• Title/Summary/Keyword: 난방 시간

Search Result 138, Processing Time 0.024 seconds

Variation of Indoor Air Temperature by using Hot Water Piping in Greenhouse (온수배관에 의한 온실 내부의 온도변화)

  • Yoon, Yong-Cheol;Shin, Yik-Soo;Bae, Seoung-Beom;Kim, Hyeon-Tae;Choi, Jin-Sik;Suh, Won-Myung
    • Journal of agriculture & life science
    • /
    • v.46 no.2
    • /
    • pp.179-190
    • /
    • 2012
  • This study was performed to obtain a heat saving effect and enhance the efficiency of a greenhouse by using a hot water piping in order to minimize the operating costs of a greenhouse as oil prices continue to rise. This method also reduces the likelihood of accidents caused by snowdrifts in regions with heavy snowfall. In general, the experimental plot was $2.0{\sim}6.0^{\circ}C$ higher than the control plot. When the skylight felt was opened, the minimum temperature was in the range of $3.0{\sim}12.0^{\circ}C$. Therefore, we judged that damage caused by snowdrifts may be prevented partly by active heating. The temperature difference inside of the greenhouse by height was insignificant. The maximum heating load of the greenhouse according to crop was respectively about $37,000kcal{\cdot}h^{-1}$ and $41,700kcal{\cdot}h^{-1}$. During the experiment, the heat value of each designed temperature in the range of the minimum ambient temperature $-11.9{\sim}4.0^{\circ}C$ was about 95,000~322,000 kcal and it was in the range of $6,050{\sim}20,900kcal{\cdot}h^{-1}$. If it is compared with the maximum heating load, it can be shown that about 15~56% of the heating energy can be supplied. The total heat value and the amount of power consumption were 2,629,025 kcal and 677.3 kWh respectively during the experiment. If it is heated with diesel, a fossil fuel, the consumption during the experiment was 291 L and the cost was 331,700won. Total cost of using electric power was about 24,400 won and it is shown that it is about 7.5% of the cost of diesel consumption. Also, if the total amount of power consumption is converted into energy, it is approximately 582,200 kcal and the energy was just about 22% of the total heat value.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF

Performance Improvement of an Air Source Heat Pump by Storage of Surplus Solar Energy in Greenhouse (온실 내 잉여 태양열을 이용한 공기열원 히트펌프 성능향상)

  • Kwon, Jin Kyung;Kang, Geum Chun;Moon, Jong Pil;Kang, Youn Ku;Kim, Chung Kil;Lee, Su Jang
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.328-334
    • /
    • 2013
  • A greenhouse heating system to improve heat pump performance using inside and outside air of greenhouse as a heat source selectively and cut $CO_2$ enrichment costs by delay of greenhouse ventilation was developed. In this system, thermal storage modes divided into inside circulation mode using surplus solar energy and outside circulation mode using outside air heat. The thermal storage modes were designed to be switched mutually according to inside greenhouse temperature and six temperature values were input to control the heat pump operating, thermal storage mode switching and greenhouse heating automatically. Operating characteristics of this system were tested in a plastic greenhouse of non-ventilation condition. The results of test showed that the inside circulation mode began at about 11:00 and lasted for about 210 minutes and inside greenhouse temperature was maintained between $20{\sim}28^{\circ}C$ in spite of non-ventilation. System heating COP of the inside circulation mode in the daytime was 3.35, which was 36% and 25% higher than that of the outside circulation modes in the nighttime and daytime respectively.

A Simulation of Temperature Control of Greenhouse with Hot-Water Heating System (온수난방시스템 온실의 온도제어 시뮬레이션)

