• Title/Summary/Keyword: 내구성능

Search Result 1,219, Processing Time 0.029 seconds

Comparative Study on Freeze-Thaw Durability of General Concrete and Pavement Concrete (일반콘크리트와 포장콘크리트의 동결융해 내구성에 대한 비교 연구)

  • Kim, Hyun-Joong;Lee, Beung-Duk;Lee, Ju-Gang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.561-564
    • /
    • 2008
  • Concrete scaling is the progressive surface deterioration of susceptible subjected to freeze-thaw cycling in the presence of moisture. Particularly, it has been recognized that chlorides present in deicing agents can significantly increase concrete surface scaling. Domestic area of most be happened chloride deicer damage. Because daily mean temperature is below 0$^{\circ}C$ from the area of domestic most. Use of deicing chemicals has been and will continue to be a major part of highway snow and ice control methods. Chloride-containing chemicals such as calcium chloride or rock salt are main deicers for the road. Extensive use of chloride deicers is, however, not only the source of substantial cost penalties due to their corrosive action and ability to deterioration roadway surface materials but also the source of environmental damages. In this study, Use of (40, 27, 21MPa) pavement concrete analyze freeze-thaw test and scaling on the chlorides present.

  • PDF

A Study on Durability Test of Check Valve for CNG Vehicles (천연가스 차량용 체크밸브의 내구성능에 관한 연구)

  • Kim, Chang-Gi;Lee, Sun-Youp;Cho, Gyu-Baek
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.15-20
    • /
    • 2009
  • The number of compressed natural gas (CNG) vehicles have increased gradually by virtue of korea government's urban air quality improvement policy since 1998. Although the use of CNG as transportation fuel gives environmental benefits, there is a possibility of huge accidents from unexpected fire. Therefore, needs for the guarantee of safety are indispensible for the reliable operation of CNG vehicles. A check valve is a safety device which prevents leakage of the pressurized fuel charged in a fuel tank. Durability of this component should be guaranteed in spite of repeated operation. This research has performed durability tests of a CNG check valve regarding the repeated usage, extreme chattering, and the effect of compressor oil.Although a check valve used for CNG vehicle satisfies validation requirements in the test results, it has been found that problem in the function of leakage prevention in a check valve could take place in the case of prolonged exposure to compressor oil.

  • PDF

Durability Evaluation of Cathode Open-type Proton Exchange Membrane Fuel Cells Stacks (Cathode 개방형 고분자연료전지 스택 내구성 평가)

  • Yoo, Donggeun;Kim, Hyeonsuck;Oh, Sohyeong;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.12-19
    • /
    • 2022
  • Cathode open-type PEMFC (Proton Exchange Membrane Fuel Cells) stacks, which are widely used in small transport-type PEMFC, have a problem with poor durability. Through the accelerated durability test of the 13-cell PEMFC stack, we tried to find the cause of the degradation of the stack and to contribute to the improvement of the durability of the cathode open stack. A hydrogen/air boundary is formed during start-up/shut-down (SU/SD) due to the structural problem of the cathode open stack in which the cathode is open to the atmosphere and it is difficult to maintain airtightness, thereby deteriorating the cathode. In this study, it was possible to evaluate the durability in a relatively short time by reducing the 54% of the initial performance by repeating SU/SD 1,800 times on the cathode open stack. After dismantling the stack, each cell was divided into two and the performance was analyzed. Overall, the anode outlet MEA, which facilitates air inflow, showed more severe electrode deterioration than the inlet MEA, confirming that the hydrogen/air boundary formation during SU/SD is the main cause of degradation.

Performance and Durability of PEMFC MEAs Fabricated by Various Methods (PEMFC MEA 제조 방법에 따른 성능 및 내구성)

  • Jeong, Jaehyeun;Song, Myunghyun;Chung, Hoibum;Na, Ilchai;Lee, Junghoon;Lee, Ho;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.52 no.5
    • /
    • pp.558-563
    • /
    • 2014
  • To study the effects of fabrication methods on the performance and durability of polymer electrolyte membrane fuel cells (PEMFCs), membrane-electrode assemblies (MEAs) were fabricated using a Dr blade method, a spray method, screen print method and screen print + spray method. The performance of single cells assembled with the prepared MEAs were initially measured and compared. Electrode accelerated stress testing (AST) involving a potentiostatic step-wave with 10 s at 0.6 V followed by 30 s at 0.9 V was applied to test durability of MEAs. Before and after 6,000cycles of the AST, I-V curves, impedance spectra, cyclic voltammograms, linear sweep voltammetry (LSV) and transmission electron microscope (TEM) were measured. Under the operating conditions, the Dr Blde MEA exhibited the highest initial performance. After electrode accelerated stress testing, screen print + spray MEA showed lowest degradation rate.

