• Title/Summary/Keyword: 기능적 방사선학적 평가

Search Result 105, Processing Time 0.033 seconds

Analysis of the Characteristics of First Permanent Molars with Delayed Eruption (제1대구치 맹출 지연의 유형에 따른 특징 분석)

  • Lee, Hosun;Lee, Koeun;Kim, Misun;Nam, Okhyung;Lee, Hyo-Seol;Choi, Sungchul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.1
    • /
    • pp.95-103
    • /
    • 2022
  • The first permanent molars play a key role in maxillofacial development and occlusion. The purpose of this study is to investigate the characteristics and development stages of first molars with delayed eruption, and to evaluate their associations with congenital missing teeth. Eight-year-old patients who had delayed eruption in their first molars were classified into 75 patients with physical barriers and 77 patients without physical barriers. The development stages of the first and second molars in the delayed area were analyzed using Nolla method from the panoramic radiographs. The relationship between congenital missing teeth and delayed area was also investigated. Delayed eruption of first molars were more common in the maxilla alone. With the presence of physical barriers, male patients showed higher frequency in unilateral cases, while female patients had higher bilateral cases when there was no physical barrier. Delayed development of first molars were observed in delayed eruption area. In the absence of physical barriers, adjacent second molars were also developed slowly and the incidence of congenital missing teeth was high in delayed area. If first molars with delayed eruption are observed, clinical and radiographical follow-ups are necessary for the evaluation of their developmental stages and congenital missing teeth.

The Effect of Exercise Therapy on Pain, Muscle Function and Radiological Evaluation in a Female Youth Golf Player with Low Back Pain: Case Report (치료적 운동이 허리통증을 가진 여자 청소년 골프선수의 통증, 근기능 및 방사선학적 평가에 미치는 영향: 증례보고)

  • Lee, Ho-Seong
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.3
    • /
    • pp.1-9
    • /
    • 2018
  • PURPOSE: The purpose of this study was to determine the effect of exercise therapy on low back pain (LBP), the function of paraspinal and abdominis muscles, and the sacrohorizontal angle as seen on the radiographs of the lumbar spine in a young female golf player with LBP. METHODS: This case report describes an 11-year-old female golfer who presented with LBP. The exercise therapy program comprised lumbar joint mobilization, lumbar spine flexion distraction, abdominal bridge, plank, side plank, and single-leg extensions from a 4-point kneeling position for 40 min/day; this was done twice a week for 8-weeks. LBP [visual analog scale (VAS) and Oswestry disability index (ODI)] and function of paraspinal and abdominis muscles [Ito test, curl-up test, $90^{\circ}$ stop test, squat test, opened eye one leg stance test (OEOL), and closed eye one leg stance test (CEOL)] were measured before and after 4 and 8 weeks of exercise therapy. The radiographs were analyzed for the lumbar Cobb's angle and sacrohorizontal angle before and after 8 weeks of exercise therapy. RESULTS: After 4 and/or 8 weeks of exercise therapy, VAS and ODI scores decreased; results for the Ito test, curl-up test, $90^{\circ}$ stop test, squat test, and OEOL and CEOL of muscle function improved; and the lumbar Cobb's angle and sacrohorizontal angle improved. CONCLUSION: These results suggest that exercise therapy improves LBP, muscle function, and radiographic parameters associated with LBP in young golf players. These findings have clinical implications for exercise therapy in young female golf players who have LBP.

Transmission Dose Estimation Algorithm for Tissue Deficit (조직 결손에 대한 투과선량 계산 알고리즘 보정)

  • Yun Hyong Geun;Chie Eui Kyu;Huh Soon Nyung;Lee Hyoung Koo;Woo Hong Gyun;Shin Kyo Chul;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.186-192
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry. In this study, previous algorithm for estimation of transmission dose was modified for use in cases with tissue deficit. Materials and Methods : The beam data was measured with flat solid phantom in various conditions of tissue deficit. New algorithm for correction of transmission dose for tissue deficit was developed by physical reasoning. The algorithm was tested in experimental settings with irregular contours mimicking breast cancer patients using multiple sheets of solid phantoms. Results : The correction algorithm for tissue deficit could accurately reflect the effect of tissue deficit with errors within ${\pm}1.0\%$ in most situations and within ${\pm}3.0\%$ in experimental settings with irregular contours mimicking breast cancer treatment set-up. Conclusion : Developed algorithm could accurately reflect the effect of tissue deficit and irregularly shaped body contour on transmission dosimetry.

