• Title/Summary/Keyword: 기능적 방사선학적 평가

Search Result 105, Processing Time 0.037 seconds

Clinical and Radiographic Outcome of Shoulder Function after Unreamed Antegrade Intramedullary Nailing for Humerus Fracture: Ultrasonographic Evaluation for Rotator Cuff Integrity (비확공성 전향적 상완골 금속정 고정술후 견관절 기능에 대한 임상적 및 방사선학적 평가: 초음파를 이용한 회전근 개 추시관찰)

  • Baek, Seung-Hoon;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Purpose: The purpose is to perform objective evaluation for rotator cuff using ultrasonography and validate factors influencing cuff integrity as well as efficacy of follow-up ultrasonography after unreamed antegrade intramedullary nailing for humerus fracture. Materials and Methods: Seventeen patients with an average age of $55.7{\pm}18.6$ years underwent antegrade intramedullary nailing for humerus fracture and follow-up ultrasonography of shoulder joint. Mean follow-up period was $43.5{\pm}32.2$ months. Intraoperative evaluation for preoperative cuff tear was performed, of which four cuffs were repaired by single row repair technique. Clinical evaluation included visual analogue scale (VAS), range of motion, Korean Shoulder Scoring System (KSS) and American Shoulder and Elbow Society (ASES) score. Ultrasonographic evaluation was performed on cuff integrity and protrusion of proximal nail tip as well. Radiographic evaluation included time to union, protrusion of proximal nail tip and migration of proximal interlocking screw which could affect shoulder joint function. Results: Mean VAS at last follow-up was $1.65{\pm}1.84$ points. Range of motion showed forward flexion of $137.0{\pm}33.5^{\circ}$, external rotation of $43.5{\pm}12.7^{\circ}$ and internal rotation of $16.4{\pm}2.0^{\circ}$ while KSS score and ASES score were $79.6{\pm}20.7$ and $83.7{\pm}17.0$ points, respectively. Bone union was demonstrated in all cases and average time to union was $3.4{\pm}1.3$ months. Migration of proximal interlocking screw was shown in 6 cases (35%). On ultrasonographic evaluation, there were normal in 8 (47%), weaving in 4 (24%), partial tear in 5 cases (29%), but no complete tear. Protrusion of proximal nail tip was demonstrated in 8 cases (47%) on plain radiographs whereas in 11 cases (65%) on ultrasonography and was associated with increasing age (p=0.038). Ultrasonographic weaving and partial tear was associated with protrusion of proximal nail tip (p=006), but not with repair of preoperative tear (p>0.05). Conclusion: Because weaving and partial tear on ultrasonography originated from protrusion of proximal nail tip, careful insertion of nail and meticulous repair of cuff during operation lead to stable fixation with satisfactory recovery of shoulder function follow-up ultrasonography can be a useful tool for evaluating protrusion of nail tip and rotator cuff tear, of which diagnosis is difficult on plain X-ray after antegrade intramedullary nailing for humerus fracture.

  • PDF

Short-term clinical outcome of intentionally replanted posterior molars (의도적 재식술을 시행한 대구치의 단기간의 임상 평가)

  • Choi, Yong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.12-18
    • /
    • 2011
  • Objectives: This retrospective study evaluated the therapeutic effects of the intentional replantation (IR) procedure performed on the maxillary and mandibular molars of 35 patients. Materials and Methods: For the subjects, IR was performed due to difficulties in anatomically accessing the lesions and/or close proximity to the thick cortical bone, inferior alveolar nerve, or maxillary sinus, which rendered the ordinary periradicular surgery impossible. The patients'progress was followed for a year and up to 2 years and 4 months. The success of the procedure was evaluated in terms of clinical and radiographic success (%). Results: The results revealed the following: (a) 1 case (3%) of failed tooth extraction during IR; (b) 2 cases (6%) of extraction due to periodontal diseases and inflammatory root resorption; (c) 3 cases (9%) of normally functioning teeth in the oral cavity with minor mobility and apical root resorption, and; (d) 29 cases (82%) of normally functioning teeth without obvious problems. Conclusions: IR was confirmed to be a reliably repeatable, predictable treatment option for those who cannot receive conventional periradicular surgery because of anatomic limitations or patient factors.

The Reconstruction with Extracorporeal Irradiated Autograft for Osteosarcoma of Extremities (사지 골육종에서 체외 방사선 조사를 이용한 재건술)