Performance Improvement of Thin Pavement Layer using Epoxy and Ceramics Composite Materials (에폭시와 세라믹스를 결합한 혼합물 이용 박층 포장공법의 성능개선)

  • Kim, Wan-Sang;Kim, Nak-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.5
    • /
    • pp.65-70
    • /
    • 2008
  • Asphalt concrete pavements are susceptible to deformation and failure compared to cement concrete pavements. Epoxy is commonly used to enhance the bonding and durability of structures. Based on this concept, an epoxy and ceramics combined mixture was developed and applied to the field to estimate the pavement performance, Laboratory and field performance tests were conducted to observe the applicability of epoxy and ceramics composite materials compared to the conventional one. In this research, the epoxy and ceramics composite mixturewas used in two ways. 7 mm and 15 mm of thin surface layers using the mixture were constructed on cement and asphalt concrete pavements, respectively, after surface treatment. 12 months of field performance surveys were conducted to observe the resistances to the crack and deformation. According to the field performance tests, epoxy and ceramics combined mixture showed better bonding and field performances than the conventional one.

Development and Application of Anti-Corrosive Steel Using Electro-Deposition of Sea Water (2)- Evaluation of Application Rebar with Electro-Deposition Using Sea Water (해수전착 코팅을 이용한 내부식성 철근의 개발 및 적용성에 대한 연구 (2) -해수전착된 구조용 철근의 적용성 평가)

  • Kwon, Seung Jun;Lee, Sang Min;Park, Sang Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.155-162
    • /
    • 2012
  • When RC (Reinforced Concrete) structures are exposed to sea water, steel corrosion can occur and this leads a degradation of structural performance. Referring the electro-deposition system with sea water from the 1st step research, durability and structural performance are evaluated in coated steel and RC members containing it in the 2nd research. In the durability performance test, Half Cell Potential test is performed and the coated steel is evaluated to have the high resistance to corrosion, which shows only 35% of corrosion velocity in normal (bare) steel. In the structural performance test, tensile strength, adhesive strength, and flexural/shear in RC member are performed. For the electro-deposit coated steel, increasing ratios of 3.2% and 8.8% are evaluated in the test of tensile strength and adhesive strength, respectively. For the structural test in RC member, there is no big difference between RC members with coated and non-coated steel in ultimate load and failure pattern It is evaluated that the chemical compound with $CaCO_3$ and $Mg(OH)_2$ from electro-deposition causes slightly increased structural performance. The electro-deposit coated steel can be more widely applied after performance verification from several tests like fatigue, resistance to impact, and long term-submerging test.

Effect of Influent Gas on Mechanical Acceleration Durability Test of PEMFC Polymer Membrane (PEMFC 고분자막의 기계적 가속 내구 평가 과정에서 유입 가스의 영향)

  • Oh, Sohyeong;Hwang, Byungchan;Jung, Sunggi;Jeong, Jihong;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.60 no.3
    • /
    • pp.321-326
    • /
    • 2022
  • As the thickness of the polymer membrane of PEMFC(Proton Exchange Membrane Fuel Cells) is getting thinner for PEMFC performance and price reduction, research on improving durability has become more important. In the durability evaluation of membranes, the mechanical durability evaluation time is more than twice that of the chemical durability evaluation time, so it is necessary to select the durability evaluation conditions well. In this study, we tried to check how much the mechanical durability evaluation time changes when there is a difference in the inflow gas type and flow rate in the mechanical durability evaluation protocol (Wet/Dry). When nitrogen was used at a flow rate of 2,000 mL/min, the evaluation time increased by 1.25 times compared to when air was used. An increase in the degradation rate of the electrode Pt was the main factor when air was used. When the flow rate was reduced to 800 mL/min, the air and nitrogen evaluation times increased by 1.5 times and 1.2 times, respectively.

Development of techniques for evaluating residual life of water pipes based on pipe deterioration evaluation results (관로 노후도 평가결과를 이용한 상수도 관로의 잔존수명 평가 기법의 개발)

  • Park, Suwan;Kim, Kimin
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.10
    • /
    • pp.673-679
    • /
    • 2017
  • In this paper a method for estimating the 'service life' and 'residual life' of a water pipe based on the Water Pipe Network Performance Evaluation(WPNPE) results of Water Supply Technical Diagnosis was developed for efficient maintenance of water pipes. The residual life of a pipe was defined as the difference between the service life and elapsed time since installation. The service life was defined as the time when a pipe reaches the reference score for determining deteriorated pipes that was used in the WPNPE. The pipe evaluation criteria and deterioration scores used in the WPNPE for the case study area were considered as independent variables in the multiple regression model for estimating the service life and residual life of the pipes in the area. To estimate the service life for the pipes the reference scores for determining deteriorated pipes were used as the values of the variables that represent the deterioration scores in the constructed regression models. Subsequently, the statistics of the service life and residual life of the pipes in the case study area were presented and analyzed in comparison with the service life defined by the Local Public Enterprizes Act.