• Title/Summary/Keyword: 기포 거동

Search Result 131, Processing Time 0.024 seconds

An experimental study for boiling heat transfer enhancement under electric fields (전기장하에서의 비등 열전달 촉진에 관한 실험적 연구)

  • O, Si-Deok;Gwak, Ho-Yeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.7
    • /
    • pp.2298-2314
    • /
    • 1996
  • Electric field effect on boiling of refrigerants R11, R113, and FC72 has been investigated experimentally. One purpose of the experimental investigation is to determine the effects of the electrode arrangements on electrohydrodynamic boiling of the above mentioned liquids. The test equipment employed in the experiment consists of a shell and tube heat exchanger with six or six and twelve rows of electrode wires around the tube. It has been found that the applied voltage promotes the boiling heat transfer coefficient except FC72. Boiling heat transfer enhancement obtained is about 230% for R11, 280% for R113. It has also been observed that bubbles detached from the tube aggregate at the place where the electrical gradient force balances with the buoyancy one. These aggregated bubbles force to decrease the boiling heat transfer coefficient as well as to reduce the voltage needed to the dielectric breakdown.

Vibration Analysis for the Living Room Slab of Apartment (아파트 거실 바닥판에 대한 진동해석)

  • Kim, Yong-Tae;Park, Kang-Geun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.3 s.21
    • /
    • pp.93-101
    • /
    • 2006
  • Recently the floor vibration of apartment is often beginning to make its appearance of the environmental dispute, the standard floor system of housing are suggested for the settlement of this issue by government. For the slab vibration analysis on the laminated floor system of apartment, it is required the effectively analytical method of the floor system considering laminated theory. In this paper, more effective modeling methods of laminated floor slab are proposed for the method of accurate rigidity evaluation. By using the advanced modeling method, the more accurate vibration response can be obtained and can accurately evaluate the rigidity of living room floor system of apartment with different laminated materials.

  • PDF

Basic Investigation for the Development of Cleaning Technology with Ejector (이젝터를 이용한 세정기술 개발의 기초연구)

  • Park, Sang Kyoo;Yang, Hei Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.1
    • /
    • pp.29-36
    • /
    • 2017
  • The paper presents a basic investigation for the development of cleaning technology employing an annular nozzle ejector for application to cleaning water supply and air bubble generation. The quantitative flow characteristics of the primary and suction flows, the qualitative visualization behavior of the mixed jet, and the percentage concentration of pesticide residual at different values of the ejector screw pitch were investigated. It was seen that the primary flow rate increased, while the mass ratio decreased with increase in screw pitch. Further, the mixed jet behaved like a buoyancy jet or horizontal bubbly jet, and the residual concentration of pesticide first decreased and then increased with increase in screw pitch.

부분충수 운전중 잔열제거계통 기능상실사고에 대한 CATHARE2 코드의 민감도 분석

  • 정영종;김원석;장원표
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.48-54
    • /
    • 1996
  • 가압경수로의 부분충수 운전중 RHR 계통의 기능상실시 사고완화를 위해 가압기 manway와 증기 발생기 출구공동 manway를 동시에 개방한 경우에 대한 실험결과를 CATHAHR2 코드를 이용하여 해석하였다. 해석을 통해 이 경우에 발생하는 물리적 현상을 이해하고 이와 같은 과도기에 대해 코드 예측능력을 평가하므로 써, 실제 원전에서 사고시 적절한 사고대응 방안을 강구하는데 참고가 될 수 있도록 해석적 근거를 제시하고자 한다. 연구결과 CATHARE2 코드는 실험을 통해 관측된 주요 물리적 현상들을 타당하게 예측하였으나, 가압기와 밀림관의 DP를 과대 예측하여 원자로 상부공동의 최대압력을 실험보다 약 7kPa 높게 예측하였다. 노심 노출시간도 노심에서 기포율 분포를 비현실적으로 예측하여 실험보다 약 500초 지연되었다. 실험과 코드의 모의결과를 통하여 노심 노출은 중력주입에 의한 냉각수 보충만으로 충분히 회복될 수 있음을 확인하였다. CATHARE2 코드는 비록 상세한 현상들에 대해 다소 불확실성을 내포하였으나, 전반적인 거동분석에는 타당한 것으로 판단된다. CATHARE 코드는 노심에서 계면 마찰력을 줄임으로써 노심의 차압을 개선할 수 있었고, guide 튜브의 위치를 고온관 중심선과 일치시켜 guide 튜브내 액체의 hold-up 기간을 개선할 수 있었으며, 가압기의 계면 마찰력을 증가시켜서 밀림관에서 "plug and clearing" 현상을 모의할 수 있었다.모의할 수 있었다.

  • PDF

Studies on Physical Behavior of Alkyl Polyglucosides (I) - Interfacial Activities and Detergency - (Alkyl Polyglucoside 계면활성제의 물리적 거동에 관한 연구 (I) - 계면활성과 세정력에 관하여 -)

  • Yoon, Yeo-Kyung;Choi, Kyu-Suk
    • Applied Chemistry for Engineering
    • /
    • v.5 no.3
    • /
    • pp.451-456
    • /
    • 1994
  • Alkyl polyglucosides (APG), so called natural nonionic surfactants, are prepared with glucose from corn starch and fatty alcohol from palm and/or coconut oil. When we studied on interfacial properties of APG, surface and interfacial tension, cmc, foaming and effectiveness, according to degree of polymerization of glucose unit (D.P.=1.2~1.8) and alkyl chain length, the former hardly affects but the latter greatly affects on them. The order of detergency for fatty acid soils decreased as followings ; APG 0814> APG 1214> APG 10> APG 0810> APG 08, and the samples with lowest interfacial tension and maximum adsorption had a better detergency.

