Energy Consumption Patterns for Various Building Types in Taejon (대전지역의 건물별 에너지 소비패턴에 대한 실태조사)

  • Kim, B.S.;Kim, Y.D.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.41-50
    • /
    • 1998
  • The purpose of this study is to analyze the energy consumption status for various building types in Taejon. 35 sample buildings were classified into 8 building types, i.e., sports center & swimming pools, hotels, telecommunication exchange service facility, hospitals, research laboratories, department stores, exhibition galleries, universities. According to analyses, energy consumption patterns varies significantly for each building type. Sports centers consumes highest rate(689 $Mcal/sqm{\cdot}yr$) and universities lowest rate(86 $Mcal/sqm{\cdot}yr$) among selected building types.

  • PDF

Numerical Study on Thermal Performances of Multi Heat Source Heating System Using Butane for Electric Vehicle (전기자동차용 부탄 연료 복합열원 히팅시스템의 열적 성능에 관한 수치적 연구)

  • Bang, You-Ma;Seo, Jae-Hyeong;Patil, Mahesh Suresh;Cho, Chong-Pyo;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.725-731
    • /
    • 2016
  • This study numerically investigates the thermal performance of a 2.0-kW butane-based combustion heating system for an electric vehicle under cold conditions. The system is used for cabin space heating and coolant-based battery thermal management. ANSYS CFX 17 software was used for parametric analysis. The mass flow rates of cold air and coolant were varied, and their effects were compared. The numerical results were validated with theoretical studies, which showed an error of 0.15%. As the outside air mass flow rates were increased to 0.005, 0.01, and 0.015 kg/s, the cabin supply air temperature decreased continuously while the coolant outlet temperature increased. When the coolant mass flow rates were increased to 0.005, 0.01 and 0.015 kg/s, the air temperature increased while the coolant outlet temperatures decreased. The optimal mass flow rates are discussed in a consideration of the requirements for high cabin heating capacity and efficient battery thermal management.

Development of Numerical Model for Estimation of the Nutrient Solution Cooling Load in Hydroponic Culture (수경온실의 양액냉각부하 산정을 위한 수치모델 개발)

  • 남상운;김문기;손정익
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1993.10a
    • /
    • pp.11-12
    • /
    • 1993
  • 여름철 온실의 수경재배를 위해서는 양액의 냉각은 필수적이다. 이와 같은 양액냉각을 적절히 실행하기 위해서는 먼저 시설내의 환경예측에 의한 양액의 냉각부하 산정 및 냉각부하에 따른 설비용량 결정이 필요하다. 그동안 국내외적으로 온실의 환경예측을 위한 모델들은 많이 개발되어 있지만 대부분이 토경재배를 대상으로 온실의 변화나 난방효율의 예측을 목적으로 하고 있으며, 수경재배 온실 더우기 양액 냉각을 취급하는 경우는 찾아보기 힘들다. (중략)

  • PDF

신형안전로 소개

  • 최영상
    • Journal of the KSME
    • /
    • v.29 no.1
    • /
    • pp.40-47
    • /
    • 1989
  • 신형안전로 개발의 필요성을 설비개발이라는 관점에서 우리가 해결해야 할 과제로 요약하면 첫 째는 설계개념이다. 즉 어떠한 설계개념을 채택하여야만 설비의 단순화가 가능하며 중소형이 면서도 경제성 확보가 가능할 것인가 하는 점이며, 둘째는 이러한 새로운 개념은 과연 원전의 안전성이 혁신적으로 개선된 것이며, 어디에나 용이하게 건설이 가능토록 부지요건이 완화된 것이며, 전문가가 아닌 사람도 용이하게 운전가능토록 준 무인운전 수준의 편의성 확보가 가능 한가 하는 점이다. 셋째는 극히 소용량인 지역난방 원자로에서부터 대용량 발전 설비에 이르 기까지의 연계 개발 계획으로서 수요처별 수요 적응 특성 반영과 Modular Type 또는 기타의 방법으로 용이하게 용량을 확장할 수 있는 방법을 강구하는 문제이다.

  • PDF

A Study on the Development of the Optimal Capacity Estimation Algorithm of Intergrated Energy Facilities Based on Operating Conditions (운용상태를 고려한 집단에너지설비의 최적용량 산정 알고리즘의 개발에 관한 연구)

  • Kim, Chang Sik;Song, Myung Ho;Yeom, Jee hoon;Shin, Jungyull
    • Journal of Energy Engineering
    • /
    • v.28 no.4
    • /
    • pp.94-102
    • /
    • 2019
  • The purpose of this study is to propose a method for optimizing heat generation facilities to maximize revenue by investigating their operational status during times of maximum heat demand for district heating. Based on the derived result, this study also proposes a method for determining a given power plant's optimal equipment, such as combined heat and power plant(CHP), peak load boilers (PLB), heat accumulators, and so on, depending on heat demand and facility capacities. It also offers a guide for how to operate facilities more economically by considering the operational status of district heating companies.

