• Title/Summary/Keyword: 기만 효과

Search Result 11,180, Processing Time 0.049 seconds

The efficacy of continuous positive airway pressure (CPAP) for patient with left breast cancer (좌측 유방암 방사선치료에서 CPAP(Continuous Positive Airway Pressure)의 유용성 평가)

  • Jung, Il Hun;Ha, Jin Sook;Chang, Won Suk;Jeon, Mi Jin;Kim, Sei Joon;Jung, Jin Wook;Park, Byul Nim;Shin, Dong Bong;Lee, Ik Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • Purpose: This study examined changes in the position of the heat and lungs depending on the patient's breathing method during left breast cancer radiotherapy and used treatment plans to compare the resulting radiation dose. Materials and methods: The participants consisted of 10 patients with left breast cancer. A CT simulator(SIMENS SOMATOM AS, Germany) was used to obtain images when using three different breathing methods: free breathing(FB), deep inspiration breath hold(DIBH with Abches, DIBH), inspiration breath hold(IBH with CPAP, CPAP). A Ray Station(5.0.2.35, Sweden) was used for treatment planning, the treatment method was volumetric modulated arc therapy (VMAT) with one partial arc of the same angle, and the prescribed dose to the planning target volume (PTV) was a total dose of 50Gy(2Gy/day). In treatment plan analysis, the 95% dose (D95) to the PTV, the conformity index(CI), and the homogeneity index (HI) were compared. The lungs, heart, and left anterior descending artery (LAD) were selected as the organs at risk(OARs). Results: The mean volume of the ipsilateral lung for FB, DIBH, and CPAP was 1245.58±301.31㎤, 1790.09±362.43 ㎤, 1775.44±476.71 ㎤. The mean D95 for the PTV was 46.67±1.89Gy, 46.85±1.72Gy, 46.97±23.4Gy, and the mean CI and HI were 0.95±0.02, 0.96±0.02, 0.95±0.02 and 0.91±0.01, 0.90±0.01, 0.92±0.02. The V20 of Whole Lung was 10.74±4.50%, 8.29±3.14%, 9.12±3.29% and The V20 of the ipsilateral lung was 20.45±8.65%, 17.18±7.04%, 18.85±7.85%, the Dmean of the heart was 7.82±1.27Gy, 6.10±1.27Gy, 5.67±1.56Gy, and the Dmax of the LAD was 20.41±7.56Gy, 14.88±3.57Gy, 14.96±2.81Gy. The distance from the thoracic wall to the LAD was measured to be 11.33±4.70mm, 22.40±6.01mm, 20.14±6.23mm. Conclusion: During left breast cancer radiotherapy, the lung volume was 46.24% larger for DIBH than for FB, and 43.11% larger for CPAP than FB. The larger lung volume increases the distance between the thoracic wall and the heart. In this way, the LAD, which is one of the nearby OARs, can be more effectively protected while still satisfying the treatment plan. The lung volume was largest for DIBH, and the distance between the LAD and thoracic wall was also the greatest. However, when performing treatment with DIBH, the intra-fraction error cannot be ignored. Moreover, communication between the patient and the radiotherapist is also an important factor in DIBH treatment. When communication is problematic, or if the patient has difficulty holding their breath, we believe that CPAP could be used as an alternative to DIBH. In order to verify the clinical efficacy of CPAP, it will be necessary to perform long-term follow-up of a greater number of patients.

Results of Radiation Therapy and Extrafascial Hysterectomy in Bulky Stage IB, IIA-B Carcinoma of the Uterine Cervix (종괴가 큰 병기 IB, IIA-B 자궁경부암에서 방사선치료와 Extrafascial Hysterectomy의 결과)