  • 정태상;하종규;민영봉
    • Journal of Bio-Environment Control
    • /
    • v.8 no.3
    • /
    • pp.152-163
    • /
    • 1999
  • It is required to analyze the controlled response of air temperature in greenhouse according to control techniques for precise control. In this study, a mathematical model was established for air heating of greenhouse with hot-water heating system The parameters of the model were decided by regression analysis using reference data measured at the greenhouse being heated In the simulation for the digital control of air temperature in the greenhouse, the mathematical model to evaluate the control performances was used. Tested control methods were ON-OFF contpol, p control, rl control and PID control. The mathematical model represented by inside air temperature ( T$_{i}$), hot-water temperature (T$_{w}$) in heating pipe and outside air temperature (T$_{o}$) was expressed as a following discrete time equation ; T$_{i}$($textsc{k}$+1)= 0.851.T$_{i}$($textsc{k}$)+0.055.T$_{w}$($textsc{k}$)+0.094.T$_{o}$($textsc{k}$) Control simulations for various control methods showed the settling time, the overshoot and the steady state nor as follows; infinite time, 3.5$0^{\circ}C$, 3.5$0^{\circ}C$ for ON-OFF control : 30min 2.37$^{\circ}C$, 0.51$^{\circ}C$ for P control; 21min, 0.0$0^{\circ}C$, 0.23$^{\circ}C$ for PI control; 18min 0.0$0^{\circ}C$, 0.23$^{\circ}C$ for PID control, respectively. PI and PID controls appeared to be optimal control methods. There was no effect of differential gain on the heating process but much effect of integral gain on it.on it.

  • PDF

Analysis of Outdoor Design Temperatures for Heating and Cooling Greenhouses Based on Annual Percentiles (연간 백분위 방식에 의한 온실 냉난방 설계기온의 분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.27 no.3
    • /
    • pp.269-275
    • /
    • 2018
  • In order to establish the criterion for analyzing outdoor weather conditions in the greenhouse heating and cooling system design, we analyzed heating and cooling design outdoor temperatures by the annual percentile method and compared with design outdoor temperatures by the existing seasonal percentile method. In the annual percentile method, 0.4%, 1% and 2% of the total 8,760 hours per year are presented as cooling design outdoor temperatures and 99.6% and 99% as heating design outdoor temperatures. When the annual percentile method was adopted, heating design outdoor temperatures increased by 6.7 to 9.6% compared with the seasonal percentile method, and cooling design outdoor temperatures decreased by 0.6 to 1.1%. The maximum heating load in the same greenhouse condition decreased by 3.0 to 3.6% when the annual percentile method was adopted, but the effect on the maximum cooling load was insignificant. Therefore, it is necessary to consider the change of heating design outdoor temperatures to the annual percentile method, but it is not necessary to change the cooling design outdoor temperatures since there is little difference between the two methods.

A Study on performance of geothermal heatpump using domestic supply water source and geothermal source during winter (상수도열원과 지열원을 이용한 동절기 지열히트펌프 성능평가에 대한 연구)

  • Lee, Byoungdoo;Lee, Sejin;Lee, Daewoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.194.1-194.1
    • /
    • 2011
  • 본 연구에서는 지열히트펌프 시스템의 열원으로써 지열이외에 건축물의 미활용 에너지라고 할 수 있는 상수도의 에너지를 활용하여 지중열교환기의 천공길이를 줄이는 것이 주요 목적이며, 또한 건물의 미활용에너지를 냉난방에너지원으로써 이용 가능한 것을 보여주는 것에 있다. 실험은 4인 가족기준으로 3RT 용량의 히트펌프를 설치하고 인당 평균 177 liter/day 기준으로 하루에 약 710 liter/day의 물을 사용하는 것으로 가정하였다(환경부 2007년 상수도 통계값). 시간당 가정내에서 사용하는 물량은 일정하지 않아 일일 8시간 사용하는 것으로 하여 약 1.5 LPM 으로 실험하였다. 저수조의 크기 및 지열 히트펌프의 열원으로써 사용가능한 열량을 계산하기 위해 CFD 시물레이션을 수행하였다. CFD의 결과 상수도를 급수하기 위한 저수조의 크기는 $2m^3$로 결정하였으며 이때 열원으로써 사용가능한 열량은 약 0.7RT였다. 48시간의 실험기간 동안 저수조를 통해 얻은 열원은 0.6RT 였으며 100m의 지중열교환기를 통해 얻은 열원은 2RT 였다. 히트펌프 자체의 난방 COP는 평균 4.2를 나타내었으며 펌프등의 소비전력을 포함한 System COP는 4.0 나타내었다. 이번 연구를 통해 건물의 미활용에너지인 저수조의 물을 이용하여 지열히트펌프의 열원으로써 이용 가능하며 기존의 지열히트펌프 시스템대비 천공길이 단축, 시공비 저감이 가능한 것을 볼 수 있었다.