  • PDF

Experimental Study of the Ultrasonic Vibration Effects on CHF Occurring on Inclined Flat Surfaces (초음파 진동이 경사진 평판에서의 CHF에 미치는 영향에 대한 실험연구)

  • 정지환;김대훈;권영철
    • Journal of Energy Engineering
    • /
    • v.12 no.2
    • /
    • pp.139-144
    • /
    • 2003
  • Augmentation of CHF by ultrasonic vibration in water pool is experimentally investigated under pool boiling condition. The experiments are carried out using copper coated plates and distilled water. Measurements of CHF on flat plate heated surface were made with and without ultrasonic wave and with variations in inclined angle of the surface and water subcooling. Experimental apparatus consists of a bath, power supply, test section, ultrasonic generator, and data acquisition system. The measurements show that ultrasonic wave enhances CHF and its extent is dependent upon inclination angle as well as water subcooling. The rate of increase in CHF increases with an increase in water subcooling while it decreases with an increase in inclination angle. Visual observation shows that the cause of CHF augmentation is closely related with the dynamic behavior of bubble generation and departure in acoustic field.

Visualization Experiment for Nucleate Boiling Bubble Motion on a Horizontal Tube Heater Fabricated with Flexible Circuit Board (연성회로기판 기반 수평전열관 표면의 비등기포거동 가시화 실험 연구)

  • Kim, Jae Soon;Kim, Yu-Na;Park, Goon-Cherl;Cho, Hyoung Kyu
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.2
    • /
    • pp.52-60
    • /
    • 2016
  • The Passive Auxiliary Feedwater System(PAFS) is one of the advanced safety concepts adopted in the Advanced Power Reactor Plus(APR+). To validate the operational performance of the PAFS, detailed understanding of a boiling heat transfer on horizontal tube outside is of great importance. Especially, in the mechanistic boiling heat transfer model, it is important to visualize the phenomena but there are some limitations with conventional experimental approaches. In the present study, we devised a heater based on the Flexible Printed Circuit Board (FPCB) for a more comprehensive visualization and subsequently, a digital image processing technique for the bubble motion measurement was established. Using the measurement technique, important parameters of the nucleate boiling are analyzed.

Analysis of Strength Characteristics for Lightweight Soils Using Recycled Material (폐기물을 첨가한 경량혼합토의 강도특성 분석)

  • Bae, Yoon-Shin
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.3
    • /
    • pp.204-212
    • /
    • 2012
  • Lightweight soils are very economical and environment friendly materials that are valuable in field without wasting construction materials, dredged soils and clay/ silty soils during construction. Recently, the research of lightweight soils mixed with recycled material (recycled tire powder, rice husks) have been investigated. In this study the mix design factors (i.e., weight of soil, water content, foaming agent and added water) were analyzed and optimized mix design was suggested using cement content for revealing strength. For the analysis the stress-strain behavior, strength with respect to time, and experimental strength for the component of recycled material were analyzed. Finally, target strength was determined to calculate reasonable and economical mix ratio and the optimized cement content was suggested.

Swelling Behavior of Low Toxic Absorbent Based on Biopolymer (생물고분자로 이루어진 저독성 흡수제의 팽윤거동)

  • Jung, Jin Hee;Kim, Jin;Lee, Ki-Young
    • Polymer(Korea)
    • /
    • v.37 no.4
    • /
    • pp.478-485
    • /
    • 2013
  • In this study, hydrogels with fast swelling and high absorbent properties were prepared using biopolymers approved as a food additive and their swelling properties were characterized. To improve the swelling properties of conventional hydrogels, we formed gas bubbles using a foaming agent in the process of preparing hydrogels and characterized in terms of equilibrium swelling ratio, swelling kinetics and cytotoxicity. In particular, alginate hydrogels observed by a digital microscope have an open-pore channels structure with the sizes of hundreds micrometers. Also, the cell viability of all hydrogels were found to be much higher than that of poly(acrylic acid).

The discharge Characteristics and the Bubble Motion in Liquid $SF_6$ (액체 $SF_6$중 기포거동과 절연파괴특성에 관한 연구)

  • Choi, Eun-Hyuck;Park, Kwang-Seo;Choi, Sang-Tae;Kim, Lee-Kook;Yoon, Bung-Han;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.65-68
    • /
    • 2006
  • 현재 전력설비에 사용되고 있는 $SF_6$ 가스는 절연 및 소호성능이 우수하고 회복특성이 뛰어나기 때문에 각종 전력기기의 절연매체로서 널리 사용되고 있다. 하지만 산업사회의 발달로 인하여 도시의 공간 활용의 효율성 측면에서 전력기기들의 소형화, 지중화 및 고 신뢰화가 시도되고 있으며, 또한 온실가스에 대한 규제로서 '도쿄 의정서'가 정식 발효됨에 따라 환경문제로 인하여 전력설비의 $SF_6$ 가스의 유출 최소화, 대체 절연물질 개발 등의 친환경 재료의 개발이 새롭게 대두되고 있다. 따라서, 본 연구에서는 $SF_6$를 액화시켜 기존의 $SF_6$ 가스와 액체 $SF_6(LSF_6)$의 절연파괴특성을 측정/분석하여 $SF_6$의 대체물질로 $LSF_6$의 가능성을 검토하고, 혹한 지역에서 운용되고 있는 $SF_6$ 이용 전력설비의 온도저하에 따른 문제점을 구명하였다.

  • PDF