Analysis of THD according to Output Power Fluctuation of Photovoltaic Generation System using Real Time Simulator (실시간 시뮬레이터를 이용한 태양광 발전 시스템의 출력 변동에 따른 THD 분석)

  • An, Hee-Jin;Seo, Hun-Chul;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.361-366
    • /
    • 2012
  • This paper analyzes the THD(Total Harmonics Distortion) according to output power fluctuation of photovoltaic(PV) systems using real time simulator. For being close to reality, the PV system including inverter and MPPT(Maximum Power Point Tracking) which composed of closed-loop using real-time simulator are modeled. The change of irradiance and temperature of PV module is modeled to consider the change of weather. The various simulations according to the weather conditions are performed and THD is calculated at each condition. In this paper, the results by off-line simulation are compared with the ones of real time simulation.

A Study on the Determination of the Transient Performance for Protective Current Transformer (보호용 CT의 과도 성능 검증에 관한 연구)

  • Kim, Dong-Su;Park, Nam-Ok;Kim, Chul-Hwan;Ryu, Jae-Nam
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1727-1732
    • /
    • 2010
  • The Current transformer is classified measuring CT and protective CT for their purpose. The measuring CT is required to retain a specified accuracy over the normal range of load currents, but the protective CT must be capable of providing an adequate output over wide range of fault condition. Therefore, the protective CT must determine the transient performance during fault condition. This paper measured peak instantaneous error of the TPY class CT to determine the transient performance directly and indirectly and studied the test results.

Analysis on the Protective Coordination in Power Distribution System with Superconducting Fault Current Limiter (배전계통에 초전도 전류 제한기 적용시 보호협조 분석)

  • Ahn, Jae-Min;Kim, Jin-Seok;Moon, Jong-Fil;Lim, Sung-Hun;Kim, Jae-Chul;Kim, Chul-Hwan;Hyun, Ok-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.755-760
    • /
    • 2008
  • The increase of fault current due to larger power demand has caused the capacity of power machines in grid to increase. To protect the power system effectively from the larger fault current, several countermeasures have been proposed. Among them, the superconducting fault current limiter (SFCL) has been expected as one of the most effective solutions. Therefore, to introduce SFCL into power distribution system, the analysis on protection in power distribution system with SFCL is essential. In this paper, the problems of the protective coordination in power distribution system with SFCL were described.

An Adaptive Reclosing Technique Considering the Distributed Generation (분산전원을 고려한 적응적 재폐로 기법)

  • Seo, Hun-Chul;Kim, Chul-Hwan;Yeo, Sang-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.227-232
    • /
    • 2007
  • The autoreclosing is applied to power system for maintaining system stability and continuity of supply. Developments on distributed generation(DG) grows significantly by environmental issues and economical issues. If the DG is connected to distribution system, the DG influences the technical aspects such as power quality, protection and stability. It causes the challenges to protection, especially to reclosing. In order to achieve reliability and safety of the distribution system, the rules and guidelines suggest that the DG units should be rapidly disconnected from the network before the reclosing. If the DG is disconnected whenever the fault occurs, it cannot be utilized effectively. This paper presents the adaptive reclosing algorithm considering the DG. The algorithm consists of angle oscillation's judgment, EEEAC(Emergency Expanded Equal-Area Criterion), calculation of optimal reclosing time and re-connection algorithm. The simulation is implemented for the DG technology by using EMTP MODELS. The simulation results show that the transient stability is maintained and the DG is protected against disturbance.

Implementation of Frequency Relaying Algorithm based on Multi-Agent System using EMTP-MODELS (EMTP-MODELS를 이용한 Multi-Agent System 기반의 주파수 계전 알고리즘 구현)

  • Lee, Byung-Hyun;Kim, Chul-Hwan;Yeo, Sang-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2072-2077
    • /
    • 2007
  • The primary objective of all power systems is to maintain the reliability and to minimize outage time for fault or the others. The frequency relaying algorithm perceives a variation of system frequency and thereafter detects the unbalance between generation and load. A multi-agent system is composed of multiple interacting computing elements that are known as agents. In this paper, frequency relaying algorithm is designed by multi-agent system and is implemented by EMTP-MODELS. To verify performance of the frequency relaying algorithm based on multi-agent system, simulations by EMTP have been carried out.

Limiting Current Characteristics using Superconducting Fault Current Limiter in Power System (배전계통에 초전도 한류기 적용시 전류제한특성)

  • Kim, Jin-Seok;Lim, Sung-Hun;Ahn, Jae-Min;Moon, Jong-Fil;Kim, Jae-Chul;Kim, Chul-Hwan;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.21-22
    • /
    • 2008
  • The increase of fault current due to larger power demand has caused the capacity of power machines in grid to increase. To protect the power system effectively from the increased fault current, the superconducting fault current limiter (SFCL) have proposed one of several countermeasures. Therefore, to introduce SFCL into power distribution system, the position of SFCL in power distribution system is selected among some cases. Each position changes fault current limiting characteristics and SFCL's requirement. In this paper, the characteristics of limiting fault current according to installed SFCL's location in power distribution system.

