• Title/Summary/Keyword: 기밀도 실측

Search Result 10, Processing Time 0.018 seconds

The measurement study on the airtightness of dwellings based on the passive design (패시브 디자인을 적용한 주택의 기밀성에 관한 실측 사례 연구)

  • Lee, Tae-Goo;Yun, Doo-Young
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.13-20
    • /
    • 2013
  • Today, the world energy consumption in buildings occupies more than 30%. In our country, the energy consumption in buildings also occupies 25% of the entire national energy consumption. With the increasing demand of energy saving in architectural fields, there is a more interest in low-energy construction. For these low-energy housings, our country is planning to apply the energy-saving design standards at the level of passive houses in 2017. However, there is still a limitation in energy saving only with the standards on the performance of envelope in buildings. This means that unless a building is airtight even though it was well-insulated, cooling and heating energy consumption will increase due to the infiltration and leakage. Therefore, this study aims to make a comparative analysis of airtight performance by conducting a blower door test on the housings applied with passive designs, analyze the reasons why most houses fall short of the airtightness standards, and complement the airtightness problems in the inadequate parts of the buildings in order to save building energy.

A Study of Measurement on Airtightness and Air-Flow Performance of Apartment Housing Adopting Window Frame-Type Natural Ventilation (자연환기장치가 적용된 공동주택의 기밀 및 공기유동 성능 실측 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Kim, Sun-Dong
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.325-332
    • /
    • 2014
  • The purpose of this study was to measure the airtightness and Air-Flow Performance for 7th house of small apartment houses adopted window frame-type natural ventilation. All window and living room door is provide with window frame-type natural ventilation, and there is provide with manual controller. As the object of measurement, the 6th type small apartment houses with area of $33m^2$ to $51m^2$ was selected. airtightness performance was measured at the front door using Blower door system. We measured ventilation rate per hour on 50Pa pressure different between inside and outside by the 1st to 6th cases. As a result, when the natural ventilation frame was closed, average amounts are shown as the ventilation rate per hour were 2.27ACH (CASE1). and the result is similar to general apartment house (1.65~4.28ACH). When the natural ventilation frame was open, average amounts are shown as the ventilation rate per hour were 5.87ACH (CASE6). In addition, that's a 3.6ACH increased more than CASE1.

Field Measurement of Infiltration in New Apartments using De-pressurization Method (신축 공동주택에서 감압법을 이용한 기밀성능 실측 연구)

  • Yoon, Jae Ock
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.27-32
    • /
    • 2013
  • Infiltration is air flow that occurs through cracks in buildings. According to level and kind of infiltration, the cooling load and heating load in buildings may increase. In this study I conducted field measurements to evaluate air tightness in 27 new apartment units. Field measurements for new apartments was the focus. For the de-pressurization method, the equipment utilized to gauge airtightness included KNS-5000C and KNS-4000 which were installed on the window in order to measure indoor air leakage. The results are summarized as follows. The average ACH50 of a $59m^2$ APT was 3.98, 3.82 for a $84m^2$ APT, and 2.73 for a $114m^2$ APT. The total average ACH50 of 27units was 3.51.

A Study on the Measurement of Airtightness Performance of Detached Houses in Chung-cheong area (충청지역 단독주택의 기밀성능 실측 연구)

  • Yoon, Jong-Ho;Park, Jae-Wan;Lee, Kwang-Sung;Baek, Nam-Choon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.65-71
    • /
    • 2008
  • The purpose of this study is to investigate an airtightness of typical Korean detached houses with field measurements. Air leakage testings by means of blower door test in accordance with ASTM E79-8 were measured in 22 detached dwellings in Daejeon and Geumsan. The results showed that detached dwellings have an average airtightness with ACH50/20 (air chang per hour at a pressure difference of 50 Pa between inside outside) of 0.82 $hr^{-1}$ which is a higher range than for typical apartments and leakage class G by normalized leakage area of ASHRAE.

Field Measurements of Indoor Air Quality in Apartment Units at Medium-size Cities (중소도시 공동주택의 실내공기질(새집증후군) 실측에 관한 연구)

  • Yoon, JaeOck
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.81-86
    • /
    • 2010
  • The main sources of the new house syndrome(sometimes it called sick building syndrome) are a concentration of formaldehyde (HCHO) and a concentration of total volatile organic compounds(TVOC). I had field measurements of indoor air quality in the apartment unit at medium-size cities(Y city, C city). I measured indoor air temperature, HCHO concentration in 16 units, TVOC concentration in 6 units and air tightness in 7 units. And I measured outdoor air quality, HCHO concentration and TVOC concentration. Mean concentration of HCHO was $357{\mu}g/m^3$(2006 standard=$120{\mu}g/m^3$), mean concentration of TVOC was $3,092{\mu}g/m^3$ and mean effective air leakage area was 193 cm2. There was a close relation between the indoor air temperature and HCHO concentration, between the indoor air temperature and TVOC concentration. Air tightness also had relation.

