• Title/Summary/Keyword: 김두현

Search Result 335, Processing Time 0.02 seconds

A Detecting Method of Polymorphic Virus Using Advanced Virtual Emulator (개선된 가상 에뮬레이터를 이용한 다형성 바이러스 탐지 방법)

  • Kim, Du-Hyeon;Baek, Dong-Hyeon;Kim, Pan-Gu
    • The KIPS Transactions:PartC
    • /
    • v.9C no.2
    • /
    • pp.149-156
    • /
    • 2002
  • Current vaccine program which scans virus code patterns has a difficult to detect the encrypted viruses or polymorphic viruses. The decryption part of polymorphic virus appears to be different every time it replicates. We must monitor the behavior of the decryption code which decrypts the body of the virus in order to detect these kinds of viruses. Specialty, it is not easy for the existing methods to detect the virus if the virus writer has modified the loop count of execution intentionally. In this paper, we propose an advanced emulator using a new algorithm so as to detect various kinds of polymorphic viruses. As a result of experiment using advanced emulator, we found that our proposed method has improved the virus detecting rate about 2%. In addition, our proposed system has a merit that it runs on not only MS-Windows but also Linux, and Unix-like Platform.

Study on the Fabrication of Ceramic Core using a Gel-casting Process in Aqueous medium(I) : Gelation Behavior of Polydispered Ceramic Slip (수용액 매체에서 젤-케스팅 공정을 이용한 세라믹 코어 제조에 관한 연구(I) : 다성분계 분산 세라믹 슬립의 젤화 거동)

  • Kim, Jae-Won;Kim, Du-Hyeon;Kim, In-Su;Yu, Yeong-Su;Kim, Jae-Cheol;Jo, Chang-Yong
    • Korean Journal of Materials Research
    • /
    • v.11 no.2
    • /
    • pp.137-145
    • /
    • 2001
  • A new process, gelcasting in aqueous medium, to fabricate complex-shaped ceramic core has investigated. The ceramic slurry, mixture of fused silica powder and additives such as zircon and cordierite, was electrosterically stabilizes. The slip was prepared by ball milling of polydispered ceramic suspension with monomer, dimer and dispersant. The rheological behavior of slip was evaluated by viscosity measurement. It was found that the high solid loading of polydispersed ceramic slip, which has low viscosity of 50vol%, is possible to obtained. The viscosity of the slip was significantly dependent upon the amount of polymer dispersant and the formulation of monomer and dimer. The green bodies were fabricated through casting and gelation at room temperature followed by drying at $25^{\circ}C$ for 48hrs under relative humidity of 80~85%. Crack-free green body was successfully fabricated through the above process.

  • PDF

A Study on the Application of Aluminosilicate Sols in Shell Mold for Investment Casting ( I ) (정밀주조용 쉘 몰드에 알루미노실리케이트계 졸의 응용에 관한 연구 ( I ))

  • Kim, Jae-Won;Kim, Du-Hyeon;Seo, Seong-Mun;Jo, Chang-Yong;Choe, Seung-Ju;Kim, Jae-Cheol;Park, Yeong-Gyu
    • Korean Journal of Materials Research
    • /
    • v.9 no.12
    • /
    • pp.1188-1195
    • /
    • 1999
  • The effect of aluminosilicate sol on the formation of mullite layer in zircon shell mold was investigated. Aluminosilicate sol was prepared by mixing of colloidal silica(NALCO(R) 1130) and an aqueous solution of aluminium nitrate at room temperature. The sol gelled at 50$^{\circ}C$ for 48 hrs. It was identified that the gel consists of aluminosilicate complexes and gibbsite. The coordination number of all aluminium ion bonded with silicon ion was four. Mullite phase formed by sintering above 1300$^{\circ}C$. XRD peak of mullite sharpened with increasing sintering temperature and the content of aluminium nitrate. Mullite phase displayed whisker-like 0.5~5${\mu}m $ particles. Separation between 1st and 3rd layers during sintering and the difference in thermal expansion coefficient between residual silica and mullite.

  • PDF

Analysis of Comfortable Environment in the Classroom with Humidification and Ventilation in Winter (겨울철 가습 및 환기에 따른 교실내 쾌적환경 분석)

  • Cheong, Seong-Ir;Sheng, Nai-Li;Kim, Doo-Hyun;Lee, Jae-Keun;Hwang, Yu-Jin;Park, Jong-Hoon;Seo, Seok-Jang
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.7
    • /
    • pp.402-408
    • /
    • 2009
  • In this paper, the effects of ventilation and humidification on thermal comfort and indoor air quality(IAQ) were evaluated in a classroom when a heat pump system was operated in winter. Thermal comfort parameters, such as temperature, relative humidity, globe temperature and air velocity, were measured at 9 points in the classroom. The concentration of $CO_2$ and total suspended particles(TSP) in the classroom were measured in order to analyze IAQ. Temperature distribution in the classroom was decreased by $2{\sim}5^{\circ}C$ when the ventilation system and the humidifier were operated. When the relative humidity was adjusted to 60% by operating the humidifier and the ventilation system, the predicted mean vote(PMV) in the classroom was within the comfortable range of $-0.5{\sim}0.5$. When the ventilation system was operated, the average concentration of $CO_2$ and TSP were decreased by 645 ppm and 0.17 $mg/m^3$, respectively. This paper suggests the humidification and ventilation conditions to maintain the comfortable environment in the school classroom in winter experimentally.

