• Title/Summary/Keyword: 기록지진

Search Result 308, Processing Time 0.025 seconds

Identification of Structural Dynamic Systems (구조물의 동특성 추정방법에 관한 연구)

  • 윤정방;소봉정선
    • Computational Structural Engineering
    • /
    • v.2 no.2
    • /
    • pp.113-119
    • /
    • 1989
  • Methods for identification of modal properties of linear structures are presented. The extended Kalman filtering technique is employed. The state equation is formulated by two different ways, namely by the time domain and frequency domain approaches. Verifications are carried out by using the simulated records of ground acceleration and structural response. Then the techniques are applied to the estimation of modal parameters of a scaled model for a 3-story building which is installed on a shaking table.

  • PDF

Input Ground Motion for the Seismic Analysis of Embedded Structures (반지하구조물 내진설계를 위한 지반거동)

  • 김용석
    • Computational Structural Engineering
    • /
    • v.1 no.2
    • /
    • pp.91-100
    • /
    • 1988
  • 최근 구조물과 지반간의 상호작용이 원자력 발전시설, 해상구조물, 기계기초 등에 대한 내진설계시 매우 중요하다는 것이 일반화되고 있다. 그러나 지금까지 구조물 내진설계시 이러한 구조물이나 지반의 특성이 무시됐었다. 내진설계상 구조물 밑에 있는 지반에 의한 세가지 주된 영향은 Soil Amplification, Kinematic Interaction과 Inertial Interaction이다. 이 논문에서는 반지하구조물 내진설계시 필요한 지반거동을 Soil Amplification과 Kinematic Interaction을 고려하여 구하였으며, 1971년 San Fernando 지진기록으로부터 그 특성을 실제적으로 입증하였다.

  • PDF

Response Characteristics According to the Selection Procedure of Near Field EQGMS (Near field 지진기록 분류에 따른 특성 비교)

  • 배미혜;한상환
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.527-532
    • /
    • 2002
  • Near field ground motions contain distinct and large amplitude pulses in both velocity and displacement. This paper investigates characteristics of near field earthquakes and their effects on seismic demands. 20 EQGMs were selected for this purpose that satisfied 5 conditions for Near field motion. Among them ten EQGMs have one distinct peak velocity pulse in the velocity time history. In this study the responsed are Linear Elastic Response Spectrum(LERS), Response Modification Factor(R) and Inelastic Response Spectrum(IRS). The effect of the selection of Near field EQGMs on these response parameters are investigated.

  • PDF

Stochastic Prediction of Strong Ground Motions in Southern Korea (추계학적 보사법을 이용한 한반도 남부에서의 강지진동 연구)

  • 조남대;박창업
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.4
    • /
    • pp.17-26
    • /
    • 2001
  • In order to estimate peak ground motions and frequency characteristics of strong ground motions in southern korea, we employed the stochastic simulation method with the moment magnitude(M$_{w}$) and the hypocentral distance(R). We estimated same input parameters that account for specific properties of source and propagation processes, and applied them to the stochastic simulation method. The stress drop($\Delta$$\sigma$) of 100-bar was estimated considering results of research in ENA, China, and southern korea. The attenuation parameter x was calculated by analyzing 57 seismograms recorded from September 1996 to October 1997 and the estimation result of the attenuation parameter x is 0.00112+0.000224 R where R is hypocenter distance. We estimated strong ground motion relations using the stochastic simulation method with suitable input parameters(e.g. $\Delta$$\sigma$, x, and so on). At last, we derived relations between hypocentral distances and ground motions(seismic attenuation equation) using results of the stochastic prediction.esults of the stochastic prediction.n.

  • PDF

Fault plane solutions of the December 13, 1996 Yeongweol earthquake (1996년 12월 13일 영월지진의 진원단층면 방향)

  • Park, Chang Eop;Sin, Jin Su;Ji, Heon Cheol;Gang, Ik Beom;Ryu, Yong Gyu
    • Journal of the Korean Geophysical Society
    • /
    • v.1 no.1
    • /
    • pp.23-30
    • /
    • 1998
  • Fault-plane solutions of the December 13, 1996 Yeongweol earthquake with magnitude 4.5 is obtained using the grid test technique. Thirty polarities of P waves recorded at KMA, KIGAM, KSRS and JAPAN stations are used for the event. The obtained fault plane solution shows strike-slip motion with significant amount of thrust component. The orientation of the fault is 180±20° in strike, 50±5° in dip and 150±5° in rake, or 292±3° in strike, 65±5° in dip and 30±10° in rake. These solutions are similar to those of earthquakes occurred at Sagju (Jan. 7, 1980), Pohang (Apr. 15, 1981) and offshore Gunsan (Oct. 6, 1976). The compressional axis of the stress field is trending from ENE to WSW, which is consistent with the previously defined typical regional tectonic stress orientation in and around Korean Peninsula.

  • PDF

Seismic Evaluation of Supporting Reactions for the Bridge with Various Curvatures and Skew Angles (지진하중 하에서 교량 곡률과 사각 크기에 따른 받침부의 반력 검토)

  • Park, Seong-Ryel;Kim, Yun-Tae;Kim, Sang-Chel
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.67-73
    • /
    • 2017
  • This study has addressed to evaluate the effects of radius of curvature and skew angle on the negative reaction in a plate girder bridge with LRB (Lead Rubber Bearing) supports. As analytical parameters, various radius of curvatures and skew angles were selected and two seismic loads of El-Centro and artificial earthquakes were applied to the bridge in the longitudinal and transverse directions. As results of 3D analysis, the possibility of negative reaction is shown at the part of acute angle and inner side of the curved bridge, and becomes increased when seismic load is applied in the transverse direction. In addition, the occurrence of negative reaction is found to be increased as both radius of curvature and skew angle decrease, which means that curved bridge has higher possibility of negative reaction than straight one. Conclusively, all of earthquake wave, gradient, radius of curvature and skew angle should be considered together to investigate the possibility of negative reaction at the bridge support subject to seismic load.

