• 제목/요약/키워드: 난방제어

검색결과 194건 처리시간 0.021초

온돌 난방에 대한 동적 시뮬레이션 및 분석 (Method and Analysis of Dynamic Simulation for Ondol Heating)

  • 홍희기;김시환
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.375-382
    • /
    • 2010
  • Ondol heating, a kind of radiant floor heating, is a main method used in housing units in Korea. Building energy simulation including ondol and relevant facilities has not been performed due to its complexity. For evaluating energy consumption and indoor temperature variation, a new method should be proposed. At the present work, a dynamic simulation on ondol heating was tried by combining TRNSYS and EES. Characteristic functions for a pump, hot water coils and a gas boiler were simultaneously solved by EES, and calculated flow rates and supply temperature of hot water were provided as inputs of the active layer of TYPE 56 in TRNSYS. The results by the simulation on a typical housing unit in Korea shows a good trend in a viewpoint of actual behavior of ondol heating.

바닥복사난방의 실별제어시스템에 관한 열성능 평가 (An Evaluation on the Thermal Performance of the Room Control System for Radiant Floor Heating)

  • 석호태;김오봉;조영흠;김광우;여명석
    • 한국주거학회논문집
    • /
    • 제14권5호
    • /
    • pp.75-82
    • /
    • 2003
  • In this study, the thermal performance of the room control system is analyzed in terms of control performance, potential for coil expansion and energy consumption through experiments comparing the individual room control system and an existing system. The results of this study show that the existing system is not able to supply design water flow rate and does not accurately maintain the set point temperature in each room. However, the individual room control system can set a room air temperature for each room, for it is able to supply design water flow and accurately control the set point temperature in each room and can reduce the energy consumption compared to the existing system. Moreover, the individual room control system can reduce the number of coil division zone and facilitates the construction process, because it can extend the length of the coil division.

외기온도 예측 및 보상제어가 난방시스템의 에너지 소비량에 미치는 영향 (The Effects of Prediction and Reset Control of Outdoor Air Temperature on Energy Consumption for Central Heating System)

  • 안병천;홍성석
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권4호
    • /
    • pp.8-14
    • /
    • 2016
  • In this study, the effects of prediction and reset control of outdoor air temperature on energy consumption for central heating system are researched by using TRNSYS program package, and the control performances with the suggested methods of prediction and reset control of outdoor air temperature are compared with the existing ones. As a result, the value of coefficient of determination $R^2$ for the predicted outdoor temperatures is improved and the suggested control method shows maximum 21.8% energy saving in comparison with existing control ones.

바닥 복사난방 시스템의 실내온도 제어방안에 관한 시뮬레이션 연구 (Simulation Study for Control Strategies of Indoor Air Temperature in Floor Radiant Heating System)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권4호
    • /
    • pp.21-26
    • /
    • 2016
  • In this study, the control strategies of indoor air temperature in floor radiant heating system were researched by computer simulation. The temperature difference based time control method using the difference of indoor set temperature and indoor temperature is compared with the existing On-Off control one for heating control performances. As a result, the temperature difference based time control method shows better thermal environmental characteristics in case of selected operational conditions in comparison with existing control one.

중앙난방시스템의 온라인 최적제어기법에 관한 연구 (On-line Optimal Control Technology for Central Heating System)

  • 안병천;최상곤;조성환
    • 설비공학논문집
    • /
    • 제17권2호
    • /
    • pp.140-146
    • /
    • 2005
  • The on-line optimal control algorithm for central heating system has been researched for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as indoor heating load and outdoor temperature variation. This study has been done by using TRNSYS Program in order to analyze the central heating system. The optimal control algorithm shows good energy Performances in comparison with the conventional one.

간헐난방주택에 대한 외기온도 예측제어 적용 연구 (Application of the Outdoor Air Temperature Prediction Control for Intermittent Heating Residences)

  • 태춘섭;조성환;이충구
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.682-691
    • /
    • 2001
  • Most of radiant floor heating systems are operated in the intermittent heating mode in Korea. The application possibility of predictive suboptimal control for Koran residential house was investigated by computer simulation and experiment. For this study, TRNSYS program was used and an experimental facility consisting of tow rooms ($3\times4.4\times2.8 m$) identical in construction was built. The facility enabled simultaneous comparison of two different control method. And real multi residential hose was investigated. Results showed that outdoor air temperature prediction control was superior to the conventional control for radiant floor heating system operated in the intermittent heating mode. New control system resulted in good thermal environment and les energy consumption.