  • Kim Jin Hee;Lee Ho Jun;Choi Tae Jin;Do Cha Soon;Lee Tae Sung;Kim Ok Bae
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.23-29
    • /
    • 1999
  • Purpose : To evaluate the efficacy of radiation therapy and extrafascial hysterectomy in bulky stage IB, IIA-B uterine cervix cancers. Methods and Materials : Twenty four patients with bulky stage IB and IIA-B carcinoma of the uterine cervix were treated with extrafascial hysterectomy following radiation therapy due to doubts of residual disease at Department of therapeutic radiology, Keimyung University, Dongsan Hospital, from April 1986 to December 1997 According to FIGO staging system, there were 7 patients with stage IB, 9 patients with IIA and 8 patients with IIB stage whose median age was 45. Pathologic distribution showed 16 patients with squamous cell carcinoma and 8 patients with adenocarcinoma. Seven patients had tumors that are less than 5cm in size and 17 patients had tumors with larger than 5cm. The mean interval between radiation therapy and extrafascial hysterectomy was 57 days. The radiation therapy consisted of external irradition to the whole pelvis (180 cGy/fraction, mean 4100 cGy) and parametrial boost (for a mean total dose of 5000 cGy) with midline shield (4H 10 cm), followed by intracavitary irradiation up to 7500 cGy to point A (maximum 8500 cGy). The maximum follow up duration was 107 months and mean follow up duration was 42 months. Results :Ten out of 24 patients (41.7%) had residual disease found at the time of extrafascial hysterectomies. Five year overall survival rate (5Y OSR) and five year disease free survival rate (5Y DFSR) were 63.6% and 62.5% respectively. Five year overall survival rate for stage IB and IIA was 71.4% and 50% for stage IIB. There was a significant difference in 5Y OSR and 5Y DFSR between patients with and those without residual disease (negative vs positive, 83.3% vs. 40% (P=0.01), 83.3% vs 36% (P=0.01) respectively). There was a notable tendency of better survival with adenocarcinoma than with squamous cell carcinoma (adenocarcinoma vs squamous cell carcinoma, 85.7% vs. 53.3% (P=0.1), 85.7% vs. 50.9% (P=0.1) of 5Y OSR and 5Y DFS respectivey). Total dose to A point did not make a significant difference in survival rate or the existence of residual lesion (< 7500 cGy, ${\geq}$ 7500 cOy). It was also noted that significantly more frequent local failures have occurred in patients with positive residual disease compared with negative residual disease (5/10 vs. 0/14, p=0.003), There was no death related to the treatment. Conclusion : There was no improvement of residual disease and to the overall survival rate in spite of increased total dose to point A. We conclude that there is a possible beneficial effect of radiation therapy followed by extrafaseial hysterectomy in survival for adenocarcinoma of bulky stage IB and IIA-B uterine cervix. We need to confirm this with longer follow up and with large number of patients.

  • PDF

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

The Study on Usefulness of LEAP Collimator in Lung Ventilation SPECT (Lung Ventilation SPECT에서 LEAP Collimator의 유용성에 관한 연구)

  • Kim, Jung Soo;Kim, Soo Mee;Kim, Jin Eui;Lee, Jae Sung;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.18-24
    • /
    • 2012
  • Purpose : Although lung ventilation SPECT (LV-SPECT) has a good sensitivity in detection of deep lung lesions, it is difficult to apply the LV-SPECT to patients having breathing problems due to limited examination time. In this study, we evaluated the usefulness of LEAP collimator, which provides high detection sensitivity and tolerable resolution, for the LV-SPECT in terms of diagnostic accuracy and examination time. Materials and Methods : Four volunteers inhaled Technegas (370 MBq) and the lung ventilation planar scan (LVPS, 300 counts/view (cpv)) with LEHR collimator was performed using Siemens E.cam scanner as a reference test. LV-SPECT scans were performed with three collimators, LEHR, LEUHR, and LEAP, in low (7 kcpv) and high (70 kcpv) counting modes. The count ratios of left (LT) and right (RT) lung segments were calculated on the geometric mean view of anterior and posterior images for LVPS and on the summed coronal images of LV-SPECT, respectively. Comparing to LVPS, the usefulness of three different collimators for LV-SPECT was evaluated through statistical analysis (paired t-test), on count ratios of lung segments. Results : The average LT:RT ratio in LVPS was 47:53. For LV-SPECT, there were negligible difference of the LT:RT ratios (48:52 on average) among three different collimators in low and high counting modes. Comparing to standard LVPS with LEHR, all LV-SPECTs with different collimators resulted in similar diagnostic accuracy through paired t-test (p>0.05). The scan time in LVPS (6 views) was 17.3 min. For LV-SPECT (128 views) in low counting mode, it took 18.7 (LEUHR), 15.0 (LEHR), and 12.3 min (LEAP), respectively. Conclusion : Comparing to standard LVPS, the LV-SPECT with LEAP in low counting mode provided the comparable diagnostic accuracy in addition to shortened scan time.

