• Title/Summary/Keyword: 난방등

Search Result 403, Processing Time 0.028 seconds

찬바람이 불면 열효율에 올인하라

  • 최희철
    • Feed Journal
    • /
    • v.3 no.10 s.26
    • /
    • pp.122-127
    • /
    • 2005
  • "2003년 중반부터 국제유가는 등락을 거듭하며 상승추세를 지속해오며 사상 최고의 가격을 연일 경신하고 있다. 배럴달 25달러 선에 머물던 국제유가는 현재 70달러선을 오르내리고 있고 카트리나 등 대형태풍과 겨울철 성수기를 앞두고 난방유 부족에 대한 우려 및 원유재고 감소 등으로 인하여 고유가 기조는 계속될 전망이다. 향후에도 중국, 인도 등 아시아 국가들의 빠른 산업화로 석유수요는 증가세를 지속하고 산유국의 증산여력도 미미한 실정이며 산"

  • PDF

The Optimization of Cylindrical Perforated Burner for Condensing Gas Boiler (콘덴싱 가스보일러용 원통형 다공버너의 최적화 연구)

  • 이창언;장기현;이강주;정영식
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.10-17
    • /
    • 2002
  • The objective of performing this study is to develop low emission condensing gas boiler. To reduce NOx and CO, three reasonable distances between burner and heat exchanger were decided through the experiments of model plane burner. Three burners with different diameter were made and then emission characteristics were examined. The optimum burner geometry was determined from flame stability, pollutant emission characteristics and applicability to the practical boiler system. In the domain of equivalence ratio 0.68~0.85, turn-down ratio of the burner designed by this research was extended to a wider range of 5 : 1. Thermal efficiency of the boiler developed by this study reached to 97% (LHV basis) of heating water efficiency at heating load of 20,000 kcal/hr when fueled by both of LNG or LPG. Emission ($O_2$=0%, wet basis) of NOx and CO concentration was 26 ppm and 85 ppm when fueled by LNG, 41 ppm and 113 ppm when fueled by LPG respectively.

Optimum Wattage and Installation Height of Nano-Carbon Fiber Infrared Heating Lamp for Heating Energy Saving in Plug Seedling Production Greenhouse in Winter Season (동절기 공정육묘장의 난방 에너지 절감을 위한 나노탄소섬유적외선 난방등의 적정 전력과 설치 높이)

  • Kim, Hye Min;Kim, Young Jin;Hwang, Seung Jae
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.302-307
    • /
    • 2016
  • The aim of this study was to examine the optimum wattage and installation height using nano-carbon fiber infrared heating lamp (NCFIHL) for heating energy saving and plug seedling production in plug seedling production greenhouse in winter season. NCFIHL of 700 and 900 W was installed over the bed ($1.2{\times}2.4m$) as 0.7, 1.0, and 1.3 m height, respectively, for the production of grafted watermelon seedling in venlo-type glasshouse. Watermelon (Citrullus lanatus (Thunb.) Manst.) 'Jijonggul' and gourd (Lagenaria leucantha Rusby.) 'Sunbongjang' were used as scions and rootstocks, respectively. The scions and rootstocks were grafted by single cotyledon ordinary splice grafting. Light intensity of NCFIHL was below the $1{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ in all treatment. Spectral distributions of NCFIHL presented mostly infrared area. When outside air temperature was below $10^{\circ}C$, 700 and 900 W NCFIHL installed with 0.7 m height treatment and 900 W NCFIHL installed with 1.0 m height treatment maintained the setting air temperature ($20^{\circ}C$) at night. In the result of taking thermal imaging, the grafted watermelons were getting warm fast in 900 W NCFIHL installed with 0.7 m height treatment at night. Compactness of the grafted watermelons was the greatest in 700 W NCFIHL installed with 1.3 m height treatment. The results indicate that NCFIHL installed above 1.0 m height using 700 W was suitable for production of plug seedling.