Surgical Treatment of Metastatic Tumor in Pelvis (골반부 전이성 종양의 수술적 치료)

  • Kim, Jae-Do;Park, Woong;Jo, Myung-Rae;Son, Jung-Whan;Lee, Young-Gu
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.2
    • /
    • pp.61-70
    • /
    • 2004
  • Purpose: We studied to decide the operative indication of the metastatic tumor in pelvis according to the oncologic results, the Eastern Cooperative Oncologic Group (ECOG) performance status and complication. Materials and methods: From May 1994 to May 2003, 9 patients who were performed on palliative treatment and 10 paitents on operative treatment due to metastatic tumor of pelvic bone were investigated. On palliative/operative group, the mean age of patients was 57.6/48.0 years old and the ratio of male to female was 5:4/7:3. Primary origins were 3 cases from kidney, 3 from cervix and 2 of lung, 2 of myeloma, 2 of Non-Hodgkin's Lymphoma, and 1 from breast, bladder, testis, prostate, stomach, liver and retroperitoneal leimyosarcoma respectively. The palliative treatment was performed in 5 cases with radiotherapy, 1 with chemotherapy, 2 with combined chemo-radiotherapy and 1 with percutaneous cementation. The operative methods were 1 case of bone cement insertion after curettage, 2 of Girdlestone with internal hemipelvectomy and 7 of reconstruction after wide excision. Reconstructions were done.: 1 case of bone cementation, 5 of autograft prosthesis composite with irradiation or pastuerization and 1 of saddle prosthesis. We have observed the oncologic results, the ECOG performance status and complication. Results: The oncologic results of palliative/operative groups are NED 0/1, AWD 2/6, DOC 1/2 and DOD 6/1. The ECOG performance status was changed from 1.5 into 4.3 in palliative group and from 2.6 into 2.2 in operative group. The complications were 3 cases of the prosthesis failure and 2 of infection. Conclusion: The indication of operation of metastatic pelvic tumor is decided in consideration of the patient's condition, the grade of malignancy in primary tumor and the life expectancy.

  • PDF

In Vivo Dosimetry with MOSFET Detector during Radiotherapy (방사선 치료 중 MOSFET 검출기를 이용한 체표면 선량측정법)

  • Kim Won-Taek;Ki Yong-Gan;Kwon Soo-Il;Lim Sang-Wook;Huh Hyun-Do;Lee Suk;Kwon Byung-Hyun;Kim Dong-Won;Cho Sam-Ju
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.17-23
    • /
    • 2006
  • In Vivo dosimetry is a method to evaluate the radiotherapy; it is used to find the dosimetric and mechanical errors of radiotherapy unit. In this study, on-line In Vivo dosimetry was enabled by measuring the skin dose with MOSFET detectors attached to patient's skin during treatment. MOSFET dosimeters were found to be reproducible and independent on beam directions. MOSFET detectors were positioned on patient's skin underneath of the dose build-up material which was used to minimize dosimetric error. Delivered dose calculated by the plan verification function embedded in the radiotherapy treatment planning system (RTPs), was compared with measured data point by point. The dependency of MOSFET detector used in this study for energy and dose rate agrees with the specification provided by manufacturer within 2% error. Comparing the measured and the calculated point doses of each patient, discrepancy was within 5%. It was enabled to verify the IMRT by using MOSFET detector. However, skin dosimetry using conventional ion chamber and diode detector is limited to the simple radiotherapy.

