• Title/Summary/Keyword: 나노바이오

Search Result 445, Processing Time 0.025 seconds

Nanomagnetics-biomedical Convergence for Next Generation Biomedical Assays (나노자성-바이오.메디컬 컨버젼스 연구)

  • Kim, Cheol-Gi
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.4
    • /
    • pp.167-172
    • /
    • 2010
  • To meet on going challenges in nano-biomedical technology, the convergence of "spintronics", "biomedical" technology is a major break through in imaging, diagnosis and therapy, high-throughput genomic analysis. Especially magnetic bioassay is one of crucial devices for early diagnosis of specific analytes, point-of-care and U-health care application. In this paper, current status on high resolution magnetic sensors for bioassay and on-chip magnets for biomolecule transportation will be reviewed.

Nano Pillar의 두께에 따라 적용된 AlGaInP Vertical LED의 광추출효율 향상 연구

  • Ryu, Ho-Seong;Park, Min-Ju;Baek, Jong-Hyeop;O, Hwa-Seop;Gwak, Jun-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.593-593
    • /
    • 2013
  • 나노패턴 제작은 차세대 초고밀도 반도체 메모리기술과 바이오칩 등 나노기술의 핵심 분야로, 나노패턴 구조를 나노-바이오 전자소자 및 반도체 산업분야에 적용할 경우 시장 선점 및 막대한 부가가치 창출 등을 통해 국가경쟁력 강화에 크게 기여할 것으로 기대된다. 하지만 대면적 패턴형성이 어려워 뿐만 아니라 $300^{\circ}$ 이상의 열처리 과정에 의한 생산성이 떨어진다. 또한 나노구조가 잘 이루어진 차원, 표면상태, 결정성, 화학적 조성을 갖도록 하는 합성 및 제조상의 어려움 때문이다. 이에 반해 자기정렬 ITO Dot 형성은 상기 기술한 1차원 나노구조형성을 하는 것에 비하여, 나노구조를 제작하기 위하여 공정이 단순하며, 비용 및 생산성 측면에서 유리 할 것으로 생각된다. 이에 본 연구는 E-beam을 이용하여 형성된 ITO 박막에 HCl solution을 이용하여 자기정렬 ITO Dot 형성 후 n-AlGaInP Vertical LED[VLED] 표면에 nano pillar의 두께에 각기 다르게 형성하였으며, 최종적으로 제작된 VLED의 전기적, 광학적 특성을 조사하였다.

  • PDF

A Study on the Fluorescence Characteristics of Dye-doped Silica Nanoparticles for Integrated Bio Imaging (융합 바이오 이미징을 위한 염료 도핑 된 실리카 나노입자의 형광 특성에 관한 연구)

  • Kim, Ki-Chul
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.5
    • /
    • pp.45-50
    • /
    • 2018
  • The functional nanomaterials of fluorescent dye-doped silica nanoparticles(NPs) are applied to bio applications such as bio-labeling of DNA micro-array, and bio-imaging. Organic dye-doped fluorescent silica NPs exhibit excellent bio-compatibility, non-toxic, and highly hydrophilic properties. In this study, organic fluorescent dyes were dissolved in ethanol, and deionized(DI) water. Organic fluorescent dyes were physically adsorbed to silica NPs and chemically doped to silica NPs. The fluorescence characteristics(FLC) was investigated by UV lamp irradiation of 365 nm wavelength. As results, the FLC of dye-doped silica NPs exhibits better than dye-adsorbed silica NPs and the FLC was improved with the increase of concentration of doped-dyes. The fluorescent organic dyes were well dissolved in ethanol than DI water. The photostability of dye-doped silica NPs was superior than pure fluorescent organic dye. The FLC of optimized dye-doped silica NPs would be applied to agent of non-invasive fluorescence bio-imaging in live cell and in vivo.

Fabrication and Characterization of Triboelectric Nanogenerator based on Porous Animal-collagen (다공성 동물성-콜라겐을 이용한 마찰전기 나노발전기 제작 및 특성평가)

  • Shenawar Ali Khan;Sheik Abdur Rahman;Woo Young Kim
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.1
    • /
    • pp.179-187
    • /
    • 2023
  • Nanogenerators containing biomaterials are eco-friendly electronic devices in terms of being a non-polluting energy source and biodegradable electronic waste. In particular, the amount of waste will be also reduced if the biomaterial can be extracted from biowaste. In this study, a triboelectric nanogenerator was fabricated using animal collagen present in the skin of a mammal and its characteristion was proformed. The electro-anodic layer of the triboelectric nanogenerator was constructed by forming a collagen film using the spin coating method, and it was confirmed that the film was porous from scanning electron microscopy. The fabricated triboelectric nanogenerator exhibited an open-circuit voltage from 7 V at 3 Hz to 15 V at 5 Hz due to periodic mechanical movement, and a short-circuit current of 3.8 uA at 5 Hz. In conclusion, collagen-containing triboelectric nanogenerators can be power source for low-power operating devices such as sensors and are also expected to be useful for reducing electronic waste.

Fabrication of Nano-filter Device for High Efficient Separation and Concentration of Biomolecules (고효율 바이오물질 분리 및 농축을 위한 나노필터소자제작)

  • Huh, Yun Suk;Choi, Bong Gill;Hong, Won Hi
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.738-742
    • /
    • 2012
  • Here, we develop a new nanofilter device for the rapid and efficient separation of nanoparticles and biomolecules, exploiting the use of AAO mebrane with ordered nanopores in the range from 20 nm to 200 nm. Briefly, the chip comprises of a series of the upper and lower PDMS channels containing embedded inlet and outlet ports, and $50{\mu}m$ width microfluidic channel, and AAO membrane to be made the filtering zone. After assembling these components, the acrylate plastic plates were used to fix the device on the top and bottom side. When introducing the samples into the inlet ports of the upper PDMS channel, we were able to separate and concentrate the nanoparticles and target molecules at the filtering zone, and to elute the solutions containing the unwanted materials toward the lower PDMS channels normal to the direction of AAO membrane. To demonstrate the usefulness of the device we apply it to the SERS detection of nucleic acid sequences associated with Dengue virus serotype 2. We report a limit of detection for Dengue sequences of 300 nM and show excellent enhancement of Raman signals from the filter zone of the nanofilter device.