Transactions of the Korean Society of Mechanical Engineers A
/
v.27
no.1
/
pp.138-143
/
2003
Ultrasonic flowmeters have more advantages than the conventional method using pressure-difference. In these reasons, many advanced nations are already selling the commercial model. In RIST, we have been developed ultrasonic gas flow meter for the localization since a project was been contracted with POSCO in 1997. This paper describes a new ultrasonic gas flowmeter. This ultrasonic gas flowmeter is developed for accurate measurement of gases in a harsh environmental conditions. It is especially suited for measuring LDG. COG, BFG gases produced in iron & steel making process. In this study, we had developed the commercial model about the first tested model and applied a completed system to the POSCO gas line. Its performance has been proven by extensive field tests for several months in POSCO, iron & steel making company.
A separate triangular bar type differential pressure flow meter was developed for measuring exhaust gas flow rate from Diesel engine. Three kinds of the separate triangular bar flow meters whose aerodynamic angles are different one another are made and evaluated, respectively. The experimental results show that an aerodynamic shape has a effect on the pressure difference between upstream and downstream at the flow meter, that is, the thinner the shape of the separate triangular bar flow meter is, the smaller the pressure difference at the flow meter is. The separate triangular bar type flow meter was calibrated at both cold and high temperature of the gas flow. A burner system was designed for raising the gas temperature and it was well operated in controlling the gas temperature. An empirical correlation between mass flow rate and differential pressure at the separate triangular bar flow meter was obtained and the empirical correlation was also corrected by the gas temperature.
Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
/
2003.04a
/
pp.141-141
/
2003
신선농산물의 호홉속도를 측정하는 방법 중 하나인 개방계(open system) 호흡속도 측정시스템은 소정의 농도로 조정된 혼합기체를 측정대상시료에 흘려 보내며 측정하는 방법이다. 개방계 측정법의 장점은 혼합 기체조성 영역에서 정확한 호흡속도를 얻을 수 있으며 방치시간이 필요 없으므로 반복 측정이 용이한 것 등이다. 그러나 개방계 측정법은 공급되는 혼합기체의 농도와 유속이 일정하여야 하며 연속으로 호흡속도 측정용 챔버의 혼합기체 공급측과 배기측에서 기체시료를 수집하여 매우 미세한 기체농도의 차이를 측정할 수 있어야 하고 기체 시료 수집에 상당한 주의가 요구된다. 이러한 문제를 개선하기 위하여 개방계 호흡속도 측정 시스템을 자동화하였다. 자동화된 호흡속도 측정 시스템은 혼합기체 발생장치, 온도조절이 가능한 기체기밀용 챔버와 G.C로 구성되어 있다. 환경기체조성을 위한 혼합기체발생장치는 $N_2$, $O_2$, $CO_2$ 압축 실린더에서 공급되는 기체를 압력 조절기를 통해서 일차압력을 조정하고 정밀 압력 조절기를 이용하여 0.1~0.2 kg/$\textrm{cm}^2$의 정압을 유지시켰다. 압력이 일정해진 기체는 metering valve를 이용하여 각 기체의 유량을 소정의 비율로 제어할 수 있도록 하였으며 각각의 기체는 gas mixed cell에서 실험 농도의 환경기체조성으로 혼합되어 항온기내의 호흡속도 측정 챔버($25^{\circ}C$)로 공급될 수 있도록 하였다. 호흡속도 측정용 챔버는 개스킷이 장착된 아크릴 재질이며 온도 조절이 가능한 항온기로 구성되어 있다. 호흡속도 측정용 챔버와 G.C간의 기체흐름은 three way solenoid valve에 의하여 제어되며 전원의 on/off에 따라 공급측의 가스와 배기측의 가스가 선택적으로 G.C에 공급될 수 있도록 구성하였다. 측정 대상 챔버의 기체는 제어된 유로를 따라 multi-position valve를 통과하여 G.C에서 분석되도록 하였다. 본 연구에서 개발된 개방계 호흡속도 자동 측정 시스템의 성능 실험에서 혼합기체발생장치에서 조제된 혼합 기체의 농도를 설정치와 비교한 결과 $O_2$와 $CO_2$의 농도에서 평균오차 0.2%로 정밀한 것으로 나타났으며 호흡속도 측정용 챔버의 혼합기체 공급측과 배기측의 가스 농도를 3회 반복 측정한 결과 재현성에서는 0.1%이하의 편차로 나타났다. 개방계 호흡속도 자동 측정 시스템을 이용하여 환경기체조성하에서 토마토의 호흡속도를 측정하는 실측 실험을 수행한 결과 2$0^{\circ}C$에서 12.7~42.1mg$CO_2$/kg.hr였으며 12$^{\circ}C$에서 2.5~8.2mg$CO_2$/kg.hr로 일반적으로 보고되고 있는 토마토 호흡속도와 일치하는 결과를 나타내었다.