  • Kim, Jae-Do;Lee, Gun-Woo;Chung, So-Hak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Purpose: With advances in various treatment modalities, limb salvage surgery has been commonly used in osteosarcoma of extremities. An alternative method for skeletal reconstruction is reimplantation of the tumor bearing bone following extracorporeal irradiation (ECI). We report the long-term results of ECI autograft in aspect of the oncological and functional outcomes, and complications. Materials and Methods: We retrospectively reviewed 31 osteosarcoma patients who underwent reconstruction with ECI between July 1995 and January 2006. There were 24 males and 7 females with a mean age of 24 (7-74 years) and a mean follow-up of 117 months (17-177 months). Twenty-five cases were reconstructed with ECI autograft, 6 cases with ECI autograft-prosthesis composite. The pathologic subtypes were conventional in 29 cases, periosteal in 1 case, and parosteal in 1 case. The most common location of tumor was distal femur (15 cases) followed by humerus (3), proximal fibula (3) and proximal tibia (3). Musculoskeletal Tumor Society (MSTS) score was used for functional evaluation. The overall survival rate, local recurrence, complications were analyzed. Results: The overall survival rate was 80.6% and the disease-free survival rate was 64.5%. Five patients died of distant metastasis. One patient required above-knee amputation due to local recurrence. All of them, twenty-three complications occurred, which included nonunion in 7 cases, deep infection in 5 cases, joint instability in 4 cases, metal failure in 2 cases, Limb-length discrepancy (LLD) in 2 cases, periprosthetic fracture in 1 case, epiphyseal collapse in 1, local recurrence in 1 case. The mean MSTS functional score was 62.5%. Conclusion: Extracorporeal irradiated autograft can be achieved relatively good result in aspect of oncological and functional aspect, but is needed to be additional research about occurring many complications. The reconstruction with ECI after intercalary or fragmentary resection is effective reconstruction in aspect of oncological and functional result, complications.

The analysis of difference in the relative renal function based on total counts method and average counts method (총 계수 분석법과 평균 계수 분석법에 따른 신장 기능의 차이 분석)

  • JUNG WOO-YOUNG;CHO SHEE-MAN;PARK SEUNG-YONG;SHIM DONG-OH
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.29 no.1
    • /
    • pp.44-49
    • /
    • 2003
  • Purpose : $^{99m}Tc-DMSA$ renal scan can be used in the evaluation of relative renal function and some anatomy. The relative renal function can be assess by measurement of $^{99m}Tc-DMSA$ uptake by the individual kidney. Renal counts

  • PDF

Evaluation of the Surgical Treatment for Chronic Acromioclavicular Joint Injury; Weaver and Dunn Method Versus Acromial Bone Block Transfer (오구견봉인대만을 이용한 술식과 견봉골편을 포함한 오구견봉인대를 이용한 변형 Weaver and Dunn 술식에서의 만성 견봉쇄골관절 손상 치료결과 추시)

  • Park, Jin-Young;Kang, Seung-Wan;Lhee, Sang-Hoon;Seo, Jung-Bae;Lee, Seung-Jun
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.209-216
    • /
    • 2010
  • Purpose: The purpose of our study was to compare treatment results of two different surgical techniques for chronic acromioclavicular joint dislocations. Materials and Methods: Fifty consecutive patients diagnosed as chronic acromioclavicular joint dislocations between January 1997 and June 2009 were included in the study. Patients were randomized into two different groups. Patients in the first group (n=20) were treated using a modified Weaver and Dunn method using a simple coracoacromial ligament transfer method. Patients in the other group (n=30) were treated with acromial bone-block transfer containing coracoacromial ligament. Mean follow-up times for the two groups were 13.1 and 14.9 months, respectively. Results: At 1 year postoperatively, mean coracoclavicular distance, the VAS score and the ASES score for the Weaver-Dunn method group; for the bone block transfer method group were 3.8 mm (-3 to 6 mm), 3.5 (1.0 to 7.0) and 91.1 (81.66 to 95); 3 mm (-2 to 6 mm), 4.2 (1.0 to 7.5) and 79.6 (31.66 to 95). There were no significant differences in radiologic (p=0.377) and functional (p=0.093) results between the two groups. Failures in the former and latter group were, respectively, two and one. Conclusion: The bone block transfer method shows a tendency to maintain coracoclavicular distance and appeared to yield similar results as the modified Weaver Dunn method.

Effects of Single Vessel PCI (Percutaneous Coronary Intervention) using DCR (Dynamic Coronary Road map) on Fluoroscopy Time and Patient Radiation (동적 심혈관 로드맵을 이용한 중재적 시술이 투시 시간 및 환자 피폭에 미치는 영향)

  • Jong-Gil Kwak;Young-Hyun Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.551-556
    • /
    • 2023
  • Angiography equipment is used to evaluate and treat coronary artery disease. As a common feature of equipment, radiation is used, and function development for dose reduction is being carried out by each company. Therefore, the difference depending on whether DCR installed in angiography equipment is used is analyzed from a radiological point of view to prove the effect. Among 431 patients who underwent coronary artery intervention from March 2021 to February 2023, 250 patients with retrospective data were selected. And than among the 250 subjects obtained, 91 patients used the cardiovascular roadmap function during single-vessel intervention, and 159 patients did not use the roadmap. When DCR was used, total dose area product (34.57 uGy/m2 : 69.15 uGy/m2), total air kerma dose (688.47 mGy : 1640.4 mGy), fluoroscopy dose (23.87 uGy/m2 : 49.91 uGy/m2) and fluoroscopy time (723.55 s : 366.03 s), total number of images (17 : 26) showed lower values and were statistically significant than those not used. The use of DCR function in single vessel coronary intervention is thought to be radiologically safer as single vessel coronary intervention using dynamic cardiovascular DCR showed lower perspective time and perspective dose than procedures performed without the DCR.