  • PDF

When do we use the Recycling Autograft in Limb Salvage Surgery? (사지구제술에서 언제 재활용 자가골 이식술이 유용한가?)

  • Kim, Jae-Do;Jang, Jae-Ho;Cho, Yool;Kim, Ji-Youn;Chung, So-Hak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.14 no.2
    • /
    • pp.95-105
    • /
    • 2008
  • Purpose: To identify which is the best procedure in recycling autograft according to the resection & reconstruction type and recycling methods, and so when the recycling autograft is used in limb salvage surgery. Materials and Methods: We have treated fifty-eight patients (34 male, 24 female; age range 5 to 74 years, mean age 36.5 years), who had the malignant musculoskeletal tumors, with recycling autograft (47 patients with extracoporeal irradiation, 11 patients with pasteurization) from December 1995 to February 2006. The resection and reconstruction type was 3 cases with fragmentary, 8 intercalary, 23 rAPC (recycling-Autograft-Prosthesis composite), 18 osteoarticular, 5 total joint and 1 soft tissue (achilles tendon). The result was evaluated by the radiologic union at junctional site, the functional score by musculoskeletal tumor society score and complications according to the resection & reconstruction type and recycling methods. Results: The junctional union was obtained at 15.0 months in extracoporeal irradiation and 12.6 months in pasteurization. Also the mean radiologic union was shown at 6.0 months in fragmentary, 12.8 months in intercalary, 10 months in rAPC, 23.3 months in osteoarticular and 15.6 months in total joint. The functional score was 65.5% in fragmentary, 60.8% in intercalary, 62.8% in APC (except pelvis), 66.0% in osteoarticular and 66.6% in total joint. We have experienced 1 infection, 1 prutrusio acetabuli in pasteurization (18.1%) and other 22 complications (3 deep infections, 8 nonunions, 2 fractures, 2 epiphyseal problems, 5 joint instabilities, 2 local recurrence) in extracoporeal irradiation (46.8%). Also we have experienced 3 complications (3 nonunions) in intercalary (37.5%), 9 complications (4 nonunions, 1 deep infection, 1 periprosthetic fracture, 1 epiphyseal problem, 1 local recurrence, 1 protrusio acetabuli) in rAPC (50.0%), 6 complications (2 deep infections, 2 nonunions, 1 epiphyseal problem, 1 pathologic fracture) in osteoarticular (33.3%), 5 complications (5 joint instabilities) in total joint (100%) and 1 complication(1 local recurrence) in soft tissue (100%). Conclusion: In our experience, according to the resection & reconstruction type fragmentary and intercalary may have several advantages such as good radiologic and functional result and low rate of complication. And it seems that rAPC was available in case which have no sufficient residual bone stock. Also the pasteurization may have more advantages than that of the extracorporeal irradiation.

  • PDF

Posterior cruciate ligament reconstruction using fresh-frozen Achilles tendon allograft with preservation of ligament remnant (남아 있는 인대를 보존하고 신선 동결 동종 아킬레스건을 이용한 후방십자인대 재건술)

  • Kim, Yeung Jin;Chae, Soo Uk;Kim, Jong Yun;Kim, Byung Soo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.2
    • /
    • pp.54-60
    • /
    • 2011
  • Puropse: To evaluate the outcome of arthroscopic posterior cruciate ligament (PCL) reconstruction using fresh-frozen achilles allograft tendon with preservation of ligament remnant or elongated ligament. Materials and Methods: From October 2004 to March 2010, we performed PCL reconstruction with Achilles tendon allografts in 22 complete rupture patients. Mean age was 31.5 years. 14 cases were male and 8 cases were female. Average follow-up period was 3 years and 7 months, range from 1 year to 6 years and 4 months. Subjective and objective parameters were utilized in analyses, such as the mean range of motion, post. drawer test, Lysholm knee score, Tegner activity score, IKDC score, and second look arthroscopic examination. Results: Postoperative Lysholm knee score, IKDC scores, Tegner activity scale, and posterior displacement by the Telos stress test demonstrated statistically significant improvement compared to the preoperative state. Conclusion: Arthroscopic PCL reconstruction using fresh-frozen achilles allograft tendon with preservation of ligament remnant showed good clinical results and posterior stability.

