• Title/Summary/Keyword: 기준공기

Search Result 761, Processing Time 0.032 seconds

A Study on the Mixing of Dilution Air and Ammonia in the Ammonia Mixing Pipe of the Thermal Power Plant De-NOx Facility (화력발전소 탈질설비의 암모니아 혼합 관에서 희석 공기와 암모니아의 혼합에 관한 연구)

  • Kim, Ki-Ho;Ha, Ji-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.2
    • /
    • pp.49-55
    • /
    • 2022
  • According to reinforce environmental regulations, coal power plants have used selective catalytic reduction using ammonia as a reducing agent to reduce the amount of nitrogen oxide generation. The purpose of the present study was to derive a mixing device for effectively mixing dilute air and ammonia in the ammonia mixing pipe by performing computational fluid dynamic analysis. The mixing effect was compared by analysing the %RMS of ammonia concentration at the down stream cross section in the mixing pipe and the 16 outlets based on the case 1-1 shape, which is an existing mixing pipe without a mixing device. The mixing device was performed by changing the positions of a square plate on the downstream side of the ammonia supply pipe and an arc-shaped plate on the wall of the mixing pipe. In the case of the existing geometry(Case 1-1), the %RMS of ammonia concentration at the 16 outlets was 29.50%. The shape of the mixing device for Case 3-2 had a square plate on the downstream side of the ammonia supply pipe and an arc plate was installed adjacent to it. The %RMS of ammonia concentration for Case 3-2 was 2.08% at 16 outlets and it could be seen that the shape of Case 3-2 was the most effective mixing shape for ammonia mixing.

A case study for prediction of the natural ventilation force in a local long vehicle tunnel (장대도로터널의 자연환기력 예측 사례연구)

  • Lee, Chang-Woo;Kim, Sang-Hyun;Gil, Se-Won;Cho, Woo-Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.4
    • /
    • pp.395-401
    • /
    • 2009
  • One of the key design factors for the ventilation and safety system at extra long tunnel is the airflow velocity induced by the natural ventilation force. Despite of the importance, it has not been widely studied due to the complicated influencing variables and the relationship among them is difficult to quantify. At this moment none of the countries in the world defines its specific value on verified ground. It is also the case in Korea. The recent worldwide disasters by tunnel fires and demands for better air quality inside tunnel by users require the optimization of the tunnel ventilation system. This indicates why the natural ventilation force is necessary to be thoroughly studied. This paper aims at predicting the natural ventilation force at a 11 km-long tunnel which is in the stage of detailed design and will be the longest vehicle tunnel in Korea. The concept of barometric barrier which can provide the maximum possible natural ventilation force generated by the topographic effect on the external wind is applied to estimate the effect of wind pressure and the chimney effect caused by the in and outside temperature difference is also analyzed.

A Study on the Effective Controlling System of Radio-activity Ventilation (RI사용 의료기관의 효율적인 배기관리 방안)

  • Lee, Kyung-Jae;Lee, Jin-Hyung;Kim, Kyung-Hoon;Kwack, Dong-Woo;Jo, Hyun-Duck;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.91-98
    • /
    • 2008
  • Purpose: Radio-isotopes (RI) use has been steadily developing due to industrial and technical development in the modern medical society. Particularly, popularization of domestic cyclotrons dramatically enable hospitals to produce and use diagnostic radio-isotopes. Generally, only specific facilities such as hospitals, research institutes, nuclear power plants and universities can use radio-isotopes, they are also responsible for ventilation system. The strength of radioactivity in the air is strongly regulated and controlled by korea atomic energy law in Korea Institue of Nuclear Safety (KINS), so that air radioactivity exposure can lead to environmental pollution surrounding places. In this study, we'd like to find out the investigation and the present condition of the controlled ventilation system in domestic hospitals by an emission standard from KINS, and try to reach an agreement about how to use the ventilation system. Result: Definition of filters, features and structures of pre-filters, hepa-filters, charcol filters, filter exchange procedures and precautions are explained. RI deflation concentration and filter exchange cycle have been presented as a standard prescribed in the rules of KINS. The Radiation Control Management System (RCMS) introduced by Seoul National University Bundang Hospital linking to digital pressure gauge with computer controller in another medical facilities were described in details. Conclusions: The system of medical facilities using RI has been remarkably developing in 21 century. Especially, radiation safety control system has also been grown rapidly into the subdivision, specialization, advanced technology along with international technical improvement. However, As far as current RI ventilation system is concerned, it has nothing better than doing in the past. Preferentially, to reinforce this, more sophisticated system with strict periodic filter exchange and exhaust air control guidance should be introduced by applying brilliant domestic information technology for RCMS and digital gauge method. From personal point of view as a radiation safety manager, I have provide with present problems and improvements. Futhermore, more improved guidance should be conducted.

