• Title/Summary/Keyword: 기둥공극

Search Result 12, Processing Time 0.023 seconds

A Study On Void Check for Top-Down Column Joint by Field Experiment (현장실험을 통한 역타설 이음부의 공극특성 분석)

  • Lee, Young-Do;Jung, Sang-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.1 s.15
    • /
    • pp.105-109
    • /
    • 2005
  • Classified with concrete as placing ways - direct ways, sheath way - and placing directing flange direction, web direction - is analyzed section and strength of hardened concrete. The results of this study is belows the more fluid of concrete, the more useful to top-down method. To minimize the voids of the reverse placement joints, It is more effect to use the sheath method than direct method in concrete placement. If the joint face is a plane, it is impossible to extract the air bubbles which caused voids, so we should consider about this, and decide to select which type of joints.

Evaluation of Cross-Sectional Damage for RC Column Subjected to Axial Loading and Steel Corrosion (철근 부식과 축방향 하중을 받는 철근-콘크리트 기둥 단면의 손상 평가)

  • Changyoung Kim;Ki Yong Ann
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.476-483
    • /
    • 2023
  • The present study concerns modelling the structural behaviour for concrete structure into the crack initiation at corrosion of steels. The degradation source included the axial load and steel corrosion. A development of the rust formed on the steel surface was considered with the interfacial gap between steel and concrete. As a result, the tensile damage could occur on the surface of concrete into the cracking with no steel corrosion, which could be further developed by the increasing rust formation, while the cracking at the steel-concrete interface was mainly attributed to the compressive deformation, being restricted within the interfacial zone.

A Study on Fire Performance of HPC Column with Fiber Cocktail in KS Fire Curve under Loading Condition (표준화재 재하조건에서 Fiber Cocktail을 혼입한 고강도 콘크리트 기둥의 강도별 화재거동에 관한 연구)

  • Kim, Heung-Youl;Chae, Han-Sik;Kim, Hyung-Jun;Jeon, Hyun-Kyu;Youm, Kwang-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.377-380
    • /
    • 2008
  • The material and mechanical properties in the high temperature area of 40 to 100 MPa high strength concrete structural member was identified based on mixing of fiber cocktail and the structural element fire behavior simulation through the finite element analysis method (ABAQUS) was interpreted. The results are as follows. First, it was interpreted that the test specimen with concrete fiber cocktail mixed was more controllable in the maximum shrinkage than the one with concrete fiber cocktail not mixed the controllable range was about 25% to 55%. This means that shrinkage is controllable through mixing of fiber cocktail for the high strength concrete columns. Second, this study didn't consider the explosive spalling by the pore pressure within high strength concrete. If the properties for the pore pressure within high strength concrete is considered and database by strength and by inner temperature of various high strength concrete and steel materials are established in the future, it is interpreted that the technical foundation will be laid for performance based design of fire resistant construction.

  • PDF

A Study on Void Characteristics with V-meter in Top-Down Column Joint Part. (초음파를 이용한 역타기둥 이음부의 공극특성에 관한 연구)

  • 이영도;정상진
    • Journal of the Korea Institute of Building Construction
    • /
    • v.1 no.2
    • /
    • pp.191-195
    • /
    • 2001
  • When top down method is used, it could be a construction method trouble in column joint, between the former concrete and the latter. It could bring a void and weak concrete in column. The purpose of this study is finding a way to prevent concrete void and concrete suitable for top down , through V-metering for top down column and concrete experiment. To minimize the void of reverse placement joint, It is more effect to use the sheath method then direct method in concrete placement.

  • PDF

A Study on Void Examination in Top-Down Column Joint (역타설기둥 타설이음 부분의 공극성상에 관한 연구)

  • 이영도;임형일;김성식;정병훈;정상진;진영헌
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.34-39
    • /
    • 2001
  • When top down method is used, it could be a construction method trouble in column joint, between the former concrete and the latter. It could bring a void and weak concrete in column. The purpose of this study is finding a way to prevent concrete void and concrete suitable for top down, through V-metering for top down column and concrete experiment.

