• Title/Summary/Keyword: 나사이음

Search Result 832, Processing Time 0.03 seconds

Analysis of implant strain value exerted using different screw tightening protocols in screw-retained 3-unit prostheses (3본 나사 유지형 임플란트 보철물의 고정 방식에 따른 임플란트 고정체 치경부에 발생하는 변형율 비교분석)

  • Kim, Sang-Beom;Lee, Du-Hyeong;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.321-327
    • /
    • 2020
  • Purpose: The purpose of this study was to measure and compare the strain value exerted on the cervical area using different screw tightening protocols in implant-supported, screw-retained 3-unit prostheses. Materials and methods: Strain gauges were attached to four implants: two external and two internal. Thereafter, two study model were designed each type using acrylic resin. CAD-CAM was used to design hex and nonhex abutments for each group (EH, ENH, IH, and INH group) and Screw-cement-retained prostheses were also designed using a nonprecious base metal. Abutment was fixed with 10 Ncm torque, and the prosthesis was cemented. Screws were fixed with 30 Ncm torque using different three protocols. After 5 min, the strain gauge level was measured, and group analysis was performed (α=.05). Results: External group showed significantly lower strain values than internal group and the EH group showed significantly lower strain values than the ENH group (P<.05). There was no difference in strain value based on the types of screw tightening protocols in same group (P>.05). The IH group exhibited significantly higher strain values than the INH group and the IH group showed a significant difference in strain values based on the types of screw tightening protocols used (P<.05). Conclusion: There was no significant effect on the external type in the implant-supported, screw-retained prostheses. However, strain values were high in the internal type, and the types of screw tightening protocol significantly affected these implants.

Removal of fractured implant screws: case report (파절된 임플란트 나사의 제거: 증례보고)

  • Kim, Tae-Su;Lee, Jae-Hyun;Lee, Won-Sup;Lee, Su-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.1
    • /
    • pp.60-66
    • /
    • 2015
  • Screw loosening and screw fracture of abutment is one of most frequent mechanical complications in implant restoration. Fractured fragments in implant restoration like abutment and screw should be completely removed and the procedure needs minimal damage to the fixture of implant. In some cases, it could fail to remove fractured fragments and cause a lot of damage to the fixture of implant. These situations could render implant unusable at the worst. This article describes three different situations and simple techniques for successful removal of fractured fragments without damage of implants. The procedures used are described in this clinical report.

Study on Improvement of Dimensional Accuracy of a Precision Plastic Screw Under Various Injection-Molding Conditions (사출성형 조건에 따른 정밀 플라스틱 나사의 형상정밀도 향상에 관한 연구)

  • Baek, Soon-Bo;Park, Keun;Youm, Chung-Ho;Ra, Seung-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1549-1554
    • /
    • 2010
  • Recently, plastic screws have replaced metal screws because of the former's light weight, thermal and electrical insulating properties, and anticorrosion characteristics. Plastic screws are usually produced by injection molding, which involves material shrinkage during the solidification of the polymer. This shrinkage results in the degeneration of the dimensional accuracy. In the present study, the effect of injection-molding conditions on the dimensional accuracy of plastic screws was investigated through a numerical simulation of injection molding; on the basis of this simulation, we could determine the mold-design parameters. The design of experiment was applied in accordance with the numerical analysis in order to optimize the injection-molding conditions with a view to improving the dimensional accuracy of the precision plastic screw.

Removal of a Femoral Interference Screw that Migrated Posteriorly after ACL Reconstruction, Using Posterior Trans-septal Portal - A Case Report - (전방 십자 인대 재건술 후 후방으로 전위된 대퇴 간섭 나사의 후방 경격막 도달법을 이용한 제거 - 증례 보고 -)

  • Ahn, Jin-Hwan;Lee, Sang-Hak;Ha, Hae-Chan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.187-191
    • /
    • 2006
  • Few cases have been reported in which the femoral interference screw has migrated into the posterior compartment after an ACL reconstruction. It usually requires removal, because it leads usually to mechanical symptom. However, the arthroscopic removal of a screw is a technically demanding procedure, especially in the case of an intact integrated ACL graft or one that is encapsulated around the screw. We present a case in which a displaced femoral interference screw migrated within the posterior compartment 11 years postoperatively, after the graft had been successfully incorporated at the femoral site and showed good continuity on MRI and arthroscopic examination. Although it is often technically challenging, through the use of a posterior trans-septal portal, we can successfully remove a displaced femoral interference screw even in the most difficult locations in the posterior compartment without damage to ACL graft.