  • PDF

Estimation of Personal Exposure on Nitrogen Dioxide Using Time Activity - Comparative Study between Seoul, Korea and Brisbane, Australia - (시간활동도를 이용한 이산화질소 개인노출 예측 - 한국의 서울과 호주의 브리스베인의 비교 연구 -)

  • 양원호;이기영;손현석;정문호
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.2
    • /
    • pp.10-17
    • /
    • 2000
  • 현대 생활에서 대부분의 사람들은 90%이상을 실내(가정, 일반사무실, 실내작업장, 공공건물, 지하시설물, 상가, 음식점, 자동차, 지하철 등)에서 생활하기 때문에 실내공기질(indoor air quality)은 개인이 오염물질에 노출되는 주요한 요인이다. 이산화질소($NO_2$)는 고온의 연소과정에서 발생되는 부산물로써 차량, 발전소와 산업장 등에서 발생되고 있다. 실내에서 이산화질소의 농도는 가스레인지, 케로센(kerosene) 난방기, 흡연에 주로 영향을 받는다. $NO_2$는 호흡기 증상과 관련된 각종 질환을 유발시키는 것으로 보고되고 있다. 본 연구는 한국의 서울에서 직장인 95명의 시간활동도가 조사되었으며, 호주 브리스베인에서 직장인 57명의 시간활동도와 동시에 각 가정의 실내.외 및 직장의 $NO_2$ 농도를 측정하였다. 또한 개인 $NO_2$ 노출을 예상하여 각 도시의 빈도분포를 예상하였다. 본 연구의 결과를 보면 다음과 같다. 1. 서울의 95명의 직장인들은 실내에서 약 83.8%의 시간을 보냈으며, 브리스베인의 57명의 직장인들은 실내에서 약 88.3%의 시간을 보냈다. 2. 브리스베인에서 측정된 실내의 NO2 평균농도는 10.5ppb(${\pm}5.6$), 실외의 NO2 평균농도는 14.5ppb(${\pm}5.8$), 직장에서의 $NO_2$ 평균농도는 18.2ppb(${\pm}5.0$)였다. 개인의 $NO_2$ 노출은 평균 15.0ppb(${\pm}5.2$)였다. 개인의 $NO_2$ 노출은 실외의 $NO_2$ 농도(r=0.42)보다 실내의 $NO_2$ 농도(r=0.42)보다 실내의 NO2 농도(r=0.49)에 상관성이 더 높았다. 3. 시간 가중치 모델을 이용한 개인 $NO_2$ 노출은 측정된 개인 NO2 노출과 통계학적으로 상관성을 가지고 있었다(r=0.58). 예측된 개인 $NO_2$ 노출은 측정된 $NO_2$ 노출보다 낮게 나타났으며, 이것은 출퇴근 등에 의한 교통의 이동에 따른 노출 때문인 것으로 생각되었다. 4. $NO_2$ 농도 분포를 log-normal 분포, 시간활동도를 Normal 분포로 가정하고 Monte-Carlo 시뮬레이션을 했을 때 서울의 직장인의 개인 노출은 평균 36.7ppb(${\pm}10.9$)였으며, 브리스베인의 직장인의 개인 노출은 평균 13.7ppb(${\pm}4.1$)였다.

  • PDF

Assessment of the Effect of Dimethyl Ether (DME) Combustion on Lettuce and Chinese Cabbage Growth in Greenhouse (온실에서 상추와 배추를 이용한 DME 원료 난방 효율분석)

