• 제목/요약/키워드: 난방공조

검색결과 51건 처리시간 0.034초

외기 전용 공조기의 동특성 시뮬레이션 (Dynamic Simulation of a Dedicated Outdoor Air-conditioning System)

  • 김정민;김영일;정광섭;박승태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.322-327
    • /
    • 2007
  • Dedicated outdoor air-conditioning(DOA) system that utilizes pre-cooling and desiccant dehumidification can be superior to conventional cooling and reheating system with respect to energy consumption and indoor thermal comfort. In this work, simulation has been conducted to study various factors that affect the performance of DOA. Dynamic simulation shows the transient variation of temperature and humidity as the on/off control logic is imposed. Exit humidity of process air and flow rate are varied to study the effect on exit temperature of process air, dehumidification quantity, required regeneration temperature and exit humidity of regeneration air. For an outdoor air condition of $28.5^{\circ}C$ temperature, 16 g/kg humidity ratio and 2000 cmh flow rate, the dehumidification efficiency is increased by 4.6% as the flow rate is doubled.

  • PDF

접목묘 활착 과정의 소비전력 및 전력요금 분석 (Analysis of Electric Energy Consumption and Its Cost in Graft-taking of Grafted Seedlings)

  • 김용현;김진국;이상헌
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2002년도 동계 학술대회 논문집
    • /
    • pp.204-209
    • /
    • 2002
  • 본 실험은 주택용, 일반용, 교육용, 산업용, 농사용, 심야전력 등 국내의 종별요금체계에 따라 인공광을 이용한 접목묘 활착촉진장치에서 소비된 전기에너지와 전력요금을 비교하고자 수행되었다. 그 결과 전력요금은 일반용>교육용>산업용>심야전력>농사용의 순서로 나타났으며 접목묘 1주를 활착시키는 데 필요한 전기요금은 농사용의 경우 9.24원이었으며, 일반용 전력요금과 비교할 때 봄과 가을, 겨울, 여름철의 1주당 생산단가는 각각 2.3배, 2.4배, 3.4배로 나타났다. 또한 본 실험에서 소비된 전력은 컴프레서, 가열기, 조명, 가습기, 송풍기의 순서로 각각 28%, 57%, 11%, 3%, 1%로 나타났다. 활착촉진장치에서 소비된 전력 가운데 공조 시스템, 즉 냉·난방이 차지하는 비중이 전체의 85%로서 매우 높게 나타난 바, 공조 시스템에 대한 전력소모량의 절감 방안이 우선적으로 강구되어야 할 것으로 판단된다.

  • PDF

전기차 기반의 1톤급 상용차용 통합공조 시스템에 관한 연구 (A Study on Integrated Air-conditioning System for Electric Vehicle Based 1-ton Class Commercial Vehicle)

  • 백수황;김철수
    • 한국전자통신학회논문지
    • /
    • 제14권2호
    • /
    • pp.361-368
    • /
    • 2019
  • 본 논문은 전기차 기반의 1톤급 상용차용 통합공조 시스템에 관한 연구이다. 전기 상용차의 경우 화물의 승하차를 위해 문의 개폐가 빈번하게 이루어지기 때문에 열손실이 크게 발생한다. 따라서 냉난방 부하가 승용 전기차에 비해 더 크게 요구된다. 결과적으로 승객이 요구하는 열 쾌적성을 만족하기 위해서 냉난방 시스템이 소비하는 에너지가 승용 전기차 보다 크다. 이러한 단점을 극복하기 위해 효율적인 통합공조 시스템을 적용한 연구를 수행했다. 최종적으로 1톤급의 경상용 전기트럭의 상품성 개선과 전기트럭 분야의 산업 생태계 기반 확충을 위한 고효율 공조 시스템 개발을 위해 냉방을 위한 전동식 압축기와 난방을 위한 히트펌프 시스템의 구상 설계와 해석적 검증을 수행한다.

중앙난방시스템의 유량제어방식에 따른 제어특성 연구 (Control Characteristics with Flow Rate Control Methods in Central Heating System)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권1호
    • /
    • pp.32-37
    • /
    • 2011
  • In this study, control characteristics and energy performance with flow rate control methods were reviewed with the simulation. The heating system is classified such as fan coil unit and HVAC system currently used in buildings with valve control and pump inverter control. The simulation analysis program is made by TRNSYS ver. 15 with the actual data. As a result of this study, the central heating system with pump inverter control decreases electricity energy and reduces gas consumption. Inverter control method shows better performance in comparison with valve control one for energy saving.