Survey and model development of the mechanization for swine farming (양돈농가의 기계화 실태분석 및 모델개발)

  • 이성현;박원규;강창호;오권영
    • Journal of Bio-Environment Control
    • /
    • v.7 no.2
    • /
    • pp.91-108
    • /
    • 1998
  • This study was carried out to survey basic information of swine farms on the machine holdings. facility type. management of manure by farm scale and operation, and then to develop the mechanization model. Manual feeding was common for sows and nursing sows. but automation feeding was normally furnished for weaners. growing pigs and castrated male pigs. Water supplies was completely automated for all of the surveyed swine farms. Fully mechanized and automated system would not be feasible and affordable for the small scale farms breeding less than 500 heads. Because the environmental control for the nursing sows and weaner was important, some swine houses were constructed with the windowless type. However, the furnished rates ranged from 22.2% to 44.4% of the surveyed nursing sow and weaner houses at the farm scales. In the future, a computerized ventilation system would be commended for the efficient use of heat energy and to maintain the desirable temperature of swine buildings. Over-investment for large scale farm and over-crowded pigpen of small farm would cause wasting construction expenses and spreading epidermic diseases Hence, the size of swine building should follow the recommended scale. The fermentation drier was recommended for the manure management. Urine could be recycled or discharged after treating by the activated sludge process.

  • PDF

Analysis of Heating and Cooling Energy Consumption in Rental and Sales Apartments in Busan (부산시 임대아파트 및 분양아파트의 냉난방에너지 소비량 분석)

  • Lee, Kyung-Hee;Lee, Jun-Gi
    • Land and Housing Review
    • /
    • v.12 no.3
    • /
    • pp.79-85
    • /
    • 2021
  • This study analyzed the energy consumption differences between rental and owner owned (purchased) apartments in Busan, South Korea during the cooling and heating seasons. Analysis revealed that the average electricity consumed for cooling was 2.5 kWh/m2·yr for rental apartments and 2.3 kWh/m2·yr for purchased apartments, a difference of 0.2 kWh/m2·yr. The average electrical heating energy consumption was 3.3 kWh/m2·yr for rental apartments and 2.2 kWh/m2·yr for purchased apartments, a difference of 1.1 kWh/m2·yr. It was estimated that the use of electric blankets and heaters was higher in rental apartments than purchased apartments resulting in higher electrical heating energy consumption. The average gas heating energy consumption was 7.0 kWh/m2·month for rental apartments and 6.8 kWh/m2·month for purchased apartments. When electricity and gas usage was combined for heating, the average total heating energy consumption was 10.3 kWh/m2·month for rental apartments and 9.0 kWh/m2·month for purchased apartments. This indicates that rental apartments consume 1.3 kWh/m2·month more energy than purchased apartments during heating season. Overall, rental apartments consume more energy than purchased apartments during both the cooling and heating seasons.

Forecasting of Heat Demand in Winter Using Linear Regresson Models for Korea District Heating Corporation (한국지역난방공사의 겨울철 열수요 예측을 위한 선형회귀모형 개발)

  • Baek, Jong-Kwan;Han, Jung-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.3
    • /
    • pp.1488-1494
    • /
    • 2011
  • In this paper, we propose an algorithm using linear regression model that forecasts the demand of heated water in winter. To supply heated water to apartments, stores and office buildings, Korea District Heating Corp.(KDHC) operates boilers including electric power generators. In order to operate facilities generating heated water economically, it is essential to forecast daily demand of heated water with accuracy. Analysis of history data of Kangnam Branch of KDHC in 2006 and 2007 reveals that heated water supply on previous day as well as temperature are the most important factors to forecast the daily demand of heated water. When calculated by the proposed regression model, mean absolute percentage error for the demand of heated water in winter of the year 2006 through 2009 does not exceed 3.87%.