  • PDF

Utility of Wide Beam Reconstruction in Whole Body Bone Scan (전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성)

  • Kim, Jung-Yul;Kang, Chung-Koo;Park, Min-Soo;Park, Hoon-Hee;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The Wide Beam Reconstruction (WBR) algorithms that UltraSPECT, Ltd. (U.S) has provides solutions which improved image resolution by eliminating the effect of the line spread function by collimator and suppression of the noise. It controls the resolution and noise level automatically and yields unsurpassed image quality. The aim of this study is WBR of whole body bone scan in usefulness of clinical application. Materials and Methods: The standard line source and single photon emission computed tomography (SPECT) reconstructed spatial resolution measurements were performed on an INFINA (GE, Milwaukee, WI) gamma camera, equipped with low energy high resolution (LEHR) collimators. The total counts of line source measurements with 200 kcps and 300 kcps. The SPECT phantoms analyzed spatial resolution by the changing matrix size. Also a clinical evaluation study was performed with forty three patients, referred for bone scans. First group altered scan speed with 20 and 30 cm/min and dosage of 740 MBq (20 mCi) of $^{99m}Tc$-HDP administered but second group altered dosage of $^{99m}Tc$-HDP with 740 and 1,110 MBq (20 mCi and 30 mCi) in same scan speed. The acquired data was reconstructed using the typical clinical protocol in use and the WBR protocol. The patient's information was removed and a blind reading was done on each reconstruction method. For each reading, a questionnaire was completed in which the reader was asked to evaluate, on a scale of 1-5 point. Results: The result of planar WBR data improved resolution more than 10%. The Full-Width at Half-Maximum (FWHM) of WBR data improved about 16% (Standard: 8.45, WBR: 7.09). SPECT WBR data improved resolution more than about 50% and evaluate FWHM of WBR data (Standard: 3.52, WBR: 1.65). A clinical evaluation study, there was no statistically significant difference between the two method, which includes improvement of the bone to soft tissue ratio and the image resolution (first group p=0.07, second group p=0.458). Conclusion: The WBR method allows to shorten the acquisition time of bone scans while simultaneously providing improved image quality and to reduce the dosage of radiopharmaceuticals reducing radiation dose. Therefore, the WBR method can be applied to a wide range of clinical applications to provide clinical values as well as image quality.

  • PDF

Effects of Market Orientation and Relationship Orientation with Suppliers on Business Performance in Animal Clinic Industry: Moderating Effects of Entrepreneur's Characteristics and Clinic Location (동물병원의 시장지향성과 공급업체와의 관계지향성이 동물병원 성과에 미치는 영향: 경영자의 특성과 동물병원 입지에 따른 조절효과)