  • PDF

Analysis of the Transients during Energizing Transmission Lines using EMTP (EMTP를 이용한 시송전 계통의 송전선로 초기 가압시 과도현상 분석에 관한 연구)

  • Yeo, Sang-Min;Kim, Chul-Hwan;Lyu, Young-Sik;Joo, Haeng-Ro;Cho, Burm-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.185-186
    • /
    • 2008
  • 전력계통에서 고장과 같은 어떤 원인에 의한 전계통 정전 또는 광역정전이 발생하였을 경우, 빠른 시간 내에 다시 전력을 공급하기 위한 조치를 취해야 한다. 그러나 계통의 구성 형태, 부하 조건, 발전기의 종류 등에 의해 계통 복구시 부하 투입에 의한 발전기 응동, 송전선로 가압시 선로 충전용량에 의한 과도현상 등 다양한 형태의 과도현상이 발생한다. 따라서 본 논문에서는 국내의 시송전 계통에서의 복구절차 수행시 송전선로를 가압할 때 발생하는 과도현상을 분석하였다. EMTP를 사용하여 시송전 계통을 모델링하였으며, 선로 가압에 의한 과도현상을 분석하였다.

  • PDF

A Study on the Standards for measuring insulating distances of low voltage equipments (저압기기의 절연거리 측정에 관한 규격 고찰)

  • Ahn, Sang-Pil;Park, Nam-Ok;Park, Seong-Hoon;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.691-692
    • /
    • 2008
  • 저압기기는 사용자의 조작과 밀접한 연관이 있어서 항상 안전성에 중점을 두고 있다. 이에 따라 관련 제품규격에서도 안전에 관련된 시험 요구사항 개발이 최근 들어 늘어나고 있다. 특히 절연과 관련된 시험 요구사항 중 기본 절연거리에 대한 규정은 저압기기의 역사와 같이 해왔으며, 매우 중요한 요구조건이다. 그럼에도 불구하고 최근 저압기기의 소형화와 전자부품화에 따라 절연거리의 측정에 관련된 규칙이 매우 복잡하고 다양화되었다. 이에 본 논문에서는 차단기류 제품규격을 중심으로 하여 절연거리 측정과 관련된 시험규격 및 방법을 고찰해 보고, 실제 진행된 국제비교숙련도 시험의 개요도 간단히 소개하고자 한다. 정리된 규칙들은 연구원들이 대부분의 저압기기의 절연거리 측정에 공통적으로 적용하여 저압기기 개발 시 유용하게 활용할 것으로 기대한다.

  • PDF

An Investigation on the Service Classification for Low-Voltage Circuit-Breakers according to the Korea Electric Power Industry Codes and Standards (전기설비기술기준 및 규격에 따른 저압차단기 용도구분에 대한 고찰)

  • Ahn, Sang-Pil;Park, Nam-Ok;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.693-694
    • /
    • 2008
  • 현재 국내에 사용되는 저압차단기는 산업용과 가정용 구분 없이 사용되고 있으며, 이를 전기설비기술기준은 물론 안전인증 제도로써도 강제할 만한 규정이 없는 실정이다. 그러나 일본을 비롯한 전세계적으로 대민 안전이 염려되는 가정용의 경우에는 시험 및 성능의 요구조건이 더 높아서 차단기의 사용도 가정용과 산업용으로 구분하는 추세이다. 본 논문에서는 현재 전기설비기술기준과 규격을 고찰하여 이러한 문제를 제기하고 향후 나아가야 할 방향을 제안하였다.

  • PDF

The Modeling of Induction Disc Type OverCurrent Relay using EMTP (EMTP를 이용한 유도 원판형 과전류 계전기 모델링)

  • Seong, No-Kyu;Yeo, Sang-Min;Rhee, Sang-Bong;Kim, Chul-Hwan;Jung, Chang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.119-120
    • /
    • 2008
  • 본 논문은 배전계통에서 사용되고 있는 유도 원판형 과전류 계전기를 EMTP(ElectroMagnetic Transients Program)을 이용하여 모델링 하였다. EMTP 내의 TACS 소자는 동적 응답 특성을 모델링 할 수 있는 소자로 유도 원판형 계전기의 동적 응답 특성을 모델링하는데 사용되었다. 계전기의 순시동작 및 한시동작 특성은 한국전력공사 과전류 계전기 표준규격에 근거하여 모델링하였으며, 순시동작 및 한시동작 (반한시, 강반한시) 특성을 모두 모델링하였다. 또한 한국전력공사 실 배전계통에 투입하여 고장 발생 시 계전기 동작을 관찰함으로써 모델링한 계전기의 동작을 검증하였다.