• Title/Summary/Keyword: 깊이진단

Search Result 256, Processing Time 0.026 seconds

A Study on the Integrity Assessment of Bare Concrete Bridge Deck based on the Attenuation of Radar Signals (레이더 신호의 감쇠특성을 고려한 일체식 콘크리트 교량 바닥판의 상태평가 방법 고찰)

  • Rhee, Ji-Young;Choi, Jae-Jin;Kim, Hong-Sam;Park, Ko-Eun;Choi, Myeong-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.84-93
    • /
    • 2016
  • The signal characteristic of radar wave on concrete decks is determined by the attenuation of the radar due to the conversion of EM(Electromagnetic) energy to thermal energy through electrical conduction, dielectric relaxation, scattering, and geometric spreading. In this study, it is found that the attenuation of radar signal received on top rebars in bare deck concrete with 2 way travel time shows a general decreasing linear trend because of its same relative permittivity and conductivity. The radar signal after depth-normalization, can then be interpreted as being principally influenced by the content of chlorides penetrating cover concrete, which caused corrosion of rebars in bridge decks.

An Experimental Study on the Fundamental Properties and Durability of Sewer Type Restorative Mortar Spread with Antibiotics (항균제를 도포한 하수시설용 단면복구 모르타르의 기초물성 및 내구특성에 관한 실험적 연구)

  • Kim, Moo-Han;Kim, Gyu-Yong;Kim, Jae-Hwan;Cho, Bong-Suk;Lee, Dong-Heck
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.3
    • /
    • pp.195-202
    • /
    • 2006
  • Deterioration of sewer concrete is representative that biochemical corrosion according to the $H_2S$ has growth by inhabit sulfur-oxidzing bacteria because of special environment in sewer. But in case of domestic, fundamentally, sulfur-oxidzing bacteria could moderate development of repair material method is need because of corrosion prevent method is inconsideration with carry out to improve project. In this paper, after development of spread type antibiotic with antibio-metal, antibacterial performance about sulfur-oxidzing bacteria of antibiotic and tested to estimate fundamental properties of bonding strength, abrasion contents, contents of water absorption, contents of air permeability, carbonation depth, chloride ion penetration depth and chemical resistance of spread with antibiotic restorative mortar.

A Study on The Corrosion Resistance of Concrete Containing Copper Slag (동제련 슬래그 혼입 콘크리트의 부식 저항성에 관한 연구)

  • Lee, Dong-Un;Jung, Yoo-Jin;Kim, Young-Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.189-196
    • /
    • 2007
  • The purpose of this study was to analyze steel corrosion resistance of concrete containing copper slag. The specimens were made with normal portland cement and pozzolan materials with various replacement ratio and with W/B ratio ranging from 35% to 55%. Compressive strength, coefficient of chloride diffusion, corrosion area ratio and weight reduction ratio were determinated for the test. The results show that the concrete with pozzolan materials is superior resistant to chloride ions compared to the concrete without pozzolan materials. It was observed that blast furnace slag replacement ratio of 20% gives the best results with respect to chloride ion penetration and corrosion tests and observed that copper slag replacement ratio of 10% gives the seperior resistance compared to normal concrete.

Influence of Hydrostatic Pressure on Chloride Ion Penetration of Marine Concrete (정수압이 해양콘크리트의 염화물이온 침투에 미치는 영향)

  • Kim, Gyeong-Tae;Kim, Gyu-Yong;Nam, Jeong-Soo;Lee, Bo-Kyeong;Lim, Chang-Hyuck
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.78-84
    • /
    • 2019
  • The Marine concrete that located at immersion zone receives an hydrostatic pressure of 1 atm as depth of the water increased by 10 m. And it could accelerate chloride ion penetration. In this study, to evaluate the influence of hydrostatic pressure on chloride ion penetration, concrete mixed by ordinary Portland cement and Portland blast-furnace slag cement was exposed to 1 and 6 atm and substitute ocean water. As a result, the surface chloride ion concentration of the concrete under 6 atm of hydrostatic pressure increased rapidly and the water-soluble chloride ion contents was increased by depth. In addition, the concrete under 6 atm of hydrostatic pressure showed the increase of capillary pores corresponding to 5~100 nm.

