• 제목/요약/키워드: 김영기

검색결과 943건 처리시간 0.027초

수직다발관형 빙축열 탱크내 물의 응고과정시 열전달특성에 관한 연구 (An Experimental Study on the Heat Transfer Characteristics during the Freezing Process of Water in the Vertical Multi Tube Type Ice Storage Tank)

  • 김영기;임장순
    • 태양에너지
    • /
    • 제18권3호
    • /
    • pp.95-105
    • /
    • 1998
  • In this study, basic design data which were required for development of highly efficient ice storage system with low temperature latent heat were experimentally obtained. The ice storage system considered in this study was the one that has been widly used in the developed country and called the ice-on-coil type. Using the system, the ice storage performance for various design parameters which were the flow direction and the inlet temperature of the secondary fluid was tested. In addition, the timewise variation of the interface profiles between the solid and the liquid were visualized, and the heat transfer characteristics of the Phase Change Material(PCM) in the ice storage tank were Investigated. During the freezing processes in the ice storage tank with several vertical tubes, decrease of the heat transfer area and the heat resistance of the ice layer made the increasing rate of ice packing factor(IPF) less. The total freezing energy for the upward flow of the secondary fluid was higher than that for the downward flow. The average ice storage efficiency for the upward flow of the secondary fluid was higher than that for the downward flow.

  • PDF

개에서 농흉증의 영상의학적 접근 (Medical Imaging of Pyothorax in a Dog)

  • 최호정;이영원;박기태;왕지환;김영기;연성찬;이효종;이희천
    • 한국임상수의학회지
    • /
    • 제27권1호
    • /
    • pp.107-112
    • /
    • 2010
  • A 3-years-old female Pointer was evaluated for anorexia, dyspnea and exercise intolerance for 10 days. Auscultation revealed muffling of heart sound. There were leukocytosis, anemia, hypoalbuminaemia and hyperglobulinaemia on the blood profiles. Radiography showed severe pleural effusion. Thorax ultrasonographs described traped pleural effusion, pericardial effusion and collapsed right lung lobe(s). On CT images, thoracic neoplasia and lung torsion were ruled-out. Thoracocentesis with thoracoscopy and bacterial culture revealed pyothorax and pleuritis. The diagnosis of pyothorax in dogs and cats is based on clinical signs, radiography, thoracocentesis and cytology and culture of the exudate. In this case, various diagnostic medical imaging techniques (radiography, ultrasonography, CT and thoracoscopy) were used for diagnosis of pyothorax.

버즘나무방패벌레(Corythucha ciliata)의 배자발육과 후배자발육에 미치는 tebufenozide의 영향 (Effect of tebufenozide on embryonic and postembryonic development of sycamore lace bug, Corythucha ciliata(Hemiptera: Tingidae))

  • 최미현;김정화;김길하
    • 농약과학회지
    • /
    • 제3권2호
    • /
    • pp.74-80
    • /
    • 1999
  • 버즘나무방패벌레(Corythucha ciliata)에 대한 비스테로이드성 탈피호르몬 작용제인 tebufenozide가 배자 발육과 후배자발육에 미치는 영향을 조사하였다. Tebufenozide가 알에 대해서 살란효과를 보였으며($LC_{50}=4.0$ ppm), 약충의 영기별 감수성은 차이가 없었다($LC_{50}=2.3{\sim}6.0$ ppm). Tebufenozide를 종령 약충에 처리했을 때 우화율, 수명 및 생식력은 농도가 높을수록(10 ppm) 감소하였다. 우화후 시일 경과에 따른 약제 처리효과에서 농도가 높을수록 산란전기는 지연되었고 성충수명, 산란수 및 부화율은 반대로 감소하는 경향을 보였다. 또한 난소발육도 억제되었다.