  • PDF

Spalling Reduction Method of High-Strength Reinforced Concrete Columns Using Insulating Mortar (단열모르타르를 이용한 고강도콘크리트 기둥의 폭렬저감 방안)

  • Yoo, Suk-Hyeong;Lim, Seo-Hyeong
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.8-13
    • /
    • 2011
  • High Strength Concrete (HSC) has a disadvantage of the brittle failure under fire due to the spalling. The studies on spalling control method of new constructed HSC buildings were performed enough, but the studies on existing buildings are insufficient. The new inorganic refractory mortar is developed in this study. The insulating capacity is enhanced by using light weight fine aggregate and polypropylene (PP) fiber. In results of material test, the thermal conductivity of light weight fine aggregate get lower than general fine aggregate. And in results of column test, the fire resisting time is delayed 20 minutes by using light weight fine aggregate, 10 minutes by increasing finishing depth from 10 mm to 20 mm and 4 minutes by using 0.6 % PP fiber.

3-D Numerical Experiment for Estimation of Equivalent Resistance Coefficient due to Multi-piers : Effect of Transverse Intervals (상당저항계수식 산정을 위한 3차원 수치실험 : 횡방향 이격거리의 영향)

  • Kim, Hyeong-Seok;Choi, Jun-Woo;Ko, Kwang-Oh;Yoon, Sung-Bum
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.21 no.3
    • /
    • pp.216-223
    • /
    • 2009
  • A transverse drag interaction coefficient of the equivalent resistance coefficient formula for square multi-piers higher than water depth and arranged with equal intervals was studied. From the assumption that the energy loss due to drag interaction according to transverse intervals of resistance bodies is essentially identical to the energy loss due to thick orifice according to porosities, the transverse drag interaction coefficient was derived by employing the orifice's energy loss coefficient. The equivalent resistance coefficient formula including the drag interaction coefficient was compared with the numerical experiments using FLOW-3D, the performance of which was verified by Kim et al.(2008) in the experimental condition with the multi-piers. The comparisons showed good agreement and thus, the equivalent resistance coefficient formula, which does not only consider frictional resistance but also consider the multi-piers' drag resistance varied according to the intervals in longitudinal or transverse direction, was verified.

Development of Digital Filter and Damper for Improving Accuracy of Measurement of Application Amount of Disinfectants of Disinfection Vehicle (방역차량의 약제 살포량 측정 정확성 개선을 위한 디지털 필터와 댐퍼 개발)

  • Baek, Seunghwan;Park, Donghyeok;Park, Hana;Lee, Chungu;Rhee, Joongyong
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.148-148
    • /
    • 2017
  • 방역 차량의 약액탱크, 차량의 연료, 워셔액 등의 탱크 내부에는 잔존량을 측정하기 위해 기둥과 floating box로 이루어진 부력식 수위레벨센서가 사용되고 있으나 액체레벨에 따라 float이 상하로 움직이는 측정원리상 차량 주행 중 정확성이 매우 떨어진다(Park et al. 2016). 방역차량이 주행 중 분사할 때, 슬로싱 현상과 방역소독기의 노즐과 펌프에서 발생하는 진동으로 인해 기존의 부력식 센서를 이용한 약제 살포량 측정방법은 정확성이 매우 떨어지는 경향이 있다. 본 연구의 목적은 방역차량이 주행하면서 분사할 때, 수위레벨 센서를 이용한 약제살포량 측정의 정확성을 개선하는 것으로 디지털 칼만필터, Low pass filter와 댐퍼를 제작하여 이용했다. 본 연구에서는 압력식 레벨센서를 이용해 약액탱크의 높이당 단면적과 수위를 측정하여 약제살포량을 계산했다. Python 2.7을 이용해 디지털 칼만필터와 Low pass filter(LPF)를 구현하였으며 3D프린터를 이용해 댐퍼를 제작했다. 실내에서 슬로싱 현상을 인공적으로 만들어 필터와 댐퍼의 수위 측정 정확성 개선효과를 확인 후 실제 방역차량에 부착하여 비포장도로에서 주행하면서 분사할 때 필터와 댐퍼의 효과를 확인하였다. 댐퍼의 공극률(p)을 바꿔가며 수위 측정 정확성 개선효과를 확인하였다. 실내, 현장 실험 결과, 칼만필터가 LPF보다 개선효과가 더 크지만 데이터 50개 처리에 1.71초의 시간지연이 발생했다. 댐퍼는 수위센서를 고정시키고 유체의 운동을 방해하여 이상치와 큰 오차제거에 효과적이었다. 칼만필터와 댐퍼를 동시에 이용할 경우, 수위 측정정확성 $R^2$는 0.9985, 0.9981로 ${\pm}4.3cm$의 범위내에서 수위를 측정할 수 있었다. 필터의 시간지연과 수위 측정정확성을 고려하여 데이터 기록간격을 3초로 설정하면 ${\pm}3cm$이내에서 약탱크 내 수위를 측정할 수 있었다. 공극률(p)가 0.294, 0.291, 0.17에서 측정정확성 $R^2$는 각각 0.9897, 0.9858, 0.9872 로 p가 0.294에서 개선효과가 가장 좋았으나 개선효과의 차이는 크지 않았다.

