• Title/Summary/Keyword: 기록물(記錄物)

Search Result 1,738, Processing Time 0.03 seconds

Estimates of Surface Explosion Energy Based on the Transmission Loss Correction for Infrasound Observations in Regional Distances (인프라사운드 대기 전파 투과손실 보정을 통한 원거리 지표폭발 에너지 추정)

  • Che, Il-Young;Kim, Inho
    • Journal of the Korean earth science society
    • /
    • v.41 no.5
    • /
    • pp.478-489
    • /
    • 2020
  • This study presents an analysis of infrasonic signals from two accidental explosions in Gwangyang city, Jeonnam Province, Korea, on December 24, 2019, recorded at 12 infrasound stations located 151-435 km away. Infrasound propagation refracted at an altitude of ~40 km owing to higher stratospheric wind in the NNW direction, resulting in favorable detection at stations in that direction. However, tropospheric phases were observed at stations located in the NE and E directions from the explosion site because of the strong west wind jet formed at ~10 km. The transmission losses on the propagation path were calculated using the effective sound velocity structure and parabolic equation modeling. Based on the losses, the observed signal amplitudes were corrected, and overpressures were estimated at the reference distance. From the overpressures, the source energy was evaluated through the overpressure-explosive charge relationship. The two explosions were found to have energies equivalent to 14 and 65 kg TNT, respectively. At the first explosion, a flying fragment forced by an explosive shock wave was observed in the air. The energy causing the flying fragment was estimated to be equivalent to 49 kg or less of TNT, obtained from the relationship between the fragment motion and overpressure. Our infrasound propagation modeling is available to constrain the source energy for remote explosions. To enhance the confidence in energy estimations, further studies are required to reflect the uncertainty of the atmospheric structure models on the estimations and to verify the relationships by various ground truth explosions.

A Retrospective Study of Survival Rate in single Brnemark TiUniteTM Implant (단일 치아 결손시 TiUniteTM 표면 처리한 임플란트의 생존율에 대한 후향적 연구)

  • Kim, Hye-Jin;Yang, Seung-Min;Kye, Seung-Beom;Shin, Seung-Yun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.267-277
    • /
    • 2009
  • Recently implant supported single crown is the popular treatment option to replace a single missing tooth. The purpose of this retrospective study was to analyze and evaluate the survival of implants with the $TiUnite^{TM}$ surface for single tooth replacement. From September 2002 to December 2006, 269 TiUniteTM surfaced implants were used in single tooth replacements at the Institute of Oral Health Science, Samsung Medical Center. Twenty one cases were excluded because of neighbor implants, missing records & short follow up period. Among 248 implants, the 129 implants (52.0%) were inserted in the maxilla and 119 (48.0%) in the mandible. One hundred implants placement (40.3%) were combined with guided bone regeneration, and 36 implants placement (14.5%) were combined with sinus bone augmentation. Mean observation period was $26.0{\pm}11.8$ months after implant placement. Twelve implants were recorded as failures, rendering a single implant survival rate of 95.2% over the observation period. Among failed 12 implants, 10 implants placed in the maxilla. The survival rate in the maxilla was 92.2% and in the mandible was 98.3%. The use of $TiUnite^{TM}$ surfaced single implant placement showed high survival rate for short time period.

Output-Only System Identification and Model Updating for Performance Evaluation of Tall Buildings (초고층건물의 성능평가를 위한 응답의존 시스템판별 및 모델향상)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.19-33
    • /
    • 2008
  • Dynamic response measurements from natural excitation were carried out for 25- and 42-story buildings to evaluate their inherent properties, such as natural frequencies, mode shapes and damping ratios. Both are reinforced concrete buildings adopting a core wall, or with shear walls as the major lateral force resisting system, but frames are added in the plan or elevation. In particular, shear walls in a 25-story building are converted to frames from the 4th floor level downwards while maintaining a core wall throughout, resulting in a fairly complex structure. Due to this, along with similar stiffness characteristics in the principal directions, significantly coupled and closely spaced modes of motion are expected in this building, making identification rather difficult. By using various state-of-the-art system identification methods, the modal parameters are extracted, and the results are then compared. Three frequency-domain and four time-domain based operational modal identification methods are considered. Overall, all natural frequencies and damping ratios estimated from the different identification methods showed a greater consistency for both buildings, while mode shapes exhibited some degree of discrepancy, varying from method to method. On the other hand, in comparison with analysis results obtained using the initial finite element(FE) models, test results exhibited a significant difference of about doubled frequencies, at least for the three lower modes in both buildings. To improve the correlation between test and analysis, a few manual schemes of FE model updating based on plausible reasons have been applied, and acceptable results are obtained. The advantages and disadvantages of each identification method used are addressed, and some difficulties that might arise from the updating of FE models, including automatic procedures, for such large structures are carefully discussed.