  • PDF

Full mouth prosthetic rehabilitation based on systemic analysis, diagnosis and treatment plan: a case report (체계적 분석, 진단, 치료 계획을 통한 전악 보철 재건 증례)

  • Kwon, Sooyeon;Paek, Janghyun;Pae, Ahran;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.332-338
    • /
    • 2013
  • Data collection including checking the problem list and analyzing the etiology cannot be overemphasized in full mouth rehabilitation cases. It is well reported that favorable prognosis of prosthodontic treatment depends on accurate diagnosis. Seventy seven year old female patient presented with chief complaints of chewing pain on maxillary and mandibular left premolars and unesthetic existing prosthesis. Clinical evaluation, radiographic examination and cast analysis were performed to gather comprehensive data and problem lists. Treatment planning was based on collected data and related articles. Abutment evaluation, prognosis depending on various types of prosthesis, and maintenance were considered as well. Occlusal vertical dimension was increased to solve esthetic dissatisfaction and insufficient interocclusal space. Patient adaptation was verified with provisional restorations followed by diagnostic wax up. Function, esthetics and occlusal stability were verified during 8 week follow-up period. Prosthodontic reconstruction based on systemic analysis, diagnosis, and treatment plan led to satisfactory result after delivery of definitive prosthesis.

Radiographic evaluation of marginal bone resorption around two types of external hex implants : preliminary study (두 종의 external hex implant의 변연골 흡수에 관한 연구 : 예비연구 (preliminary study))

  • Lee, Ji-Eun;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Han, Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.169-174
    • /
    • 2008
  • Statement of problem: Changes of the marginal bone around dental implants have significance not only for the functional maintenance but also for the esthetic success of the implant. It was proposed that bone-retention elements such as microthreads at the coronal part of implant might help maintain the marginal bone level. Purpose: This study was designed to evaluate the effect of microthread configuration within the marginal coronal portion of the implant fixture at the marginal bone changes after loading around two different external hex implants. Material and methods: Twenty-four patients were included and randomly assigned to treatment with $Br{{\aa}}nemark$ system implants (Group 1, rough-surfaced implants, n=20) and Oneplant system implants (Group 2, rough-surfaced neck with microthreads, n=20). Clinical and radiographic examinations were conducted at baseline (implant loading) and 1 year postloading. Data analysis was performed by the SAS statistical package version 9.1.3 (SAS Institute, Cary, NC, USA) and the final model was calculated by the MIXED procedure (three-level ANCOVA) for marginal bone change of each test group at baseline and 1 year follow-up. Results: Comparing to baseline, significant differences were noted in marginal bone level changes for the 2 groups at 1 year follow-up (P<0.05). Group 1 had a mean crestal bone level changes of $0.83{\pm}0.31mm$; Group 2 had a mean crestal bone level changes of $0.44{\pm}0.36mm$. Rough-surfaced with microthreads implants showed significantly less marginal bone loss than rough surfaced neck without microthread implants. Conclusion: A rough surface with microthreads at the implant was beneficial design to maintain the marginal bone level against functional loading.

Parotid Gland Tumors (이하선종양에 대한 임상적고찰)

  • 박혁동;심윤상;오경균;이용식
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1993.05a
    • /
    • pp.97-97
    • /
    • 1993
  • Primary tumor arises infrequently in the parotid gland and generally, only about 20 to 40 percent of which prove to be malignant. They are characterized by histopathologic diversity, slow tumor growth, significant proportion of patients who have received previous treatment elsewhere. We have reviewed retrospectively 101 cases of parotid gland tumors which were treated for the recent eight years (1985-1992), Non-neoplastic tumor-like lesions were all excluded.

  • PDF