  • Yoo, Dong-Keun;Suh, Seung-Won;Lee, Yong-Ki
    • Journal of Global Scholars of Marketing Science
    • /
    • v.18 no.2
    • /
    • pp.189-222
    • /
    • 2008
  • This study developed a model to empirically investigate the effects of market orientation and relationship orientation with suppliers on business performance and examine the moderating effects of entrepreneur's characteristics (working tenure) and clinic's location. The data was collected from 200 animal clinics which belong to Korean Animal Hospital Association (KAHA)'s national conference in April, 2007. Descriptive statistic, factor analysis, reliability analysis, and regression analysis were conducted to analyze the data using SPSS/PC+ 12.0. The findings are as follows. First, the market orientation of animal clinics influences significantly both financial and non-financial performance. When the moderating effect of entrepreneur's working tenure is considered, market orientation has significant effect on animal clinic's financial and non-financial performance. However, when the moderating effect of animal clinic's location is considered, market orientation has not significant effect on animal clinic's financial and non-financial performance. Second, animal clinic's relationship orientation with suppliers mostly affects the financial and non-financial performance significantly. When entrepreneur's working tenure in the clinic is longer (above 4 years group), relationship orientation with suppliers significantly affects both financial and non-financial performance. Meanwhile, when the entrepreneur's working tenure in the clinic is shorter (less than 3 years group), relationship orientation with suppliers doesn't affect clinic's financial performance but affect non-financial performance partially. In other words, when entrepreneur's working tenure is shorter (less than 3 years group), market orientation more influences on clinic's financial and non-financial performance while relationship orientation with suppliers does less. It is thought that their relation with suppliers and relationship orientation activities with suppliers are less strongly established and maintained yet. So, they primarily focus on market orientation strategy when entrepreneur's working tenure is shorter. Third, when animal clinics are located in non-metropolitan area, relationship orientation with suppliers significantly affects financial and non-financial performance. However, when animal clinics are located in metropolitan area, it doesn't affect financial and non-financial performance either. It is thought that animal clinics which are located in non-metropolitan area need stronger relationship with suppliers and need support more from them as most of suppliers actively work in metropolitan area not in the non-metropolitan area and animal clinics in metropolitan area can easily get better market information than animal clinics in non-metropolitan area. Lastly, while the effect of the market orientation significantly influences animal clinic's business performance continuously, the effect of the relationship orientation differently influences business performance as it is moderated by entrepreneur's working tenure and animal clinic's location. So, relationship orientation with suppliers can be selectively applied to improve the clinic's financial and no-financial performance. In summary, both of animal clinic's marketing orientation and animal clinic's relationship orientation with suppliers positively influence their business performance. However, entrepreneur's working tenure and animal clinic location moderate the relationship between market orientation and relationship orientation and their business performance differently. This study is quite meaningful to empirically investigate the effects of both of market orientation and relationship orientation with suppliers on business performance and examine the moderating effects of entrepreneur's characteristics (working tenure) and clinic's location. And, as this kind of study has been very few in the context of animal clinic industry, it helps practically understand the effects of market orientation and relationship orientation with suppliers on the financial and non-financial performance in animal clinic industry. Furthermore, as the market conditions in animal clinic industry have been in difficulty for a few years, this study can help improve animal clinic's financial and non-financial business performance together with their suppliers as business partners. Lastly, this study can help find mid-term and long-term cooperation between animal clinics and their suppliers. This study has some limitations. So, care should be taken when generalizing the results of the study. First, our samples were collected from only the animal clinics industry. However, a comparison of the results presented here with those form other marketing contexts (e.g., general hospitals) would be worthwhile. Future comparative research will enhance the generality of our contingency theory cross industry context. Second, this study found that market orientation and relationship orientation affect business performance. However, there may be other antecedents, such as internal market orientation and relationship orientation with customers. Also, this research did not consider other moderators, such as overall market conditions, competitive situations, and power/conflict between suppliers and buyers in the relationship between market and relationship orientation and business performance.

  • PDF

Removal Characteristics of Residual Hydrogen Peroxide (H2O2) according to Application of Peroxone Process in O3/BAC Process (O3/BAC 공정에서 Peroxone 공정 적용에 따른 잔류 과산화수소 제거 특성)