신형원자로로서의 일체형 가압경수로 설계특성 분석

  • 김용완;이두정;장문희
    • Nuclear Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.269-279
    • /
    • 1995
  • 가압경수로에서 증기발생기와 같은 주기기를 원자로 내부에 위치하도록 설계한 원자로를 일체형 원자로라고 분류하며, 기존 상용원자로와 같이 모든 주기기가 별도의 압력용기로 설계되어 배관계통에 의해 원자로 외부에 순환회로를 갖는 형태의 원자로를 분리형원자로라고 한다. 최근에 개발되고 있는 한 부류의 신형원자로에서는 원자로 및 계통의 단순성 추구와 계통의 높은 신뢰성으로 안전성 향상을 위해 동력원 사용 등의 능동적 안전개념 보다는 자연현상을 이용하는 피동안전개념이 널리 도입되고 있다. 본보고서에서는 이러한 신형원자로의 노형으로서 일체형원자로의 특성을 전통적인 분리형원자로와 비교, 분석, 평가하였다. 일체형원자로의 가장 큰 장점은 모든 주기기가 단일 압력용기 내에 위치하므로 일차계통이 매우 단순하고 대구경 배관이 없기때문에 대형 냉각재 상실사고가 근본적으로 방지되어 안전계통이 매우 단순하다는 것이다. 이 외에도 일체형원자로는 대단히 많은 일차냉각재 용량, 매우 큰 가압기 용량및 긴 운전원 조치시간등의 설계특성을 보유하고 있어 안전성이 탁월하다는 장점을 지니고 있다. 그러나, 일체형원자로는 모든 주기기가 단일 압력용기 내에 설치되므로 대형 원자로 용기가 요구되며, 원자로 압력용기의 제작성 및 운송 능력이 원자로의 용량을 제한하는 주된 요인이 된다. 일체형원자로의 활용으로 열병합 발전, 지역난방 및 선박용 원자로등의 중소형 원자로에 매우 적합하다고 판단되며, 뛰어난 안전성으로 인하여 사회적 수용성 이 강조되는 상용발전로로서도 적합한 노형이 될 수 있을 것으로 분석되었다.

  • PDF

A Study on An Integrated GEO/TES with Geothermal Heat Exchanger and Thermal Ice Storage (지중열 교환기와 빙축열조(Thermal Ice Storage)를 연계시킨 통합 지중열-빙축열조 시스템(Integrated GEO/TES))

  • Lohrenz ED.;Hahn Jeongsang;Han Hyuk Sang;Hahn Chan;Kim Hyoung Soo
    • Economic and Environmental Geology
    • /
    • v.38 no.6 s.175
    • /
    • pp.717-729
    • /
    • 2005
  • Peak cooling load of large buildings is generally greater than their peak heating load. Internal and solar heat gains are used fur selection of adquate equipment in large building in cold winter climate like Canada and even Korea. The cost of geothermal heat exchanger to meet the cooling loads can increase the initial cost of ground source heat pump system to the extend less costly conventional system often chosen. Thermal ice storage system has been used for many years in Korea to reduce chiller capacity and shift Peak electrical time and demand. A distribution system designed to take advantage of heat extracted from the ice, and use of geothermal loop (geothermal heat exchanger) to heat as an alternate heat source and sink is well known to provide many benifits. The use of thermal energy storage (TES) reduces the heat pump capacity and peak cooling load needed in large building by as much as 40 to $60\%$ with less mechanical equipment and less space for mechanical room. Additionally TES can reduce the size and cost of the geothermal loop by 1/3 to 1/4 compared to ground coupled heat pump system that is designed to meet the peak heating and cooling load and also can eliminate difficuties of geothermal loop installation such as space requirements and thermal conditions of soil and rock at the urban area.

Comparison of Heat Exchanging Performances Depending on Different Heat Exchanging Pipe Arrangement (열회수장치의 열교환 파이프형식별 열교환 성능 비교)

