Specified Compressive Strength (레디믹스트 콘크리트의 설계기준 압축강도별 염소이온 확산특성)

  • Park, Dong-Cheon;Kim, Yong-Ro
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.6
    • /
    • pp.543-550
    • /
    • 2018
  • The RC buildings which are constructed on the seaside are followed by KBC(2016) to achieve the minimization of durability damage. To control the corrosion of the reinforcing steel bar by salt attack, W/C should be under 0.4 and specified concrete strength is higher than 35MPa in the concrete/building construction standard specification. Even though it has been proved that the concrete mixed with mineral admixture such as blast furnace slag and fly ash etc. have high strength and durability in previous researches, the beneficial informations are not applied to the codes. Ready-mixed concretes which usually include the admixtures in Busan were tested to certify the salt attack durability. In the same specified concrete strength, remarkable salt attack durability was evaluated in comparison to OPC. For economical and reliable durability design, chloride ion diffusivity should be measured before applying to new building construction.

Accelerated Mission Test & Evaluation of KFP engine for Quality Assurance (KFP엔진의 품질보증을 위한 내구성시험 평가기법)

  • 김성규;김철인
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.3-3
    • /
    • 1998
  • KF-16 항공기용 F100-229 엔진 부품 중 국내에서 생산되는 부품에 대한 초도품 품질보증방법의 일환으로 내구성시험을 국내에서 수행하였다. 그동안 국내에서의 항공기 엔진산업은 사용중인 엔진의 정비 혹은 민항기 엔진 일부 부품을 기계 가공하여 납품하는 수준이었으므로 특별한 품질보증 시험이 요구되지 않았으나, KFP 사업을 시작하면서 일부 주요부품은 국내에서 직접 생산하여 KF-16 항공기용 엔진에 장착하게 되므로 완제 엔진을 조립 생산할 수 있는 능력의 확보뿐만 아니라 적절한 품질보증 대책이 요구되었다. 이에 따라 국내 생산된 완제 엔진의 조립성과 일부 단품에 대한 품질보증 확보방안으로 엔진의 개발 및 부품개량시 설계수명 및 설계규격의 만족여부를 검증하는 시험인 엔진 내구성시험(Engine Accelerated Mission Test)기법을 적용하여 1차와 2차에 걸쳐 품질보증시험을 수행하였다. 시험결과 완제 엔진의 조립성, 추진성능, 부품의 내구도 확인에 의한 품질보증 적합성 여부를 확인할 수 있었으며, 본 시험평가 기법을 통하여 시험 후 부품의 검사 및 평가방법과 기준을 제시하였고, 군용 엔진 내구성시험의 요구조건, 시험절차, 시험항목 등을 확립하였다.

  • PDF

Practical Prediction of Creep, Shrinkage and Durability of Concrete In Japan (콘크리트 크리프, 수축 및 내구성에 대한 일본의 실무예측)

  • Kwon, Seung Hee;Kang, Su Tae
    • Magazine of the Korea Institute for Structural Maintenance and Inspection
    • /
    • v.16 no.1
    • /
    • pp.90-101
    • /
    • 2012
  • 최근 일본의 설계규정(설계기준 내 재료모델)은 전 세계에서 수집된 실험 결과들을 바탕으로 개발된 것으로, 세계 최고 수준의 예측 방법으로 알려져 있다. 그럼에도 불구하고 장기간 관측된 실제 교량의 처짐은 예측결과와 많은 차이를 나타내고 있다. 이 논문에서는 콘크리트의 시간의 존적 거동에 대한 일본 설계규정의 주요 변천 과정을 소개하고, 실제 장기거동과 예측결과가 큰 차이를 보이는 원인에 대한 논의가 이루어질 것이다. 또한 내구성이 높고 경제적인 콘크리트 구조물 건설을 위한 앞으로의 연구방향이 제시될 것이다.

  • PDF

Full Scale Durability Test of Basic Trainer (기본 훈련기 실기체 내구성시험)

  • Joo, Young-Sik;Kim, Min-Sung;Park, Byung-Hoon;Shul, Chang-Won;Kim, Ho-Yeon;Jung, Jae-Kwon;Jeong, Byeong-Woo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.5
    • /
    • pp.127-133
    • /
    • 2002
  • The general requirements to achieve the structural integrity of the airframe are described in the military specification, MIL-STD-1530A. One of these requirements is the durability and damage tolerance of the airframe, which should be shown through the analysis and test based on the related specifications. This paper introduces the full scale durability test to evaluate the structural safety and durability of the basic trainer, KT-1. The test was performed according to the procedure in the military specification. The flight by flight load spectrum was developed by KT-1 fatigue load criteria and used for the durability test. The durability test had been performed for 4 service lives and was completed successfully. Therefore, it was shown that KT-1 airframe satisfied the durability requirements.