  • PDF

Non-destructive Inspection of Construction Joints of Concrete Structures Using the Radar and the Infrared Thermography Method (레이더법과 적외선법을 이용한 콘크리트 시공 이음부 공극의 비파괴검사)

  • Park, Seok-Kyun
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.425-432
    • /
    • 2003
  • The joint treatment of concrete is one of the technical problems in concrete constructions. Joints created with concrete constructions result in serious weakness in the aspects of both structural and water-barrier function. The radar and the infrared thermography method have been used for the non-destructive inspection of several construction joints of concrete structures in this study. The advantages and limitations of these methods are investigated for non-destructive inspection on construction joints of concrete columns. It can be shown that the detecting precision of construction joints using these methods is improved if radar analysis is carried out with a simulation analysis. In case of the infrared thermography method, the shape of construction joints can be also detected when heating is performed before testing. As the result, it has been verified that the construction joints, difficult to be detected by visual inspection, could be inspected effectively in broad areas at short period of time when these two methods are applied.

Evaluation of Hydrogeologic Seal Capacity of Mudstone in the Yeongil Group, Pohang Basin, Korea: Focusing on Mercury Intrusion Capillary Pressure Analysis (포항분지 영일층군 이암층의 수리지질학적 차폐능 평가: 수은 모세관 압입 시험의 결과 분석을 중심으로)

  • Kim, Seon-Ok;Wang, Sookyun;Lee, Minhee
    • Economic and Environmental Geology
    • /
    • v.53 no.1
    • /
    • pp.23-32
    • /
    • 2020
  • Geological CO2 sequestration is a global warming response technology to limit atmospheric emissions by injecting CO2 captured on a large scale into deep geological formations. The presented results concern mineralogical and hydrogeological investigations (FE-SEM, XRD, XRF, and MICP) of mudstone samples from drilling cores of the Pohang basin, which is the research area for the first demonstration-scale CO2 storage project in Korea. They aim to identify the mineral properties of the mudstone constituting the caprock and to quantitatively evaluate the hydrogeologic sealing capacity that directly affects the stability and reliability of geological CO2 storage. Mineralogical analysis showed that the mudstone samples are mainly composed of quartz, K-feldspar, plagioclase and a small amount of pyrite, calcite, clay minerals, etc. Mercury intrusion capillary pressure analysis also showed that the samples generally had uniform particle configurations and pore distribution and there was no distinct correlation between the estimated porosity and air permeability. The allowable CO2 column heights based on the estimated pore-entry pressures and breakthrough pressures were found to be significantly higher than the thickness of the targeting CO2 injection layer. These results showed that the mudstone layers in the Yeongil group, Pohang basin, Korea have sufficient sealing capacity to suppress the leakage of CO2 injected during the demonstration-scale CO2 storage project. It should be noticed, however, that the applicability of results and analyses in this study is limited by the lack of available samples. For rigorous assessment of the sealing efficiency for geological CO2 storage operations, significant efforts on collection and multi-aspect evaluation for core samples over entire caprock formations should be accompanied.