  • 서원명;윤용철;강종국;김정섭
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.04b
    • /
    • pp.100-102
    • /
    • 2001
  • 본 연구에서는 온실의 난방에 사용되는 열풍식 난방기 등의 배기 연통에 부착하여 배출되는 가스로부터 열을 회수할 수 있는 장치를 개발함에 있어서 연통과 열회수 장치간의 열 교환 성능을 3가지 상이하게 설계된 열 교환 장치(Fig. 1 참조)에 대하여 실험적으로 비교 분석하였다. Fig. 1-(a)는 열 교회수기 개발을 위해 기존에 사용한 장치로서 회수용 공기의 흐름방향이 배기 연통과 직각을 이룬 형식이며, Fig. 1-(b) 및 (c)는 열 회수 성능 개선을 위해 새로 설계된 형식으로서 각각 열 교환 파이프의 배치형식이 상이하나 회수용 공기의 흐름방향이 180도로 굴곡되는 U-자형 흐름이 이루어지도록 하였다. 실험에 사용된 공기 순환 펜의 용량은 AB-형의 경우에는 최대 25㎥/min이고, C-형 및 D-형의 경우는 공히 최대 42㎥/min으로서 송풍전압 조절장치를 이용하여 풍량을 연속적으로 조절할 수 있도록 하였다. U-자형 흐름형식인 C-형 및 D-형의 경우 흐름 방향의 굴곡으로 인한 마찰저항이 있을 것으로 예상은 했으나 당초 예상했던 것에 비해 마찰 저항이 지나치게 큰 것으로 밝혀졌다. 비록 설계된 열교환 튜브의 배열형식별 열 교환기의 외부 모양이 달라 회수기의 표면을 통한 대류 열 교환이 다소 차이를 보일 것으로 예상되지만 본 연구에서는 열 회수장치에 내장된 열 교환 튜브부분만을 통한 열 회수율을 중심으로 형식간의 성능을 비교하였다. 실험을 통하여 측정된 자료중 대표적인 예는 Fig-2와 같으며, 측정자료를 기준으로 분석된 열회수 성능에 대한 설계형식별 비교 결과는 Table-1과 같으며, 분석된 결과를 요약하면 다음과 같다: 1. AB-형 열회수시스템의 경우, 초기 투자비용과 현재의 농용 전력요금 하에서 에너지 절감규모를 비교하면, 대체로 1년을 전후하여 투자에 대한 보상이 충분히 가능할 것으로 판단된다. 2. C-형 및 D-형 열회수시스템의 경우, 열 회수용 공기의 흐름방향이 동일 공간내에서 180도 굴절됨으로서 저항이 크게 발생되어 송풍 펜의 전압 증가에 따른 유속증가가 미미하였으며, 굴절형의 열교환장치는 비록 열교환면적은 직선형과 유사하더라도 송풍 펜의 공기저항이 커져서 결국 열 회수성능이 기대했던 것만큼 크게 개선되지는 못했다. 3. 송풍펜의 용량은 AB-형에 사용된 용량인 25㎥/min 전후가 적절할 것으로 판단되며, 적정 송풍 펜용량 하에서 열 회수성능은 굴절형이 직선형보다 효과적인 것으로 나타났다. 다만, 곡선형은 물론 직선형에서도 열교환 튜브의 배치밀도, 튜브 길이 및 두께 등의 변화에 따른 최적화 연구가 수반되어야 할 것으로 판단된다.

  • PDF

Optimal Capacity Determination of Hydrogen Fuel Cell Technology Based Trigeneration System And Prediction of Semi-closed Greenhouse Dynamic Energy Loads Using Building Energy Simulation (건물 에너지 시뮬레이션을 이용한 반밀폐형 온실의 동적 에너지 부하 예측 및 수소연료전지 3중 열병합 시스템 적정 용량 산정)

  • Seung-Hun Lee;Rack-Woo Kim;Chan-Min Kim;Hee-Woong Seok;Sungwook Yoon
    • Journal of Bio-Environment Control
    • /
    • v.32 no.3
    • /
    • pp.181-189
    • /
    • 2023
  • Hydrogen has gained attention as an environmentally friendly energy source among various renewable options, however, its application in agriculture remains limited. This study aims to apply the hydrogen fuel cell triple heat-combining system, originally not designed for greenhouses, to greenhouses in order to save energy and reduce greenhouse gas emissions. This system can produce heating, cooling, and electricity from hydrogen while recovering waste heat. To implement a hydrogen fuel cell triple heat-combining system in a greenhouse, it is crucial to evaluate the greenhouse's heating and cooling load. Accurate analysis of these loads requires considering factors such as greenhouse configuration, existing heating and cooling systems, and specific crop types being cultivated. Consequently, this study aimed to estimate the cooling and heating load using building energy simulation (BES). This study collected and analyzed meteorological data from 2012 to 2021 for semi-enclosed greenhouses cultivating tomatoes in Jeonju City. The covering material and framework were modeled based on the greenhouse design, and crop energy and soil energy were taken into account. To verify the effectiveness of the building energy simulation, we conducted analyses with and without crops, as well as static and dynamic energy analyses. Furthermore, we calculated the average maximum heating capacity of 449,578 kJ·h-1 and the average cooling capacity of 431,187 kJ·h-1 from the monthly maximum cooling and heating load analyses.