The Measurement of Airtightness Performance of Multi-Family Housing (다가구 및 다세대 원룸주택의 기밀성능 실측연구)

  • Baek, Nam-Choon;Han, Seung-Hyeon;Lee, Wang-Je;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.14 no.5
    • /
    • pp.117-121
    • /
    • 2014
  • Even though a study of airtightness performance of apartment and detached house have been done constantly, there are few of studies of multi-family housing which increasing every year. Therefore, this study analyzed airtightness performance of 20 households of one room in Daejeon to investigate airtightness performance standard. All experiments were performed under the same conditions except sealing windows to investigate airtightness performance without sealing windows (natural condition) and airtightness performance with sealing windows of studio apartment. As results, (1) average ACH50 without sealing windows was 19.2/h for pressurization, and 12.8/h for depressurization and (2) average ACH50 with sealing windows was 16.0/h for pressurization, and 10.7/h for depressurization and ACH50 in both condition, ACH50 under pressurization was about 50% higher than that under depressurization. Throughout this experiment, we can figure out that about 16% of air infiltration rate is occurred in windows, and the other 84% is occurred in rest of places such as Junction structure, socket and ventilating opening.

A Study on the Noise Characteristics of Subway Train (도시철도 전동차 소음 특성에 관한 연구)

  • Choi, Yong-Woon;Koo, Jeong-Seo;You, Won-Hee;Koh, Hyo-In
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.3
    • /
    • pp.329-334
    • /
    • 2009
  • Subway is used as a useful transportation method to solve the metropolitan traffic problem for its advantages of being not only accurate, safe and massive, but also of not producing any exhaustion gas in compare with the other ground transportation systems. However, noise inside the car due to concrete based rail track and tunnel structure has become a social problem. So, an analysis on the noise characteristics according to their routes and locations was made on the basis of the actually measured results from the trial run. To reduce the interior noise of subway train, the side part of rolling stock should have a noise blocking system fur low band frequency noise, the floor of it should have that for medium range frequency noise and the side part as well as lower part of it should have good noise reduction and absorption function.

Estimation of Water Leak Rate in the Underground Oil Storage Cavern (지하 원유 저장공동에서의 누수량 산정에 대한 연구)

  • Shim, Hyun-Jin;Park, Tae-Jun;Jeong, Woo-Cheol;Kim, Ho-Yeong;Choi, Young-Tae
    • Tunnel and Underground Space
    • /
    • v.20 no.4
    • /
    • pp.233-240
    • /
    • 2010
  • Double Plug is constructed for preventing mixing of two different oils between two compartments in the underground oil storage cavern. And the gas and oil tightness of double plug is tested from the measurement of water leakage from double plug after the completion of double plug water filling. If water leakage is underestimated, it can increase construction cost and if water leakage is overestimated, it can increase operating cost. Therefore, optimum water leakage should be estimated to cut down the cost. In this study, hydraulic stability analysis was conducted to consider permeable properties of rock mass around double plugs and a water leak rate from double plug was estimated from the hydraulic stability analysis and case study. Finally, the reliability of estimation of water leak rate was proven by comparing estimated water leak rate with measured data.

The Field Measurement of Airtightness in the Apartment Buildings (신축공동주택의 기밀성능 실측에 관한 연구)