Kim, Jae-Hyung;Kim, Heuy-Dong;Lee, Ho-Joon;Hwang, Shang-Yoon
Proceedings of the KSME Conference
/
2003.11a
/
pp.998-1003
/
2003
Ultrasonic flow metering(UFM) technology is being received much attention from a variety of industrial fields to exactly measure the flow rate. The UFM has much advantage over other conventional flow meter systems, since it has no moving parts, and offers good accuracy and reliability without giving any disturbances to measure the flow rate, thereby not causing pressure losses in the flow fields. In the present study, 3-dimensional, unsteady, compressible Navier-Stokes equations are solved by a finite volume scheme, based upon the second order upwind scheme for spatial derivatives and the multi-stage Runge-Kutta integral method for time derivatives. In order to simulate multi-path ultrasonic flow meter, an excited pressure signal is applied to three different locations upstream, and the pressure signals are received at three different locations downstream. The mean flow velocities are calculated by the time difference between upstream and downstream propagating pressure signals. The obtained results show that the present CFD method simulates successfully ultrasonic meter gas flow and the mean velocity measured along the chord near the wall is considerably influenced by the boundary layers.
Sin, Jin-Hyeon;Gang, Sang-Baek;Go, Mun-Gyu;Im, Jong-Yeon;Jeong, Wan-Seop
Proceedings of the Korean Vacuum Society Conference
/
2010.08a
/
pp.45-45
/
2010
반도체 및 디스플레이 산업에 사용되는 진공펌프의 효율이 증대됨에 따른 성능 평가 기술의 향상 과 미세 유량을 조절 및 측정할 수 있는 시스템의 개발이 요구되고 있다. 유량 시스템 중 소닉노즐은 기체 유량 측정 표준기로 사용되고 있다. 또한 유량 측정에 있어서 사용상의 편리성, 이동성, 재현성 등 여러 가지의 장점을 가지고 있어 산업 현장에서 많이 사용되고 있다. 본 연구는 소닉노즐을 넓은 유량 범위에서 사용할 수 있도록 소닉노즐의 유출계수 교정을 목적으로 한다. ISO 9300에서 제시한 사양에 맞추어 목 직경 0.03 mm와 0.2 mm 그리고 1.6 mm의 소닉노즐을 제작하였다. 한국표준과학연구원에서 진공용 유량측정 장치로 개발된 정적형 유량계를 이용하여 제작된 3 종의 소닉노즐 유출계수를 확장불확도 3% 이내로 교정하였다. 교정된 소닉노즐의 유량 측정범위는 약 0.6~90, 000 cc/min 범위를 갖는 것으로 나타났으며, 사용유동 조건에 해당되는 레이놀드 수(Reynolds number) 범위는 26~75, 700 으로 확인되었다. 이러한 결과는 교정된 소닉노즐을 이용하여 진공공정에서 필요한 극 미세 유량의 정밀측정을 가능하게한 새로운 연구결과로 판단된다. 교정된 소닉노즐을 이용하여 진공펌프의 배기속도 측정결과는 기 구축된 정적법을 이용한 배기속도 측정결과와 3% 이내의 오차범위내로 매우 잘 일치함을 보였다. 교정된 소닉노즐은 향후 반도체 및 디스플레이 공정에 사용되는 다양한 진공펌프들의 배기속도를 현장에서 간단하게 평가할 수 있는 '현장 성능평가 장치'에 활용할 예정이며, 현재 공정현장에서 배기속도 측정에 널리 사용 중인 MFC를 대체할 수 있을 것으로 예상된다.