Structural Performance of Permanent Steel Formed Wide Beams in Construction Stage (강재 영구거푸집 와이드 보의 시공단계 구조성능)

  • Yu Na Park;Inwook Heo;Jae Hyun Kim;Khaliunaa Darkhanbat;Sung-Bae Kim;Kang Su Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.130-138
    • /
    • 2023
  • In this study, experimental and analytical studies were conducted on the structural performance of permanent steel formed wide beams in construction stage. Four specimens were fabricated with different rib spacings of the side steel formwork and fixing plate depths, and experimental tests were performed to investigate the effects of variables on the structural performance. Also, an finite element analysis model of the steel permanent formwork wide beam was proposed based on the test results. Using the proposed model, parametric studies were performed with variables including rib spacing of the bottom and side steel formwork, spacing, depth, and thickness of the fixing plate to derive optimized details. Furthermore, an artificial neural network model was developed to easily estimate the deformation of the steel permanent formwork wide beam with various details.

Chloride Penetration Analysis of Fly Ash Concrete using Potentiometric Titration and XRF (플라이애시를 혼입한 콘크리트의 전위차 적정법과 XRF를 이용한 염화물 침투 분석 )

  • Eun-A Seo;Ji-Hyun Kim;Ho-Jae Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.16-22
    • /
    • 2023
  • In this study, a salt water immersion test was performed on concrete specimens simulating the concrete mix design of the nuclear power plant, and the correlation between the amount of chloride and the XRF component according to the depth of the concrete was analyzed. The amount of chloride on the surface of the nuclear power plant concrete increased slightly with increasing immersion time in salt water, but the amount of chloride in the depth of 5.5 mm or more showed a clear tendency to increase with increasing immersion time in salt water. As a result of analyzing the correlation between the amount of chloride in concrete and the XRF component, the concrete with 20% FA substitution compared with the OPC concrete showed a very high correlation between the composition ratio of Cl ions and the evaluation result of salt damage resistance by XRF component analysis. Accordingly, it was confirmed that chlorine ion analysis and salt damage resistance performance evaluation by XRF component analysis were possible through repeated data accumulation in the nuclear power plant concrete mix with 20% fly ash replacement.

Dynamics of $NO_3^{-}$-N in Barley Rhizosphere and Optimum Rate of Nitrogen Top- Dressing Based on $N_{min}$ Soil Test (실초태 실소 의 보리 근권토양내 동적 변화와 $N_{min}$ 토양진단법에 의한 과정 실소추식량 결정)

  • 손상목;큐케마틴;한인아
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.40 no.2
    • /
    • pp.185-194
    • /
    • 1995
  • The prevention of excessive use of nitrogen fertilizer get an attention in Korea not only for minimizing $NO_3^-$ contamination of groundwater but also for establishment of environmental friendly sustainable agriculture. In order to find out the dynamics of $NO_3^-$ in barley rhizosphere and its suitability for nitrogen fertilization strategies and for environmental control, the accumulation of $NO_3^-$ in 3 layer, 0~30cm, 30~60cm, 60~90cm of soil profile has been detected in winter barley pro-duction system. It showed the recommended N fertilization rate for winter barley cause the $NO_3^-$ contamination of groundwater through $NO_3^-$ leaching during winter. The $NO_3^-$ content of 0~90cm soil depth have directly reflected the amount of basal N fertilization in the early spring, but not 0~30cm and 0~60cm soil depth. The contents of $NO_3^-$ measured to 0~30cm, 0~60cm soil depth were not significanly correlated with yield but the contents of $NO_3^-$ measured to 90cm soil depth was highly correlated with yield. Nitrogen fertilizer requirement could be estimated accurately by soil test and it provides field specific N rate recommendation for spring N application to winter barley. It was concluded that $N_{min}$ method could be applied to korean climatic and soil condition for optimal fertilizer application rate.

  • PDF

Incidence and Risk Factor of Pneumothorax After Percutaneous Fine Needle Aspiration Biopsy of the Lung (경피폐세침흡인생검시 기흉의 발생빈도와 위험인자)