  • PDF

포텐셜을 기저로 한 패널법에 의한 프로펠러의 비정상유동해석 (Prediction of Unsteady Performance of a Propeller by Using Potential-Based Panel Method)

  • 문일성;김영기;이창섭
    • 대한조선학회논문집
    • /
    • 제33권1호
    • /
    • pp.9-18
    • /
    • 1996
  • 본 논문은 불균일한 선미 유동장에서 작동하는 프로펠러의 성능 해석을 위한 포텐셜을 기저로 한 판요소법을 기술하고 있다. 본 방법은 법선 다이폴과 쏘오스를 프로펠러의 날개, 허브, 그리고 후류면에 분포하였고, 비정상 유동의 해석 방법으로는 시간 전진법에 의한 방법을 취함으로써 다이폴의 세기를 미지수로 하는 적분방정식을 얻고, 이산화하여 수치적으로 계산하였다. 2차원 날개에 대한 수치해석을 수행하여 해석해와 비교함으로써 시간간격에 대한 수렴성을 확보하였다. 또한, DTRC 4118 프로펠러에 대하여 조화반류하에서 작동하는 프로펠러의 비정상 성능을 해석하여 실험치와 비교함으로써 시간영역에서 프로펠러의 비정상 성능해석이 가능함을 보였다.

  • PDF

이동 에이전트를 이용한 협력적인 모니터링 에이전트의 설계 및 구현 (Design and Implementation of Cooperative Monitoring Agent using Mobile Agent)

  • 김영기;한선관
    • 정보교육학회논문지
    • /
    • 제4권1호
    • /
    • pp.24-31
    • /
    • 2000
  • 이 논문은 교육용 포탈 사이트의 사라진 사이트(Dead Site) 필터링을 위한 상호 협력적인 모니터링 에이전트의 설계 및 구현에 관한 연구이다. 일반적으로 교육용 포탈 사이트는 선생님이나 개인적인 교육용 홈페이지의 주소를 많이 가지고 있다 그렇기 때문에 홈페이지의 주소를 일관성 있게 유지하는 것이 매우 어려우며 사라진 사이트를 포탈 사이트 관리자가 모두 찾아내는 경우는 거의 불가능하다. 따라서 본 연구에서는 이동 에이전트를 이용하여 사라진 사이트를 지능적으로 모니터링하는 상호 협력적인 모니터링 웹 에이전트를 설계, 구현하였다. 구현한 모니터링 에이전트는 한국형 교육 포탈 사이트인 KEPS에 탑제하여 그 성능을 실험하였으며, 일반 모니터링 시스템과 비교하여 그 효용성을 살펴 보았다.

  • PDF

4H-Pyran-4-one과 그의 황 유도체의 구조에 관한 이론적 연구 (Theoritical Studies on Structure of 4H-Pyran-4-one and Its Sulfur Analogues)

  • 이익춘;박형연;김영기
    • 대한화학회지
    • /
    • 제30권6호
    • /
    • pp.495-499
    • /
    • 1986
  • MNDO and MINDO/3 방법을 사용하여 평면분자인 4H-pyran-4-one(I), 4H-pyran-4-thione(II), 4H-thiapyran-4-one (III), 4H-thiapyran-4-thione(IV)의 구조를 결정하여 기하학적구조와 물리화학적 성질 특히 많은 논의의 대상이 되어온 방향적성을 연구하였으며 마이크로파 분광실험의 결과와 잘 일치함을 밝혔다. 방향족성의 크기는 (IV) > (III) > (II) > (I)의 순위이며 이것은 탄소원자보다 전기음성도가 월등하게 큰 산소원자가 전자 비편재화를 방해하는데 기인되는것이었고 또 쌍극자모멘트의 크기 순위는 (II) > (IV) > (I) > (III) 카르보닐기 (C=O 또는 C=S)의 길이순위임을 알았다

  • PDF

치조골이 감소된 지대치를 이용한 고정성 국소의치의 유한요소법적 응력분석 (FINITE ELEMENT STRESS ANALYSIS OF FIXED PARTIAL DENTURE SUPPORTED BY THE ABUTMENT WITH REDUCED ALVEOLAR BONE)