기획-보일러사들의 냉방사업 진출기

  • 전국보일러설비협회
    • 보일러설비
    • /
    • 8호통권151호
    • /
    • pp.104-109
    • /
    • 2006
  • 보일러회사들의 사업다각화 기세가 놀라울 정도다. 특히 난방사업과 냉방사업을 아우르는 다각화는 유난히 계절을 타는 보일러 회사들에게는 최적의 조합으로 꼽히고 있다. 귀뚜라미보일러와 경동보일러가 그렇다. 이들 회사들은 동절기를 겨냥한 난방 시즌이 끝나도 하절기를 겨냥한 냉방 시즌이 기다리고 있으니 일년 365일을 항상 같은 템포로 유지할 수 있다. 가을철 추수가 끝나면 기나 긴 농한기에 접어 드는 농촌처럼 한 구석이 허전했던 보일러 회사의 대리점들도 이제는 손발에 땀이 나게 뛰기만 하면 된다. 하지만 귀뚜라미와 경동의 사업 내용은 전혀 다르다. 귀뚜라미는 에어컨의 제조원이고 경동은 판매원이다. 귀뚜라미가 센추리 아산공장을 인수하고 지난달에는 범양공조까지 흡수하면서 에어컨 메이커의 메이저를 꿈꾸고 있는 반면 경동은 세계 최대 에어컨 회사인 캐리어와 손잡고 마케팅 컴퍼니의 메이저 자리를 노리고 있다. 진입방식은 다르지만 냉난방 전문 기업으로 변신을 꾀하고 있는 귀뚜라미와 경동보일러의 에어컨 사업을 들여다 본다.

  • PDF

A Frost-less Heat Pump

  • 황윤제;이원희
    • 대한설비공학회지:설비저널
    • /
    • 제31권3호
    • /
    • pp.53-58
    • /
    • 2002
  • 대부분의 가정용 냉난방겸용 공기조화기(히트펌프)는 실외온도가 $5^{\circ}C$ 이하이고, 습도가 높은 저온고습조건에서 난방운전을 하면 열교환기 표변에 서리가 발생하고, 이로 인해 시스템의 성능이 떨어지게 된다. 이를 방지하기 위하여 어느 일정 조건이나 시간이 되면 히트펌프는 제상운전을 하게 되는데, 보통의 가정용 히트펌프의 경우 난방운전도중에 사이클을 냉방운전으로 전환하여 실외 열교환기의 온도를 높여 줌으로써 제상을 하는 방식 (Cycle reversing method)을 사용하고 있다. 이 방식은 부가적인 제상회로플 구성하 거나 히터를 첨가하는 등의 재료비 증가 없이 제상을 수행한다는 장점이 있으나, 시스템의 에너지 효율 측면에서 불리할 뿐만 아니라, 소비자의 입장에서 보면 제상운전이 진행되는동안에 따뜻한 바람이 공급되지 않아 쾌적한 공조를 제공받지 못한다는 단점이 있다. 본 자료에서는 먼저 제상방석에 관하여 그 종류와 특정을 알아보고, 최근에 진행되고 있는 착상 지연기술 중 어큐물레이터 내에 히터를 설치하는 방식(Viung C. Mei, et al., 2002, ASHRAE TRANSSACTIONS, V 108, Pt. 1)에 대하여 소개하고자 한다.

  • PDF

빌딩 설비의 실무 포인트(3) - 보일러 편(1)

  • 대한전기협회
    • 전기저널
    • /
    • 3호통권51호
    • /
    • pp.79-81
    • /
    • 1981
  • 빌딩의 난방이나 공조에서 보일러는 필요부가결한 설비다. 보일러라 하면 옛날에는 $\ulcorner$그것은 기계분야$\lrcorner$라고 말하고 있었기에 보일러가 고장이 나도 모른척 해도 좋았으나 지금은 자동제어의 보에 의해 전기기술자가 동원될 때가 많게 되었다. 이것은 이후에 소개될 냉동기에 관해서도 같다고 할 수 있다. 기계설비는 전기와 분리해서 생각할 수 없다는 것이다. 바꾸어 말하면 전기기술자라 할지라도 어느 정도 기계에 대한 화식없이는 완전한 보수를 할 수 없다는 것이 된다. 그래서 전기기술자로서 꼭 알아야 할 보일러의 기초화식과 실무화식을 소개한다.

  • PDF