  • PDF

An Experimental Study on the Ultimate Strength and Deformation Capacity of Composite Beams with Eccentric Web Openings (편심유공합성보의 종국내력 및 변형능력에 관한 실험적 연구)

  • Choi, San Ho;Seo, Seong Yeon
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.5 s.48
    • /
    • pp.595-604
    • /
    • 2000
  • Web openings of large beams provide space for wiring, piping, and duct work to provide for proper drainage, pipes and duct must be slightly sloped with the attendant result that all web openings can not be centered on the centroidal axes of the beams. Test specimens are made for opening-depth to beam-depth ratio of 0.5 and for eccentricities of the opening center line of 10% from middepth of the beam because of the proximity of the opening edge to the flange. In this paper, available test results and theories relating to the strength of composite beams having eccentric rectangular openings are surveyed and experiments were carried out to examine the structural behaviors. In all the tests in this paper good agreement is demonstrated with maximum loads measured in tests, and observed failure modes Furthermore, compared with analytical values and experimental values of interaction diagram between moment and shear capacity were safed as it is scattered with outer part of the analytical values.

  • PDF

Comparative Evaluation of Impervious Ratio between KNU and HKU Campus Using Google Earth (Google Earth를 이용한 경북대와 홍콩대 캠퍼스의 불투수율 비교평가)

  • Um, Jung-Sup
    • Journal of the Korean association of regional geographers
    • /
    • v.15 no.3
    • /
    • pp.421-433
    • /
    • 2009
  • The impervious ratio was frequently employed as a fundamental attribute will be used as a proxy of the total environmental burden in the urban area since it may contribute as much or more on a cumulative basis to the overall environmental condition. This research proposes a comparative evaluation framework in a more objective and Quantitative way for an impervious ratio in the university campus, using the Google Earth. Two university campuses (Kyungpook National University: KNU, Hong Kong University: HKUJ were selected as survey objectives in order to evaluate the potential of Google Earth in monitoring impervious conditions in the campus. The 61cm resolution of Quickbird data combined with digital map realistically identified the major type of impervious surface such as road, building and parking lots in the study area by large scale spatial precision. The impervious zones with persistently high road density and parking space were specifically identified over the KNU campus while the HKC campus was intensively covered by tree, resulting in almost twice (31%). as compared to KNU (18.4%), The methods of characterizing impervious surface used in this study are easily replicable using data that are primarily publicly available, and therefore the collection of impervious coverage data via Google Earth is, therefore, proposed as a practical alternative.

  • PDF

Shark Antenna for Vehicle TDMB and GPS Receiver (TDMB 및 GPS 수신용 전장용 샤크 안테나)

  • Kim, Joo-Man;Son, Tae-Ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.6
    • /
    • pp.57-62
    • /
    • 2008
  • In this paper, a folded helical monopole antenna for TDMB receiving and a trapezoidal fractal microstrip patch antenna for GPS were designed and fabricated for the vehicle shark antenna. To minimize null which is generating toward antenna axis direction and to receive both vertical polarization and horizontal polarization for TDMB antenna, we fold 90 degree helical monopole element. GPS antenna to get wide bandwidth and gain improvement was designed an air substrate trapezoidal microstrip patch antenna. Fabricated TDMB and GPS antenna were measured for S11 and radiation pattern, and compared with a commercialized antenna. TDMB antenna shows 3 dB higher antenna gain and receiving signal strength than the commercial one. GPS antenna shows the gain of 4.31 dBi at the resonant frequency, which is $3{\sim}5\;dB$ higher gain over whole operating band and 135MHz wide bandwidth at 2:1 VSWR than the conventional ceramic antenna.

  • PDF

Start-up and operation of Gasoline Fuel Processor for Isolated Fuel Cell System (독립형 연료전지 시스템을 위한 가솔린 연료프로세스의 시동 및 운전)

  • Ji, Hyunjin;Bae, Joongmyeon
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.76-85
    • /
    • 2016
  • This study introduces the system layout and control strategy necessary to start and operate a fuel processor in a wide range of temperatures where a gasoline was selected as the fuel of fuel processor considering logistic support of Korea Army. The autothermal reformig(ATR) catalyst is heated to light-off temperature by combustion method in the initial stage. In order to ignite the gasoline and air mixture stably, the glow plug is installed after ATR catalyst. When the catalyst is increased to light-off temperature, the reformer is operated from initiation to steady state conditions as follows: Partial oxidation(POX) mode, partial ATR mode, full ATR mode. Finally the start-up and control strategy is validated by the operational test of gasoline fuel processor at low and room temperature. As a result the gasoline fuel processor is able to start-up within 40 min and to produce the reformate gas which has 37 ~ 42 vol.%(dry basis) of $H_2$ and 0.3 vol.% of CO.