  • Choi, Cheon Woong;Yoo, Jee Hong;Chin, Hyoun Jung;Park, Myoung Jae;Kang, Hong Mo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.6
    • /
    • pp.628-637
    • /
    • 2004
  • Background : Percutaneous needle aspiration biopsy(PNAB) of the lung is a safe procedure for diagnosis of various pulmonary diseases but complications such as pneumothorax can occasionally develop. We reviewed the complications arising after PNAB and analysed the risk factors of pneumothorax. Method : We collected data by reviewing medical records and radiographic studies of 403 patients who underwent PNAB of the lung between 1988 and 2002 and analyzed the risk factors of pneumothorax. Result : The incidence of complication was 12.9%, 48 patients with pneumothorax and 4 patients with mild hemoptysis. Among the 48 pneumothorax patients, 35 patients showed mild(<20%) and was treated by only oxygen supply, 11 patients had severe pneumothorax(>50%) and chest tube insertion was done and 2 patients were treated by needle aspiration. As the results of multivariate analysis, size and location of lesion, location of approach, diagnosis of lesion showed no significant relationship, while age and gender of patients(p<0.05) and the depth of approach(p<0.001) were significantly related to pneumothorax. Smoking amount(p<0.001) as well as the smoking history(p<0.005) were also significantly related and the examiner displaying various incidence of pneumothorax from 4.0% to 23.1% among individuals also was a significant independent risk factor(p<0.05). While the average depth of approach for 13 patients treated by chest tube insertion or needle aspiration was $8.2{\pm}1.2cm$, 35 patiens treated only by oxygen supply was $6.7{\pm}1.6cm$ suggesting that the depth of approach was lead to a severe pneumothorax. Conclusion : The independent risk factors of pneumothorax, the most common complication after PNAB, are age and gender of patients, depth of approach, examiner of procedure, smoking history and smoking amount.

Imaging Magnetic Flux Leakage based Steel Plate Damage for Steel Structure Diagnosis (강구조물 진단을 위한 누설자속 기반 강판 손상의 이미지화)

  • Kim, Hansun;Kim, Ju-Won;Yu, Byoungjoon;Kim, Wonkyu;Park, Seunghee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.129-136
    • /
    • 2019
  • In this study, the magnetic flux leakage technique was applied to diagnose steel plate damage, imaging technique was applied through those signals. Steel plate specimens with different thicknesses were prepared for the imaging the magnetic flux leakage signal, and 6 different depths of damage were artificially processed at the same locations on each specimen. The sensor head consist hall sensor and magnetization yoke was fabricated to magnetize the steel plate specimen and measure the magnetic flux leakage signal. In order to remove the noise and increase the resolution of the image in the signal collected from the hall sensor, various of signal processing was performed. P-P value was analyzed for each channel to analyze the magnetic flux leakage signals measured from each damaged part. Based on the above processed signals and analysis, it was converted into heatmap image. Through this, it was possible to identify the damage on the steel plate at glance by imaging magnetic flux leakage signal.

Study on the Usefulness of Using Anterior and Posterior Views for Calculation of Total Relative Uptake Ratio in 99mTc-DMSA Renal Scan (99mTc-DMSA 검사에서 상대 신섭취율 산출 시 양면상 촬영의 유용성에 대한 고찰)

  • Kim, Joo-Yeon;Lee, Han-Wool;Kwon, O-Jun;Kim, Jung-Yul;Park, Min-Soo;Cho, Seok-Won;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose $^{99m}Tc-DMSA$ renal scintigraphy serves as location, size and shape of kidney, so it has been used for diagnosis and passage observation after the operation or treatment. There are 3 methods of calculating the relative renal uptake ratio such as geometric mean of the counts from the anterior and posterior views, arithmetical mean from the only posterior view and posterior view which applied the renal depths. In this study, we seek to correlation between the change of total relative uptake ratio according to different inspection methods of obtaining the renal count rate. Materials and Methods The phantom experiments proceeded 5 times depending on each renal depth with the kidney phantom and tissue equivalent materials. In the clinical research, we investigated 36 adult patients who had visited our hospital from february to october, 2014 and received $^{99m}Tc-DMSA$ renal scan. The equipment was used as a gamma camera named INFINIA (General Electric Healthcare, milwaukee, USA) and we drew the region of interests through semiautomatic method by using Xeleris Ver. 2.1220 of GE. In addition, we obtained the lateral view of kidney to measure the renal depth of each patient. Then the results were compared with 3 methods of calculating relative renal uptake ratio. Results The phantom studies show when the difference between the left ant right kidney depth were less than 1 cm, there were no statistically significant difference among values calculated through anterior and posterior views and only posterior view (P>0.05), while the excess of 1cm, the results showed a statistically significant change in the value (P<0.05). In case of clinical research, the correlation between total relative uptake ratio by obtaining both sides of image and posterior view applied the kidney depth (r=0.999) was higher than by obtaining only posterior view and applying the kidney depth to one side image (r=0.988). Conclusion This study has found that, the difference of calculating total relative uptake ratio compared with obtaining anterior and posterior views and only posterior view. In order to reduce the error, we recommend the method of obtaining anterior and posterior views and is considered to be useful, particularly the patients have similar uptake ratio of left and right kidney and difficulties of measurements of kidney depth.

  • PDF