Characteristics of Silica Coated ${\gamma}-Fe_{2}O_{3}$ with Heat-treatment (열처리에 따른 실리카 피착 ${\gamma}-Fe_{2}O_{3}$의 특성)

  • Lee, J.Y.;Byeon, T.B.;Kim, D.Y.;Lee, H.;Han, K.H.;Sohn, J.G.
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.2
    • /
    • pp.108-114
    • /
    • 1993
  • This paper presents a study on the effects of silica coating in the production of ${\gamma}-Fe_{2}O_{3}$ powders suitable for magnetic recording media. Emphasis has been put on investigating the relationship between the powder characteristics and the effects of silica coating in the heat-treatment stage of ${\gamma}-Fe_{2}O_{3}$ production. After we prepared non-coated ${\gamma}-Fe_{2}O_{3}$ and silica coated ${\gamma}-Fe_{2}O_{3}$ with coating water glass on the surface of goethite and heattreatment process, we compared and investigated powder characteristics. As silica coated layer played a role of preventing the powders from overreduction to metal iron and rapid oxidation, silica coated ${\gamma}-Fe_{2}O_{3}$ showed superior magnetization value due to inhibiting t!1e adulteration of ${\alpha}-Fe_{2}O_{3}$ into the final product. When silica coated layer acted as a sintering restrainer, silica coated ${\gamma}-Fe_{2}O_{3}$ showed high coercivity and specific sur-face area due to good acicularity.

  • PDF

A Study on Establishing a Port Business Valley in Incheon Port (인천항 포트비즈니스밸리 전략 수립에 관한 연구)

  • Kim, Un-Soo;Ahn, Woo-Chul
    • Journal of Korea Port Economic Association
    • /
    • v.28 no.2
    • /
    • pp.1-27
    • /
    • 2012
  • As more manufacturing and global businesses are being pulled into the port area, the idea of a Port Business Valley (PBV) is being pondered as it would create jobs and added value. The PBV would be centered around the harbor and be connected to the port, a logistics district, an industrial district, and the city. The resulting domestic and foreign investment in logistics, industry, business, tourism, living, etc. would vitalize the geographical characteristics of Incheon Port. It would also generate the largest amount of ripple effects between industries in the PBV. However, up until recently, the most frequently offered examples of planning that have helped logistics of a port to grow that have used a PBV have been those of Busan New Port and Gwangyang Port. However, this study is the result of the recent inception of the idea of creating a PBV centered around Incheon Port and the need for experts to develop a plan for such a PBV in Incheon by conducting a site specific study. The aim of this study is to set up the concept of PBV and establish PBV model of Incheon Port. In addition, this study identifies construct factors and their strategies for establish PBV of Incheon Port and then, shows the key factors and related-strategies on Fuzzy-AHP analysis from a survey of logistics experts with Incheon Port.

An Experimental Study on Seismic Damage Indicator Considering Cumulative Absolute Velocity Concept (누적절대속도 개념을 고려한 지진손상표시기의 실험적 연구)

  • 이종림;권기주;이상훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.3
    • /
    • pp.65-71
    • /
    • 2001
  • The nuclear power plant(NPP) should be shut down for inspection and tests prior to a return to power if the earthquake exceeds the operating basis earthquake(OBE). The OBE at the plant is considered to have been exceeded if the computed cumulative absolute velocity(CAV) from the earthquake record is greater than 0.16g-sec. However, the CAV criterion should be determined considering the seismic and structural characteristics of the plant. An experimental study using shaking table is conducted in this study to evaluate intensity of CAV criterion. Appropriate level of CAV is evaluated based on the test results using the developed seismic damage indicator(SDI) model. The model consists of stacked acrylic cylinders and is developed to behave consistently for each directional seismic load. The result of the experimental study in dicates that the CAV criterion of 0.16g-sec is conservative enough to be applied to Korean NPPs since the CAV value of the seismic input motion of the Korean standard NPPs ranges from 0.3 to 0.5 g-sec. The developed SDI is expected to be useful not only in easily determining OBE exceedance but also in evaluating earthquake damage quantitatively to provide guidelines for better post-shutdown inspection and test.