Thickening of Activated Sludge Using Low Pressure Flotation Pilot System (파일롯 규모의 저압형 부상장치를 이용한 하수슬러지 농축에 관한 연구)

  • Kim, Ji Tae;Oh, Joon Taek;Kim, Jong Kuk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.3
    • /
    • pp.172-177
    • /
    • 2014
  • Low pressure air flotation (LAF) pilot plant for sludge thickening was installed in Chung Nam N.S. municipal waste water treatment plant to verify its application possibility. Effects of operating conditions such as coagulant dosages and microbubble water ratio on thickening of the mixed sludge were examined. Microbubbles which were generated in the chamber of $1.5kgf/cm^2$ by high speed collision method with foaming agent were used to float sludge. Solid loading of $30kg/m^2/hr$, solid contents in thickened sludge of 60,300 mg/L and SS removal efficiency of 99% were obtained through long period operating LAF in conditions of mixed sludge concentration of 14,400 mg/L, coagulant dosage of 27.6 mg/L, foaming agent addition of 4.0 mg/L and microbubble water injection ratio of 9.7%.

A Study on Signature-based Wireless Intrusion Detection Systems (시그니처 기반의 무선 침입 탐지 시스템에 관한 연구)

  • Park, Sang-No;Kim, A-Yong;Jung, Hoe-Kyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.5
    • /
    • pp.1122-1127
    • /
    • 2014
  • WLAN is affordability, flexibility, and ease of installation, use the smart device due to the dissemination and the AP (Access Point) to the simplification of the Office building, store, at school. Wi-Fi radio waves because it uses the medium of air transport to reach areas where security threats are always exposed to illegal AP installation, policy violations AP, packet monitoring, AP illegal access, external and service access, wireless network sharing, MAC address, such as a new security threat to steal. In this paper, signature-based of wireless intrusion detection system for Snort to suggest how to develop. The public can use hacking tools and conduct a mock hacking, Snort detects an attack of hacking tools to verify from experimental verification of the suitability of the thesis throughout.

Reaction Characteristics of Desulfurization Sorbents for Warm Syngas Cleanup (석탄 합성가스 정제용 탈황제의 흡수/재생 온도 변화에 따른 황흡수 특성)

  • Baek, Jeom-In;Ryu, Jungho;Lee, Joong Beom;Eom, Tae-Hyoung;Lee, Kisun;Wi, Yong-Ho;Ryu, Chong Kul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.107.1-107.1
    • /
    • 2010
  • 고체 흡수제를 이용한 석탄합성가스 중의 황제거 기술은 습식 스크러빙 방식에 비해 고온에서 운전가능하므로 석탄가스화복합발전의 효율 향상을 가져올 수 있다. 고체탈황제는 서로 연결된 두 개의 유동층 반응기를 순환하면서 흡수탑에서는 합성가스 중의 $H_2S$로부터 황을 흡수하고 재생탑에서는 공기 중의 산소와 흡수된 황이 반응하여 $SO_2$를 배출하고 재생된다. 따라서 고체 황 흡수제는 유동층 공정에 응용가능한 물성과 함께 높은 황흡수능과 빠른 반응성이 요구된다. 본 연구에서는 기존 개발된 고체 탈황제가 가졌던 소성시 수축 현상, 낮은 내마모도 등을 개선하기 위해 지지체 조성을 변경하여 개발한 분무성형 탈황제의 흡수 재생 온도에 따른 황흡수 특성 변화를 조사하였다. $H_2S$ 1 vol. %를 함유한 모사 합성가스를 이용하여 흡수온도 450, $500^{\circ}C$, 재생온도 500, 550, 600, $650^{\circ}C$에서 황 흡수능을 열중량분석기를 이용하여 측정하였다. 개발된 흡수제는 유동층 공정 적용에 적합한 훌륭한 물성(형상, 밀도, 강도 등)과 함께 $500^{\circ}C$ 흡수와 $650^{\circ}C$ 재생을 기준으로 10 wt% 이상의 높은 황흡수능을 보여주었다. 흡수온도 변화는 황 흡수능 변화에 큰 영향을 미치지 않았으나, 재생온도가 $600^{\circ}C$ 이하인 경우 황흡수능이 5 wt% 이하로 크게 떨어져 재생온도를 $650^{\circ}C$ 이상 유지시키는 것이 중요함을 알 수 있었다.

  • PDF