  • Basak, Jayanta Kumar;Qasim, Waqas;Khan, Fawad;Okyere, Frank Gyan;Lee, Yongjin;Arulmozhi, Elanchezhian;Park, Jihoon;Cho, Wonjun;Kim, Hyeon Tae
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.293-301
    • /
    • 2019
  • The experiment was conducted to determine the performance of DME combustion gas when used as a fuel for DME burner for raising temperature and $CO_2$ concentration in greenhouse and also to examine its effects on chlorophyll content, and fresh and dry weight of lettuce and Chinese cabbage. DME-1 and DME-2 treatments consisted of average DME flow quantity in duct were $17.4m^3min^{-1}$ and $10.2m^3min^{-1}$ respectively to greenhouse-1 and greenhouse-2 and no DME gas was supplied to greenhouse-3 which was left as control (DME-3). DME supply times were $0.5hr\;day^{-1}$, $1hr\;day^{-1}$, $1:30hrs\;day^{-1}$ and $2hrs\;day^{-1}$ on week 1, 2, 3, and 4 respectively. Chlorophyll content and fresh and dry weight of lettuce and Chinese cabbage were measured for each treatment and analyzed through analysis of variance with a significance level of P<0.05. The result of the study showed that $CO_2$ concentration increased up to 265% and 174% and the level of temperature elevated $4.8^{\circ}C$ and $3.1^{\circ}C$ in greenhouse-1 and 2, respectively as compared to greenhouse-3 due to application of DME combustion gas. Although, the same crop management practices were provided in greenhouse-1, 2 and 3 at a same rate, the highest change (p<0.05) of chlorophyll content, fresh weight and dry weight were found from the DME-1 treatment, followed by DME-2. As a result, DME combustion gas that raised the level of temperature and $CO_2$ concentration in the greenhouse-1 and greenhouse-2, might have an effect on growth of lettuce and Chinese cabbage. At end of experiment, the highest fresh and dry weight of lettuce and Chinese cabbage were measured in greenhouse-1 and followed by greenhouse-2. Similarly chlorophyll content of greenhouse-1 and greenhouse-2 were more compared to greenhouse-3. In general, DME was not producing any harmful gas during its combustion period, therefore it can be used as an alternative to conventional fuel such as diesel and liquefied petroleum gas (LPG) for both heating and $CO_2$ supply in winter season. Moreover, endorsed quantify of DME combustion gas for a specified crop can be applied to greenhouse to improve the plant growth and enhance yield.

Feasibility Study on a Defrost Control Method by Using a Photoelectric Sensors (광센서를 이용한 제상제어 방법에 대한 타당성 검토)

  • Jeon, Chang-Duk;Kim, Dong-Seon;Lee, Seung-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3389-3395
    • /
    • 2014
  • Conventional methods, such as the clock time control method and temperature difference control method, for defrost control often encounter mal-defrost and a waste of energy. Therefore, a more efficient method is needed to control defrosting precisely. A photoelectric sensor unit consisting of an emitter and a collector was installed in the front of outdoor heat exchanger. Accurate defrost control was performed by monitoring and using the change in output voltage according to the presence of frost. In this study, experiments were performed to determine if the performance and characteristic curves obtained using the clock time control method can be reproduced using a photoelectric sensor under the heating and defrosting capacity test condition described at KS C 9306. The output voltage of the phototransistor (receiver) and heating capacity, power consumption, and surface temperature of the outdoor heat exchanger, were compared. The results showed that photoelectric sensors can be used as a defrost control method. On-off control timing of the clock time defrosting method was in good agreement with those predicted by the output voltage of the photoelectric sensor.

A Study on the Release Characteristics of VOCs from Heat Recovery Ventilation System (폐열회수형 환기장치의 휘발성유기화함물 배출 특성에 관한 연구)

  • Kwak, Kyung-Min;Bai, Cheol-Ho;Kim, Jee-Yong;Chu, Euy-Sung
    • Clean Technology
    • /
    • v.13 no.4
    • /
    • pp.281-286
    • /
    • 2007
  • VOCs from the heat recovery ventilation system (total heat exchanger) are measured in this study. Two different types of element (L and M type) from heat recovery ventilating system are tested to study the intial release characteristics of VOCs under KS cooling and heating standard conditions. VOCs are measured for the various flow rates and different operating times. Considering errors in the test method and the measuring instrument, the tested heat recovery ventilating systems was found to release 6 major VOCs, such as acetic acid, 2-butanone (MEK), 2-(methylthio )ethylamine, toluene, styrene, and x-acids (Ion 57). The concentrations of released VOCs are not quite much affected by operating conditions. The results show much larger VOCs concentrations in the cooling mode than in the heating mode, due to the high operating temperatures.