  • PDF

A Review of Magnetic Exploration in Korea (한국의 육상 자력탐사)

  • Park, Yeong-Sue
    • Economic and Environmental Geology
    • /
    • v.39 no.4 s.179
    • /
    • pp.403-416
    • /
    • 2006
  • Magnetic method is rapid, cheap and simple geophysical exploration technique, and has wide range of applications such as resources prospecting, geological structure investigation and even geotechnical and environmental problems. Especially, aeromagnetics gives fundamental and useful geoscientific data fnr not only assessment of potential resources, but also national land planning. Magnetic method, perhaps the oldest geophysical technique, was relatively early introduced into Korea. Documents during Japanese occupation says that magnetic method was used for exploring metallic ore deposits and hot spring, and that a geomagnetic observatory was operated. From mid 1950's, after Korean War, magnetic explorations for natural resources such as metallic ore, uranium, coal, and groundwater were intensively executed for industrialization. Apache aeromagnetic survey project during $1958{\sim}1959$ and its ground follow-up surveys are typical and important cases in those days. Magnetic survey techniques were rapidly advanced during 1970's and 1980's with improvements of instruments, growth of geophysical manpower, and availability of computers. The national aeromagnetic mapping project by KIGAM in 1981 showed the improved technical capability of those days. Decline of mining industry since mid 1980's moved the exploration objects from traditional resources to new ones such as groundwater and geothermal resources, and applications to investigation of geological structure were revived. Recently appeared applications such as natural hazard assessment, and engineering and environmental studies increased the magnetic method's utility in the realm of exploration.

A study in pigment analysis and original mounting of the decorative painting at court (궁중 장식화의 채색 분석과 장황 고찰)

  • Ahn, Ji Yoon;Kim, Soo Yeon;Cheon, Ju Hyun
    • Journal of Conservation Science
    • /
    • v.30 no.1
    • /
    • pp.39-53
    • /
    • 2014
  • The decorative painting at court was practical and functional role by decorated the inside and outside of palace. Especially, the type of the Painting of sun, moon and five peaks and Heavenly peach were the one of representative decorative paintings, produced for authority of king and longevity wish. However, there are not clarify verification of production period and installation place in the Painting of sun, moon and five peaks and Heavenly peach, that made before $19^{th}$ century, in present. Therefore, this study has a meaning on find production period, installation place and techniques of paint through conservation scientific research of the Painting of sun, moon and five peaks and Heavenly peach that introduced the first time in National Museum of Korea. Double side paintings in two-panel folding screen style and tortoise shell shape of window is the first time research in the decorative painting at court. This study also explain that they were installed in Hamin Jeong from ChanggyeongGungyeonggeon Dogam Uigwe(1834) through research of the original measurement, contrast of palace in present and Uigwe record. It will be contributed to a study of the Painting of sun, moon and five peaks and Heavenly peach in the early $19^{th}$ century.

A Development of Test Method on the Energy Consumption Efficiency of Domestic Gas Boiler below 70 kW (70 kW 이하 가정용 가스보일러 에너지소비효율 실험방법 개발)

  • Park, Chanil;Kim, Laehyun
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.73-82
    • /
    • 2016
  • The energy consumption efficiency in a variety of operational test mode was considered for domestic gas boiler below 70 kW. The energy efficiency test carried out in the experimental conditions similar to the actual operation status was analyzed and compared with the current Korean efficiency test method. Four types of test modes for each boiler(Non-condensing and condensing boiler) were carried out in the condition of laboratory mode(full load, steady state) and actual operating mode. Futhermore divided into two operational status for each of these, it was applied by maximum gas consumption and consumer sales conditions. Test equipment has the function referred to gas boiler standards, such as KS or European standard EN. The equipment should be continuously measured and record the measuring factors which are the flow volume of gas and water, laboratory temperature, water flow volume for heating, return water volume after heating and quantity of the exhaust gases(CO, NO, $NO_2$). The experimental results were found that non-condensing boiler efficiency of laboratory mode is about 10% higher than that of actual mode. In case of condensing boiler, the efficiency of laboratory condition is about 20% higher than that of the actual using conditions. I suggest that the government will gradually take the efficiency test method considering the actual conditions.

A Study on the Diel Distribution and Activity Patterns of Fishes in the Korean Eastern Sea (한국 동해 어족생물의 일주기적 유영행동특성에 관한 연구)

  • 이대재;김성기
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.2
    • /
    • pp.85-94
    • /
    • 2001
  • The vertical distribution and activity patterns of fishes during the evening and morning transitions were investigated acoustically and by pelagic trawling on October 2-10, 1997 in the Korean Eastern Sea. The acoustic data were collected from four stations with a scientific echo sounder operating at a frequency of 38 kHz, and the echogram was used to analyze the diel vertical migration of fish. Biological sampling was accomplished by pelagic trawling to identify fish species recorded on the echograms, and the species and length compositions were investigated. Vertical profiles of water temperature, salinity at the trawl station were taken with a CTD system and were related to the diel movement and the depth distribution of fish. During the day, one group of fish mainly distributed above the depth layer of 50 m, the other group was at deeper water, approximately 250 m, but began to migrate toward the surface before sunset with a time difference. During the night, they were dispersed between the surface and the depth of 125 m. Just prior to sunrise, the scattering layer was divided with 2 groups and began to migrate downwards, respectively. Several trials of pelagic trawling for scattering layers suggest that the most dominant scatterer in the survey area of this study was Japanese flying squid, Todarodes pacificus..

  • PDF