  • Yeom, Hoon-Sik;Son, Hee-Jong;Seo, Chang-Dong;Kim, Sang-Goo;Ryu, Dong-Choon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.889-896
    • /
    • 2013
  • Advanced Oxidation Processes (AOP) have been interested for removing micropollutants in water. Most of water treatment plants (WTPs) located along the lower part of Nakdong River have adopted the $O_3/BAC$ process and have interesting in peroxone process a kind of AOP. This study evaluated the removal characteristics of residual hydrogen peroxide ($H_2O_2$) combining with the biofiltration process in the next BAC process when the hydrogen peroxide is applied for the WTP operating $O_3/BAC$ process. In the experiment, changing the temperature and the concentration of $H_2O_2$ of influent, the biofiltration process showed rapidly dropped the biodegradability when the $H_2O_2$ concentration was increased and lowered water temperature while BAC process maintained relatively stable efficiency. The influent fixed at $20^{\circ}C$ and the concentration of $H_2O_2$ at 300 mg/L was continuously input for 78 hours. Most of the $H_2O_2$ in the influent did not remove at the biofiltration process controlled 5 to 15 minutes EBCT condition after 24~71 hours operating time while BAC process controlled 5 to 15 minutes EBCT showed 38~91% removal efficiency condition after 78 hours operating time. Besides, after 78 hours continuously input experiment, the biomass and activity of attached bacterial on the biofilter and BAC were $6.0{\times}10^4CFU/g$, $0.54mg{\cdot}C/m^3{\cdot}hr$ and $0.4{\times}10^8CFU/g$, $1.42mg{\cdot}C/m^3{\cdot}hr$ respectively. These biomass and activity values were decreased 99% and 72% in biofilter and 68% and 53% in BAC compared with initial condition. The biodegradation rate constant ($k_{bio}$) and half-life ($t_{1/2}$) in BAC were decreased from $1.173min^{-1}$ to $0.183min^{-1}$ and 0.591 min to 3.787 min respectively according to increasing the $H_2O_2$ concentration from 10 mg/L to 300 mg/L at $5^{\circ}C$ water temperature and the $k_{bio}$ and $t_{1/2}$ were $1.510min^{-1}$ to $0.498min^{-1}$ and 0.459 min to 1.392 min at $25^{\circ}C$ water temperature. By increasing the water temperature from $5^{\circ}C$ to $15^{\circ}C$ or $25^{\circ}C$, the $k_{bio}$ were increased 1.1~2.1 times and 1.3~4.4 times. If a water treatment plant operating $O_3/BAC$ process is considering the hydrogen peroxide for the peroxone process, post BAC could effectively decrease the residual $H_2O_2$, moreover, in case of spilling the $H_2O_2$ into the water process line, these spilled $H_2O_2$ concentration can be able to decrease by increasing the EBCT at the BAC process.

Low Dose Cisplatin as a Radiation Sensitizer in Management of Locally Advanced Scluamous Cell Carcinoma of the Uterine Cervix : Evaluation of Acute Toxicity and Early Response (국소 진행된 자궁경부암의 방사선치료와 저용량 cisplatin 항암요법 동시치료시 급성독성 밀 초기반응 평가)

  • Kim Hunjung;Cho Young Kap;Kim Chulsu;Kim Woo Chul;Lee Sukho;Loh J K
    • Radiation Oncology Journal
    • /
    • v.17 no.2
    • /
    • pp.113-119
    • /
    • 1999
  • Purpose : To evaluate possible acute toxicity and early response of concurrent radiation therapy and low dose daily cisplatin as a radiosensitizer in patients with locally advanced uterine cervical carcinomas. Materials and Method : From December 1996 to January 1999, 38 previously untreated Patients with locally advanced squamous cell carcinoma of the uterine cervix (from stage IIB to stage IIIB) were treated at Inha University Hospital. All patients underwent standard pretreatment staging Procedures after the initial evaluation by gynecologists and radiation oncologists. Sixteen Patients with huge cervical mass (>4 cm) were submitted to the group treated with concurrent radiation therapy and low dose daily cisplatin while the remainder was treated with radiation therapy alone. Radiation therapy consisted of 4500 cGy external beam irradiation to whole pelvis (midline block after 3000 cGy), 900$\~$1000 cGy boost to involved parametrium, and high dose-rate intracavitary brachytherapy (a total dose of 3000$\~$3500 cGy/500 cGy per fraction to point A, twice per week). In the group treated with low dose cisplatin concurrently, 10 mg of daily intravenous cisplatin was given from the 1st day of radiation therapy to the 20th day of radiation therapy. Acute toxicity was measured according to expanded common toxicity criteria of the NCI (C) Clinical Trials. Early response data were analyzed at minimum 4 weeks' follow-up after completion of the treatment protocol. Results: Hematolgic toxici쇼 was more prominent in patients treated with radiation therapy and cisplatin. Six of 16 patients (37.5$\~$) treated with radiation therapy and cisplatin and one of 22 patients (4.5$\~$) treated with radiation therapy alone experienced grade 3 leukopenia. In Fisher's exact test, there was statistically significant difference between two groups regarding leukopenia (P=0.030). There was no apparent difference in the frequency of gastrointestinal and genitourinary toxicity between two groups (P=0.066). Three of 16 patients (18.7$\~$) treated with radiation therapy and cisplatin and two of 22 patients (9.1$\~$) treated with radiation therapy alone experienced more than 5 kg weight loss during the treatment. There was no statistically significant difference on weight loss between two groups (P=0.63). Two patients on each group were not evaluable for the early response because of incomplete treatment. The complete response rate at four weeks' follow-up was 80$\~$(16/20) for the radiation therapy alone group and 78$\~$ (11/14) for the radiation therapy and cisplatin group. There was no statistically significant difference in early response between two treatment groups (P=0.126). Conclusion : This study led to the conclusion that the hematologic toxicity from the treatment with concurrent radiation therapy and low dose daily cisplatin seems to be more prominent than that from the treatment of radiation therapy alone. There was no grade 4 hematologic toxicity or mortality in both groups. The hematologic toxicity in both treatment groups seems to be well managable modically. Since the risk factors were not balanced between two treatment groups, the direct comparison of early response of both groups was not possible. However, preliminary results regarding early response for patients with bulky cervical tumor mass treated with radiation therapy and low dose daily cisplatin was encouraging. Longer follow-up is necessary to evaluate the survival data. A phase III study is needed to evaluate the efficacy of concurrent daily low dose cisplatin with radiation therapy in bulky cervical cancer.