Characteristics of Energy Consumption for a Household Refrigerator under Influence of Non-condensable Gases (가정용 냉장고의 불응축 가스량에 따른 소비 전력 특성)

  • Kim, Doo-Hyun;Hwang, Yu-Jin;Park, Jae-Hong;Chung, Seong-Ir;Jeong, Young-Man;Ku, Bon-Cheol;Lee, Jae-Keun;Ahn, Young-Chull;Bang, Sun-Wook;Kim, Seok-Ro
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.381-387
    • /
    • 2008
  • The presence of non-condensable gases as an additional thermal resistance inside a refrigerating circuit has been found for a general refrigerator, The effect of non-condensable gases was varied by controlling the injection amount of dry air into the refrigerating circuit to increase a thermal resistance. Energy consumption tests for the refrigerator were conducted under the various amounts of non-condensable gases. The tested refrigerating circuit was the household refrigerator. As the molar fraction of non-condensable gases was increased from 0% to 1.46%, the amount of energy consumption was found to increase up to 25%. The increase of the amount of non-condensable gases in refrigerating circuit was found to result in increasing the condensation temperature at the condenser and decreasing the evaporation temperature at the evaporator, which were presumably caused by the low specific heat and increased partial pressure of non-condensable gas.

Cryogenic Susceptibility Test for Long-term Storage of Tree Seed Genetic Resources (수목유전자원 종자의 장기저장을 위한 초저온 민감성 검정)

  • Kim, Min-Geun;Kang, Won-Sik;Kim, Du-Hyun;Woo, Kwan-Soo;Ku, Ja-Jung
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2019.04a
    • /
    • pp.82-82
    • /
    • 2019
  • 종자은행은 종자를 보존하는 가장 경제적이고 효율적인 보전방법이지만, 수종에 따라 저장특성의 차이가 커서 수종별 저장방법의 확립이 필요하다. 초저온저장 방법은 세포 분열, 대사 작용을 정지 상태로 유지하므로 현재까지 장기간 보존을 위한 비용이 효율적이며 안정적인 방법이다. 공시재료는 멸종위기 야생식물 등 22종을 대상으로 하였다. 액체질소에 7일간 종자를 침지한 후 $37^{\circ}C$ 항온수조에서 10분간 해동하였다. 휴면이 있는 수종은 파종 전 종자를 저온습윤 하였고, 저온습윤 처리 후에도 휴면타파 되지 않는 수종은 농황산, 지베렐린을 개별 또는 혼용으로 처리하였다. 발아 및 유묘 평가는 $25^{\circ}C/20^{\circ}C$(광12h/암12h)조건에서 진행하였으며, 매일 28일차까지 발아조사를 수행한 후 평가하였다. 진달래속의 꼬리진달래와 철쭉이 초저온 민감성을 보였으며, 오리나무속의 물오리나무, 사방오리는 부분 민감성을 보였다. 민산초나무는 지하부건물중이 유의하게 감소한 결과를 보였으며, 이외의 수종은 초저온 민감성을 보이지 않았으므로 장기보존을 위한 초저온 동결보존이 가능한 것으로 보였다.

  • PDF

Robust Design for Parts of Induction Bolt Heating System (유도가열시스템의 구성부품에 대한 강건설계)

  • Kim, Doo Hyun;Kim, Sung Chul;Lee, Jong Ho;Kang, Moon Soo;Jeong, Cheon Kee
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.10-17
    • /
    • 2021
  • This paper presents the robust design of each component used in the development of an induction bolt heating system for dismantling the high-temperature high-pressure casing heating bolts of turbines in power plants. The induction bolt heating system comprises seven assemblies, namely AC breaker, AC filter, inverter, transformer, work coil, cable, and CT/PT. For each of these assemblies, the various failure modes are identified by the failure mode and effects analysis (FMEA) method, and the causes and effects of these failure modes are presented. In addition, the risk priority numbers are deduced for the individual parts. To ensure robust design, the insulated-gate bipolar transistor (IGBT), switched-mode power supply (SMPS), C/T (adjusting current), capacitor, and coupling are selected. The IGBT is changed to a field-effect transistor (FET) to enhance the voltage applied to the induction heating system, and a dual-safety device is added to the SMPS. For C/T (adjusting current), the turns ratio is adjusted to ensure an appropriate amount of induced current. The capacitor is replaced by a product with heat resistance and durability; further, coupling with a water-resistant structure is improved such that the connecting parts are not easily destroyed. The ground connection is chosen for management priority.

