• 제목/요약/키워드: 기류유인팬

검색결과 3건 처리시간 0.019초

돔경기장의 공조방식에 따른 겨울철 열환경 분석 (The Analysis of Indoor Thermal Environment for Air Condition System in Dome Stadium)

  • 석호태;양정훈;채문병
    • 한국공간구조학회논문집
    • /
    • 제9권2호
    • /
    • pp.53-63
    • /
    • 2009
  • 본 연구에서는 국내 돔경기장을 해석대상공간으로 선정하여 기존 공조방식과 국외 돔경기장에서 사용한 공조방식을 적용하여 겨울철 실내기류 및 온도분포를 분석하고, 열고온층을 해소하기 위한 방안으로 설치된 기류유인팬의 적절성을 검토하였다.

  • PDF

기류유인팬을 이용한 새 국립중앙박물관 로튠다에서의 열환경 평가 (Evaluation on Thermal Environment Installed Ventilating Fans in the Rotunda at New National Museum of Korea)

  • 이승철
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.303-309
    • /
    • 2004
  • In order to improve thermal comfort in the Rotunda, which is high and wide visiting space of the new national museum of Korea, eight ventilating fans were installed near the ceiling of Rotunda. It has been analyzed thermal comfort of Rotunda with/without ventilating fans by numerical simulation. To evaluate thermal comfort of the Rotunda, well-known indices, PMV and PPD were introduced. The results of present investigation show that temperature distribution of the case with fans is closer to target temperature than the case with-out fans at the breathing zone. In the case without fans, thermal stratification with 16$^{\circ}C$ of temperature difference occurs along the height of the Rotunda which makes the thermal environment worse and the PPD values reach up to 50% in the 6th floor connection passage. In the case with fans, however, the vertical temperature difference were reduced to 9$^{\circ}C$ and the PPD values were lower below 20%. Consequently, the ventilating fans adopted on this study are effectively used for improving the thermal comfort in large space structure with thermal stratification.

지하 주차장의 환기성능평가에 관한 연구 (A Study on Estimation of Ventilation Performance in the Underground Parking Lot)

  • 황민규;김성식;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.71-77
    • /
    • 2007
  • In past, parking lot was placed on the ground and for the reason air quality was not in problem. But recently parking lot has been placed under the ground and the air quality becomes problem. So in this study, the ventilation performance on the underground parking lot was estimated by using CFD software and alternative system was suggested. Three case studies are handled in this study. 1st case is just an underground parking lot. 2nd case is about an underground parking lot where has 4 fan rooms on each floor and 3rd case is about an underground parking lot where has 4 fan rooms and 30 guidance fans on each floor.