  • PDF

An Analysis on Factors Affecting Local Control and Survival in Nasopharvngeal Carcinoma (비인두암의 국소 종양 치유와 생존율에 관한 예후 인자 분석)

  • Chung Woong-Ki;Cho Jae-Shik;Park Seung Jin;Lee Jae-Hong;Ahn Sung Ja;Nam Taek Keun;Choi Chan;Noh Young Hee;Nah Byung Sik
    • Radiation Oncology Journal
    • /
    • v.17 no.2
    • /
    • pp.91-99
    • /
    • 1999
  • Propose : This study was performed to find out the prognostic factors affecting local control, survival and disease free survival rate in nasopharyngeal carcinomas treated with chemotherapy and radiation therapy. Materials and Methods : We analysed 47 patients of nasopharyngeal carcinomas, histologically confirmed and treated at Chonnam University Hospital between July 1986 and June 1996, retrospectively. Range of patients' age were from 16 to 80 years (median; 52 years). Thirty three (70$\%$) patients was male. Histological types were composed of 3 (6$\%$) keratinizing, 30 (64$\%$) nonkeratinizing squamous cell carcinoma and 13 (28$\%$) undifferentiated carcinoma. Histoiogicai type was not known in 1 patient (2$\%$). We restaged according to the staging system of 1997 American Joint Committee on Cancer Forty seven patients were recorded as follows: 71: 11 (23$\%$), T2a; 6 (13$\%$), T2b; 9 (19$\%$), 73; 7 (15$\%$), 74: 14 (30$\%$), and NO; 7 (15$\%$), Nl: 14 (30$\%$), N2; 21 (45%), N3: 5 (10%). Clinical staging was grouped as follows: Stage 1; 2 (4$\%$), IIA: 2 (4$\%$), IIB; 10 (21$\%$), III; 14 (30$\%$), IVA; 14 (30$\%$) and IVB; 5 (11$\%$). Radiation therapy was done using 6 MV and 10 MV X- ray of linear accelerator. Electron beam was used for the Iymph nodes of posterior neck after 4500 cGy. The range of total radiation dose delivered to the primary tumor was from 6120 to 7920 cGy (median; 7020 cGy). Neoadjuvant chemotherapy was performed with cisplatin +5-fluorouracil (25 patients) or cisplatin+pepleomycin (17 patients) with one to three cycles. Five patients did not received chemotherapy. Local control rate, survival and disease free suwival rate were calculated by Kaplan-Meier method. Generalized Wilcoxon test was used to evaluate the difference of survival rates between groups. multivariate analysis using Cox proportional hazard model was done for finding prognostic factors. Results: Local control rate was 81$\%$ in 5 year. Five year survival rate was 60$\%$ (median survival; 100 months). We included age, sex, cranial nerve deflicit, histologic type, stage group, chemotherapy, elapsed days between chemotherapy and radiotherapy, total radiation dose, period of radiotherapy as potential prognostic factors in multivariate analysis. As a result, cranial none deficit (P=0.004) had statistical significance in local control rate. Stage group and total radiation dose were significant prognostic factors in survival (P=0.000, P=0.012), and in disease free survival rates (P=0.003, P=0.008), respectively. Common complications were xerostomia, tooth and ear problems. Hypothyroidism was developed in 2 patients. Conclusion : In our study, cranial none deficit was a significant prognostic factor in local control rate, and stage group and total radiation dose were significant factors in both survival and disease free survival of nasopharyngeal carcinoma. We have concluded that chemotherapy and radiotherapy used in our patients were effective without any serious complication.

