• Title/Summary/Keyword: 나노 채널 유동

Search Result 9, Processing Time 0.022 seconds

Numerical Study on Couette Flow in Nanostructured Channel using Molecular-continuum Hybrid Method (분자-연속체 하이브리드 기법을 이용한 구조물이 있는 나노 채널에서의 쿠에트 유동에 대한 수치적 연구)

  • Kim, Youngjin;Jeong, Myunggeun;Ha, Man Yeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.6
    • /
    • pp.429-434
    • /
    • 2017
  • A molecular-continuum hybrid method was developed to simulate microscale and nanoscale fluids where continuum fluidics cannot be used to predict Couette flow. Molecular dynamics simulation is used near the solid surface where the flow cannot be predicted by continuum fluidics, and Navier-Stokes equations are used in the other regions. Numerical simulation of Couette flow was performed using the hybrid method to investigate the effect of solid-liquid interaction and surface roughness in a nanochannel. It was found that the solid-liquid interaction and surface roughness influence the boundary condition. When the surface energy is low, slippage occurs near the solid surface, and the magnitude of slippage decreases with increase in surface energy. When the surface energy is high, a locking boundary condition is formed. The roughness disturbs slippage near the solid surface and promotes the locking boundary condition.

Simple Fabrication of Micromixer Based on Non-Equilibrium Electrokinetics in Micro/Nano Hybrid Fluidic System (단순공정으로 제작된 마이크로/나노 하이브리드 채널의 불균형 동전기성을 이용한 미세혼합기 연구)

  • Yu, Samuel;Kim, Sun-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.385-390
    • /
    • 2011
  • In this study, we developed a micromixer based on the non-equilibrium electrokinetics at the junction of a microchannel and nanochannel. Two fluid streams were mixed by an electro-osmotic flow and a vortex flow created as a result of the non-equilibrium electrokinetics at the junction of the microchannel and nanochannel. Initially, the microchannel was fabricated using Polydimethylsiloxane (PDMS) by the general soft lithography process and the nanochannel was created at a specific position on the microchannel by applying a high voltage. To evaluate the mixing performance of the micromixer, fluorescent distribution was analyzed by using the fluorescent dye, Rhodamine B. About 90% mixing was achieved with this novel micromixer, and this micromixer can be used in microsystems for biochemical sample analysis.

Study on Fluid Flow and Thermal Characteristics in a Nanoscale Channel Using MD Simulation (분자 동역학 시뮬레이션을 이용한 나노 스케일 채널 내에서의 유체 유동 및 열적 특성에 관한 연구)

  • Choi, Yong-Seok;Kim, Sung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1880-1884
    • /
    • 2004
  • To analyze the fluid flow and thermal characteristics in a nanoscale system, the planar Poiseuille flow of a Lennar-Jones liquid through parallel plates formed by fixed atoms is studied using nonequilibrium molecular dynamics simulations. The role of important simulation parameters such as the channel width, the magnitude of external field, the temperatures of the top and bottom plates, and the interaction potential parameter between fluid and wall atoms, which affect flow patterns and heat transfer rate inside the channel, are investigated. Under the various simulation conditions, interesting phenomena deviated from the continuum predictions have found.

  • PDF

Flow Characteristics Investigation of Gel Propellant with Al2O3 Nano Particles in a Curved Duct Channel (Al2O3 나노입자가 젤(Gel) 추진제의 곡관 유동특성에 미치는 연구)

  • Oh, Jeongsu;Moon, Heejang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.3
    • /
    • pp.47-55
    • /
    • 2013
  • Curved duct channel flow characteristics for non-Newtonian gel fluid is investigated. A simulant gel propellant mixed by Water, Carbopol 941 and NaOH solution has been chosen to analyze the gel propellant flow behavior. Rheological data have been measured prior to the flow analysis where water-gel propellant and water-gel propellant with $Al_2O_3$ nano particles are both used. The critical Dean number examined by the numerical simulation in the U-shape duct flow reveals that although water-gel-nano propellants have higher apparent viscosity, the critical Dean number do show no notable difference for both the two gel propellant. It is found that the power-law index may be a dominant parameter in determining the critical Dean number and that the gel with particles addition may be more vulnerable to Dean instability.