Automatic Control System of Vertical Agitation Heater for Controlling Temperature of Greenhouse (시설하우스 온도 조절을 위한 수직형 교반 히터 자동제어 시스템)

  • Kwak, Yun-Ah;Park, Kyoung-Wook;Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.5
    • /
    • pp.623-628
    • /
    • 2015
  • As the current heating control of the greenhouse is located in specifically designed place, there is an inevitable difference in degrees depending on the latitude in it. Even though it is necessary to maintain the proper temperature in the greenhouse producing vegetables and fruit plants, the difference between ups and downs in the facilities results in the increasing energy consumption to both warm and cool down the facilities. The newest heating method, automatic control system of vertical agitation heater, which manipulates the inner air circulation efficiently, is suggested in this paper. The proposed system utilizes both the upper temperature and the lower temperature, and controls the air circulation fan and heating independently, so that maximizes the efficiency of heating with the minimum energy and implements predictable planning of farm products.

Performance Improvement Technology on a Continuous Heating Heat Pump at Frost Condition (착상조건에서 연속난방이 가능한 히트펌프 성능 향상 기술)

  • Jeon, Chang-Duk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.573-577
    • /
    • 2013
  • Heat pumps come into wide use because high energy efficiency can be obtained and diverse heat sources like geothermal heat, waste heat and air are available. It is necessary for an air source heat pump to defrost in order to remove frost on the surfaces of an outdoor heat exchanger. It is impossible for continuous heating if reverse cycle operation is used as defrosting method, furthermore it causes the degradation of COP. In this study an fin-tube heat exchanger with three rows was used as an outdoor coil. One row among three rows of the heat exchanger was used like a condenser in order to remove frost on it, the others were used as evaporator to accomplish continuous heating. Each row was switched in order from a condenser to an evaporator in specified time interval. Tests were carried out during minimum 180 minutes at the defrost-heating test condition(dry bulb temperature $2^{\circ}C$, wet bulb temperature $1^{\circ}C$) described in KS C 9306. Time-averaged COP was about 20% higher than that of conventional defrosting method.

Aplication of the Thermodynamic Measurement Method for On-site Performance Evaluation of Hot Water Pumps Used in District Heating (지역난방 중온수 펌프의 현장 성능평가를 위한 열역학적 측정법 적용)

  • Park, Cheol Gyu;Yoo, Hoseon
    • Plant Journal
    • /
    • v.17 no.1
    • /
    • pp.50-57
    • /
    • 2021
  • It is very difficult to accurately calculate efficiency of each accessory device constituting the pump system and pump efficiency by the Conventional efficiency measurement method only. Therefore, this study introduced the lastest Thermodynamic pump efficiency measurement method in the district heating pump system for the first time in Korea. As a result, data uncertainty was high by the Conventional method, but the pump and Hydraulic Coupling efficiency values applied the Thermodynamic and Conventional method parallel measurement data were able to derive meaningful results that verified the reliability and adequancy of the pump performance measurement method by performing complementary roles. In additon, as a result of applying the Thermodynamic method to the distirct heating pump system, despite the high temperature environment of up to 120 ℃, it was possible to verify the reliability of the Thermodynamic method, such as high stable data mesurement, and durability of the measurement equipment.

자동차 배기가스와 대기오염

  • Lee, Yeong-Ju
    • Defense and Technology
    • /
    • no.7 s.281
    • /
    • pp.66-75
    • /
    • 2002
  • 과거 10년전만해도 산업, 난방, 발전 등이 대기오염의 주된 원인이었으나 자동차의 증가로 말미암아 최근에는 자동차의 배기가스 즉 질산화물질(NOx), 일산화탄소(CO), 탄화수소(HC), 총먼지(TSP : Total Solid Particlate), 아황산가스(SO2) 등이 대기를 오염시키는 주요 물질이 되었다. 인구의 증가, 산업의 발달, 경제수준의 향상은 자동차 증가를 촉진시키는데 촉매제 역할을 해왔으며 대도시에서의 자동차에 의한 오염물질 배출량은 앞으로도 차량의 증가와 더불어 가속화할 전망이다.

  • PDF