  • 김영기;최충국;정재헌
    • 대한치과보철학회지
    • /
    • 제33권1호
    • /
    • pp.32-47
    • /
    • 1995
  • The purpose of this study was to determine the displacement of prosthesis & abutment and the stress distribution patterns induced in the periodontium by applying force to the fixed prosthesis. Two levels of periodontal support were compared using two-dimensional finite element stress analysis after placement of 3unit or 4 unit fixed partial denture(FPD) in case of missing of the lower first molar. Concentrated vertical load was delivered at the cusp tip of the second bicuspid or the central fossa of the pontic. The following results were obtained : 1. The greater the loss of alveolar bone in abutment teeth area, the greater the displacement of FPD and the stress concentration in alveolar bone around abutment. 2. The amount and direction of displacement and distribution of stress in the 4-unit FPD was better than those in the 3-unit FPD. 3. Multiple abutments reduced the amount of mesial and downward displacement of the weaked abutments and more uniformly distributed the stresses.

  • PDF

고에너지 광자선에 대한 TRS-398 선질보정인자의 직접 계산 (Direct Calculation of TRS-398 Quality Correction Factors for High Energy Photons)

  • 신교철;오영기;김정기;김진기;김기환;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • 제17권1호
    • /
    • pp.54-60
    • /
    • 2006
  • IAEA TRS-398 프로토콜의 임상적 적용을 위하여 고에너지 광자선에 대한 선질보정인자를 직접 계산으로 결정하였다. 본 계산은 상용의 원통형 전리함 모델 7종(A12, IC70, N23333, N30001, N30006, NE2571, PR06C/G)에 대하여 수행되었다. 본 계산결과와 TRS-398의 자료를 비교할 때 대부분의 전리함 및 선질에서 ${\pm}0.3%$ 이내(최대 ${\pm}0.4%$)로 일치하였다.

  • PDF

메가소닉 세정시 발생되는 패턴손상 최소화에 대한 연구 (Evaluate the Effect of Megasonic Cleaning on Pattern Damage)

  • 유동현;안영기;안덕민;김태성;이희명;김정인;이양래;김현세;임의수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2511-2514
    • /
    • 2008
  • As the minimum feature size decreases, techniques to avoid contamination and processes to maintain clean wafer surfaces have become very important. The deposition and detachment of nanoparticles from surfaces are major problem to integrated circuit fabrication. Therefore, cleaning technology which reduces nanoparticles is essential to increase yield. Previous megasonic cleaning technology has reached the limits to reduce nanoparticles. Megasonic cleaning is one of the efficiency method to reduce contamination nanoparticle. Two major mechanisms are active in a megasonic cleaning, namely, acoustic streaming and cavitation. Acoustic streaming does not lead to sufficiently strong force to cause damage to the substrates or patterns. Sonoluminescence is a phenomenon of light emission associated with the cavitation of a bubble under ultrasound. We studied a correlation between sonoluminescence and sound pressure distribution for the minimum of pattern damage in megasonic cleaning.

  • PDF

가스보일러 코일형 열교환기의 열전달 특성에 관한 실험적 연구 (The Experimental Study on the Heat Transfer Characteristics)

  • 홍성혁;김영기;김일겸;김동춘;이창언;임장순
    • 태양에너지
    • /
    • 제17권4호
    • /
    • pp.57-66
    • /
    • 1997
  • The performance of gas-fired boilers were experimentally investigated. The heat exchanger used for the experiments consisted of circular tube with longitudinal fins for the gas side and a spiral coil for the water side. The burner was located at the top of the heat exchanger, and the burned gas flowed down to the exit. The experiments carried out for different water flow rates, the heat capacities of the boiler and the number of baffle. The thermal efficiency of the upward flow was higher than that of the downward flow of the water in the heat exchanger. As the boiler capacity increased, the thermal efficiency decreased. As the number of the baffles increase, the thermal efficiency increased and the increasing rate of the efficiency decreased. The gas-side overall heat transfer coefficient was independent of the flow rate of the water. The effect of the number of the baffles on the heat transfer coefficient was greater than that of the boiler capacity.

  • PDF