The Method of Radioimmunoassay (방사면역측정법(放射免疫測定法))

  • Kyong, Kwang-Hyon
    • Journal of radiological science and technology
    • /
    • v.2 no.1
    • /
    • pp.3-9
    • /
    • 1979
  • 이상 방사면역측정(放射免疫測定)의 기본원리(基本原理), 순수(純粹)한 항원(抗原), 표지항원(標識抗原), 항체생성(抗體生成), 표준곡선(表準曲線)의 작성(作成), 항원항체복합체(抗原抗體複合體)의 분리방법(分離方法)에 대(對)하여 설명(說明)하였다. 생물학적방법(生物學的方法),화학적방법(化學的方法), 기계적(機械的)인 측정방법(測定方法)에 의(依)해 생체내(生體內)의 미량(微量)으로 존재(存在)하고 있는 물질(物質)들을 정확(正確)하게 측정(測定)할 수 없다. 그러나 방사면역측정법(放射免疫測定法)에 의(依)해 쉽게 측정(測定)되어 기관(器管)의 기능검사(機能檢査)는 물론(勿論) 각(各) 기관(器管)과의 상관관계(相關關係)를 분석(分析)하여 질병(疾病)의 진단(診斷), 치료경과(治療經過)을 평가(評價)하는데 매우 중요(重要)한 정보(情報)를 제공(提供)해주고 있다. 이러한 점(點)을 고려(考慮)하여 이 방법(方法)을 잘 습득(習得)하고 진료(診療)의 수단(手段)으로 널리 이용(利用)되어 의료기술발전(醫療技術發展)에 토대(土臺)가 되기를 바란다.

  • PDF

Acutrak Screw Fixation for Radial Head Fracture -7 Cases Report- (Acutrak 나사를 이용한 요골두 골절의 치료 -7례 보고-)

  • Kim, Kwang-Yul;Lim, Moon-Sup;Shin, Heung-Sub;Choi, Shin-Kwon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.1
    • /
    • pp.75-80
    • /
    • 2006
  • Purpose: To evaluate the efficiency of Acutrak screw fixation for radial head fracture (Mason type 2) without considering the safe Bone of radial head. Materials and Methods: Consecutive seven radial head fracture of Mason type II underwent internal fixation with Acutrak screws from May 2001 to February 2003. The mean follow-up period was 1.2years (ranged, $6 months{\sim}2.5 years$). The mean age of patients was 47 years old (ranged, $36{\sim}60years$ old). The cause of injury were fall down -4 cases and traffic accident -3 cases. The results were evaluated by Mayo Clinic results scoring system. Results: Functional Rating Index of Mayo Clinic was excellent- 2 cases and good- 5 cases. There were no nonunion, loosening, heterotopic ossification, infection or degenerative changes. The postoperative range of motion in elbow joint is nearly full for flexion, extension, pronation and supination in this study Conclusion: Consideration of safe zone is not necessary when Acutrak screws are used for radial head fracture. It seems to be a useful method that Acutrak screw fixation for radial head fracture (Mason type II) could achieve good radiologic and clinical results without influencing proximal radio-ulnar joint and has powerful fixation.

  • PDF

Development of Radiation Shield with Environmentally-Friendly Materials ; Ⅰ: Comparison and Evaluation of Fiber, Rubber, Silicon in the Radiation Shielding Sheet (친환경 소재의 의료 방사선 차폐 시트 개발 ; I: 섬유, 고무, 실리콘 소재 차폐 시트의 성능 비교평가)

  • Kim, Seon-Chil;Park, Myeong-Hwan
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.121-126
    • /
    • 2010
  • Traditionally, lead has been primarily used to shield the radiation in the hospital, because of its soft texture, durability and cost effectiveness. However, lead can be dangerous because of its toxicity when exposed to the human body, and it is classified as a heavy metal like cadmium, mercury, and arsenic etc. In order to compensate its noxious properties on the human body, researchers are trying to develop a radiation shield which has similar shielding efficiency and can also be manufactured in any form. In this study, sulfuric acid barium was mixed with fiber, rubber, and silicon all of which are harmless to the human body, tested, and evaluated for its ability of medical radiation shield. The result of this study showed that the sheet containing silicon and barium has the strongest shielding abilities.

Full mouth rehabilitation of severely worn dentition using posterior implants: a clinical report (심하게 마모된 치열의 구치부 임플란트 식립을 통한 전악 수복 증례)

  • Kang, Hyun-Sun;Lee, Cheol-Won;Lee, Won-Sup;Lee, Su-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.255-262
    • /
    • 2016
  • This clinical report focuses on the treatment of a patient with esthetic and functional impairments due to severe worn dentition. Absence of posterior support for a prolonged period require comprehensive prosthetic restoration. Accurate clinical and radiographic examinations, diagnostic wax-up, and occlusal vertical dimension evaluation were performed and the degree of patient adaptability was evaluated using an interim restoration. After 8 weeks of stabilization with interim restoration and confirmation of absence of any abnormal findings, definitive prostheses were fabricated. Satisfactory functional and esthetic outcomes were observed after 6 months of follow-up.