  • PDF

온수분배기용 유량제어밸브의 개발 (Development of Flow Control Valves for Hot Water Distribution Manifolds)

  • 권우철;윤준용;유선학
    • 한국유체기계학회 논문집
    • /
    • 제13권4호
    • /
    • pp.11-17
    • /
    • 2010
  • The developed control valves, installed on the hot water distribution manifolds for the floor heating system, consist of the balancing valves and the shut-off valves. The balancing valve was designed to improve the flow control performance and to reduce the noise emitted from the valve by modification of the general V port. The port of the shut-off valve was designed with two ceramic plates, working by rotating upper plate, to improve the duration and to reduce the noise. For the evaluation of the new valves, the flow rate was measured and noise level test was carried out. The test results showed that the error of the flow rate accuracy test for the flow balance of each manifold circuit was less than ${\pm}3%$ and the noise level was less than 35 dB(A).

온수난방시스템 온실의 온도제어 시뮬레이션 (Temperature Control Simulation for Greenhouse with Pipe Heating System)

  • 민영봉;정태상;하종규
    • 한국생물환경조절학회:학술대회논문집
    • /
    • 한국생물환경조절학회 1998년도 임시총회 및 학술논문발표요지
    • /
    • pp.5-10
    • /
    • 1998
  • 최근 온실에 온수 보일러를 설치하여 실내를 가온하는 시스템이 많이 도입되고 있다. 이들 장치들은 설정된 실내온도를 맞추기 위한 온도 제어장치가 부가되어 있지만, 대부분 ON-OFF제어 시스템을 구성하고 있기 때문에 온도 진폭의 현상이 발생하여 온도 제어 정밀성이 떨어지고 에너지소비도 많다. 이 문제점을 해결하기 위하여는 보일러 온수저장조와 온설 내 방열관 사이에 삼방변을 설치하고 설정온도, 실내온도 및 외기온을 비교하여 삼방변의 위치를 조절하여야 한다. (중략)

  • PDF

긴 지연시간을 갖는 온수난방 제어시스템의 디지틀 가변구조제어 (Digital variable structure control of a hot-water heating control system with long dead time)

  • 안병천;장효환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.232-237
    • /
    • 1991
  • Digital Variable Structure Controller(DVSC) is proposed to control variable speed recirculating pump for hot-water heating control system. In this study, nonlinear sliding line is used beyond output error boundary layer and PID sliding line is used within the layer. For long dead time compensation, constraint is added to Smith predictor algorithm. Steady state error is eliminated by using the proposed sliding line in spite of heating load change. By decreasing sampling time, good sliding motion is yielded but system output noise bv flow dynamics is amplified.

  • PDF

애플망고 농가의 에너지-믹스 하이브리드 스마트 팜에 대한 연구 (The Study on Smart Farm of Apple Mango with Energy-mix Hybrid)

  • 손재환;이승용;한창우;나규동;하유신
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2017년도 춘계공동학술대회
    • /
    • pp.155-155
    • /
    • 2017
  • 최근 애플망고 스마트 농가에 에너지 사용량이 증가됨에 따라 에너지 절감을 위한 대책들과 화석연료를 대체하는 다양한 신재생에너지 도입에 대한 요구들이 늘고있다. 본 연구에서는 애플망고 스마트 농가에 여러 에너지원들을 혼합하여 사용할 수 있도록 실증시험 모델을 구축하고 운영함으로써 그 효용성을 검토하고자 하였다. 우선 애플망고 특성을 고려한 비닐온실의 최대 냉난방부하량과 에너지모델을 분석하여 신재생 에너지원들의 혼합 및 기존 공조설비와의 연계를 계산하였다. 애플망고 시험 농지로는 재배에 적합한 제주도 서귀포를 선정하였으며, 기존의 경유 난방기를 사용하는 비교시험 하우스, 기존의 경유와 태양광, 지하 공기 히트펌프 난방기를 혼합하여 사용하는 실증시험 하우스, 경유와 지하공기 히트펌프 난방기를 사용하는 대조시험 하우스를 10~11월 두 달간 운영하여 그 결과들을 평가하였다. 온실 내외부에 온도, 습도, CO2를 측정할 수 있는 6점의 센서부들을 설치하였고, 적산 전력계와 유량계를 설치하여 데이터를 수집하였으며, 모든 시험 데이터는 모바일 원격으로 제어 및 모니터링이 가능하도록 구성하였다. 시험 결과, 각 하우스들에서 수확한 과실의 수량과 품질은 유사하게 평가되었지만, 실증시험 하우스의 난방비가 비교시험 하우스보다 절감되었다. 하지만 실증시험 하우스의 경우 높은 시설유지비로 인해 이를 고려한 사용료는 비교시험 하우스보다 더 비싸게 평가되었다. 본 연구를 통해 생산된 잉여전력을 매전할 때 이로 인한 이용비는 비교시험 하우스보다 더 경제적임을 확인할 수 있었다. 또한 기존의 경유와 지하공기 히트펌프 난방기를 혼합한 대조시험 하우스의 난방비용이 경제성에서 더 유리함을 알 수 있었다. 따라서 본 연구를 통해 애플망고 스마트 농가에 적합한 에너지-믹스 모델을 구축할 수 있었으며, 다양한 신재생에너지들의 효용성들을 검토할 수 있었다.

  • PDF