Analysis of Worker Exposure Space according to Distribution of Electromagnetic Field of Generator (발전기의 전자기장 분포 특성에 따른 작업자 노출공간 분석)

  • Seong, Minyoung;Kim, Doo-Hyun;Kim, Seungtae
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.4
    • /
    • pp.20-28
    • /
    • 2021
  • With an increase in the commercialization of electricity, and the development of advanced and large electric devices and various wireless radio wave services, concerns over the effects of electromagnetic fields on human health have increased. Accordingly, the World Health Organization encouraged the development of international standards by establishing the 'International Electromagnetic Fields Project' in 1996 based on studies on the harmful effects of electromagnetic fields on the human body. Moreover, the National Institute of Environmental Health Sciences (NIEHS) classified electromagnetic fields as possible carcinogens under Group 2B category, even though they have been found to have a weak correlation with those effects on human health. Mid-to-large-sized electric facilities used at industrial sites mostly adopt a commercial frequency of 60 Hz, and workers handling these facilities are exposed to such extremely low frequency (ELF) fields for a long time. A previous study suggested that exposure to ELF electromagnetic fields with frequency ranges from 0 to 300 Hz, even for a short time, at densities higher than 100 μT may have harmful effects on human body as it affects the activation of nerve cells in the central nervous system by inducing an electric field and current and stimulating muscles and the nervous system in the body. Such studies, however, focused on home appliances used by ordinary people, and research on facilities utilizing high-capacity current and operated by workers at industrial sites is lacking. Therefore, in this study, a 3000 kilowatt generator, which is a high-capacity electric facility employed at industrial sites, was investigated, and the size of the magnetic fields generated during its no-load and high-load operations per distance to produce a map was measured to reveal spots deemed hazardous according to domestic and international exposure standards. The findings of this study is expected to alleviate workers' anxiety about the harmful effects of magnetic fields on their body and to minimize the level of exposure during operations.

Analysis of Failure and Electrical Fire for Bolt Induction Heating System Using FTA (FTA를 이용한 볼트 유도가열시스템의 고장 및 전기화재 분석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Eom, Haneol;Kang, Moon-Soo;Jeong, Cheon-Kee
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.4
    • /
    • pp.12-19
    • /
    • 2021
  • This paper presents a safety assessment method for FTA-based induction heating systems; the failures and causes of electrical fire are first analyzed for each part and module qualitatively, and methods to manage high probabilities of failure and electrical fire are considered, thereby improving the reliability of the induction heating system. The cumulative importance value (ACC) of the minimal cut set is drawn by setting failure as the top event, and STACK and SMPS are observed to account for about 70% of the induction heating system failures. Thus, intensively managing the basic events contained in the minimal cut set of failures for STACK and SMPS is expected to provide effective and stable operation of the induction heating system. When electrical fire is set as the top event, the STACK percentage is 90%. Accordingly, the current IGBT is changed to a FET to increase the applied voltage and prevent induction heating system failure, and a heat sink plane is installed to prevent FET heating caused by switching, thereby preventing an electrical fire. By classifying the parts and modules of the induction heating system in detail and by applying FTA based on actual failure rates and relevant data, more practical and reasonable results may be expected. Hence, continuous research must be conducted to ensure safety when using induction heating systems.

Analysis of Thermal Characteristic for Wiring at Heater Connector of Semiconductor Chiller Equipment (반도체 공정 칠러 장비의 히터 접속부 전기배선에 대한 열적 특성 분석)

  • Gyu Bin Kim;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.3
    • /
    • pp.27-34
    • /
    • 2023
  • With the technological development of the semiconductor industry, the roles of electrical and thermal energy supply and control of semiconductor equipment in ultrafine processes have become very important. However, instances of electrical fires in the chiller heater, which is used for cooling in the semiconductor manufacturing process, are increasing. A fire occurs in combustibles due to high heat at the connection part of the chiller heater, that is, when the number of electrical wires in the connection part is reduced or when the wires are completely disconnected. In this study, the temperature characteristics were compared and analyzed through experiments and 3D simulations. The number of electrical wires, which is the connection part of the chiller heater, was reduced by 90%, 50%, 30%, 10%, and 5%, and the wires were completely disconnected. When the number of electrical wires was reduced by 5%, heat of up to 80℃ was generated, which is a relatively high temperature but insufficient to cause a fire in combustibles. Complete disconnection occurred due to the vibration of the motor and other components, and sparks and arcs were generated, resulting in a rapid increase in temperature to up to 680℃. When completely disconnected, the temperature increase was sufficient to cause a fire in the combustibles covering the terminal block. Therefore, in this study, the causes of electrical fires in chiller heaters were investigated and preventive measures were proposed by analyzing abnormal signals and thermal characteristics caused by the electrical wiring being reduced and completely disconnected.