• Title/Summary/Keyword: 김철환

Search Result 830, Processing Time 0.05 seconds

The Pilot experiment set to track the Output of Photovoltaic System (태양광 발전 추적을 위한 Pilot 장치 실험 세트)

  • Seo, Hun-Chul;Kim, Sang-Hyub;Kim, Chul-Hwan;Yoon, Young-Min
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.478_479
    • /
    • 2009
  • It is important to find the maximum efficient conditions for the output of the photovoltaic(PV) system to determine the optimal installation location of the PV system. The output of PV system depends on the irradiance. Therefore, this paper introduces the pilot experiment set to track the output of PV system according to the variance of irradiance and analyzes the result of experiment using this set. The pilot experiment set consists of the PV modules and the inverter to convert DC power to AC power. For this experiment, the fixed and tracked modules are used.

  • PDF

Analysis of the Effect of Low Pass Filter for Active Filter in Distribution System (배전계통에서의 능동 필터에 대한 LPF의 영향 분석)

  • Park, Gwang-Won;Kim, Hyoun-Su;Kim, Chul-Hwan;Lyu, Seung-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.221_222
    • /
    • 2009
  • 최근 전력 컨버터 사용의 증가로 배전계통에서의 고조파 왜곡이 날로 심각해지고, 따라서 고조파에 민감한 전력계통 기기와 고객 부하를 보호하기 위한 고조파 저감대책이 필요하다. 본 논문에서는 능동 필터와 Low-Pass Filter(LPF)를 전력계통 과도해석 프로그램인 Electro-Magnetic Transients Program(EMTP) 내의 Transients Analysis of Control Systems(TACS) 소자를 사용하여 모델링하고 고조파 발생시 능동필터에 LPF의 설치 유/무에 따른 배전계통에서의 상전류와 중성선 전류의 변화를 분석하였다.

  • PDF

The Undervoltage Protection of Distribution System with Photovoltaic System (태양광 연계 계통의 저전압 보호 기준 정립)

  • Seo, Hun-Chul;Kim, Chul-Hwan;Yoon, Young-Min
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.438_439
    • /
    • 2009
  • This paper analyzes the undervoltage protection based on the dynamic stability of a PV system at fault conditions. A 3 MW PV system is modeled by Matlab/Simulink. Then, the distribution system interconnected with the PV system is modeled. This paper simulates the various fault types and analyzes the stability of the PV system at fault conditions. It is concluded that the undervoltage protection of the grid-connected PV system in Korea standard needs to be modified based on the results of the stability analysis.

  • PDF

The Frequency Protection of Distribution System with Photovoltaic System (태양광 연계 계통의 주파수 보호 기준 정립)

  • Seo, Hun-Chul;Kim, Chul-Hwan;Yoon, Young-Min
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.440_441
    • /
    • 2009
  • The standard for the frequency protection of distributed generation in Korea Electric Power Corporation (KEPCO)'s standard doesn't include the setting of frequency protection. Therefore, this paper analyzes the correlation between the frequency protection requirements and the stability of grid-connected PV system for the adjustable operating setting of frequency protection. The distribution system interconnected with 3 MW PV system is modeled by Matlab/Simulink. The various value of frequency is simulated. For studied cases, the stability of PV system is analyzed. It is concluded that the operating setting of frequency protection can be determined by the stability of PV system.

  • PDF

Development of new reclosing scheme considering the superconducting fault current limiter (초전도 한류기를 고려한 재폐로 차단기 동작 scheme 개발)

  • Ko, Yun-Tae;Seo, Hun-Chul;Rhee, Sang-Bong;Kim, Chul-Hwan;Kim, Jae-Chul;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.135_136
    • /
    • 2009
  • This paper proposes the new reclosing scheme considering the recovery time of SFCL in distribution systems which is based on variable dead time control. The main idea is that it uses the carrier signal to distinguish whether the fault is instantaneous or permanent following initial recloser opening. The system and SFCL is modeled by using Electromagnetic Transient Program(EMTP) and the validity of the reclosing scheme represented in this paper is analyzed according to the value of the fault resistance and the time of the fault removal.

  • PDF

Analysis of the Protective Coordination considering the superconducting fault current limiter in Distribution System with Distributed Generation (분산전원 연계 계통에 초전도한류기 적용 시 보호협조 분석)

  • Seo, Hun-Chul;Ko, Yun-Tae;Rhee, Sang-Bong;Kim, Chul-Hwan;Kim, Jae-Chul;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.137_138
    • /
    • 2009
  • The increasing of fault current by introducing of the distributed generation(DG) in distribution system disrupts the protective coordination. Therefore, this paper applies the superconducting fault current limiter(SFCL) to solve this problem. The distribution system with DG and SFCL is modeled by EMTP. According to various size of the DG, the fault is simulated and the operating time of overcurrent relay is investigated accoring to the resistance of SFCL.