Energy Demand in Steel Structures with Buckling Restrained Braces (좌굴이 방지된 가새가 설치된 철골조 건물의 에너지 요구량)

  • 최현훈;김진구
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.29-37
    • /
    • 2003
  • In this study, a story-wise distribution of hysteretic energy in steel moment resisting framse(MRF), buckling restrained braced frames(BRBF), and hinge-connected framed structures with buckling restrained braces(HBRBF) subjected to various earthquake ground excitations was investigated. Sixty earthquake ground motions recorded in different soil conditions were used to compute the energy demand in model structure. According to analysis results, the hysteretic energy in MRF and BRBF turned out to be the maximum at the base and monotonically diminishes with increasing height. However the story-wise distribution of hysteretic energy in HBRBF was relatively uniform over the height of the structure. In this case damage is not concentrated in a single story, and therefore it is considered to be more desirable than other systems. The story-wise energy distribution pattern under three different soil types turned out to be approximately the same.

A New Detailed Assessment for Liquefaction Potential Based on the Liquefaction Driving Effect of the Real Earthquake Motion (실지진하중의 액상화 발생특성에 기초한 액상화 상세평가법)

  • 최재순;강한수;김수일
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.5
    • /
    • pp.145-159
    • /
    • 2004
  • The conventional method for assessment of liquefaction potential proposed by Seed and Idriss has been widely used in most countries because of simplicity of tests. Even though various data such as stress, strain, stress path, and excess pore water pressure can be obtained from the dynamic test, especially, two simple experimental data such as the maximum deviatoric stress and the number of cycles at liquefaction have been used in the conventional assessment. In this study, a new detailed assessment for liquefaction potential to reflect both characteristics of real earthquake motion and dynamic soil resistance is proposed and verified. In the assessment, the safety factor of the liquefaction potential at a given depth of a site can be obtained by the ratio of a resistible cumulative plastic shear strain determined through the performance of the conventional cyclic test and a driving cumulative plastic shear strain calculated from the shear strain time history through the ground response analysis. The last point to cumulate the driving plastic shear strain to initiate soil liquefaction is important for this assessment. From the result of cyclic triaxial test using real earthquake motions, it was concluded that liquefaction under the impact-type earthquake loads would initiate as soon as a peak loading signal was reached. The driving cumulative plastic shear strain, therefore, can be determined by adding all plastic shear strains obtained from the ground response analysis up to the peak point. Through the verification of the proposed assessment, it can be concluded that the proposed assessment for liquefaction potential can be a progressive method to reflect both characteristics of the unique soil resistance and earthquake parameters such as peak earthquake signal, significant duration time, earthquake loading type, and magnitude.

A Study on the Applicability of Arias Intensity Liquefaction Assessment (Arias Intensity 액상화 평가기법의 적용성에 관한 연구)

  • Hwang, Jungtae;Lee, Jongkeun;Shin, Eunchul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.6
    • /
    • pp.13-19
    • /
    • 2013
  • In this study, the target ground was selected for the assessment of liquefaction, for which energy-based Arias intensity liquefaction assessment method was applied, The results of evaluation by simplified method using conventional in-situ test were compared. The result of the assessment of liquefaction revealed that the safety factor of the Arias Intensity using the actual records of the Hachinohe and Ofunato earthquake showed generally similar trends with the simplified method, However, the Arias Intensity factor of safety for the artificial earthquake created from the design response spectrum showed some difference from the factors of safety of the simplified method. The shear stress ratio and the occurrence strength of the Arias Intensity are differently calculated between stress and energy, but the resistance stress ratio of the simplified method and the resistance strength of the Arias Intensity use the empirical chart of the results of the standard penetration test for the actual liquefaction areas by the earthquake, which seems the reason for the similar results between Arias Intensity assessment and stress concept simplified method for Hachinohe and Ofunato earthquakes. Therefore, it was found that the energy-based Arias Intensity liquefaction assessment could represent the dynamic changes of the ground caused by seismic characteristics such as acceleration, magnitude, duration and amplitude.

Determining the Orientations of Broadband Stations in South Korea using Ambient Noise Cross-correlation (배경잡음 교차상관을 이용한 국내 광대역 지진계의 방위각 보정값 측정)

  • Lee, Sang-Jun;Rhie, Junkee
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.2
    • /
    • pp.85-90
    • /
    • 2015
  • Orientation corrections for Korean seismic stations were calculated by using ambient noise cross-correlation. This method uses Rayleigh waves extracted from ambient noise cross-correlation instead of teleseismic waveforms from earthquakes, which have been generally used for previous studies. The theoretical background of the method is that the phase of radial-vertical cross-correlation function should be the same as that of $90^{\circ}$ phase-shifted vertical-vertical cross-correlation function. The results calculated from stacked cross-correlograms from Jan. 2007 to Sep. 2008 are comparable to the previous results obtained from teleseismic waveforms. In addition, overall the standard deviations of orientation corrections are less than $5^{\circ}$. The temporal variation in orientation corrections calculated for every 30 days shows no significant change and also standard deviations of them are mostly less than $5^{\circ}$. This means that the orientations of stations used in this study have been kept constant during the period. The sensitivity test for stacking period of the ambient noise cross-correlation method shows that continuous ambient noise record of at least about 30 days is required for estimating reliable orientation corrections.