  • PDF

Three-dimensional finite element analysis of stress distribution for different implant thread slope and implant angulation (임플란트 나사선 경사각과 식립 각도에 따른 3차원 유한요소 응력분석)

  • Seo, Young-Hun;Lim, Hyun-Pil;Yun, Kwi-Dug;Yoon, Suk-Ja;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • Purpose: The purpose of this study was to find an inclination slope of the screw thread that is favorable in distributing the stresses to alveolar bone by using three dimensional finite element analysis. Materials and methods: Three types modelling changed implant thread with fixed pitch of 0.8 mm is the single thread implant with $3.8^{\circ}$ inclination, double thread implant with $7.7^{\circ}$ inclination and the triple thread implant with $11.5^{\circ}$ inclination. And three types implant angulation is the $0^{\circ}$, $10^{\circ}$ and $15^{\circ}$ on alveolar bone. The 9 modelling fabricated for three dimensional finite element analysis that restored prosthesis crown. The crown center applied on 200 N vertical load and $15^{\circ}$ tilting load. Results: 1. The more tilting of implant angulation, the more Von-Mises stress and Max principal stress is increasing. 2. Von-Mises stress and Max principal stress is increasing when applied $15^{\circ}$ tilting load than vertical load on the bone. 3. When the number of thread increased, the amount of Von-Mises stress, Max principal stress was reduced since the generated stress was effectively distributed. 4. Since the maximum principal stress affects on the alveolar bone can influence deeply on the longevity of the implants. When comparing the magnitude of the maximum principal stress, the triple thread implant had a least amount of stress. This shows that the triple thread implant gave a best result. Conclusion: A triple thread implant to increase in the thread slope inclination and number of thread is more effective on the distribution of stress than the single and double thread implants especially, implant angulation is more tilting than $10^{\circ}$ on alveolar bone. Thus, effective combination of thread number and thread slope inclination can help prolonging the longevity of implant.

Detorque force and surface change of coated abutment screw after repeated closing and opening (코팅된 지대주 나사의 반복 착탈 후 풀림력과 표면변화에 대한 연구)

  • Jang, Jong-Suk;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.500-510
    • /
    • 2008
  • Statement of problem: Recently researches about WC/C (Tungsten Carbide/Carbon) or TiN (Titanium Nitride) coating on abutment screws are going on. It decreases friction coefficient, resistance against corrosion and withdrawal of physical fragility when the coating is applied to the metal surfaces. It is reported that coated abutment screws improved abrasion, adaptability and detorque force. Purpose: This study is about the effects of coated abutment screws on loosening of screw and for the purpose of solving the loosening phenomenon of abutment screws which is clinical problem. Material and methods: Detorque force and surface changes are compared when 10 times of repeated closing and opening are applied to both uncoated titanium abutment screws (Group A) and coated abutment screws with WC/C (Group B) and TiN (Group C). Each group was made up of 10 abutment screws. Results: 1. Before repeated closing and opening, Somewhat rough surface with regular direction was observed in Group A. Coated granules were observed in group B and group C and overall coated layer appeared in regular and smooth form. 2. Before repeated closing and opening, The coated surface showed bigger and thicker size of coated granules in Group C than Group B. 3. After repeated closing and opening, abrasion and deformation of abutment screw surface was observed in Group A and Group B. Exfoliation phenomenon was observed in Group B. 4. Group A showed biggest range of decrease when the weight changes of abutment screws were measured before and after repeated closing and opening. Group C showed less weight changes than Group B but there was no statistical difference between two groups. 5. Group B and Group C showed higher average detorque force than Group A and there was statistical difference. 6. Group A showed more prominent decrease tendency of average detorque force than Group B and Group C. Conclusion: Coated abutment screws with WC/C or TiN did not show prominent surface changes than uncoated titanium abutment screws even though they were repeatedly used. And they showed excellent resistance against friction and high detorque force. Thus it is considered that adaptation of WC/C or TiN coating on abutment screws will improve the screw loosening problem.

The effect of a titanium socket with a zirconia abutment on screw loosening after thermocycling in an internally connected implant: a preliminary study (내부연결 임플란트용 타이타늄 소켓을 이용한 지르코니아 지대주에서 열순환이 나사풀림에 미치는 영향: 예비연구)

  • Kyung, Kyu-Young;Cha, Hyun-Suk;Lee, Joo-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.114-118
    • /
    • 2017
  • Purpose: The aim of this study was to investigate the effects of a titanium component for the zirconia abutment in the internal connection implant system on screw loosening under thermocycling conditions. Materials and Methods: Internal connection titanium abutments and external connection zirconia abutments with titanium sockets were connected respectively to screw-shaped internal connection type titanium implants with 30 Ncm tightening. These implant-screw-abutment assemblies were divided into two groups of five specimens each; titanium abutments as control and zirconia abutments with titanium sockets as experimental group. The specimens were subjected to 2,000 thermocycles in water baths at $5^{\circ}C$ and $55^{\circ}C$, with 60 seconds of immersion at each temperature. The removal torque values (RTVs) of the abutment screws of the specimen were measured before and after thermocycling. RTVs pre- and post-thermocycling were investigated in statistics. Results: There was not screw loosening identified by tactile and visual inspection in any of the specimens during or after thermocycling. The mean RTV difference for the control group and the experimental group were $-1.34{\pm}2.53Ncm$ and $-1.26{\pm}2.06Ncm$, respectively. Statistical analysis using an independent t-test revealed that no significant differences were found in the mean RTV difference of the groups (P > 0.05). Conclusion: Within the limitations of this in vitro study, the titanium socket for the zirconia abutment did not show a significant effect on screw loosening under thermal stress compared to the titanium abutment in the internal connection implant.