  • PDF

The Characteristic Analysis of Frequency Propagation on Disturbance in Transmission System (외란에 따른 송전계통의 주파수의 변화와 전파특성 분석)

  • Shin, Dong-Kwang;Yeo, Sang-Min;Lee, You-Jin;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.231_232
    • /
    • 2009
  • 주파수는 전력품질을 평가하는 중요한 지표이다. 따라서 주파수를 일정하게 유지하면서 전력시스템의 신뢰도와 안정도를 높이는 연구가 필요하다. 따라서 본 논문에서는 ATPDraw로 구성된 한국의 765kV 송전계통을 5개 지역으로 구분하여 1개 변전소(S/S)에서 계통의 부하투입을 모의하고, 모의결과를 이용하여 4개 지역의 송전선로의 거리와 부하 용량에 따른 주파수 전파특성을 분석하였다. 분석결과 주파수 전파특성은 외란발생지점에서부터의 거리와 용량에 따라 주파수 변화가 다름을 알 수 있었다.

  • PDF

A Control Scheme of Recloser for Asymmetrical Fault Current Reduction (비대칭 고장전류 저감을 위한 재폐로 차단기 제어 방안)

  • Rhee, Sang-Bong;Kim, Chul-Hwan;Seo, Hun-Chul;Ko, Yun-Tae;Kim, Kyu-Ho;Kim, Jae-Chul;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.215_216
    • /
    • 2009
  • This paper presents a asymmetry fault current reduction scheme with recloser operation during transient period. The principle of asymmetry current nature is reviewed and asymmetry components reduction with recloser operation is explained. Throughout the simulation, results verifies the proposed scheme for recloser operation and its effectiveness.

  • PDF

The Modeling of Overcurrent Relay with Reclosing using EMTP (EMTP를 이용한 재폐로부 과전류계전기 모델링)

  • Lim, Kyung-Sub;Seong, No-Kyu;Yeo, Sang-Min;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.209_210
    • /
    • 2009
  • 계전기는 1930년대에 처음 개발되어 지금까지 수많은 발전을 거치며 전력계통의 과도현상을 효과적으로 차단해왔다. 이러한 계전기의 종류에는 많은 종류가 있으며 본 논문에서는 배전선로 보호에 주로 쓰이는 재폐로부 과전류계전기에 대한 연구를 수행하였다. 배전계통에 사용하는 과전류계전기는 이상전류가 발생할 경우 순시특성과 한시 특성을 이용하여 계통을 차단하지만 고장검출시간은 비교적 짧은 편이다. 이런 현상은 짧은 시간 안에 발생하는 이상전류에 대해서도 계통을 정전상태로 만들기 때문에 효율적이지 못하다. 따라서 이러한 문제점을 해결하고자 재폐로부 과전류계전기가 개발되어 재폐로의 특징을 이용해 좀 더 긴 고장검출 시간을 확보하여 계통의 불필요한 정전을 방지하고 있다. 본 연구에서는 재폐로부 과전류계전기를 EMTP를 이용하여 모델링하고 계전기 동작을 검증하였으며 또한 EMTP를 이용하여 모델링된 배전계통에 적용시켜 모의결과를 분석하였다.

  • PDF

Analysis of the Traveling Wave for Ultra High Speed Distance Relaying on Transmission Lines (송전선로의 고속도 거리계전을 위한 진행파 해석)

  • Yeo, Sang-Min;Kim, Chul-Hwan;Yang, Jung-Jae;Lyu, Young-Sik;Joo, Haeng-Ro
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.30_31
    • /
    • 2009
  • 송전선로에서 고장이 발생할 경우 가능한 빠르게 고장을 검출하고 고장점을 파악하여 수리하는 것은 전력 공급의 신뢰도 및 전력품질 향상에 매우 중요하다. 고장점 추정을 위한 방법은 크게 전압과 전류의 기본파를 이용한 임피던스 계산 방법과 과도신호에 기반한 진행파 해석 방법으로 분류할 수 있다. 과도신호에 기반한 진행파 해석 방법은 매우 빠른 응답을 갖는다는 장점을 갖고 있으나 진행파의 특징을 추출하여 고장거리를 계산하는데에는 어려움이 따른다. 따라서 본 논문에서는 송전선로에서 고장이 발생할 경우 나타나는 진행파의 특징을 분석하고 진행파로부터 고장점 정보를 추출하기 위한 방법을 제시하였다.

  • PDF