  • Park, Won seok;Yoon, Jae Ock
    • KIEAE Journal
    • /
    • v.3 no.3
    • /
    • pp.43-50
    • /
    • 2003
  • Nowdays the apartment is a main type of modernized residential buildings. According to the improvement of construction techniques and functions of windows and doors, recent apartments are enhanced air tightness of windows, doors and building envelopes. As Infiltration is decreased and natural ventilation is reduced, energy could be saved in winter. However, indoor air quality is bad. The air Infiltration of a building could be enlarged by physical actions, such as building designs, constructions and reduction of air tightness which is caused by aging. This research analyzes and measures with KNS-4000P (Sapporo air tightness measurement) the air tightness of the high rise apartments which is recently constructed and not occupied yet. With depressurization method, the KNS-4000 installed on the window and the indoor air-leakage was measured. At that time, Air come out from the edge of the windows and doors because of the pressure differences between indoor and outdoor. We measure the amount of the air as effective air leakage areas. This method of depressurization takes less time to measure than other methods and is less affected from other conditions. We measured infiltration of total 56 household, 29 households S apartment (total floor area : $64.42m^2$) in Balan and 29 households D apartment(total floor area : $78.21m^2$) in Chonan. As a result of the field measurements at October 2003, normalized leakage area of D apartment in Cheonan was $2.05cm^2/m^2{\sim}3.49cm^2/m^2$ (average: $2.77cm^2/m^2$) and normalized leakage area of S apartment in Balan is $1.23cm^2/m^2{\sim}1.68cm^2/m^2$ (average: $1.5cm^2/m^2$).

개방계 측정시스템을 이용한 토마토 호흡속도의 자동측정

  • Lee, Hyun-Dong;Yoon, Hong-Sun;Lee, Won-Ok;Jung, Hoon;Cho, Kwang-Hwan
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.04a
    • /
    • pp.141-141
    • /
    • 2003
  • 신선농산물의 호홉속도를 측정하는 방법 중 하나인 개방계(open system) 호흡속도 측정시스템은 소정의 농도로 조정된 혼합기체를 측정대상시료에 흘려 보내며 측정하는 방법이다. 개방계 측정법의 장점은 혼합 기체조성 영역에서 정확한 호흡속도를 얻을 수 있으며 방치시간이 필요 없으므로 반복 측정이 용이한 것 등이다. 그러나 개방계 측정법은 공급되는 혼합기체의 농도와 유속이 일정하여야 하며 연속으로 호흡속도 측정용 챔버의 혼합기체 공급측과 배기측에서 기체시료를 수집하여 매우 미세한 기체농도의 차이를 측정할 수 있어야 하고 기체 시료 수집에 상당한 주의가 요구된다. 이러한 문제를 개선하기 위하여 개방계 호흡속도 측정 시스템을 자동화하였다. 자동화된 호흡속도 측정 시스템은 혼합기체 발생장치, 온도조절이 가능한 기체기밀용 챔버와 G.C로 구성되어 있다. 환경기체조성을 위한 혼합기체발생장치는 $N_2$, $O_2$, $CO_2$ 압축 실린더에서 공급되는 기체를 압력 조절기를 통해서 일차압력을 조정하고 정밀 압력 조절기를 이용하여 0.1~0.2 kg/$\textrm{cm}^2$의 정압을 유지시켰다. 압력이 일정해진 기체는 metering valve를 이용하여 각 기체의 유량을 소정의 비율로 제어할 수 있도록 하였으며 각각의 기체는 gas mixed cell에서 실험 농도의 환경기체조성으로 혼합되어 항온기내의 호흡속도 측정 챔버($25^{\circ}C$)로 공급될 수 있도록 하였다. 호흡속도 측정용 챔버는 개스킷이 장착된 아크릴 재질이며 온도 조절이 가능한 항온기로 구성되어 있다. 호흡속도 측정용 챔버와 G.C간의 기체흐름은 three way solenoid valve에 의하여 제어되며 전원의 on/off에 따라 공급측의 가스와 배기측의 가스가 선택적으로 G.C에 공급될 수 있도록 구성하였다. 측정 대상 챔버의 기체는 제어된 유로를 따라 multi-position valve를 통과하여 G.C에서 분석되도록 하였다. 본 연구에서 개발된 개방계 호흡속도 자동 측정 시스템의 성능 실험에서 혼합기체발생장치에서 조제된 혼합 기체의 농도를 설정치와 비교한 결과 $O_2$$CO_2$의 농도에서 평균오차 0.2%로 정밀한 것으로 나타났으며 호흡속도 측정용 챔버의 혼합기체 공급측과 배기측의 가스 농도를 3회 반복 측정한 결과 재현성에서는 0.1%이하의 편차로 나타났다. 개방계 호흡속도 자동 측정 시스템을 이용하여 환경기체조성하에서 토마토의 호흡속도를 측정하는 실측 실험을 수행한 결과 2$0^{\circ}C$에서 12.7~42.1mg$CO_2$/kg.hr였으며 12$^{\circ}C$에서 2.5~8.2mg$CO_2$/kg.hr로 일반적으로 보고되고 있는 토마토 호흡속도와 일치하는 결과를 나타내었다.

  • PDF