Journal of the Korean Society of Propulsion Engineers
/
v.20
no.3
/
pp.9-16
/
2016
An experimental study was performed to investigate the combustion characteristics of the liquid hydrocarbon fuel atomized by an ultrasonic oscillator. Configuration of the flame was caught by the high-speed camera, and images were analyzed in detail through a post-processing. In addition, the fuel consumption was measured using the balance during the combustion reaction. As a result, the consumption of atomized fuel increased with the increasing flow-rate of carrier-gas, but any correlation between the air/fuel ratio and carrier-gas flow-rate was not found. The variation of flame area was dependent on the fuel consumption and input power of the ultrasonic oscillator. FFT (Fast Fourier Transform) analyses using the flame area were conducted in order to discuss flame flickering.
Lee Jun Kyoung;Lee Sang Yong;Lee Han Ju;Oh Seung Hyub
Journal of the Korean Society of Propulsion Engineers
/
v.9
no.2
/
pp.32-39
/
2005
The effectiveness of the pogo suppression device (PSD) on the response of the piping system simulating the fuel (or oxidizer) supply lines of the rocket engines was investigated. The system response defined as the ratio of the flow rate to the pressure in the main tube was obtained for various PSD gas volumes $((0\~2)\times10^{-3}m^3)$ and three different baffle hole diameters (5, 50, 115mm). Existence of a gas volume in the PSD reduced the system resonance frequency. With a larger gas volume, the resonance frequency became lower, but only slightly, while the fluctuations of the main tube pressure and the flow rate damped down considerably. The resonance frequency decreased with the increase of the PSD inlet restriction (or the decrease of the baffle hole diameter), though slightly. However, with a larger inlet restriction, the PSD pressure wave showed a delayed response with the smaller amplitude compared to the pressure variation in the main tube.
Transactions of the Korean Society of Mechanical Engineers B
/
v.36
no.4
/
pp.449-455
/
2012
During the measurement of the flow rate of gases such as natural gas, flow hunting is observed in most orifice meters but the intensity of flow hunting at each metering system shows different characteristics. In order to investigate why such a difference occurs and whether the difference actually influences metering error, pipeline network analysis on the main factors and characteristics of flow hunting was carried out in a previous study. Following this, in this study, computational fluid dynamics (CFD) analysis was carried out to clarify the relation between flow instability and flow hunting and determine the factors influencing the orifice meter depending on the intensity of upward pressure fluctuation, time interval, and flow rate. Finally, we showed that the pressure hunting rate is a function of the ratio of the pressure difference before and after an orifice meter. On the basis of CFD analysis results, we also presented some major factors and relations influencing flow hunting.
Proceedings of the Korean Vacuum Society Conference
/
2012.08a
/
pp.102-102
/
2012
진공측정 특히 고진공영역에 사용되는 터보분자펌프, 이온펌프, 크라이오펌프 등의 특성평가 장치의 신뢰성을 확보하기 위해서는 신뢰성이 검증된 미세 유량발생 장치를 포함한 이온게이지를 이용한 고진공 측정기술이 확보되어야한다. 본 발표에서는 고진공펌프 특성평가를 위한 미세 기체유량계와 펌프 평가기술에 대한 국제적인 동등성을 확립하고 검증하기 위해 수행해오고 있는 진공분야의 국제비교 및 측정기술 개발 활동에 대해 소개한다.
Proceedings of the Korean Vacuum Society Conference
/
2011.08a
/
pp.95-95
/
2011
고진공영역에 사용되는 터보분자펌프, 이온펌프, 크라이오펌프 등의 특성평가 장치의 신뢰성을 확보하기 위해서는 신뢰성이 검증된 미세 유량발생 장치를 포함한 이온게이지를 이용한 고진공 측정기술이 확보되어야한다. 본 발표에서는 고진공펌프 특성평가를 위한 미세 기체유량계와 펌프 평가기술에 대한 국제적인 동등성을 확립하고 검증하기 위해 수행해오고 있는 진공 분야의 국제비교 및 ISO/TC 112 위원회 활동에 대해 소개한다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]