A Numerical Model for Non-Equilibrium Electroosmotic Flow in Micro- and Nanochannels (마이크로/나노 채널에서의 비평형 전기삼투 유동 모사를 위한 수치모델)

  • Kwak Ho Sang;Jr. Ernest. F. Hasselbrink,
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.161-164
    • /
    • 2004
  • A finite volume numerical model is developed for simulating non-equilibrium electroosmotic flow in micro- and nanochannels. The Guoy-Chapman model is adopted to compute the flow and electric potential. The Nernst-Planck equation is employed to trace unsteady transports of ionic species, i.e., time-dependent net charge density. A new set of boundary conditions based on surface charge density are designed rather than using the conventionally-employed zeta potential. A few issues for an efficient computation of electroosmotic flows are discussed. Representative computational examples are given to illustrate the robustness of the numerical model.

  • PDF

Fabrication of Microcapsules Encapsulating Fluorescent Nanoparticles and Visualization of Their Inclusion (형광 나노입자를 수용하는 마이크로캡슐의 제작 및 수용 가시화)

  • Kim, Eun-Young;Kim, Hyoung-Hoon;Go, Jeung-Sang
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.2
    • /
    • pp.16-20
    • /
    • 2011
  • This paper presents a fabrication method of microcapsules encapsulating fluorescent nanoparticles sensitive to an organic liquid, which is potentially applicable to the encapsulation of protein, cell and drug. It uses the supra-molecular self-assembly of a block copolymer at the interface of the stable and controllable droplets of water suspended with fluorescent nanoparticles and the polymer solved organic. The size and uniformity of the microcapsules were examined for the various polymer concentrations by using SEM image analysis. The maximum standard deviation of the produced microcapsules of less than 3.5% was obtained from the microcapsules produced from the same conditions. The inclusion of fluorescent nanoparticles was visualized in the fluorescence microscope and by using TEM image. It is shown that this fabrication method can provide the uniform size microcapsules with a higher inclusion.

Production of alginate hollow tube by diffusion of hydrogen ions at oil-prepolymer interface using a microfluidic chip (Oil-prepolymer 계면에서의 수소이온 확산을 통한 마이크로 플루이딕 칩 기반의 alginate hollow tube 제조)