  • PDF

Results of Hyperfractionated Radiation Therapy in Bulky Stage Ib, IIa, and IIb Uterine Cervical Cancer (종괴가 큰 병기 Ib, IIa, IIb 자궁경부암에서 다분할 방사선치료의 결과)

  • Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.349-356
    • /
    • 1997
  • Purpose : To evaluate the efficacy of hyperfractionated radiation therapy in carcinoma of the cervix, especially on huge exophytic and endophytic stage Ib, IIa and IIb Materials and Materials : Fourty one patients with carcinoma of the cervix treated with hyperfractionated radiation therapy at the Department of Therapeutic Radiology, Dongsan Hospital, Keimyung University. School of Medicine from Jul, 1991 to Apr, 1994. According to FIGO s1aging system, therewere stage Ib (3 patients) IIa (6 patients) with exophytic ($\geq$5cm in dinmeter) and huge endophytic mass. and IIb (32 patients) with median age of 55 yeavs old. Radiation therapy consisted of hyperfractionated external irradition to the whole pelvis (120cGy/fraction, 2 fraction/day (minimum interval of 6 hours), 3600-5520cGy) and boost parametrial doses (for a total of 4480-6480cGy) with midline shield $(4\times10cm)$, and combined with intracavitary irradiation (up to 7480-8520cGy in Ib, IIa and 8480-9980cGy in IIb to point A). The maximum and mean follow up durations were 70 and 47 months respectively . Results : Five year local control rate was $78\%$ and the actuarial overall five year survival rate was $66.1\%$ for all patients, $44.4\%$ for stage Ib, IIa and $71.4\%$ for stage IIb. In bulky IIb (above 5cm in tumor size, 11 patients) five year local control rate and five rear survival rate was $88.9\%,\;73\%$ respectively Pelvic lymph node status (negative : $74\%,\;positive:25\%$, p=0.0015) was significant Prognostic factor affecting to five rear survival rate. There was marginally significant survival difference by total dose to A point ($>84Gy\;:\;70\%,\;>84Gy\;:\;42.8\%$, p=0.1). We consider that the difference of total dose to A point by stage (mean Ib,IIa : 79Gy. IIb 89Gy P=0.001) is one of the causes in worse local control and survival of Ib,IIa than IIb The overall recurrence rate was $39\%$ (16/41). The rates of local failure alone. distant failure alone. and combined local and distant failure were $9.7\%,\;19.5\%,\;and\;9.7\%$, respectively. Two Patients developed leukopenia ($\geq$ grade 3) and Three patients develoued grade 3 gastrointestinal complication. Above grade 3 complication was not noted. There was no treatment related death noted. Conclusion : We thought that it may be necessary to increase A point dose to more than 85Gy in hyperfractionated radiotherapy of huge exophytic and endophvtic stage Ib,IIa. We considered that hyperfractionated radiation therapy may be tolerable in huge exophytic and endophytic stage IIb cervical carcinoma with acceptable morbidity and possible survival gain but this was results in small patient group and will be confirmed by long term follow up in many patients.

  • PDF