Optimization of orthodontic microimplant thread design (교정용 마이크로 임플란트의 나사산 디자인 최적화)

  • Kim, Kwang-Duk;Yu, Won-Jae;Park, Hyo-Sang;Kyung, Hee-Moon;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.41 no.1
    • /
    • pp.25-35
    • /
    • 2011
  • Objective: The purpose of this study was to optimize the thread pattern of orthodontic microimplants. Methods: In search of an optimal thread for orthodontic microimplants, an objective function stability quotient (SQ) was built and solved which will help increase the stability and torsional strength of microimplants while reducing the bone damage during insertion. Selecting the AbsoAnchor SH1312-7 microimplant (Dentos Inc., Daegu, Korea) as a control, and using the thread height (h) and pitch (p) as design parameters, new thread designs with optimal combination of hand p combination were developed. Design soundness of the new threads were examined through insertion strain analyses using 3D finite element simulation, torque test, and clinical test. Results: Solving the function SQ, four new models with optimized thread designs were developed (h200p6, h225p7, h250p8, and h275p8). Finite element analysis has shown that these new designs may cause less bone damage during insertion. The torsional strength of two models h200p6 and h225p7 were significantly higher than the control. On the other hand, clinical test of models h200p6 and h250p8 had similar success rates when compared to the control. Conclusion: Overall, the new thread designs exhibited better performance than the control which indicated that the optimization methodology may be a useful tool when designing orthodontic microimplant threads.

Influence of microthread design on marginal cortical bone strain developement: A finite element analysis (임플란트 경부 미세나사 디자인이 치밀골의 스트레인에 미치는 영향)

  • Chun, Seung-Geun;Cho, Jin-Hyun;Jo, Kwang-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.215-223
    • /
    • 2010
  • Purpose: The present study was aimed to evaluate the level of cortical bone strain during the placement of an implant. The primary concern was to investigate if the extent of overloading area near the marginal bone could be affected by microthread fabricated at the cervical 1/3 of an implant. Materials and methods: Three dimensional finite element analysis was used to simulate the insertion of 3 implants. Control model was $4.1{\times}10$ mm implant (Submerged model, Dentis Co,, Daegu, Korea) equipped with a main thread only. Type I was with main thread and microthread, and Type II had similar thread pattern but was of tapered body. A PC-based finite element software (DEFORM 3D ver 5, SFTC, Columbus, OH, USA) was used to calculate a total of 3,600 steps of analysis, which simulated the whole insertion. Results: Results showed that the strain field in the marginal bone within 1 mm of the implant wall was higher than 4,000 micro-strain in the control model. The size of bone overloading was 1-1.5 mm in Type I, and greater than 2 mm in Type II implants. Conclusion: These results indicate that the marginal bone may be at the risk of resorption on receiving the implant for all 3 implant models studied. Yet, the risk was greater for Type I and Type II implants, which had microthread at the cervical 1/3.

The incidence of the abutment screw loosening and its affecting factors in posterior implant restorations (구치부 임플란트 고정성 수복물에서의 지대주 나사 풀림 현상과 이에 영향을 미치는 요인)

  • Hong, Su-Jung;Bae, Jung-Yoon;Kim, Hyun-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.212-217
    • /
    • 2018
  • Purpose: This study was to assess clinically the incidence of abutment screw loosening of posterior implant-supported fixed prosthesis and its affecting factors. Materials and methods: 391 implant-supported crowns restored from January 2013 to January 2016 were included in this study. All restorations were fabricated with either a single crowns or a splinted crown, and cemented with temporary cement. The incidence of abutment screw loosening is investigated and gender, restoration position, opposing teeth, restoration type, abutment connection type were assessed as possible factors affecting abutment screw loosening. Results: During the observation period (2 - 5 years), abutment screw loosening was found in 29 restorations (7.4%). It took 3 to 48 months (means 19.5 months) to loose the screw, and three of these implants were fractured. Among the factors considered, there were statistically significant differences at abutment screw loosening rate between molar group (9.4%) and premolar group (2.6%) (P<.019). According to the type of opposing teeth, there were statistically significant differences between nature teeth (74.7%) and implant (25.0%), removable denture (3%) (P<.019). The other possible factors did not have a significant effect on loosening of the abutment. Conclusion: The incidence of abutment screw loosening in posterior restoration was 7.4%. Abutment screw loosening were more likely to occur in molars group than premolar group, and according to the opposing teeth, there were the greatest frequency in nature teeth than implant and removal denture. There was a statistically significant difference.