Durability Test and Test Jig Development of an Automotive Parking Lock Gear (자동차용 파킹 락 기어의 내구시험과 시험 지그 개발)

  • Mun, Hyun-Sik;Park, Sung-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.104-109
    • /
    • 2018
  • Generally, the durability of the parking lock gear is evaluated through an endurance test for the entire transmission but no test standard exists for the durability test of one part of a parking lock gear. Therefore, in this study, the durability test standards of the parking lock gear were determined autonomously, and the durability performance test was conducted. A static fracture test was carried out to determine the yield strength of the parking lock gear, and a durability test condition was set to 60 % of the yield strength. The durability test of 1,000,000 times was conducted under the given conditions using a dedicated test jig manufactured for the test. Because the jig fractured during the static fracture test, finite element analysis for the jig was carried out and the jig was re-designed. The modified jig was manufactured and the durability test was carried out based on the test standard of autonomously. The basic data on the performance and endurance limit of the parking lock gear were obtained using these tests and analyses, and the basic data will be used as fundamental materials for the design and the development of the parking lock gear.

해양환경에서의 콘크리트 보의 성능연구

  • Yang, In-Hwan;Kim, Gyeong-Cheol;Kim, Yeong-Jun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.10a
    • /
    • pp.261-263
    • /
    • 2013
  • 해양환경에서의 아연코팅철근 콘크리트 보의 휨 성능 및 균열 특성 실험을 수행하였다. 또한, 보에서 발생하는 균열 및 파괴양상을 파악하였다. 그 결과, 해양환경에서의 콘크리트 부재의 피복두께를 기존 설계기준보다 작게 적용시켜도 부재에 발생하는 염해에 대한 내구성을 확보할 수 있으며, 아연코팅 철근의 적용은 일반철근 콘크리트 보다 내구성 측면에서 유리하다고 판단된다.

  • PDF

Time Dependent Chloride Transport Evaluation of Concrete Structures Exposed to Marine Environment (해안 환경 하에 있는 콘크리트 구조물의 시간의존적 염화물침투 평가)

  • Song, Ha-Won;Pack, Seung-Woo;Ann, Ki-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.5
    • /
    • pp.585-593
    • /
    • 2007
  • This paper presents a model for durability evaluation of concrete structures exposed to marine environment, considering mainly a build-up of surface chloride $(C_s)$ as well as diffusion coefficient (D) and chloride threshold level $(C_{lim})$. In this study, time dependency of $C_s$ and D were extensively studied for more accurate evaluation of service life of concrete structures. An analytical solution to the Fick's second law was presented for prediction of chloride ingress for time varying $C_s$. For the time varying $C_s$, a refined model using a logarithm function for time dependent $C_s$ was proposed by the regression analysis, and averaging integrated values of the D with time over exposed duration were calculated and then used for prediction of the chloride ingress to consider time dependency of D. Durability design was also carried out for railway concrete structures exposed to marine environment to ensure 100 years of service life by using the proposed models along with the standard specification on durability in Korea. The proposed model was verified by the so-called performance-based durability design, which is widely used in Europe. Results show that the standard specification underestimates durability performances of concrete structures exposed to marine environment, so the cover depth design using current durability evaluation in the standard specifications is very much conservative. Therefore, it is found that utilizing proposed models considering time dependent characteristics of $C_s$ and D can evaluate service lift of concrete structures in marine environment more accurately.

A Study on the Cover Property of Offshore Reinforced Concrete Structure (내구성 해양 RC 구조물의 철근 피복적정성에 관한 연구)

  • Im, Jung-Soon;Bahng, Yun-Suk;Jo, Jae-Byung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.3 s.14
    • /
    • pp.73-81
    • /
    • 2004
  • On this study, durability decreasing element caused by salt damage was analyzed elementally and studied with the data of the inside and outside in the country. The design strength and water-cement ratio according to diffusion coefficients of chloride were applied to Fick's diffusion equation. The required over depended on environmental conditions is estimated with endurance period, and the influences on cover according to the transformation of the each parameter were investigated. In consequence, if water-cement ratio decreases and design strength increases, it shows that slowing infiltration velocity of chloride ion can decrease required cover. Especially, it is more effective to use Portland blast-furnace slag cement into high strength concrete in the splash zone environmental conditions in blocking the diffusion of chloride ion. As the result, in the case of the offshore concrete structure needed high durability, it is needed to increase cover($3cm{\sim}8cm$) than minimum standard cover(8cm) according to environmental conditions.