  • Lee, Jae-Seon;Tran, Buu Minh;Nguyen, Phuoc Ouang Huy;Lee, Nae-Yun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.109-109
    • /
    • 2017
  • 알지네이트 하이드로 젤은 해조류에서 추출되는 천연 고분자인 알지네이트가 칼슘 또는 마그네슘 양이온과 이온가교(Ioninc cross linking)를 형성할 때 알지네이트의 고분자 구조가 칼슘, 마그네슘 양이온을 감싸면서 형성되는 고분자이다. 알지네이트 하이드로 젤은 높은 생체적합성(Biocompatibility)으로 인해 세포 재생을 위한 조직공학 및 재생의학, 약물전달 등의 제약 관련 분야에 광범위하게 적용될 수 있는 물질로 많은 연구가 이루어지고 있다. 본 연구에서는 마이크로 플루이딕 칩을 이용하여 알지네이트 튜브를 제조하였다. 먼저 유동 포커싱 방식(flow focussing)을 유도할 수 있는 PDMS(Polydimethylsiloxane) 마이크로 플루이딕 칩을 제조하였다. 마이크로 플루이딕 칩은 CNC(Computer Numeric Control) milling machine을 이용한 template를 만들고 NOA mold를 이용하여 최종 PDMS 칩을 제작하였다. 튜브를 만들기 위한 마이크로 채널은 내부 채널 ($200{\times}200um$), 중간 채널 ($200{\times}200um$) 및 외부 채널 ($200{\times}200um$)로 구성되며 내부, 중간, 외부의 유체가 합류하는 수집채널은 폭 500 um, 깊이 200 um로 구성되었다. 운반체로는 5%의 acetic acid를 함유한 mineral oil를 이용하였으며 내부의 core flow는 $H_2O$로 하였다. 중간 유체인 2% 알지네이트 프리폴리머는 칼슘 이온의 존재 하에서 젤화 과정이 매우 빠르기 때문에 마이크로 채널 내부에서의 반응을 제어하고 막힘을 방지하기 위해 수용성 복합 칼슘-에틸렌 디아민 테트라 아세트산 (EDTA)을 사용하였다. 본 마이크로 플루이딕 칩에 각각의 유체를 이동시켰을 때, 운반체인 oil phase의 수소이온은 중간 유체인 알지네이트 프리폴리머와의 계면을 통해 확산되어 Ca-EDTA 복합체로부터 칼슘 양이온의 방출을 유발하게 된다. 방출된 칼슘 양이온은 알지네이트 고분자와의 이온 가교를 통해 알지네이트 하이드로 젤을 형성하여, 각 유체의 flow에 따라 알지네이트 튜브를 쉽고 빠르게 제조 가능하였다. 본 연구에서 제조된 알지네이트 튜브는 인체 내 장기간 약물 전달을 위한 나노섬유로 활용하거나 인공혈관을 구성하는 extracellular matrix로 활용될 잠재력을 가지고 있어 추후 활발한 연구개발이 진행될 예정이다.

  • PDF

Pressure Drop and Catalytic Dehydrogenation of NaBH4 Solution Across Pin Fin Structures in a Microchannel Reactor (마이크로 Pin Fin 화학반응기에서 수소화붕소나트륨 수용액의 압력강하 및 탈수소 화학반응 연구)

  • Jung, Ki Moon;Choi, Seok Hyun;Lee, Hee Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.6
    • /
    • pp.381-387
    • /
    • 2017
  • Dehydrogenation from the hydrolysis of a sodium borohydride ($NaBH_4$) solution has been of interest owing to its high theoretical hydrogen storage capacity (10.8 wt.%) and potentially safe operation. An experimental study has been performed on the catalytic reaction rate and pressure drop of a $NaBH_4$ solution over both a single microchannel with a hydraulic diameter of $300{\mu}m$ and a staggered array of micro pin fins in the microchannel with hydraulic diameter of $50{\mu}m$. The catalytic reaction rates and pressure drops were obtained under Reynolds numbers from 1 to 60 and solution concentrations from 5 to 20 wt.%. Moreover, reacting flows were visualized using a high-speed camera with a macro zoom lens. As a result, both the amount of hydrogenation and pressure drop are 2.45 times and 1.5 times larger in a pin fin microchannel array than in a single microchannel, respectively.

Development of a general purpose molecular simulation system from microscopic to mesoscopic scales (미시영역에서 중간역역까지 적용 가능한 범용 분자 시뮬레이션 시스템의 개발)

  • Oh, Kwang-Jin
    • The KIPS Transactions:PartD
    • /
    • v.12D no.6 s.102
    • /
    • pp.921-930
    • /
    • 2005
  • In this paper, a general purpose molecular simulation system which has been developed by the author, are described. One of the most advantageous features is that the molecular simulation system can handle a coarse-grained model as well as an all-atom mode. Therefore, we can simulate mesoscopic phenomena as well as microscopic phenomena with the help of Langevin dynamics simulation and dissipative particle dynamics simulation techniques. Thus we could study anesthesia, protein folding, biopolymer flow in microchannel with single framework, which spans from microscopic to mesoscopic scales. We expect that we can also simulate many other bio/nano systems of technological importance which are not feasible by means of molecular dynamics simulation technique. Finally, performance data are shown and a bottleneck is identified for future optimization.